HomeMy WebLinkAbout4817-5GENERAL NOTES 1. THE PROJECT SPECIFICATIONS FORM A PART OF THESE GENERAL NOTES. 2. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION. THE ARCHITECT SHALL BE NOTIFIED OF ANY DISCREPANCIES OR INCONSISTENCIES. 3. DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALED DRAWINGS. 4. NOTES AND DETAILS ON DRAWINGS SHALL TAKE PRECEDENCE OVER GENERAL NOTES AND TYPICAL DETAILS. WHERE NOTES AND DETAILS ON DRAWINGS AND THESE GENERAL NOTES AND TYPICAL DETAILS ARE IN CONFLICT WITH THE PROJECT SPECIFICATIONS, THE MOST STRINGENT SHALL APPLY. CONDITIONS NOT SPECIFICALLY SHOWN SHALL BE CONSTRUCTED AS SHOWN FOR SIMILAR WORK. 5. ALL WORK SHALL CONFORM TO THE STANDARDS OF THE FOLLOWING CODE: TITLE 24, PART 1 AND PART 2, 2007 CALIFORNIA BUILDING CODE AND ANY OTHER REGULATING AGENCIES WHICH HAVE AUTHORITY OVER ANY PORTION OF THE WORK, INCLUDING THE STATE OF CALIFORNIA DEPARTMENT OF INDUSTRIAL RELATIONS, DIVISION OF OCCUPATIONAL SAFETY AND HEALTH (DIRDOSH), AND THOSE CODES AND STANDARDS LISTED IN THE CONTRACT DOCUMENTS. 6. MANUFACTURED MATERIALS SHALL BE APPROVED BY THE CHECKING AGENCY PRIOR TO THEIR USE. ALL REQUIREMENTS OF THOSE APPROVALS SHALL BE FOLLOWED. 7. SEE ARCHITECTURAL DRAWINGS FOR INFORMATION NOT SHOWN INCLUDING BUT NOT LIMITED TO THE FOLLOWING: A. SIZE AND LOCATION OF ALL DOOR AND WINDOW OPENINGS. B. SIZE AND LOCATION OF ALL NON-BEARING PARTITIONS. C. SIZE AND LOCATION OF ALL CONCRETE CURBS, FLOOR DRAINS, SLOPES, DEPRESSED AREAS, CHANGES IN LEVEL, CHAMFERS, GROOVES, INSERTS, ETC. D. EXTERIOR WALL SYSTEM. E. SIZE AND LOCATION OF ALL STRUCTURAL WALL, FLOOR AND ROOF OPENINGS. F. STAIR FRAMING AND DETAILS G. DIMENSIONS NOT SHOWN ON STRUCTURAL DRAWINGS. H. ALL SECONDARY STEEL POSTS AND FRAMING MEMBERS NOT SHOWN ON STRUCTURAL DRAWINGS. I. ALL FIREPROOFING REQUIREMENTS INCLUDING FIREPROOFING OF STRUCTURAL STEEL. 8. SEE MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS FOR THE FOLLOWING: A. PIPE RUNS, SLEEVES, HANGERS, TRENCHES, WALL, ROOF AND FLOOR OPENINGS, ETC., NOT SHOWN OR NOTED. B. ELECTRICAL CONDUIT RUNS, BOXES, OUTLETS IN WALLS AND SLABS. C. ANCHORAGE AND BRACING FOR ELECTRICAL, MECHANICAL OR PLUMBING EQUIPMENT TO THE STRUCTURE. D. ANCHOR BOLTS FOR MOTOR MOUNTS. E. SIZE, WEIGHT, AND LOCATION OF MACHINES AND EQUIPMENT BASES, INCLUDING CONCRETE PADS. 9. MECHANICAL AND ELECTRICAL LOADS MAY BE SUPPORTED FROM BEAMS. LIGHT MECHANICAL AND ELECTRICAL LOADS ANCHORED INTO METAL DECK ASSEMBLY MUST BE ANCHORED INTO STRUCTURAL CONCRETE ABOVE. SEE STEEL DECKING NOTES IF NO CONCRETE IS USED. THE CONTRACTOR SHALL PROVIDE DESIGN AND DETAILS PREPARED BY CALIFORNIA REGISTERED STRUCTURAL ENGINEER FOR ALL ANCILLARY MEMBERS INCLUDING BUT NOT LIMITED TO BEAMS, COLUMNS, POSTS, FOOTINGS, STIFFENERS, GUSSETS, KICKERS, BRACES, ETC., THE ATTENDANT CONNECTIONS, AND INSTALL AS REQUIRED BY THE BUILDING STRUCTURAL ENGINEER, TO SUPPORT LOADS IMPOSED BY CURTAIN WALL, CANOPIES, ALL EQUIPMENTS, PIPING, CONDUITS, CABLE TRAYS, GUIDE RAIL SUPPORTS, CEILING, CATWALKS, ETC., ON THE PRIMARY STRUCTURE. ADDED ANCILLARY MEMBERS SHALL BE DESIGNED TO NOT IMPOSE ANY TORSIONAL LOADS ON THE PRIMARY STRUCTURE. 10. THE CONTRACT DOCUMENTS REPRESENT THE FINISHED STRUCTURE. THEY DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL PROVIDE ALL MEASURES NECCESSARY TO PROTECT THE STRUCTURE DURING CONSTRUCTION. SUCH MEASURES SHALL INCLUDE, BUT NOT BE LIMITED TO, BRACING, SHORING FOR LOADS DUE TO CONSTRUCTION EQUIPMENT, ETC. OBSERVATION VISITS TO THE SITE BY THE STRUCTURAL ENGINEER SHALL NOT INCLUDE INSPECTION OF THE ABOVE ITEMS. 11. OPENINGS, POCKETS, ETC. SHALL NOT BE PLACED IN STRUCTURAL MEMBERS UNLESS SPECIFICALLY DETAILED ON THE STRUCTURAL DRAWINGS. NOTIFY THE STRUCTURAL ENGINEER WHEN DRAWINGS BY OTHERS SHOW OPENINGS, POCKETS, ETC., LARGER THAN 6 INCHES NOT SHOWN ON THE STRUCTURAL DRAWINGS, BUT WHICH ARE LOCATED IN THE STRUCTURAL MEMBERS. 12. SPECIFICATIONS, CODES AND STANDARDS NOTED IN THE CONTRACT DOCUMENTS SHALL BE OF THE LATEST APPLICABLE ISSUE, INCLUDING SUPPLEMENTS, UNLESS OTHERWISE NOTED. MATERIAL SPECIFICATIONS ARE ASTM LATEST EDITION. 13. THE CONTRACTOR SHALL INVESTIGATE SITE FOR FILLED EXCAVATIONS OR BURIED STRUCTURES SUCH AS CESSPOOLS, CISTERNS, FOUNDATIONS, ETC. IF ANY SUCH STRUCTURES ARE FOUND, ARCHITECT SHALL BE NOTIFIED IMMEDIATELY. 14. CONSTRUCTION MATERIALS SHALL BE SPREAD OUT IF PLACED ON FRAMED FLOORS OR ROOFS. LOAD SHALL NOT EXCEED THE DESIGN LIVE LOAD PER SQUARE FOOT. PROVIDE ADEQUATE SHORING AND/OR BRACING WHERE STRUCTURE HAS NOT ATTAINED DESIGNED STRENGTH OR WHERE OVERLOAD IS ANTICIPATED. 15. THE LATERAL SYSTEM OF THE STRUCTURE IS DESIGNED WITH LATERAL RESTRAINT AT THE UPPER AND LOWER FOUNDATION LEVEL. STRUCTURAL FRAMES ARE NOT LATERALLY SELF SUPPORTING UNTIL THE ENTIRE DESIGN LATERAL RESTRAINT FLOOR AND STRUCTURAL WALLS BELOW ARE IN PLACE. STRUCTURAL FLOOR ELEVATIONS I FOUNDATIONS 1. THE FLOOR DATUM ELEVATIONS PROVIDED BELOW ARE BASED ON A PROJECT DATUM GENERAL ELEVATION OF 0'-0" AT THE TOP OF CONCRETE FLOOR SLAB AT UPPER LVL. SEE CIVIL DRAWINGS FOR THE ACTUAL ELEVATION WITH RESPECT TO SEA LEVEL OF PROJECT DATUM ELEVATION AT 1. FOUNDATION DESIGNED BASED ON SOIL REPORT BY THE FOLLOWING COMPANY: UPPER LEVEL. GEOBASE, INC., REPORT # C.314.29.00 DATED DECEMBER 14, 2007 ALL SUBSEQUENT ADDENDA 2. ELEVATIONS THAT VARY FROM THE FLOOR DATUM ELEVATIONS ON THIS PROJECT INCLUDE DATED OCTOBER 31, 2008 .COPIES ARE AVAILABLE FOR REVIEW AT THE ARCHITECT'S OFFICE. BUT ARE NOT LIMITED TO THE FOLLOWING: A. SLOPING ROOF SLABS AND SLOPING ROOF STEEL. FLOOR DATUM ELEVATIONS FOR THE 2. FOUNDATION DESIGN BASED ON FOLLOWING: ROOF SLAB ARE FOR THE LOW POINT OF THE ROOF. A. MAT FOUNDATION DESIGNED FOR ALLOWABLE NET MAXIMUM B. FLOOR DEPRESSIONS FOR EQUIPMENT DL + LL = 1,500 B. COEFFICIENT OF SLIDING FRICTION = 0.40. C. IN ALL CASES, A 1/3 INCREASE MAY BE TAKEN FOR WIND OR SEISMIC LOADS. 3. FLOOR DATUM ELEVATIONS FOR TOP OF CONCRETE (TOC) AND TOP OF STEEL (TOS) ARE AS FOLLOWS: 3. CONTRACTOR TO PROVIDE FOR DE -WATERING OF EXCAVATIONS FROM EITHER SURFACE FLOOR DATUM ELEVATIONS FOR TOC AND TOS LEVEL TOP OF CONCRETE FLOOR DATUM TOP OF STEEL ELEVATION LOWER LVL SAD - UPPER LVL VARIES, SAD 7 1/2" FROM TOC ROOF VARIES, SAD 7 1/2" FROM TOC COOLING TOWER - SAD STAIR & EQUIP ROOM ROOF VARIES, SAD 11/2" FROM TOP OF DECK WATER, GROUNDWATER OR SEEPAGE. 4. CONTRACTOR SHALL PROVIDE FOR DESIGN AND INSTALLATION OF ALL CRIBBING, SHEATHING AND SHORING REQUIRED TO SAFELY RETAIN THE EARTH BANKS. 5. EXCAVATION AND COMPACTING IF REQUIRED, SHALL BE APPROVED BY THE GOVERNING AGENCY AND THE GEOTECHNICAL ENGINEER PRIOR TO PLACING THE CONCRETE AND REINFORCING. GEOTECHNICAL ENGINEER TO SUBMIT LETTER OF COMPLIANCE TO OWNER. AND OSHPD. 6. ALL EXCAVATIONS SHALL BE PROPERLY BACKFILLED. DO NOT PLACE BACKFILL BEHIND ,RETAINING WALLS BEFORE WALLS HAVE ATTAINED FULL DESIGN STRENGTH. CONTRACTOR SHALL BRACE OR PROTECT ALL BUILDING AND PIT WALLS BELOW GRADE FROM LATERAL LOADS UNTIL ATTACHING FLOORS ARE COMPLETELY IN PLACE AND HAVE ATTAINED FULL STRENGTH. CONTRACTOR SHALL PROVIDE FOR DESIGN, PERMITS AND INSTALLATION OF SUCH BRACING. 7. FOOTINGS SHALL BE PLACED AND ESTIMATED ACCORDING TO DEPTHS SHOWN ON DRAWINGS. SHOULD SOIL ENCOUNTERED AT THESE DEPTHS NOT BE APPROVED BY THE GEOTECHNICAL DESIGN CRITERIA ENGINEER, FOOTING ELEVATIONS WILL BE ALTERED AS REQUIRED. 8. FOOTING BACKFILL AND UTILITY TRENCH BACKFILL WITHIN BUILDING AREA SHALL BE 1. DESIGN IS IN ACCORDANCE WITH THE 2007 CBC HOSPITAL REQUIREMENTS. MECHANICALLY COMPACTED IN LAYERS, IN ACCORDANCE WITH SOIL REPORT. FLOODING 2. FLOOR LIVE LOADS: WILL NOT BE PERMITTED. A. CORRIDORS, LOBBIES AND STAIRS: 100 PSF (REDUCIBLE) 9. ALL ABANDONED FOOTINGS, UTILITIES, ETC., THAT INTERFERE WITH NEW CONSTRUCTION SHALL B. STORAGE (FIXED RACKS): 125 PSF (NON-REDUCIBLE) BE REMOVED. C. STORAGE (HIGH DENSITY MOBILE RACKS): 250 PSF (NON-REDUCIBLE) 10. ALL EARTHWORK OVER EXCAVATIONS, BACKFILLS AND COMPACTION SHALL BE DONE IN D. MECHANICAL AREAS OUTSIDE EQUIPMENT FOOTPRINT: 50 PSF (REDUCIBLE) ACCORDANCE WITH SOILS REPORT RECOMMENDATIONS. E. MECHANICAL AREAS WITHIN EQUIPMENT FOOTPRINT: 20 PSF (REDUCIBLE) 11. SOIL CLASSIFICATION: UP TO TWO FEET OF FILL SOILS (SILTY SANDS OVERLYING NATIVE F. ROOF: 20 PSF (REDUCIBLE) SILTY SANDS AND GRAVELY SAND. 3. WIND LOADING: A. DESIGN WIND SPEED: 100 MPH B. WIND IMPORTANCE FACTOR: I = 1.15 C. EXPOSURE: C D. TOPOGRAPHIC FACTOR, k't = 1.0 E. DESIGN WIND PRESSURE ON COMPONENTS AND CLADDING PER 2007 CBC AND ASCE 7-05, CHAPTER 6, METHOD 2. 4. EARTHQUAKE LOADING: A. SITE CLASSIFICATION: D B. COORDINATES: 34.0714N, 117.4320W C. SEISMIC DESIGN CATEGORY (SDC): D D. SITE COEFFICIENT, Fa = 1.0 E. SITE COEFFICIENT,Fv = 1.5 F. Ss = 1.50 g SMS = 1.50 g SDs = 1.00 g SI=0.60g SMI=0.90g SDI =0.60g G. IMPORTANCE FACTOR (1): 1.00 H. OCCUPANCY CATEGORY: II I. R = 3.5 J. Qo = 3 K. DEFLECTION AMPLIFICATION FACTOR (Cd) = 3.0 L. FUNDAMENTAL PERIOD PARAMETERS, Ct = 0.028 & X = 0.8 M. Cs = 0.286 N. BASE SHEAR= 2 5. FOUNDATION DESIGN CRITERIA: SEE FOUNDATION NOTES 6. BUILDING DESIGN DISPLACEMENTS 0 A. FLOOR AND ROOF LIVE LOAD DEFLECTIONS: PERIMETER BEAMS: L/360 OR 0.5 -INCH MAXIMUM INTERIOR BEAMS: L/360 OR 0.75 -INCH MAXIMUM B. FLOOR AND ROOF DEAD LOAD PLUS LIVE LOAD DEFLECTIONS = L/240 C. ALLOWABLE SEISMIC STORY DRIFT a=.015 x STORY HEIGHT D. ALLOWABLE WIND STORY DRIFT =.004 x STORY HEIGHT rcw. KCVIJIVIVULOUKIYIIVN DATE ENGR. CITY DATE Architect Seal Consultant Seal 0 365 East Colorado Blvd t Suife200 `S ARC SHOULD CONSTRUCTION OF THE REQUIRED DPasadena, California 91101 IMPROVEMENTS NOT COMMENCE WITHIN TWO 7elephane 626.304-26,6 V� -WHAM o _17Facsimile 626.304.2676 YEARS OF THE DATE OF APPROVAL SHOWN HEREON saitul bouquet structural engineers SB Job No: 07557 $ 40 3 �' AND CARRIED FORTH IN A DILIGENT MANNER THE INSER e * NO. ,k DIAL T410 WORKING - EXP. 06/ /10 BEFORE DAYS BEFORE YOU DIG YOU DIG CITY ENGINEER MAY REQUIRE REVISIONS TO THE Kaiser Permanente ;* •r +' 3546 Concours Street UP r\ Q (P Ontario, California 91764 PLANS TO BRING THEM INTO CONFORMANCE WITH National Facilities services Phme909989-99790Fm909-483-1400 01-31' TOLL FREE 1-800-227-2600 Post Office Box 12916imc tw�w.hmmmhitects.wm A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT STANDARDS IN EFFECT. Oakland, California 94604 Mhraft OF CAQ CA�� Z:107557 -KAISER FONTANAMISER BUS SHELTERISTRUCTURALISI-BUSSHELTER.DWG Prepared Under The Supervision Of: DRAWN BY: AH DESIGNED 77 MH Date: CHECKED BY: CHIN LEE, LICENCED ARCHTECT C-17825 FT CITY OF FONTANA, CALIFORNIA BUS STOP SHELTER SIERRA AVENUE KAISER MEDICAL CENTER SCALE: AS NOTED GENERAL STRUCTURAL NOTES DATE: 02/22/2010 APPR VED BY: / _ _ DRAWING NO.: 5 DATE: 4517 iIPCITY ENGIN ER R.C.E. 51152 0