Loading...
HomeMy WebLinkAbout4817-4IF THIS SHEET IS NOT 24"x36", IT IS A REDUCED PRINT - SCALE ACCORDINGLY 4" x 12" STEEL TUBE FLEXIBLE MEMBRANE FLASHING — BEAM, TYP. OVERLAP ON VERTICAL WEATHER RESISTIVE BARRIER. 16 GA. STEEL PRE -FORMED / 5 SHEET METAL CAP W/ 4 FINISHED CAP STIFFENER. - WITH STIFFENERS. - --- 1% SLOPE 1 I I 1 — — — 1 I 1 T.O. SHEET MTL. CAP 0- HIGH PT. @ +10'-9" � � — — I T.O. SHEET ®T.O. HSS FRAMING @ +10'-6" 4 MTL. CAP @ 1/8 -- -------------- ----� SLOPE LOW PT. i TYP. ----_ -- -----%+10'-81/2"00 1J8 7/8" CEMENT PLASTER AND LATHE. r 5/8" EXTERIOR T.O. STL. ( J T.O. STL GYPSUM SHEATHING. BEAM @ SLOPE---------------------- ----- HIGH PT. r_1 �EAM @ 3/8" SEALANT WITH 2-1/2" 16 GA. METAL LOW PT. +8'-2' -------------- I + '- 1/2" BACKER ROD. STUD FRAMING I WELDED TO HSS BEAM, TYP. --- --- ' 3 J" SHAPED PLASTER SIM. 7 TRIM. WELD HORIZONTAL 6 3 4 (� STUDS TO HSS, SEE 4 u- u SIM. I 6" x 6" STEEL TUBE � WEATHER RESISTIVE COLUMN, PAINTED. BARRIER ON EXTERIOR 3/4" WIDE EXTRUDED " CEMENT PLASTER „ GYP. SHEATHING. 7 ALUMINUM VENT SYSTEM BEYOND. -� 7 STRIP, TYP. CEMENT PLASTER. DETAIL - 13 DETAIL - 10 �D DETAIL SECTION - CEMENT „_ , „ DETAIL HALF 4 PLASTER SYSTEM 1-1/2 =1 -0 FLEXIBLE MEMBRANE FLASHING OVERLAP ON VERTICAL WEATHER LEXAN PANEL, TYP. o RESISTIVE BARRIER. 3/8" SEALANT —SHEET METAL CAP W/ JOINT W/ STIFFENER. BACKER ROD I i CONC. PAVING LEVE CONT. SHEET METAL --- _ DRIP SOLDERED TO CAP „ FACE. 1-5/8"x2" ALUMINUM ��r/\r/\r/\ \r/\r/\//�/�\ \//�// \\i�\�i\\�i\\i\\�\\�\\�\\\ 3 4 \/\/\/\'\/\/\r\/ \r\�/i\ri\/i\ FLUSH GLAZING FRAME \\/\\/\\/\\/ \/ \i�\�i�\/i��i/\\�i���i, \X \X ""ice\r\\�i�/i�\/i\\ r�ri/\\/i�\rivi/r r / \\i/\\i/\o/\\r/\\r/\\//\\ SLOPE WITH KYNAR FINISH, \\\\\\\\\\\\\\\\\\\\\\\\/\\\\\\\\\\\\\\ \/\\/\\/\\/\\o\/\\/\\ -----� T o\\z M"\\/ //\rj\rj\ir\\ioioio/\i/\r/\//\i/\�/\/\i/ HK. SEALANT W/ TYP. \opo\�o\oo\o�\�`�ro��'r�i/ BACKER ROD TYP. �i\\/\\i\\i\\i\\�i \ri\/r\ri\/ - - - - - �oo�\o/\\o��/o�/�ooi\o�\/o/i�oo\\o��o/i\moi\\oma\opo/%ori\�i\\��\��\moi\\o\\o\\�\�o\oo \/\/ \/o/A 16 GA. STUD 1 /8 oo\/,00/,\/o\ o i\r\Y \r\\\ I BACKING. \/%%\j\\%o% %%\ j%\/\\\//\\\\%\\/\\\/\\/\\\ oo\\r%\\\\\ j/\\\j/\\ \�/\\\j/j///\\j jo/\\\1/8 // \ CEMENT PLASTER \ \ \ \ \ \ \\ \\ \\ \\ \\ \\ \\ \\ \\ \\ FINISH. r/ // rr // STRUCT.DVV ,err//�rrr/ rrr///rr\i\i\oor\/\ CONCRETE WALL, SEE �. STRUCT. DWG. SHEET 7 �. 3/8" SEALANT WITH BACKER ROD. NOTE: FOR ADD'L INFO, 2 �' SEE "J" SHAPED PLASTER TRIM. CEMENT PLASTER. 3/8" THK. SEALANT W/ BACKER ROD, TYP. WEATHER RESISTIVE BARRIER ON i EXTERIOR GYP. SHEATHING. DETAIL 14 DETAIL - SECTION LOOKING NORTH 1/2" ="-o,- HALF DETAIL LEXAN WALL PANEL $ DETAIL 5 CONNECTIONS HALF 2 FLUSHED GLAZING. LEXAN PANEL WITH SEALED END. STRUCT. SILICON GLAZING W/ BACKER ROD, TYP. 14 GA. 2X6 STEEL TUBE SCREEN 1/8 (METAL STUD TYP. WHERE OCCURS) i i 1/8 SKYLIGHT FRAMING PER — — — — — — — — MANUFACTURER. �I I� INTERSECTING MULLION WITH ------ o-------- GUTTER EDGE ------ - BEYOND - - - - - - - - - - - - - - - - - - - - 6"SQ. STEEL TUBE COLUMN. I HSS FRAMING 'I f DETAIL 15 DETAIL 2 DETAIL DETAIL 3"=1'-0" DETAIL HALF 3 REV. REVISION DESCRIPTION DATE ENGR. CITY DATE SHOULD CONSTRUCTION OF THE REQUIRED Prepared under The Supervision Of : CITY OF FONTANA CALIFORNIA C A RC IMPROVEMENTS NOT COMMENCE WITHIN TWO��® �c�y-WHANy��F BUS STOP SHELTER YEARS OF THE DATE OF APPROVAL SHOWN HEREON �� lF�, DRAWN BY: SIERRA AVENUE SCALE: DIAL TWO WORKING AND CARRIED FORTH IN A DILIGENT MANNER, THE SER P ASI ® 3546 Concours Street * I0. C,—,,17825 , * AH KAISER MEDICAL CENTER AS NOTED BEFORE ��..0 DAYS BEF❑RE Ontario, California 91764 „� .� DESIGNED BY: YOU DIG YO DIG CITY ENGINEER MAY REQUIRE REVISIONS TO THE Kaiser Permanente —' - - DATE: Phone 909-989-9979 • Fax 909-083-1400 DETAILS www.hmcarchdects:com �jq �%nA '�'� \��t MH 02/22/2010 PLANS TO BRING THEM INTO CONFORMANCE WITH National Facilities services ,� = ;: T�, 01 3 �� CHECKED BY: APPR VED BY: � DRAWING NO.: TOLL FREE 1-800-227-2600 R Post Office Box 12916 Ait�h�tec# F Date : / A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT STANDARDS IN EFFECT. Oakland, California 94604 OF CAL\-t/�ti 9/�0 4 FT DATE: 4817 CHIN LEE, LICENCED ARCHTECT C-17825 CITY ENGINEER R.C.E. 51152 10 N:\PROJECTS\1028-KFMC\731-163-BUS SHELTER\18-CAD\SHEETS\04-6ETAILS.DWG N:\Projects\1028-KFMC\731-163-Bus Shelter\18-CAD\Sheets\04-Details.dwg, 4/14/2010 10:26:01 AM, 1:1