Loading...
HomeMy WebLinkAbout4817-1„ i i IF THIS SHEET IS NOT 24-x36", IT IS A REDUCED PRINT - SCALE ACCORDINGLY —1100111111I KA M F\1 E E== T D U aSER PER A r\ A A IVEl A 1±t= E IN E 1i i i K� 9961 Sierra Avenue, Fontana, 92335 Art I OWNER ARCHITECTURAL STRUCTURAL CIVIL LANDSCAPE MECHANICAL / PLUMBING / ELECTRICAL SECURITY TRAFFIC KAISER PERMANENTE E HMC SAIFUL / BOUQUET RBF RHA TED JACOB ENGINEERING GROUP SAFIR / ROSETTI LINSCOTT, LAW & GREENSPAN, ARCHITECTS STRUCTURAL ENGINEERS INC CONSULTING LANDSCAPE ARCHITECTS ENGINEERS National Facilities Services 3546 Concours Street 385 East Colorado Blvd, Suite 200 14725 Afton Parkway 6216 Brockton Avenue, Suite 212 265 North Euclid Avenue 388 17th Street, Suite 230 14725 Alton Parkway Post Office Box 12916 Ontario, California 91764-5583 Pasadena, California 91101 Irvine, California 92618-2027 Riverside, Califomia 92506 Pasadena, California 91101 Oakland, California 94612 Irvine, California 92618-2027 Oakland, California 94604 Telephone: 909-989-9979 Fax: 909-483-1400 Telephone: 626-304-2616 Fax: 626-304-2676 Telephone: 949-472-3505 Fax: 949-472-8122 Telephone: 951-781-1930 Fax: 951-686-8091 Telephone: 510-268-8373 Fax: 510-839-4791 Telephone: 949-472-3505 Fax: 949-472-8122 p Telephone: 626-396-0400 Fax: 626-396-0402 i GRAPHIC SYMBOLS GENERAL NOTES CODE REFERENCE VICINITY MAP DRAWING SHEET INDEX Drawing Sheet Number No. Drawing Title NORTH ARROW I 1. A. DIMENSIONS ARE TO FACE OF STUD OR CONCRETE. INTERIOR • California Building Standards Code, 2007 Edition, BASELINE RD g known as the Shaded triangle indicates Plan North i PARTITIONS DIMENSIONS ARE TO FACE OF STUDS, FACE OF California Code of Regulations, Tie 24, which consists of: 66 ARCHITECTURAL <' D Arrow indicates True North GRID IDENTIFICATION CONCRETE, OR FACE OF MASONRY, UNLESS NOTED OTHERWISE. -The California Building Cede, Volumes 1812, based on the 2006 Top To Bottom Letters B. ELEVATIONS ARE TO TOP OF CONCRETE OR OTHER HARD International Building Code; Left To Right Numbers SURFACE r A - -The California Plumbing Cede, based on the 2006 Uniform Plumbing MATERIAL, NOT TO TOP OF FLOOR COVERING OR ROOFING, Code; FOOTHILL BLVD UNLESS NOTED OTHERWISE. - The California Electrical Code, based on the 2005 National Electrical C. DO NOT SCALE DRAWINGS. USE DIMENSIONS INDICATED. Code; or w { - The California Mechanical Code, based on the 2006 Uniform 15 > Q KEYNOTE NUMBER 2 DETAILS ARE INTENDED TO SHOW METHOD AND MANNER OF Mechanical Code;Uj LU EXTERIOR ELEVATION I ACCOMPLISHING THE WORK. MINOR MODIFICATIONS MAY BE - The California Existing Building Code, based on the 2006 > Q p CITY OF Elevation identification number REQUIRED TO SUIT JOB DIMENSIONS OR CONDITIONS AND SHALL BE International Existing Building Code; and Q A1.1 INCLUDED AS PART OF THE WORK. - The Califomia Fire Code, based on the 2006 International Fire Code. Sheet when; elevation is located UJI w FONTANA i, CnNTRnI PnINT - 1 GENERAL INFORMATION - 2 PLANS AND ELEVATIONS - 3 SECTIONS AND DETAILS - 4 DETAILS STRUCTURAL 1�.0 1w.a_v1�11VCV—r�1 Iv1vU%J 1—IV1j—Uv1? vl 7L--L-I 10—V/`lUiJ rlCG I01I—VCIVCiV-1L w4rvm1v1/1.I IVI,4.UVvl7 N:\Projects\1028-KFMC\731-163-Bus Shelter\18-CAD\Sheets\01-General Information.dwg, 4/14/2010 10:22:24 AM, 1:1 k