HomeMy WebLinkAbout4742-67ELECTRICAL GENERAL NOTES 1. ALL WORK SHALL BE IN FULL ACCORDANCE WITH ALL STATE, COUNTY, LOCAL CODES, RULES AND REGULATIONS OF GOVERNING AGENCIES HAVING JURISDICTION AND THE PRESENTLY ADOPTED EDITION OF THE NATIONAL ELECTRICAL CODE (N.E.C.). TYPE A & B = 48" REFERENCE NOTES: REFERENCE NOTES; 24" 2. THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS AND COMPLY WITH ALL INSPECTION TYPE C = 42" REQUIREMENTS. 1O TYPE A I 1O 70W METAL HALIDE IN -GRADE LIGHT FIXTURE. I 3. ALL ELECTRICAL UTILITY WORK SHALL BE IN COMPLIANCE WITH THE REQUIREMENTS 70W MH LIGHTING FIXTURE, DIRECT BURIAL TYPE, 1 HYDREL #M9410-B-P3070CM-120-MFL-FLC20- OF SOUTHERN CALIFORNIA EDISON (SCE). IT SHALL BE THE CONTRACTOR'S BRONZE HOUSING WITH 10° TILT FLAT LENS AND I 34B -BTR -SF -LP -BZ MONUMENT SIGN ROCK GUARD, HYDREL #M9720-B-70M-120-NFL-FLC10- RESPONSIBILITY TO CONTACT THE SERVING UTILITY TO RECEIVE COMPLETE INFORMATION ROCK BTR-PC211 HYDREL #M9 BZ 2 ON THEIR REQUIREMENTS PRIOR TO THE SUBMISSION OF THE BID. THE ACT OF 34BSUBMITTING THE BID SHALL CONSTITUTE ACCEPTANCE OF FULL RESPONSIBILITY BY THE TYPE B CENTER OF TREE TRUNK 70W MH LIGHTING FIXTURE, DIRECT BURIAL TYPE, 12" O CONCRETE EMBEDMENT FLUSH WITH BOTTOM CONTRACTOR TO INSTALL SERVICE IN COMPLIANCE WITH THE SERVING UTILITY AND THE I OF LENS RING AND SLOPE TO DRAIN 1 CONTRACT DOCUMENTS. BRONZE HOUSING WITH 10° TILT FLAT LENS AND ROCK GUARD, HYDREL #M9720-B-70M-120-MFL-FLC10- FINISHED GRADE �" 2• 34B-BTR-PC2112-SF-GEB-LP-B2 9" DIA. FINISHED GRADE 4. ALL ITEMS SUCH AS SERVICE CONDUIT, CONDUCTORS, CONCRETE PAD, PULL BOXES TYPE C O 12" OF PEA GRAVEL �� � 1" AAND ND SHALL COVERING WITH SCE. SERVICE LOCATION SHALL BE PROVIDED AND INSTALLED, 100W MH LIGHTING FIXTURE, DIRECT BURIAL TYPE, 4O SCHEDULE 40 PVC CONDUIT. SEE ELECTRICAL 5. CONTRACTOR SHALL VERIFY LOCATION OF ALL UNDERGROUND UTILITIES PRIOR TO START BRONZE HOUSING WITH 10° TILT FLAT LENS AND ROCK GUARD, HYDREL #M9720 -B-1 DOM-120-SP-FLC10- SITE PLAN FOR SIZE AND WIRING REQUIREMENTS. OF WORK, AND SHALL BE RESPONSIBLE FOR ANY DAMAGE INCURRED TO SAME. 34B-BTR-PC2112-SF-GEB-LP-BZ 20" a 2 6. THE CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR OCONCRETE EMBEDMENT FLUSH WITH BOTTOM • JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT, INCLUDING OF LENS RING AND SLOPE TO DRAIN SAFETY OF ALL PERSONS AND PROPERTY, THAT THE REQUIREMENTS SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS, AND THAT THE CONTRACTOR SHALL DEFEND, O #3 REBAR 2" CLEAR 4" O.C. 3 INDEMNIFY AND HOLD THE CITY AND THE ENGINEER HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK IN THIS PROJECT, EXCEPT 4OSCHEDULE 40 PVC CONDUIT. SEE ELECTRICAL 5 FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE CITY OR THE ENGINEER. SITE PLAN FOR SIZE AND WIRING REQUIREMENTS. 7. THE CONTRACTOR SHALL PROTECT PROPERTY AND FACILITIES ADJACENT TO THE CONSTRUCTION AREA AND ALL PROPERTY AND FACILITIES WITHIN THE CONSTRUCTION AREA. O 12" OF PEA GRAVEL 4 4 8. THE CONTRACTOR SHALL RESTORE ALL PUBLIC OR PRIVATELY OWNED IMPROVEMENTS AND FACILITIES (I.E. LANDSCAPING, FENCES, STRUCTURES, IRRIGATION/SPRINKLERS, MAIL BOXES, ETC.) TO THEIR ORIGINAL CONDITION PRIOR TO PROJECT COMPLETION AS DIRECTED BY THE CITY. THE CONTRACTOR SHALL RESTORE THESE ITEMS AT HIS OWN EXPENSE. IN THE EVENT IMPROVEMENTS OR FACILITES ARE DAMAGED, THEY SHALL BE REPLACED WITH NEW MATERIALS EQUAL TO THE ORIGINAL. A TYPICAL TREE UPLIGHT FIXTURE DETAIL NOT TO SCALE B TYPICAL MONUMENT SIGN LIGHT FIXTURE DETAIL NOT TO SCALE 9. IN AREAS WHERE EXISTING PAVEMENT IS TO BE REPLACED, TRENCHING INSTALLATION SHALL BE COMPLETED PRIOR TO PLACING FINAL PAVEMENT LAYER. 10. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO EXISTING UTILITIES AS A RESULT OF HIS OPERATIONS. THE LOCATION OF EXISTING UTILITIES, AS SHOWN ON THE PLANS, WAS OBTAINED FROM A SEARCH OF AVAILABLE RECORDS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY UNDERGROUND SERVICE ALERT TO DETERMINE EXACT FIELD LOCATION OF ALL UTILITIES SHOWN OR NOT SHOWN ON THE PLANS WHICH MAY CONFLICT WITH HIS OPERATIONS. POTHOLING OF EXISTING UTILITIES WILL BE REQUIRED TO DETERMINE EXACT DEPTH AND FIELD LOCATIONS AND SHALL BE THE REFERENCE NOTES: II I RESPONSIBILITY OF THE CONTRACTOR. 1 PRECAST CONCRETE UNDERGROUND 2 �- 20" '� 2 18"-�j �- 20" 11. THE CONTRACTOR SHALL EXPOSE ALL UTILITIES FAR ENOUGH IN ADVANCE OF HIS OPERATIONS TO PULL BOX SIZE AS INDICATED ON PLAN I I - ALLOW FOR ANY NECESSARY ADJUSTMENTS IN GRADE TO CLEAR THESE UTILITIES. O1" ABOVE PAVING OR 6" ABOVE 3 ROUGH GRADE AT LANDSCAPE AREA OFINISH SURFACE SHALL SLOPE AWAY FOR POSITIVE DRAINAGE O12" DEEP OF 1" COMPACTED CRUSHED ROCK 6 EXTENDING BEYOND OUTSIDE WALLS OF THE PULL BOX OPVC CONDUIT, SIZE AND QUANTITY LQ;:: AS NOTED ON PLANS OCONDUITS MUST BE SEALED AFTER 4 PULLING WIRES (TYP.) NOTES: 1. ALL SPLICES IN PULL BOXES SHALL BE WITH SCOTCHCAST 400 ELECTRICAL INSULATING RESIN, OR TWO LAYERS OF RUBBER TAPE WITH TWO LAYERS OF BLACK SCOTCH 88 TAPE AND TWO COATS OF SCOTCHCOAT WATERPROOF RESIN. CONTRACTOR MAY ELECT TO 12 USE SPLICE KITS AND CONNECTORS APPROVED FOR UNDERGROUND APPLICATIONS. SUBMIT -0 0 0 9 12. ROAD SURFACES, DAMAGED OR REMOVED, SHALL BE REPLACED TO CITY STANDARDS. 1 F 13. SIDEWALK AND PLANTED AREAS WHERE NEW PULLBOXES ARE INSTALLED SHALL BE REPLACED TO (_ MATCH THE EXISTING SURFACES. 3 ( 14. ALL TRAFFIC CONTROL TO BE INCLUDED IN BID AND TO BE PER CITY STANDARDS. JLLO - 15. ALL MATERIALS SHALL BE NEW, UL LISTED AND APPROVED AS APPROPRIATE. MATERIALS SHALL MEET 10 0 01 L THE APPROVAL OF THE DIVISION OF INDUSTRIAL SAFETY, AND ALL GOVERNING AGENCIES HAVING JURISDICTION. MATERIALS SHALL BE MANUFACTURED IN ACCORDANCE WITH APPLICABLE STANDARDS 5 8 10 ESTABLISHED BY ANSI, UL, NEMA, AND NBFU. INSTALL PER MANUFACTURER'S RECOMMENDATIONS. I� 52" 16. ELECTRICAL DRAWINGS ARE DIAGRAMMATIC. INSTALL THE ELECTRICAL SYSTEMS WITHOUT g I INTERFERING WITH IRRIGATION AND OTHER UNDERGROUND SYSTEMS. 11 17. ALL CONDUCTORS SHALL BE COPPER WITH TYPE THWN 600 VOLT INSULATION, MARKED EVERY 24" ALONG ITS LENGTH SHOWING MANUFACTURER'S NAME, MAXIMUM ALLOWABLE VOLTAGE AND SIZE. DELIVER THE WIRE TO THE SITE IN UNBROKEN PACKAGES. MINIMUM SIZE OF WIRE SHALL BE NO. 12 AWG, UNLESS NOTED OTHERWISE. 7 18. CONDUITS BELOW GRADE SHALL BE PVC SCHEDULE 40 WITH CODE SIZED GROUND. ALL CONDUIT 15 SWEEPS, RISERS AND STUBS ABOVE GROUND SHALL BE RIGID STEEL CONDUIT WITH HALF -LAPPED TAPE COVERING OR WITH FACTORY COATED PVC. RIGID STEEL CONDUIT SHALL BE INSTALLED ABOVE 13 GRADE. ell SHOP DRAWINGS FOR APPROVAL. 14 \-i 19. ALL FEEDERS IN NON-METALLIC CONDUITS SHALL HAVE GREEN GROUND CONDUCTORS SIZE IN n ..r 44 .4 a ACCORDANCE WITH APPLICABLE CODES. THE CONTRACTOR SHALL MAINTAIN UNIFORMITY AND \ \ •' \ \ \ \ •' \ \ \\ •." \\ \\ CONTINUITY OF THE GROUNDING SYSTEM. 2. PROVIDE AND INSTALL PULL BOX AS INDICATED ON THE DRAWINGS. • \/\�\/ \//\� �// / // \�j/\//\�%j\�j\�//\\\�//\�//�%/\�i%/\�/ j��//��//��//��//��//��//��/j�%j�i " 20. ALL CONDUIT ONLY (C.O.) SHALL HAVE A 3/16 NYLON PULL CORD OR ROPE AND SEALED IN ACCORDANCE WITH N.E.C. LEFT SIDE VIEW FRONT VIEW RIGHT SIDE VIEW 21. THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR ALL MAJOR PIECES OF ELECTRICAL E TYPICAL UNDERGROUND PULL BOX DETAIL NOT TO SCALE SHOWN WITH METER HOOD OPEN 180 DEGREES EQUIPMENT INCLUDING BUT NOT LIMITED TO THE FOLLOWING: METER/PANEL EQUIPMENT, LIGHTING FIXTURES, LIGHTING CONTROLS, PULL BOXES, CONDUITS AND WIRES. THE CONTRACTOR SHALL SUBMIT THE UTILITY METERING EQUIPMENT SHOP DRAWINGS TO THE SERVING UTILITY FOR APPROVAL NOTES: 1. METER/PANEL "A" AND "B" DETAILS ARE SHOWN ABOVE. PANELS "Al", "A2" AND "B1" DETAILS PRIOR TO FABRICATION. ARE SIMILAR EXCEPT 24" WIDE, 36" HIGH, 24" DEEP (NO METER). 22. PROVIDE THE CITY WITH ONE (1) SET OF COMPLETE ELECTRICAL "AS -BUILT" DRAWINGS AT THE 2. PROVIDE 3 FT. MINIMUM CLEARANCE AROUND THE EQUIPMENT. COMPLETION OF THE JOB. SHOW ACTUAL CONDUIT RUNS, DEPTHS AND LOCATIONS. FINISHED GRADE 23. TEST THE COMPLETE SYSTEM TO DEMONSTRATE THAT THE ELECTRICAL COMPONENTS AND SYSTEMS ARE COMPLETE, INSTALLED AND FUNCTION PROPERLY. MAKE NECESSARY CORRECTIONS TO MALFUNCTIONS AND LEAVE SYSTEM READY FOR OPERATION. 30" MIN. WHERE �=TIT=T�T �_�_� 24. ALL WORK SHALL BE GUARANTEED BY THE CONTRACTOR FOR A PERIOD OF ONE YEAR FROM THE DATE SUBJECTED TO 6" VEHICULAR AND SPECIFICATIONS: REFERENCE NOTES: OF ACCEPTANCE OF THE WOTK BY TRAFFIC THE CITY. MUST 24" UNDISTURBED MIN. UNDER ANY EARTH 1. 12 GAUGE STAINLESS STEEL CONSTRUCTION O METER VIEWING WINDOW S UTILITY TERMINATION LANDING CIRCUMSTANCES COMPACTED EARTH 2. WEATHERPROOF, NEMA 3R ENCLOSURE BACKFILL, FREE FROM 3. DETACHABLE PAD MOUNT SUB -BASE O DEMAND RESET COVER, HINGED a REMOVABLE SERVICE TERMINATION LARGE ROCKS AND DEBRIS 4. COPPER BUSSED INTERIORS SEALABLE COVER. SEALABLE. 2" WIDE YELLOW 0 O 180° HINGED HOOD. METER/TEST 12 ST DIA. X 10 FT. COPPERCLAD WARNING TAPE 5. COMPLIES WITH EUSERC STANDARDS & DWG. 308 SECTION COVER STEEL GROUND ROD "CAUTION BURIED ELECTRICAL SCHEDULE 40 PVC CONDUIT 6. ALL FACTORY WIRING 600 VOLT RATED COPPER 4 LOAD CENTER WITH 13 POURED CONCRETE BASE, 6- MIN. LINE BELOW" 3" 2" 2" 3" REFER TO DRAWINGS FOR 7. ALL COMPONENTS UL LISTED O MAIN BREAKER THICKNESS, EXTEND 6" BEYOND CONDUIT SIZES & QUANTITIES 8. ALL EXTERIOR DOORS AND COVERS PADLOCKABLEOUTSIDE DIMENSION OF ENCLOSURE INCREASE TO 12" O TIME CLOCK WITH MIN. 1/2% SLOPE FOR BETWEEN POWER & 9. UTILITY COVERS SEALABLE DRAINAGE SIGNAL CONDUITS 10. MUST MEET S.C.E. STANDARDS. O HINGED LOAD CENTER ACCESS G FINISHED GRADE 11. METER/PANEL "A"PB" O7 120V CONTACT BLOCK15 PROVIDE DUPLEX RECEPTACLE VIT PRODUCTS # MPS -C24 -42K. (200 AMPS.) PROVIDE COMPLETE WITH PANEL, LIGHTING CONTACTORS INSIDE THE CABINET, 20A, 125V GROUNDING NOTES: AND PHOTOCELL PHOTO ELECTRIC CELL TYPE. CONNECT TO CIRCUIT - O PROVIDE GFI CIRCUIT BREAKER. 1. REFER TO POWER/TELEPHONE CO. DRAWINGS FOR UNDERGROUND PANEL "A1" "A2" AND "61" O METER SAFETY SOCKET WITH iN VIT PRODUCTS # SB-24DSS ENCLOSURE (24" W, 36"H, 24"D) CONDUIT REQUIREMENTS. TEST BLOCKS EERS PROVIDE COMPLETE WITH PANEL, LIGHTING CONTACTORS 0 AND PHOTOCELL 1 T* wapww�� D TYPICAL UNDERGROUND ,CONDUIT SECTION NOT TO SCALE C TYPICAL PEDESTAL MOUNTED METER/PANEL DETAIL NOT TO SCALE E-13 thide grmW Smim CITY OF FONTANA. pFESS/O CITY DRAWING FILE NO. SECTION 4216/4217 OF THE GOVERNMENT FOOTHILL BLVD Q�oQ o.BE Gq�Ey ELECTRICAL DETAILS 4742 CODE REQUIRES A DIG ALERT IDENTIFICATION DRAWN BY: SCALE: NUMBER BE ISSUED BEFORE A PERMIT TO LANDSCAPE MEDIAN CITY OF FONTANA m FOOTHILL BOULEVARD NONE EXCAVATE WILL BE VALID Ex E1 -I 7O D.MA FOR YOUR DIG ALERT I.D. NUMBER CALL FROM ILEX STREET � ��, - � � DESIGNEDRBY: FROM ILEX STREET DATE: CALIFORNIA, 92335 �r F�E�TA,��� TO CHERRY AVENUE 01-23-09 UNDERGROUND SERVICE ALERT TO CHERRY AVENUE 'IF OF OAL�E�I REV 15 �D �LEGT 1 CAL PL�t� %� pg a CHECKED BY: App ° w s: DRAWING NO.: 67 TOLL FREE 1-800-227-2600 ,/ TWO WORKING DAYS BEFORE YOU DIG IL�� 1474S 69 REV REVISION DESCRIPTION DATE CITY DATE jrya