Loading...
HomeMy WebLinkAbout4737-40190-041 =028 ( 291w) 2 11+00 12+00 -� No iiiiiiiiiiiiiiiiiiiiii■ �iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii■ t�iiiiiiiiiiiiiiiit;;■iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii ---- ----------------- r ---------------- EXISTING S.D. MANHOLE PER FONTANA DWG. 4200 DATED:03-2007 0190-041-25 pp METER/SERVICE, PANEL "B" DRIVEWAY PEDESTAL CABINET ENTRANCE I -0- M A PER ELECTRICAL PLANS FONTANA DWG. - - - - - - 55::�) 4200 3/5 IRRIGATION CONTROLLER _ 1 1/2IRRIGATION WATER METER. LOCATE INSIDE ELECTRICAL — APP ROX.PSI a65 SERVICE CABINET APP X. METER ELEVATION -1300 (24 STATION) PR SED IRRIGATION SYSTEM AND MIPUM 13E3RsNIUM -NOTE-M E=RTCxE PARS, STIEET — ACCOMODATE FUTURE RECYCLED E2 FOR SERVICE CONECTION. WATER WHEN AVAILABLE. NEW ELECTRICAL SLEEVE D NEW IRRIGATION SLEEVE w `. STREET IDENTIFICATION NEW 1-1/2" MAINLINE MONUMENT 11 15+00 ■ 13+00FOOTHILL BLVD. (WESTBOUND) ■ ■ ■ 4 4' ■ :n FOOTHILL BLVD. (EASTBOUND) LL ■ W LU ■co ■ZO W Jm ■U W ■2U) ■ PP NEW 4 O ELECTRICAL SLEEVE ■ ■ STREET IDENTIFICATION NEW 4"0 IRRIGATION SLEEVE .}. FOOTHILL BLVD. (WESTBOUND) 17+00 MONUMENT SHEET 12 OF 15 �. 160O ■ 14+00 w -■ BACKFLOW PREVENTER ■ FLOW SENSOR ----- — ----- — ------ —� am AM wo ■ 3I4 314' 3/4' 3l4' 3/4' FS 3/4 3/4' 3/4' 814' _ � � ■ 4' 1" I ■ 1'314' I 314' 3/4' 3/1 ■ 3/4' m N14. 3/4 3/4' ' 3l4" ■ ■ ------------------------------------------------------------------------------------------------------------------------------------------------------------- ---- ------------------------------------------------------- ------------------------------------------------------------------ ---------------------------------------------------- ------ -------------- 1111111111M ------------------- 7 ------------------------------------------------------------------------------------ ------------------------------------------------------------------------------------ ■� � A-1 A-2 A-3 A-4 A-5 A-6 A-7 A-8 A-9 1-1/2 MAINLINE SLEEVES 1-1/2" MAINLINE■ ■w 1-1/2" 1" 1" 1-1/2" INLINE 1-1/2" 1-1/2" MAINLINE 1-1/2" 1" 1" 1" 1-1/2" EXISTING FOOTHILL BLVD. (EASTBOUND) w ■ ■ w o 20 16 12 25 24 17 16 9 21 w■ ■ Z W LOW LOW MEDIUM LOW LOW LOW BUBBLERS TO PALMS MEDIUM LOW - Z U-) ■ ■J in =Iw ■ ■U Lu U2 ■ ■M� � -■ IRRIGATION. LEGEND SYMBOL MFG. MODEL NUMBER/ DESCRIPTION PSI GPM RADIUS NOZZLE REMARKS VALVE A-24: Worst Conditions Furthest valve BACKFLOW PREVENTER 1 1/2" -10.0 ■ RAINBIRD 1804 -SAM -PRS BUBBLER WITH HUNTER NOZZLE (SHRUB) 20 1.0 - 102-1211 LAVENDER RECYCLED WATER CAP Water Meter Elevation 1300 SEE DETAIL A, SHEET 10 RAINBIRD 1804 -SAM -PRS BUBBLER WITH HUNTER NOZZLE (TREE) 20 1.0 - 102-1211 LAVENDER RECYCLED WATER CAP Irego =41-04 lbft Ift % ft OR SSMt'11( FOSSO965 "A SEE DETAIL A, SHEET 10 12"x18" LAVENDER RW LOCKABLE VALVE BOX ® R.C.V. Elevation (NUMBERED), SEE DETAIL J, SHEET 10 RAINBIRD 33DNP, 3/4" QUICK COUPLER R.C.V. Demand (G.P.M.)/Design Pressure 10" LAVENDER RW LOCKABLE VALVE BOX 54.54 Static Pressure SEE DETAIL F, SHEET 10 SEE SHEET 5 FOR GENERAL IRRIGATION NOTES SEE SHEET 10 FOR IRRIGATION DETAILS & SHEET 11 FOR RECLAIMED WATER NOTES SPECIFICATIONS ARE IN 82" X 11" BOOKLET FORM Lhdmwmnd Sw'VICQ A wt SECTION 4216/4217 OF THE GOVERNMENT FOOTHILL BLVD CODE REQUIRES A DIG ALERT IDENTIFICATION LANDSCAPE MEDIAN NUMBER BE ISSUED BEFORE A PERMIT TO ey�fY`to EXCAVATE WILL BE VALID FROM CITRUS AVE. FOR YOUR DIG ALERT I.D. NUMBER CALL UNDERGROUND SERVICE ALERT TO OLEANDER AVE. TOLL FREE 1-800-227-2600 TWO WORKING DAYS BEFORE YOU DIG NIBCO SI -7 BRASS BALL VALVE A TORO SENTINEL CONTROLLER. FONTANA PART# ESB12-U2-MPEA161OK-OBI-VRA (24 STATION CONTROLLER) AVAIL AT: AQUA FLO; CONTACT TOM RADEN (805)-895-8909 FB] FEBCO 825Y - MATCH METER SIZE, WITH CITY APPROVED FLOW METER. DATA INDUSTRIAL IR220 P -SIZE PER METER. Fm_lWATER METER INSTALLED PER CITY STANDARDS F!] "W I tl amftnso,tll "US CuSO MOM %%t* wfuuM AaJACM TO Ft+orlis6" FS DATA INDUSTRIAL 200 SERIES FLOW SENSOR SEE DETAIL B SHEET 10 INSTALL PER MANUFACTURES SPECS. APPROVED PVC CL. 315 MAINLINE; SIZE 2" AND LARGER APPROVED PVC SCH. 40 MAINLINE; SIZE 1 1/2" AND SMALLER APPROVED PVC CL. 200 LATERAL LINE; SEE PLAN FOR SIZE EXISTING PVC SCH.40 MAINLINE SLEEVE 10" LAVENDER RW LOCKABLE VALVE BOX (NUMBERED), SEE DETAIL E, SHEET 10 INSTALLED IN STAINLESS STEEL CABINET PER DETAIL SEE DETAIL D, SHEET 10 A - l\ VALVE / CONTROLLER SEQUENCE �QROFESS'�� 11 /2" VALVE SIZE 20 GPM CC C 78044 m CITY OF FONTANA CALIFORNIA, 92335 CIVIL FCFLIFG �pNDSCA J. JwC In LU (� Ce y Signature i %2 qpj, Dat. �rF OF CA0FO�? MAWU = 52.2 x.8 x 6,337 S.F. x.62 = 164,072 S.F. EAWU SHRUB AREA 6,337 S.F. 52.2 x.4 x 6,337 S.F. x.62 /.75 = 109,381 S.F PRESSURE CALCULATIONS PSI LOSS / GAIN 1 1/2" WATER METER VALVE A-24: Worst Conditions Furthest valve BACKFLOW PREVENTER 1 1/2" -10.0 Water Meter No. -3.0 1-1/2" REMOTE CONTROL VALVE A-9 Water Meter Elevation 1300 -1.59 Static Pressure 65 SCH 40 MAINLINE FRICTION 400' R.C.V. Size 1-1/; -2.0 R.C.V. Elevation 1303. DESIGN PRESSURE R.C.V. Demand (G.P.M.)/Design Pressure 30 54.54 Static Pressure 54.54 REV REVISION DESCRIPTION DRAWN BY: D.L. DESIGNED BY: R.J.M CHECKED BY: DATE CITY DATE Appurtenance/Pipe PSI LOSS / GAIN PSI LOSS / GAIN 1 1/2" WATER METER -1.5 BACKFLOW PREVENTER 1 1/2" -10.0 3 GATE VALVES -3.0 1-1/2" REMOTE CONTROL VALVE A-9 -3.6 MAINLINE HEAD GAIN / LOSS -1.59 LATERAL LINE HEAD GAIN / LOSS -0.62 SCH 40 MAINLINE FRICTION 400' -5.16 SCH 40 LATERAL LINE FRICTION LOSS -2.0 TOTAL PSI GAIN / LOSS 24.54 DESIGN PRESSURE 30.00 PSI REQUIRED 54.54 STATIC PRESSURE 65 IRRIGATION PLAN FOOTHILL BOULEVARD FROM CITRUS AVENUE TO OLEANDER AVENUE L.wa CITY DRAWING FILE NO. 4737 SCALE: 1 "=10'-0" DATE: 09-22-08 oRAW10" 4 4737 15