Loading...
HomeMy WebLinkAbout4737-1Ramona Ave Ramona Dr FOOTHILL BOULEVARD FROM CITRUS AVE TOO AND R AVE. FROM STATION POINT 10+55 TO 23+75 CENTER MEDIAN IRRIGATION & LANDSCAPE IMPROVEMENTS Montgorrery Ave IT E: a M � < ru Limekin Ln San Jacinto Ave =' Wine Dr it �_- Raymond Ave a 2 y a d Ramona Ave C6 o > M II Ier Ave � v _ ..— Q rCk ~' v ! Fairview Fairfax Dr Fa it fax St, pofk �v W Malaga Av01"'D eb Q a Malaya Ct A r 0 I -fa n �01 v o P�'tr Vi ll F •. v c n v Harvey Dr Rtvd C t CL Rcvd St c Reed St *4 I I c y M Ree E BarteeAve Q St SITE I 0 I~ SITE MAP NOT TO SCALE CD SECTION 4216/4217 OF THE GOVERNMENT CODE REQUIRES A DIG ALERT IDENTIFICATION NUMBER BE ISSUED BEFORE A PERMIT TO EXCAVATE WILL BE VALID FOR YOUR DIG ALERT I.D. NUMBER CALL UNDERGROUND SERVICE ALERT TOLL FREE 1-800-227-2600 TWO WORKING DAYS BEFORE YOU DIG FOOTHILL BLVD LANDSCAPE MEDIAN FROM CITRUS AVE. TO OLEANDER AVE. PREPARED FOR: CITY OF FONTANA PUBLIC WORKS DEPARTMENT CONTACT: TIMOTHY RASTEDT LANDSCAPE PROJECT COORDINATOR (909)-350-6649 trastedt@fontana.org PREPARED BY: RMA INTERNATIONAL CONTACT: ROBERT MCMAHON p(714)-969-4452 f (714)-969-4469 robert@rmadesign.net SHEET INDEX DESCRIPTION LANDSCAPE SHEET NUMBER TITLE SHEET 1 GRADING/ CONSTRUCTION PLAN 2 & 3 IRRIGATION PLAN 4 & 5 TREE PLANTING PLAN 6 & 7 SHRUB PLANTING PLAN 8 & 9 IRRIGATION DETAILS 10 PLANTING DETAILS & RECLAIMED WATER NOTES 11 ARCHITECT: STREET IDENTIFICATION MONUMENT 12 ELECTRICAL: LIGHTING PLAN & LIGHTING DETAILS (E1, E29 & E3) 139 14 & 15 NOTE: PROJECT SPECIFICATIONS ARE IN 8 "BOOKLET FORM CITY REQUIRED NOTES: INSPECTIONS: 1. IT IS THE LANDSCAPE CONTRACTORS RESPONSIBILITY TO CONTACT THE ENGINEERING DIVISION'S LANDSCAPE INSPECTOR 48 HOURS PRIOR TO DESIRED INSPECTION OF AN ITEM (909) 350-6632. 2. PRIOR TO RELEASE OF UTILITIES OR MAINTENANCE PERIOD COMMENCEMENT THE FOLLOWING INSPECTIONS ARE REQUIRED: PRE -CONSTRUCTION INSPECTION INSPECTION OF IRRIGATION SYSTEM IN OPEN TRENCH CONDITION (PRIOR TO BACKFILL). MAINLINE PRESSURE TEST AT 150 PSI FOT A THREE (3) HOUR CONTINUOUS PERIOD. IRRIGATION COVERAGE TESTS INCLUDING INITIAL AND FINAL TESTS. FINISH GRADE PRIOR PLANTING. PLANT MATERIALS PRIOR TO PLANTING AND SOIL PREPARATION. PLANTING, INCLUDING STREEET TREES, CONTACT THE PARKS PLANNING AND LANDSCAPE DEVELOPMENT SECTION, ENGINEERING DIVISION, FOR SPECIES AND FINAL LOCATIONS. COMPLIANCE WITH APPROVED PLANS. FINAL INSPECTION. 3. THE CITY'S REPRESENTATIVE AND LANDSCAPE CONTRACTOR SHALL BE PRESENT AT EACH INSPECTION. DATE: SEPTEMBER 22, 2008 CONSULTANTS: NOTES TO THE CONTRACTOR ARCHITECT: THIRTIETH STREET ARCHITECTS CONTACT: JOHN LOOMIS (949)-673-2643 ELECTRICAL ENGINEER: LRA ENGINEERS CONTACT: CIRILO REGALADO (951)-737-4569 CITY OF FONTANA CALIFORNIA, 92335 Vp,NDSCAjb 0�µ� J. Mc,�y 'qpC+ A . �° e1° ° - Lu m � y I.Sx.hwvwv �j Date �Q qrF Op CALF LTHE CONTRACTOR IS REQUIRED TO PULL A ELECTRICAL PERMIT FROM BUILDING AND SAFETY. THE CITY WILL PAY FOR THE COSTS OF THE PERMITS. 2.THE CONTRACTORS SHALL SUBMIT (6) COPIES OF ALL SUBMITTALS TO THE CITY FOR APPROVAL WITHIN TEN WORKING DAYS FOLLOWING THE AWARD OF CONTRACT. 33HE CONTRACTOR SHALL ORDER AND SCHEDULE THE DELIVERY OF ALL EQUIPMENT TO INSURE THAT THERE ARE NO DELAYS OR PERIODS OF INACTIVITY DURING THE CONSTRUCTION PHASE. 4.THE ELEVATIONS ON THE LANDSCAPE PLANS ARE BASED ON BENCH MARKS ESTABLISHED ON THE CIVIL ENGINEERS PLANS DATED. R ecve.o 10e##wu Iw1 4 Qac" -``;ria o<< �= om It C T8044rn sT�r crvi� ��P �FCAUF� TITLE SHEET DRAWN BY: FOOTHILL BOULEVARD D.L. DESIGNED BY: FROM CITRUS AVENUE RAM TO OLEANDER AVENUE RF -1 15 ED C LEC TR I CAL_ PLA N -717109 FM CHECKED BY: APPROVED BY: DA E: REV REVISION DESCRIPTION DATE CITY DATE 2�� 441.CITY ENGINEER R # 51152 CITY DRAWING FILE NO. 4737 SCALE: DATE: 09-22-08 DRAW MG 4-73% 1 /15