Loading...
HomeMy WebLinkAbout4736-1SIGNING AND STRIPING GENERAL NOTES 1. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVELOPMENT DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC RIGHT—OF—WAY WITHIN THE CITY LIMITS. CALL (909) 350-7610. PHELAN LOGISTICS CENTER 1 SIGNAGE & STRIPING PLANS SIGNING AND STRIPING CONSTRUCTION QUANTITIES 2. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS, DETAILS, DIMENSIONS, AND SCALE: 1 "= 40' DESIGNED BY: DATE: BW PROCEDURES DESCRIBED IN THE CALIFORNIA MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES FOR STREETS ® APPLY 4" DOUBLE YELLOW LANE LINE PER DETAIL 22 777 LF DRAWING NO.: AND HIGHWAYS, DATED SEPTEMBER 2006. JDM ENGINEER DATE: R.C.E..51152 4736 2 2❑ APPLY 4" WHITE SKIP LINE PER DETAIL 12 1087 LF 3. CONTACT TRAFFIC ENGINEERING PROJECT MANAGER AT (909) 350-7610 TWO WORKING DAY PRIOR TO REMOVAL 3❑ OF TRAFFIC CONTROL DEVICES OR EQUIPMENT. STOP SIGNS SHALL ONLY BE REMOVED BY CITY PERSONNEL. APPLY 8" SOLID WHITE STRIPE LINE PER DETAIL 38 300 LF 4. ALL WORK, MATERIALS AND EQUIPMENT FOR TRAFFIC SIGNING AND STRIPING SHALL CONFORM TO THESE PLANS, ® APPLY 12" WHITE CROSSWALK 137 LF THE STANDARD SPECIFICATIONS FOR THE CITY OF FONTANA, THE CALIFORNIA MANUAL ON UNIFORM TRAFFIC 5 APPLY TWO—WAY LEFT TURN STRIPING PER DETAIL 32 1244 LF CONTROL DEVICES FOR STREETS AND HIGHWAYS, DATED SEPTEMBER 2006. 6❑ APPLY TYPE IV(L) ARROW 3 EA 5. TWO WORKING DAYS NOTICE SHALL BE GIVEN TO THE CITY ENGINEER (909) 350-7610 FOR APPROVAL OF CONTROL POINTS OR "CAT TRACKING" PRIOR TO APPLICATION OF PAVEMENT STRIPING. ®FURNISH AND INSTALL SIGN (AND POST) AS INDICATED 4 EA 6. TRAFFIC SIGN SIZE SHALL BE FOR CONVENTIONAL ROADWAYS, UNLESS OTHERWISE SHOWN ON PLANS. 8❑ SANDBLAST & REMOVE CONFLICTING TRAFFIC STRIPES AND/OR 1217 LFPAVEMENT MARKINGS 7. ALL SIGNS SHALL BE MOUNTED ON GALVANIZED STEEL POSTS, UNLESS OTHERWISE SHOWN ON THE PLANS, PER CITY STANDARD DETAIL 4003. ® APPLY LEGEND AS INDICATED 3 EA 8. STENCILS USED FOR PAVEMENT MARKINGS SHALL MATCH CITY OF FONTANA STANDARD STENCILS. 10 APPLY 4" SOLID WHITE STRIPE LINE 100 LF 9. ALL STRIPING AND PAVEMENT MARKINGS SHALL BE ALKYD THERMOPLASTIC UNLESS OTHERWISE NOTED. ® INDICATES NOT USED ON THIS SHEET 10. CROSSWALKS SHALL HAVE 10' BETWEEN THE CENTERLINE OF THE 12" STRIPES UNLESS OTHERWISE SHOWN THE PLANS, PER CITY STANDARD DETAIL 1003. 11. AS—BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO SHALL PROVIDE RECORD DRAWINGS AND ELECTRONIC AUTODESK CAD FILES, TO THE CITY ENGINEER. 12. ALL CONFLICTING STRIPING, MARKINGS TO BE REMOVED, SHALL BE BY SANDBLASTING. 13. SUBSTITUTE TYPE "C" RAISED PAVEMENT MARKERS FOR TYPE "G" MARKERS ON DETAIL 38 ON HIGHWAYS WITH RAISED MEDIANS. 14. BLUE DOT MARKERS (BLUE R.R.P.M.) ARE TO BE INSTALLED AT ALL FIRE HYDRANT LOCATIONS PER CITY STANDARD PLAN. SCALE 1"=40' 0 20' 40' w GRAPHIC SCALE ENG#07-01572 BENCHMARK N N N 44 45 454 CITY OF FONTANA BM #241, POPLAR (660' PLUS OR MINUS SOUTH SLOVER) NAIL IN POLE #71827 EAST SIDE ELEVATION: 1043.88 FT TOLL FREE "1-800-227-2600 A PUBLIC SERVICE BY UNDERGROUND SERVICE Al FRT SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO BRING THEM INTO CONFORMANCE WITH STANDARDS IN EFFECT. ENo. OFYESDS /p� IIllZrr n6 i ;;, k\E xP.06 30 11 Q F OF CATAW BA AV E N U E SEE SHEET 2 FOR SIGNAGE AND STRIPING PREPARED UNDER THE SUPERVISION OF: Associated Engineers A DIVISION OF PARSONS BRINCKERHOFF AMERICAS 3311 EAST SHELBY STREET • ONTARIO, CALIFORNIA 91764 TEL.: (909) 980-1982 • FAX: (909) 941-0891 RCE 64696 1 V oct JEFFERE . MEITER EXP.: 6/30/11 DATE N N N CITY OF FONTANA, CALIFORNIA STREET IMPROVEMENT PLAN DRAWN BY: BW SLOVER & CATAWBA AVENUES IGNAGE AND STRIPING SCALE: 1 "= 40' DESIGNED BY: DATE: BW /' 10/03/2007 CHECKED BY: APPROVED DRAWING NO.: 1 JDM ENGINEER DATE: R.C.E..51152 4736 2 n RECORD .•. , ,•�u���/� SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO BRING THEM INTO CONFORMANCE WITH STANDARDS IN EFFECT. ENo. OFYESDS /p� IIllZrr n6 i ;;, k\E xP.06 30 11 Q F OF CATAW BA AV E N U E SEE SHEET 2 FOR SIGNAGE AND STRIPING PREPARED UNDER THE SUPERVISION OF: Associated Engineers A DIVISION OF PARSONS BRINCKERHOFF AMERICAS 3311 EAST SHELBY STREET • ONTARIO, CALIFORNIA 91764 TEL.: (909) 980-1982 • FAX: (909) 941-0891 RCE 64696 1 V oct JEFFERE . MEITER EXP.: 6/30/11 DATE N N N CITY OF FONTANA, CALIFORNIA STREET IMPROVEMENT PLAN DRAWN BY: BW SLOVER & CATAWBA AVENUES IGNAGE AND STRIPING SCALE: 1 "= 40' DESIGNED BY: DATE: BW /' 10/03/2007 CHECKED BY: APPROVED DRAWING NO.: 1 JDM ENGINEER DATE: R.C.E..51152 4736 2 This plan copyrighted by Associated Engkreers. Inc. - 2008\ rn 3 v W > O J M I C� z CL 0' F— N I I 0 / cD z la- a-, a I— tn z w ME w O 3 rn O QD 0 O O N 1-11