HomeMy WebLinkAbout4736-1SIGNING AND STRIPING GENERAL NOTES
1. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVELOPMENT
DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION SHALL
BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC RIGHT—OF—WAY
WITHIN THE CITY LIMITS. CALL (909) 350-7610.
PHELAN LOGISTICS CENTER 1
SIGNAGE & STRIPING PLANS
SIGNING AND STRIPING CONSTRUCTION
QUANTITIES
2.
THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS, DETAILS, DIMENSIONS, AND
SCALE:
1 "= 40'
DESIGNED BY:
DATE:
BW
PROCEDURES DESCRIBED IN THE CALIFORNIA MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES FOR STREETS
®
APPLY 4" DOUBLE YELLOW LANE LINE PER DETAIL 22
777 LF
DRAWING NO.:
AND HIGHWAYS, DATED SEPTEMBER 2006.
JDM
ENGINEER DATE:
R.C.E..51152
4736
2
2❑
APPLY 4" WHITE SKIP LINE PER DETAIL 12
1087 LF
3.
CONTACT TRAFFIC ENGINEERING PROJECT MANAGER AT (909) 350-7610 TWO WORKING DAY PRIOR TO REMOVAL
3❑
OF TRAFFIC CONTROL DEVICES OR EQUIPMENT. STOP SIGNS SHALL ONLY BE REMOVED BY CITY PERSONNEL.
APPLY 8" SOLID WHITE STRIPE LINE PER DETAIL 38
300 LF
4.
ALL WORK, MATERIALS AND EQUIPMENT FOR TRAFFIC SIGNING AND STRIPING SHALL CONFORM TO THESE PLANS,
®
APPLY 12" WHITE CROSSWALK
137 LF
THE STANDARD SPECIFICATIONS FOR THE CITY OF FONTANA, THE CALIFORNIA MANUAL ON UNIFORM TRAFFIC
5
APPLY TWO—WAY LEFT TURN STRIPING PER DETAIL 32
1244 LF
CONTROL DEVICES FOR STREETS AND HIGHWAYS, DATED SEPTEMBER 2006.
6❑
APPLY TYPE IV(L) ARROW
3 EA
5.
TWO WORKING DAYS NOTICE SHALL BE GIVEN TO THE CITY ENGINEER (909) 350-7610 FOR APPROVAL OF
CONTROL POINTS OR "CAT TRACKING" PRIOR TO APPLICATION OF PAVEMENT STRIPING.
®FURNISH
AND INSTALL SIGN (AND POST) AS INDICATED
4 EA
6.
TRAFFIC SIGN SIZE SHALL BE FOR CONVENTIONAL ROADWAYS, UNLESS OTHERWISE SHOWN ON PLANS.
8❑
SANDBLAST & REMOVE CONFLICTING TRAFFIC STRIPES AND/OR
1217 LFPAVEMENT
MARKINGS
7.
ALL SIGNS SHALL BE MOUNTED ON GALVANIZED STEEL POSTS, UNLESS OTHERWISE SHOWN ON THE PLANS, PER
CITY STANDARD DETAIL 4003.
®
APPLY LEGEND AS INDICATED
3 EA
8.
STENCILS USED FOR PAVEMENT MARKINGS SHALL MATCH CITY OF FONTANA STANDARD STENCILS.
10
APPLY 4" SOLID WHITE STRIPE LINE
100 LF
9.
ALL STRIPING AND PAVEMENT MARKINGS SHALL BE ALKYD THERMOPLASTIC UNLESS OTHERWISE NOTED.
®
INDICATES NOT USED ON THIS SHEET
10. CROSSWALKS SHALL HAVE 10' BETWEEN THE CENTERLINE OF THE 12" STRIPES UNLESS OTHERWISE SHOWN
THE PLANS, PER CITY STANDARD DETAIL 1003.
11. AS—BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO SHALL
PROVIDE RECORD DRAWINGS AND ELECTRONIC AUTODESK CAD FILES, TO THE CITY ENGINEER.
12. ALL CONFLICTING STRIPING, MARKINGS TO BE REMOVED, SHALL BE BY SANDBLASTING.
13. SUBSTITUTE TYPE "C" RAISED PAVEMENT MARKERS FOR TYPE "G" MARKERS ON DETAIL 38 ON HIGHWAYS WITH
RAISED MEDIANS.
14. BLUE DOT MARKERS (BLUE R.R.P.M.) ARE TO BE INSTALLED AT ALL FIRE HYDRANT LOCATIONS PER CITY
STANDARD PLAN.
SCALE 1"=40'
0 20' 40' w
GRAPHIC SCALE
ENG#07-01572
BENCHMARK
N
N
N
44 45 454
CITY OF FONTANA BM #241, POPLAR (660' PLUS OR
MINUS SOUTH SLOVER) NAIL IN POLE #71827 EAST
SIDE
ELEVATION: 1043.88 FT
TOLL FREE "1-800-227-2600
A PUBLIC SERVICE BY UNDERGROUND SERVICE Al FRT
SHOULD CONSTRUCTION OF THE REQUIRED
IMPROVEMENTS NOT COMMENCE WITHIN TWO
YEARS OF THE DATE OF APPROVAL SHOWN HEREON
AND CARRIED FORTH IN A DILIGENT MANNER, THE
CITY ENGINEER MAY REQUIRE REVISIONS TO THE
PLANS TO BRING THEM INTO CONFORMANCE WITH
STANDARDS IN EFFECT.
ENo.
OFYESDS /p�
IIllZrr
n6 i
;;,
k\E xP.06 30 11
Q
F OF
CATAW BA AV E N U E
SEE SHEET 2
FOR SIGNAGE AND STRIPING
PREPARED UNDER THE SUPERVISION OF:
Associated Engineers
A DIVISION OF PARSONS BRINCKERHOFF AMERICAS
3311 EAST SHELBY STREET • ONTARIO, CALIFORNIA 91764
TEL.: (909) 980-1982 • FAX: (909) 941-0891
RCE 64696 1 V oct
JEFFERE . MEITER EXP.: 6/30/11 DATE
N
N
N
CITY OF FONTANA, CALIFORNIA
STREET IMPROVEMENT PLAN
DRAWN BY:
BW
SLOVER & CATAWBA AVENUES
IGNAGE AND STRIPING
SCALE:
1 "= 40'
DESIGNED BY:
DATE:
BW
/'
10/03/2007
CHECKED BY:
APPROVED
DRAWING NO.:
1
JDM
ENGINEER DATE:
R.C.E..51152
4736
2
n
RECORD .•.
, ,•�u���/�
SHOULD CONSTRUCTION OF THE REQUIRED
IMPROVEMENTS NOT COMMENCE WITHIN TWO
YEARS OF THE DATE OF APPROVAL SHOWN HEREON
AND CARRIED FORTH IN A DILIGENT MANNER, THE
CITY ENGINEER MAY REQUIRE REVISIONS TO THE
PLANS TO BRING THEM INTO CONFORMANCE WITH
STANDARDS IN EFFECT.
ENo.
OFYESDS /p�
IIllZrr
n6 i
;;,
k\E xP.06 30 11
Q
F OF
CATAW BA AV E N U E
SEE SHEET 2
FOR SIGNAGE AND STRIPING
PREPARED UNDER THE SUPERVISION OF:
Associated Engineers
A DIVISION OF PARSONS BRINCKERHOFF AMERICAS
3311 EAST SHELBY STREET • ONTARIO, CALIFORNIA 91764
TEL.: (909) 980-1982 • FAX: (909) 941-0891
RCE 64696 1 V oct
JEFFERE . MEITER EXP.: 6/30/11 DATE
N
N
N
CITY OF FONTANA, CALIFORNIA
STREET IMPROVEMENT PLAN
DRAWN BY:
BW
SLOVER & CATAWBA AVENUES
IGNAGE AND STRIPING
SCALE:
1 "= 40'
DESIGNED BY:
DATE:
BW
/'
10/03/2007
CHECKED BY:
APPROVED
DRAWING NO.:
1
JDM
ENGINEER DATE:
R.C.E..51152
4736
2
This plan copyrighted by Associated Engkreers. Inc. - 2008\
rn
3
v
W
>
O
J
M
I
C�
z
CL
0'
F—
N
I
I
0
/
cD
z
la-
a-, a
I—
tn
z
w
ME
w
O
3
rn
O
QD
0
O
O
N
1-11