Loading...
HomeMy WebLinkAbout4296-2(jtNtKAL NU I t,5: 1. TRAFFIC SIGNAL, SIGNING AND STRIPING, AND LIGHTING SHALL CONFORM TO THESE PLANS, THE SPECIAL PROVISIONS, THE CITY OF FONTANA STANDARD DETAILS, AND THE STATE OF CALIFORNIA STANDARD SPECIFICATIONS SECTION 86 (DATED MAY 2006) AND STANDARD PLANS (DATED MAY 2006) THE CALIFORNIA MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES FOR STREETS AND HIGHWAYS, DATED SEPTEMBER 2006. 2. LOCATION OF ALL UNDERGROUND FACILITIES ARE APPROXIMATE. THE CONTRACTOR SHALL POTHOLE TO DETERMINE THE EXACT LOCATIONS AND VERIFY ALL CONDITIONS ON THE JOB SITE. HAND DIG FOUNDATINS UNTIL CLEAR OF ANY OBSTRUCTIONS. PHONE UNDERGROUND SERVICE ALERT AT (800) 227-2600, TWO (2) WORKING DAYS BEFORE DIGGING. 3. ALL PULLBOXES SHALL BE No. 6 AND CONDUIT SHALL BE 2" RIGID METAL UNLESS OTHERWISE SHOWN. 4. NOT USED 5. CONTRACTOR SHALL OBTAIN APPROVAL FROM THE ENGINEER FOR EXACT EQUIPMENT LOCATIONS PRIOR TO FINAL PLACEMENT. SEE DETAIL THIS SHEET. 6. ALL REQUIRED CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA ENGINEERING DIVISION PRIOR TO COMMENCEMENT OF WORK. 7. CONTRACTOR SHALL RELOCATE AND/OR REPLACE LANDSCAPING, SPRINKLERS, AND SIDEWALK AFFECTED BY THE CONSTRUCTION TO THE SATISFACTION OF THE ENGINEER. 8. CONTROLLER CABINET SHALL NOT BE SUBJECTED TO WATER FROM SPRINKLERS. MODIFY SPRINKLER SYSTEMS IF NECESSARY. 9. THE ALIGNMENT OF INTERCONNECT DUCTS SHALL BE AS STRAIGHT AS POSSIBLE. HOWEVER, WHEN CHANGES IN ALIGNMENT ARE NECESSARY, SWEEPS SHALL HAVE MINIMUM RADIUS OF 10 FEET. 10. ALL VEHICLE INDICATIONS SHALL BE 12" AND HAVE L.E.D. SIGNAL MODULES. ALL PEDESTRIAN HEADS SHALL HAVE L.E.D. PEDESTRIAN MODULES PER SPECIAL PROVISIONS. 11. ANY EXISTING TRAFFIC SIGNALS AND LIGHTING SHALL REMAIN IN OPERATION UNTIL REPLACED WITH NEW CONSTRUCTION. 12. CONTRACTOR TO FURNISH ALL EQUIPMENT, MATERIALS, AND HARDWARE TO CONSTRUCT THE TRAFFIC SIGNAL AND LIGHTING AS SHOWN ON THE PLANS, EXCEPT AS NOTED CITY FURNISHED OR LISTED AS CITY PROVIDED IN THE SPECIAL PROVISIONS. 13. CONTRACTOR SHALL REFER TO THE CITY TRAFFIC ENGINEER IN THE EVENT OF A CONFLICT OR POTENTIAL CONFLICT WITH THESE PLANS AND, OR SPECIFICATIONS FOR THIS PROJECT. 14. WHERE TRAFFIC SIGNAL STREET CROSSING CONDUIT ARE NOT INSTALLED USING THE BORING METHOD, TRENCH REPAIRS SHALL BE PER CITY STANDARD, AND SPECIAL PROVISIONS, SECTION E. 15. TRAFFIC SIGN SIZE SHALL BE FOR CONVENTIONAL ROADWAYS UNLESS OTHERWISE SHOWN ON THE PLANS. TRAFFIC SIGN DIMENSIONS, COLOR AND LETTERING SHALL CONFORM TO THE LATEST CALTRANS SIGN SPECIFICATIONS SHEETS. SIGN CODES SHOWN HEREON ARE TO CONFORM TO 2006 CA MUTCD CODES. CONDUCTOR SCHEDULE �k A.W.G. SIZE POLE OR RUNS OR CABLE SIZE CIRCUIT HPSV LUMINAIRE o -v NO. r POLE HEIGHT o -v 05 --F-06 11 ZA 1 C POLE (D 0 ARROW QUAD Q TYPE 22 (E) 35' 1 1 1 1 1 1 1 N 12 D SV -2-T SP -1 -CS 8 --►w- SOUTH 25OW - 20 1 35' 65' POLE O 21' 4' 3 -MAS SV -1 -T SP -1 -CS 6 1 1 1 Cherry Ave U TYPE 22 (E) 35' - 15' 24' 4' - 1 1 1 --►- POLE O 25OW - ® 61A-5-80 (E) 35' 55' 1 1 4' 3 -MAS SV -1-T T 4 NORTH 25OW Baseline Ave Q TYPE 22 (R) 1 1 15' (R) 21' R POLE O SV -2-T (R) SP -1 -CS (R) 4 --►- NORTH 25OW 1 1 ® 61A-5-80 (E) 35' S C 15' 23' 6' 3 -MAS SV 1-T SP -1 -CS 2 WEST 25OW Cherry Ave POLE TYPE 22 (E) 35' - 1 1 1 1 1 1 - SV -2-T SP -1 -CS 2 N D U POLE O - ® 161A-5-80 1 1 1 1 1 1 1 1 2' 4' 3 -MAS SV -1-T C POLE 1 1 1 1 1 1 1 1 1 1 3 T 0 POLE@) 1 1 1 1 1 1 1 1 1 1 1 1 S TOTAL CABLES 1z, 2 2 3 3 >`_�4X4 4 4 4 4 .3 124 110 LUMINAIRES 2 2 2 2 2 — — 22 VIDEO COAXIAL CABLE 1 1 2 2 1 2 2 2 1 1 1 — VIDEO POWER CABLE 1 1 2 2 2 2 2 1 1 — OPTICOM CABLE 1 1 1 2 2 2 2 2 1 1 — CONDUIT SIZE in. 3" 1 3" 3" 3" 3" 3%" 3%" 3" 3" 3" �c ALL EXISTING CONDUCTORS TO BE REUSED * ALL EXISTING CONDUIT TO REMAIN CONSTRUCTION NOTES: r1j EXISTING TYPE 90 CONTROLLER AND TYPE P CABINET TO REMAIN fl EXISTING TYPE III—BF SERVICE PEDESTAL TO REMAIN 3� EXISTING R73-6 SIGN PER CALTRANS STANDARD ES -6T, DETAIL U ® EXISTING AUTOSCOPE CAMERA AND BRACKET PER CITY STANDARD DETAIL No. 4004 5� RELOCATE EXISTING TYPE 22 POLE &EQUIPMENT PER POLE SCHEDULE AND AS SHOWN ON PLAN. REMOVE FOUNDATION COMPLETELY, BACKFILL PER SPECIFICATIONS. 6❑ EXISTING UNIDIRECTIONAL, SINGLE CHANNEL OPTICOM DETECTOR, (MODEL 711) 7� REMOVE EXISTING #5P.6. AND FURNISH &INSTALL NEW #6 P.B. CURB / BERM FLOW LIN OR EDGE OF SHOULDE BCR SIGNAL STANDARD PLACEMENT DIMENSIONS AND EQUIPMENT LOCATIONS 01 02 03 04 SIGNAL MOUNTING PED PUSH BUTTOMS HPSV LUMINAIRE o -v NO. r POLE HEIGHT o -v 05 --F-06 11 07 j 08 PHASE DIAGRAM POLE AND EQUIPMENT SCHEDULE POLE SIGNAL STANDARD PLACEMENT DIMENSIONS SIGNAL MOUNTING PED PUSH BUTTOMS HPSV LUMINAIRE NON -ILLUMINATED STREET NAME SIGN NO. DESCRIPTION POLE HEIGHT SIGNAL MAST ARM LUMINAIRE MAST ARM "All mB» MAST ARM VEHICLE POLE VEHICLE POLE PEDESTRIAN 0 ARROW QUAD Q TYPE 22 (E) 35' - 15' 20' 4 - SV -2-T SP -1 -CS 8 --►w- SOUTH 25OW - 20 161A-5-80 (E) 35' 65' 15 - 21' 4' 3 -MAS SV -1 -T SP -1 -CS 6 --ood*= EAST 25OW Cherry Ave Q TYPE 22 (E) 35' - 15' 24' 4' - SV -2-T SP -1 -CS 6 --►- EAST. 25OW - ® 61A-5-80 (E) 35' 55' 15' 21' 4' 3 -MAS SV -1-T SP -1 -CS 4 NORTH 25OW Baseline Ave Q TYPE 22 (R) 35' - 15' (R) 21' 4' - SV -2-T (R) SP -1 -CS (R) 4 --►- NORTH 25OW - ® 61A-5-80 (E) 35' 65' 15' 23' 6' 3 -MAS SV 1-T SP -1 -CS 2 WEST 25OW Cherry Ave Q TYPE 22 (E) 35' - 15' 21' 4' - SV -2-T SP -1 -CS 2 --► WEST 25OW - ® 161A-5-80 (E) 35' 60' 15' 2' 4' 3 -MAS SV -1-T SP -1 -CS 8 SOUTH 25OW Baseline Ave (R) RELOCATE TOLL FREE -qqmmw- 1-800-227-2600 . A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT to aftm gnaw .1 BASELINE RECORD DRAWING rheinformation on this drawing is obtained from others and must be verified in the field by anyone prior to use or construction. HALL& FOREMAN, INC. is not responsible for underground facility locations or depictions. All above ground facilities can be readily seen and verified by the parties that intend to use same. WDID,No. 8 360337238 REV. REVISION DESCRIPTION DATE ENGR. CITY DATE Q DATE: AUGUST 2007 E -6 z� DRAWING NO.: 2 �„ a 4296 0 4 o� D �� �>z�� I N� �r��o� GMS • � A-VEN.U-E- EX. SCE SERVICE POINT EX. PACBELL VAULT 3" SCHED. 40 PVC W/SERVICE CONDUCTOR TO SERVICE CABINET 0 CHERRY AVE AND BAR HARBOR R.D 2"C & S.I.C. TO CONTROLLER CABINET 0 CHERRY AVE & BAR HARBOR R.D. SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO BRING THEM INTO CONFORMANCE WITH CONDITIONS AND STANDARDS IN EFFECT. SEAL—ENGINEER 4R�ESS/ <, r Z 0 W No. 31681 Exp. 12/31/08 s�q CIVI1. OF CA�_\F YAC ` 8 EX. INTERCONNECT CONDUIT �------------------------------------------------------------------------------ V\ - =1W e mr Inc.' � Civil Engineering •Planning •Surveying -Public Works 9130 Anaheim PI. Ste. 120 • Rancho Cucamonga, CA 91730.909-919-7800 DRAWN BY. PREPARED UNDER THE SUPERVISION OF: DESIGNED BY. MT Im d o� 1-5 41 ._ 20 0 20 40 .3 scale 1 » 20' feet o E SERVICE ADDRESS: 7412 CHERRY AVENUELO N P` 0 CITY OF FONTANA, CALIFORNIAwo TRAFI= IIC SIGNAL MODIFICATION PLAN N BASELINE AVENOR / CHERRY AVENUE S � 30V0 7 CHECKED Y: APP D BY: AROLD ARTHUR GARCELON, P.E. R.C.E. 31681 DATE CITY ENGINEER R.C.E. 51152 DATE: CN N � SCALE: 1 to 20' o / p, Q DATE: AUGUST 2007 E -6 z� DRAWING NO.: 2 �„ a 4296 0 4 o�