Loading...
HomeMy WebLinkAbout4267-1CONDUCTOR SCHEDULE A.W.G. SIZE OR CABLE SIZE POLE OR CIRCUIT RUNS 000i&&A&0&® PED PUSH BUTTONS HPSV LUMINAIRE REFLECTIVE STREET NAME SIGN N0. ESCRIPTIO POLE HEIGHT SIGNAL MAST ARM LUMINAIRE MAST ARM « A C 0 C 12 0 D N C T C 01 R 3 O SR S POLE (2) „ « F POLE VEHICLE 1 i 1 i 1 i 1 1 1 1 i -A 1 1 - POLE OB 12' 4' - i 1 1 1 1 1 1 1 --N► 1 1 - POLE OC B 17A-3-100 35' 20' 1 1 1 1 1 1 1 -MAS 1 1 SV -1-T POLE OD 6 -090— E 250W See Legend Detail i 1 1 1 10' 1 1 - POLE OE 4' - - TV -1-T SP -1-T 6 i E 1 - POLE OF 1 1 1 1 45' 15' 12' 4' 2 -MAS 1 1 SV -1-T SP -1-T POLE OG -ww-- 1 1 250W See Legend Detail E 1-A 10' 1 1 - 12' POLE O - - TV -I -T SP -I -T 4 —Sw- N 1 i - F TOTAL CABLES 12C/3C 1 1 2 2 1 1 2 2 3 3 4 4 5 3 3 5 5 - LNINAIRES 2 2 - 2 2 2 2 - - - VIDEO COAXIAL CABLE 1 11- SP -1-T 111 —00► 2 2 - - 4 VIDEO POWER CABLE 1 1 - 1 1 2 2 - - 4 EVP CABLE 1 1 - 1 1 2 2 2 4 - CONDUIT SIZE (in.) (3) (3) (3) (3) (3) (3) (3) (3) (3) (3) (E)=EXISTING (N)=NEW GENERAL NOTES a CITRUS AVENUE '1'ypioal dgnal placement unless �imendons noted on plane. For`u NOTE H" dimendons refer to POLE BCHpyu. or u directed by the Engineer. Negative A" refer to a distance departing intersection away from BC or EC. 4TGNAT. STANnARn PLACEMENT DIMENSIONS AND EQUIPMENT LOCATIONS 1. Traffic signal, signing and striping, and lighting shall conform to these plans, the Special Provisions, the City of Fontana Standard Details, and the State of California Standard Specifications Section 86 (dated May 2006) and Standard Plans (dated May 2006)),- the California Manual on Uniform Traffic Control Devices (MUTCD) for streets and highways dated September 2006. 2. Location of all underground facilities are approximate. The Contractor shall pothole to determine the exact location and verily a all conditions on the job site. Hand dig foundations until clear of anyobstructions. Phone Underground Service Alert (800) 226-2700, two working days before digging. 3. All pull boxes shall be No.6 and conduit shall be 2" rigid metal unless otherwise shown. 4. The Contractor shall make application for electrical service and scheduling with Southern California Edison Company lour weeks in advance of need. 5. The Contractor shall obtain approval from the Engineer for exact equipment locations prior to final placement. See detail on this sheet. 6. All required construction permits shall be obtained from the City M� of Fontana Engineering Division prior to commencement of work. 77"r 7. The Contractor shall relocate and/or replace landscaping, sprinklers, and sidewalk affected by the construction to the satisfaction of the Engineer. 8. The controller cabinet shall not be subjected to water from sprinklers. The Contractor shall modify sprinkler systems if necessary. 9. The alignment of interconnect ducts shall be as straight as possible. However, when changes in alignment are necessary, sweeps shall have minimum radii of 3 feet. 10. All vehicle indications shall be 12" and have L.E.D. signal modules. All pedestrian heads shall have L.E.D. pedestrian modules and utilize pedestrian countdown timers per the Special Provisions. 11. Any existing traffic signals and li`hting shall remain in operation until replaced with new construction. 12. The Contractor shall furnish all equipment, materials, and hardware to construct the traffic signal and 1�ghti as shown on the plans, except as noted city furnised or listed as city provided in the Special Provisions. 13. The Contractor shall refer the the City Traffic Engineer in the event of a conflict or potential conflict with these plans and/or specifications for this project. 14. '/here traffic signal street crossing conduits are not installed using the boring method, trench repairs shall be per detail this sheet, and Special Provisions, Section E. 15. Traffic sign size shall be for conventional roadways unless otherwise shown on the plans. NEW A.C. TACK COAT ALL EDGES EXISTING AC SURFACING SACK CONCRETE BACKFILL INITIAL POUR TO BE FLUSH IITH SURROUNDING SURFACE) RIGID METAL CONDUIT V NSTALLED WITH MINIMUM COVER) TRENCH REPAIR DETAIL (i N.T.S. CITRUS AVENUE POLE AND EQUIPMENT SCHEDULE POLE SIGNAL STANDARD PLACEMENT IMENSION SIGNAL MOUNTING PED PUSH BUTTONS HPSV LUMINAIRE REFLECTIVE STREET NAME SIGN N0. ESCRIPTIO POLE HEIGHT SIGNAL MAST ARM LUMINAIRE MAST ARM « A B MAST ARM VEHICLE „ « F POLE VEHICLE POLE EDESTR 0 ARROW QUAD A i -A 10' - - 12' 4' - - TV -1-T SP- i -T 8 --N► S - - B 17A-3-100 35' 20' 15' 12' 4' 1 -MAS - SV -1-T SP -1-T 6 -090— E 250W See Legend Detail C 1-A 10' - - 12' 4' - - TV -1-T SP -1-T 6 —► E - - D 26A-4-100 35' 45' 15' 12' 4' 2 -MAS 19' SV -1-T SP -1-T 4 -ww-- N 250W See Legend Detail E 1-A 10' - - 12' 4' - - TV -I -T SP -I -T 4 —Sw- N - - F 26-4-100 30' 45' 15' 12' 4' 2 -MAS 18' SV- i -T SP -1-T 8 S 250W See Legend Detail G i -A 10' - - 12' 4' - - TV -1-T SP -1-T 2 —00► 1 - - H 17A-3-100 35' 20' 15' 18' 4' 1 -MAS - SV -I -T SP -1-T 2 A 250W See Legend Detail 1t LUMINAIRE SHALL BE INSTALLED ON STRAIGHT MAST ARM. CONTRACTOR FURNISHED S.N.S. SHALL BE MOUNTED ON A SHAFT MOUNTED HORIZONTAL MAST ARM. POLES SHALL BE DECORATIVE. CITY FURNISHED. PHASE DIAGRAM 01 02 1 03 04 ALA II NOT I USED I NOT I USED 05 06 7 1 08 2"C, 2#10 (LIGHTING) 2"C 'f/PULL ROPE 46281171X. P48 SPLICE VAULT EMERGENCY VEHICLE PRE-EMPTION DETECTO] CONSTRUCTION NOTES Legends for OVERHEAD STREET NAME SIGNS Location: Citrus Avenue and Walnut Avenue `5 Walnut st . 16100 NEC E'.. Citrus Ave F=m ssoo NWC Citrus Ave F ; 6900 Walnut Ave F r 16000 SWC MAST ARM E.V.P. MOUNTING DETAIL N.T.S City supplied equipment shall be reimbursed by the Developer. al — Install city furnished TYPE 90 controller equipment package including TYPE "R" cabinet, SOLO PRO video detection, battery backup, and appurtenant equipment. Controller cabinet and foundation shall be installed per city Standard Plan No. 4001. The Contractor shall furnish and install any additional electronic equipment required to provide the signal operation as shown on the plan. Furnish and install TYPE III -BF Service Equipment Enclosure per City of Fontana and Southern Californian Edison Company requirements. (See Special Provisions). 3❑ — Install city furnished IMAGE sensor unit per city Standard Drawing No. 4004 as directed by the Engineer. ®— Install city, furnished uni-directional, single channel OPTICOM DETECTOR (MODEL 711 or equal) per detail on this sheet and as directed by the Engineer. Furnish and install mast arm mounted sign, as indicated. ©— Furnish and install 3" P.V.C. conduit with 1/4"poly pull rope per S.C.E. requirements. Coordinate service with SCE (Chris Lorimer at 909-357-6221). 7a — Change out existing #6 P.B. to a #6E. GRAPHIC SCALE 10 0 5 10 20 40 (IN PWT) 1 INCH = 20 FEST