Loading...
HomeMy WebLinkAbout4261-2J � I I Z I 22 22 I 22 I QJ W cS I m 3 IN I c� 01 ZJ t ' t W I i I 000 > z ti I N FOOTHILL ' 13 t I I I I t I --- I i t\ AB TYP. CB I I v Lj� Li W WLi Ld = o i JII ui ----------------------------- ----—_--------- m it ___---- LTJ o II 345' TO BACK — — — — OF X—WALK - N II TYP. AB 6 TYP. AB n ' Ld w I 00 6 — it � I r� w iI I I Q Z ------------------- —EX. C/G -- MATCHLINE "A" SEE SHEET 1 r r� ¢ _ o EX. R/W �- — — r---- —----------- BC EX. 2"C, INSTALL , NEW DLC -- -- -- REMOVE EX. DLC MATCHLINE "B" SEE SHEET 1 40' TO MATCHLIP 100'y TO MATCHLINE GENERAL NOTES: I 1, TRAFFIC SIGNAL, SIGNING AND STRIPING, AND LIGHTING SHALL CONFORM TO THESE PLANS, THE SPECIAL PROVISIONS, THE CITY OF FONTANA STANDARD DETAILS, AND I I p THE STATE OF CALIFORNIA STANDARD SPECIFICATIONS SECTION 86 (DATE, ,JULY I I N 1999) AND STANDARD PLANS (DATED, JULY 209 ). j q 9 9) , w t ' � I2. LOCATION OF ALL UNDERGROUND FACILITIES ARE APPROXIMATE. THE CONTRACTOR I wI SHALL POTHOLE TO DETERMINE THE EXACT LOCATIONS AND VERIFY ALL CONDITIONS ON THE JOB SITE. HAND DIG FOUNDATIONS UNTIL CLEAR OF ANY OBSTRUCTIONS. t I 3i PHONE UNDERGROUND SERVICE ALERT AT (800) 227-2600, TWO (2) WORKING CONSTRUCTIONDAYS BEFORE DIGGING. NOTES: I o I 3. ALL PULLBOXES SHALL BE No. 6 AND CONDUIT SHALL BE 2" RIGID METAL UNLESS I I r I OTHERWISE SHOWN. I I / L r 4. DETECTOR LOOPS SHALL BE CENTERED IN TRAFFIC LANES UNLESS SHOWN I OTHERWISE.I 13 EXISTING 2"C, W/SIC, 6PR/#19, TO MULBERRY 5. CONTRACTOR SHALL OBTAIN APPROVAL FROM THE ENGINEER FOR EXACT EQUIPMENT LOCATIONS PRIOR TO FINAL PLACEMENT. SEE ES -4C FOR POLE 14 EXISTING 2"C W PULLROPE FOR FUTURE SIC. I I I LOCATION DETAIL. L __ J L --i 6. ALL REQUIRED CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF I I I FONTANA DEPARTMENT OF ENGINEERING PRIOR TO COMMENCEMENT OF WORK. I I AB I i t Lu I 7. CONTRACTOR SHALL RELOCATE AND/OR REPLACE LANDSCAPING, SPRINKLERS, AND I I I NP• I I I SIDEWALK AFFECTED BY THE CONSTRUCTION TO THE SATISFACTION OF THE ENGINEER. u I I I 8. CONTROLLER CABINET SHALL NOT BE SUBJECTED TO WATER FROM SPRINKLERS. I I I I t MODIFY SPRINKERS SYSTEMS IF NECESSARY. I I I I 9, THE ALIGNMENT OF INTERCONNECT DUCTS SHALL BE AS STRAIGHT AS POSSIBLE. I HOWEVER, WHEN CHANGES IN ALIGNMENT ARE NECESSARY, SWEEPS SHALL HAVE I I MINIMUM RADIUS OF 3 FEET. 10. ALL VEHICLE INDICATIONS SHALL BE 12' AND HAVE LE.D. SIGNAL MODULES. ALL PEDESTRIAN HEADS SHALL HAVE L.E.D. PEDESTRIAN MODULES EQUIPPED WITH I I I I I ¢ t COUNTDOWN TIMERS (SEE SPECIAL PROVISIONS). I I I ' ?�- 11. ANY EXISTING TRAFFIC SIGNALS AND LIGHTING SHALL REMAIN IN OPERATION UNTIL _ I _ _ ,� I I u -i REPLACED WITH NEW CONSTRUCTION. 12. CONTRACTOR TO FURNISH ALL EQUIPMENT, MATERIALS, AND HARDWARE TO I ,I CONSTRUCT THE TRAFFIC SIGNAL AND LIGHTING AS SHOWN ON THE PLANS, EXCEPT AS NOTED CITY FURNISHED OR LISTED AS CITY PROVIDED IN THE SPECIAL I PROVISIONS. I TV. 13, CONTRACTOR SHALL REFER TO THE CITY TRAFFIC ENGINEER IN THE EVENT OFA I AB r I t CONFLICT OR POTENTIAL CONFLICT WITH THESE PLANS AND, OR SPECIFICATIONS II t t FOR THIS PROJECT. I Y Y L __ J U J 14. WHERE TRAFFIC SIGNAL STREET CROSSING CONDUIT ARE NOT INSTALLED USING THE BORING METHOD, TRENCH REPAIRS SHALL BE PER SPECIAL PROVISIONS, SECTION E. I I m 3 -I O I II 15. TRAFFIC SIGN DIMENSIONS, COLOR, AND LETTERING SHALL CONFORM TO THE LATEST CALTRANS SIGN SPECIFICATIONS SHEETS. SIGN CODES SHOWN HEREON I o LL. 17 1 ARE TO CONFORM TO 2006 CA M.U.T.C.D. CODES. TRAFFIC SIGN SIZE SHALL BE t I N FOR CONVENTIONAL ROADWAYS UNLESS OTHERWISE SHOWN ON THE PLANS. EX.2"C, 1 NEW DLC r-.. in /%At i' = 20' BOULEVARI I ---- ----- ------ 1 345' TO BA OF X—WALK J AUTOCAD FILENAME:Foothill