Loading...
HomeMy WebLinkAbout4238-1101:601 Lol Q1c�!p LANDSCAPE ARCHITECTURAL CONSTRUCTION DOCUMENTS FOR �Awl C.F.D. MEDIAN AREAS FONTANA, CALIFORNIA JOHN LAING HOMES - CORONA, CA L-1 TITLE SHEET INSPECTIONS- A.B. Anchor Bolt Int. Integral 1. It is the Landscape Contractor's responsibility to contact the Engineering Division's Landscape Inspector 48 hours prior to A.C. Asphaltic Concrete J. Box Junction Box desired inspection of an item at 909)350-6649. Adj. Adjacent its. Joints L,-2 CONSTRUCTION PLAN Alt. Alternate L.A. Landscape Architect 2 Prior to release of utilities or maintenance period commencement, the following inspections are required: Arch. Architect Lie. Licensed Auto. Automatic L.P. Low Point L-3 CONST. & PLANTING DETAILS -Pre-Construction Meeting Bldg. Building Max. Maximum -Inspection of irrigation system in open trench condition (prior to backfill). Mainline pressure test @ 150 P.S.I. for a Blk. Black M.B. Machine Bolt L-4 IRRIGATION PLAN three (3) hour continuous period. B.M. Bench Mark Mech. Mechanical •Irrigation coverage tests including initial and final tests. B.S. Bottom of Steps Med. Medium •Finish grade prior to planting. C.B. Catch Basin Min. Minimum L-5 IRRIGATION DETAILS •Plant materials prior to planting and soil preparation. C.F. Cubic Foot M.H. Manhole -Planting, including street trees. Contact the Parks Planning & Landscape Development Section, Engineering I C.I. Cast Iron Multi. Multi -branched L-6 PLANTING PLAN Division, for species and final locations. C.I.P. Cast Iron Pi Nat. Natural Compliance with approved plans. 1'e :Compliance Inspection. C.J. Cold Joint N.I.C. Not in Contract L -s 7 CONSTRUCTION SPECS.C.L. Center Line O.C. On Center ,Clr. Clearance O.D. Outside Diameter 3. The Owner representative and landscape contractor shall be present at each inspection. SIERRA LAKES ARKWAY NOW,WOMC.O. Clean Out P.A. Planting Area L-8 IRR. AND PLANTING SPECS.C.M.P. Corrugated Metal Pipe Perf. PerforatedMAINTENANCE GUIDELINES: ® 0* ® a Comp. Compacted P.O.C. Point of Connection Landscape shall be maintained in a neat, clean, weed -free and healthy condition. For three (3) months (90 days) following ®®� ® Con. Concrete P.S.I. Pounds Per Square installation, this shall include but not be limited to: Cond. Condition P.T. Pressure Treated Cont. Continuous P.V.C. Poly Vinyl Chloride 1. Cultivation of planted beds at intervals not to exceed ten (10) days. Ct. Center R. Radius "" -- Cir. Sink Counter Sink R.C.P. Reinforced Concrete 2. Regular mowing to maintain lawn height not to exceed two (2) inches (will vary with species). t I D.D. Deck Drain Rebar Reinforcing Bar 3. Regular pruning of plants as necessary to control and direct growth. D.F. Douglas Fir Rein. Reinforcing D.G. Decomposed Granite Req'd. Required 4. Scheduled maintenance of irrigation controller to assureproperaPPlication rate of water necessary for proper plant growth. u. � DRet. Retardant Dia. Diameter Drip irrigation may require specialized landscape maintenance care. ate' "rt' Dim. Dimension Rgh. Rough ' - - - - - - -DtL Detail R.S. Rough Sawn 5. Immediate replacement of irrigation materials as needed to maintain good working conditions. I a "� a „�. Ea. Each R.S.R. Rough Sawn Redwood • ° ° . - - { E.J. Expansion Joint Rwd. Redwood 6. Fertilization on a regular schedule as recommended by the manufacturer to provide proper plant growth. �,m �� '""", ,�.,,, w„ { ' • ,�°,,, �„� � ,,,.,F1ec. Electric Sch. Schedule W Elev. Elevation S.F. Square Foot 7. Immediate repair or replacement of irrigation materials as needed to maintain good working conditions. Z Z Eng. Engineer Sht. Sheet 8. Stakes, guys & ties on trees shall be checked regularly for correct function. Ties are to be adjusted to avoid abrasions or W R,"R, .,,. ��'� �1 w..,m �*,« d L � „�,� ,�,,,,, ,.., W Esp. Espalier Sht. Md. Sheet Metal I °., «R, n n , rt" « f Q I Eq. Equal Sim. Similar girdling of trunk or branches. "� « '"°"' U_ -I """„” ' E.W. Each Way S.L. Scoreline P P () ( �) P P Y Community Q^'° �^'° ' y 9. Upon completion of three 3 month 90 da contract maintenance period, an inspection shall be made b the W„, ,.. ° S E.W.W.M. Electric Welded Wire Mesh Smth. Smooth Development Department Engineering Division Landscape Inspection Staff. The landscape shall be maintained in - - - ■ ■ ' - _ W Ex. Existing Specs. Specifications accordance with these landscape maintenance standards. D' ` - - - - a _ _ o Exp. Exposed Sq. Square m - _ F.F. Finish Floor Elevation Stl. Steel 10. The Developer/Builder is responsible to contact the City and schedule the maintenance inspection. • } I F.G. Finish Grade T.A.D. Top of Area Drain ' I F.H. Fire Hydrant T & B Top and Bottom CITY REQUIRED NOTES: ' Fin. Finish T.B. Top of Berm All plans must be installed in accordance with the Standard Landscape Specification Manual For Streetsea es And Parks. The ,■ F.L. Flow Line T.C. Top of Curb P P P P specifications can be purchased at the Engineering counter at city hall. 8353 Sierra Ave., Fontana, CA 92335, www.tontana.org ,a .. ,,, ., ,. Flt. - Flat Tex. Textured 12 A F.S. Finish Surface T.G. Top of Grate • • • ■ • • Ftg. Footing T.G.D. Top of Grate Drain I I Ftn. Fountain Thk. Thick ■ ° • . - Ga. Gauge T.P. Top of Paving Hp SC AAF .. Galy. Galvanized T.P.C. Top of Poll Couping o G.C. Ground Cover T.S. Top of Steps ARCHITERRA DESIGN GROUP HEREBY CERTIFIES THAT THE DESIGN, DETAILS AND k� ` .T1 • mum �'ka q9�, _ o �7-� Q o o - o G.I. Galvanized Iron T.W. Top of Wall SPECIFICATIONS AS REPRESENTED HEREIN MEET PROFESSIONAL LANDSCAPE H.B. Hose Bib Twl. Trowel ARCHITECTURAL STANDARDS. ARCHITERRA DESIGN GROUP CANNOT GUARANTEE rn t • i ' m � ' « r a .,°I� I Hdr. Brd. Header Board Typ. Typical THE QUALITY OF CONSTRUCTION, INSTALLATION OR MAINTENANCE OF IMPROVEMENTS AS DESIGNED AND/OR SPECIFIED HEREIN AND DISCLAIMS ANY FUTURE LIABILITY Horiz. Horizontal Vert. Vertical signature H.P. High Point W/ With RESULTING FROM DEVIATIONS. ARCHITERRA DESIGN GROUP IS NOT RESPONSIBLE ,* 7W/08 i FOR THE AMOUNT OR FREQUENCY OF IRRIGATION WATER APPLIED TO THE PROJECT aeruwa Dace - ( Hgt. Height W/O Without 1 :.f r• .1- I.D. Inside Diameter W.S. Water Surface DURING CONSTRUCTION OR THEREAFTER. >' Inv. Invert B.C.R. Beginning of Curb Radius E.C.R. End of Curb Radius F 0 '"�' `` `, ,t I z'A''`4 • z` '4,,x+° ri L , rt x:;+C� i. jfti1 22A b� SHOULD CONSTRUCTION OF THE REQUIRED , t IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL DRAWN Bl'� SIERRA LAKES PKWY. MEDIANS SCALE: SHOWN HEREON AND CARRIED FORTH IN A k }" KPF TRACT. # 17842 AS SHOWN DILIGENT MANNER, THE CITY ENGINEER MAY DESIG''M BY UNITY FACI (TIES DISTRICT DATE: i REQUIRE REVISIONS TO THE PLANS TO KPF 3/22/07(BASE) 7 r BRING THEM INTO CONFORMANCE WITH CHECKED BY: APPROVED DWG. NO.: a a s 1 + i REV REVISI DESCRIPTION DATE CITY DATE RC/KPF 4238 8 CONDITIONS AND STANDARDS IN EFFECT ON J � DATE: •/D. 777 IL. =1-millfiluma OKK 41 t CITY RC.E 51152 EXP. DATE 1?131ib7 m Y 4r FIRST SUBMITTAL - 4/10/07 (CLIENT/CITY SUBMITTAL) JOHN LAING HOMES MADOLE AND ASSOCIATES $z SECOND SUBMITTAL.— 7/25/07 (CITY SUBMITTAL) 255 E. RINCON ST., STE. 100 1455 AUTO CENTER DR., STE. 200 0 k 4 CORONA, CALIFORNIA 92879 ONTARIO, CALIFORNIA 91761 a THIRD SUBMITTAL TEL: (951) 272-5100 TEL.. (909) 937-9151 PROJECT SITE FAX: (951) 738-9426 FAX.: (909) 937-9152 ' FOURTH SUBMITTAL - ;f CONTACT PERSON: CHRIS STAMPS CONTACT PERSON: GERRY BARRON o Underground Service Alert,£il .... _ • .Ya ' • • • • • ■ Call: TOLL FREE z 0536-5 � � ARCHITERRA DESIGN GROUP' rq y .fin ��`� �%��x+..•• c -. a., '' "� r €; 4 � � *� � �INC. • ■ LANDSCAPE ARCHITECTURE 1-800 n A�.. SITE PLANNING 10221-A TRADEMARK STREET 422-4133 ^ RANCHO CUCAMONGA, CALIFORNIA 91730 � Y x li TEL.: (909) 484-2800 FAX: (909) 484-2802 TWO WORKING DAYS BEFORE YOU DIG SCALE: N.T.S. .w �'.Y.� .. . ��...��., .� a.x �.x - CONTACT: KEN FRICKE t< • SCALE: N.. .8. 1 OF 8 SHEETS t �Q aN