HomeMy WebLinkAbout4225-12M H C, Distribution reinforcement V Note: All longitudinal bars shall be #4 @ 18"c.c., except bottom face of top slab when distribution reinforce- ment is required. Longitudinal bars TYPICAL RC BOX SECTION NOT TO SCALE T2/,) T2 TOP OF WALL T2 LONGITUDINAL JOINT 20 Bar BASE OF WALL TRANSVERSE JOINTS 1/3 CONSTRUCTION JOINT DETAILS NOT TO SCALE 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13 14. 15. 16 17. STRUCTURAL NOTES DIMENSIONS FROM FACE OF CONCRETE TO STEEL ARE TO CENTER OF BAR, UNLESS OTHERWISE SHOWN. CONCRETE DIMENSIONS SHALL BE MEASURED HORIZONTALLY OR VERTICALLY ON THE PROFILE, AND PARALLEL TO OR AT RIGHT ANGLES (OR RADIALLY) TO CENTER LINE OF CONDUIT ON THE PLAN EXCEPT AS OTHERWISE SHOWN. ALL BAR BENDS AND HOOKS SHALL CONFORM TO THE AMERICAN CONCRETE INSTITUTE'S "BUILDING CODE REQUIREMENT FOR REINFORCED CONCRETE", LATEST EDITION, SECTION 7.2. TRANSVERSE CONSTRUCTION JOINTS SHALL NOT BE PLACED WITHIN 30 INCHES OF MANHOLE OR JUNCTION STRUCTURE OPENINGS. TRANSVERSE CONSTRUCTION JOINTS IN WALLS AND SLABS SHALL BE IN THE SAME PLANE. NO STAGGERING OF JOINTS WILL BE PERMITTED. TRANSVERSE CONSTRUCTION JOINTS SHALL BE NORMAL OR RADIAL TO THE CENTER LINE OF CONSTRUCTION. THE TRANSVERSE REINFORCING BARS SHALL TERMINATE ONE AND ONE-HALF INCHES FROM THE CONCRETE SURFACES UNLESS OTHERWISE SHOWN ON THE STRUCTURAL DETAILS. EXPOSED SURFACES OF CONCRETE MEMBERS SHALL BE ROUNDED OR BEVELED. NO SPLICES IN TRANSVERSE BARS REINFORCEMENT WILL BE PERMITTED OTHER THAN SHOWN ON THE DRAWING WITHOUT APPROVAL OF THE ENGINEER. NO MORE THAN TWO SPLICES WILL BE PERMITTED IN ANY LONGITUDINAL BAR BETWEEN TRANSVERSE JOINTS. SPLICES SHALL BE STAGGERED. LONGITUDINAL BARS SHALL BE LAPPED 40 BAR DIAMETERS AT SPLICES. TRANSVERSE BARS SHALL BE LAPPED 48 BAR DIAMETERS AT SPLICES. LONGITUDINAL BARS SHALL BE CONTINUOUS AND EXTEND THROUGH ALL CONSTRUCTION JOINTS. UNLESS OTHERWISE SHOWN ON THE DRAWINGS, TRANSVERSE CONSTRUCTION JOINTS (IN BOTH SLABS AND WALLS), SHALL BE PLACED AT THE END OF EACH POUR, BUT THE SPACING THEREOF SHALL NOT EXCEED 50 FEET NOR BE LESS THAN 10 FEET. UNLESS OTHERWISE SHOWN ON THE DETAILS, IN CURVED SECTIONS TRANSVERSE BARS SHALL BE PLACED RADIALLY. THE SPACING OF STRAIGHT TRANSVERSE BARS IN TOP AND BOTTOM SLABS SHALL BE MEASURED AT THE CENTER LINE OF CONSTRUCTION. THE SPACING OF STRAIGHT BARS AND L -BARS IN WALLS SHALL BE MEASURED BETWEEN THE VERTICAL LEGS OF BARS. AT THE BEGINNING AND ENDING OF ALL POURS, A CURTAIN OF REINFORCEMENT COMPOSED OF B, C, C2, D, F, G, AND H BARS SHALL BE PLACED THREE INCHES FROM THE TRANSVERSE CONSTRUCTION JOINT. D BARS MAY BE SPLICED 48 BAR DIAMETERS AT THE LOWER LONGITUDINAL CONSTRUCTION JOINT, AT CONTRACTOR'S OPTION. IN ALL SECTIONS LAP C AND C2 BARS. THE VERTICAL LENGTH OF C AND C2 HAS BEEN CALCULATED FOR A FOUR -INCH STARTER WALL. IF THE HEIGHT OF THE STARTER WALL IS VARIED, THE VERTICAL LENGTH OF THE C AND C2 BARS SHALL BE VARIED CORRESPONDINGLY SO AS TO MAINTAIN A 48 DIAMETER LAP BETWEEN THE TWO BARS. THE LAPS SHALL BE BASED ON THE SMALLER BARS. CONCRETE QUANTITIES ARE BASED ON A SIX -BY -SIX INCH FILLET AND STEEL QUANTITIES DO NOT INCLUDE ANY OPTIONAL SPLICES. IF WALL THICKNESS IS SIX INCHES, PLACE REINFORCEMENT AT THE CENTER LINE OF THE WALL. STRUCTURAL DESIGN CRITERIA L.A.C.F.C.D. STRUCTURAL DESIGN MANUAL DATED APRIL 1982 LIVE LOAD HS 20-44 unless otherwise noted DEAD LOAD Earth load per Marston's formula: w= 140 pcf Ku=Ku'=0.165 Bd=Outside width of box plus 3 feet Side earth 60 psf per foot of depth Internal water pressure: 62.4 psf per foot of depth Weight of concrete: 150 pcf ALLOWABLE STRESSES f'c=4000 psi at 28 days fc =1800 psi fs =24,000 psi n =8 Shear and bond stresses per A.C.I. 318-63 BOX SECTION 1 2 3 Design Cover 10' 10' 8' Width W 16' 14' 18' Height H 8' 8' 7' Top Slab Thickness T1 19.25" 1711 15.25" Side Wall Thickness T2 12" 10.50" 12.50" Bottom Slab Thickness T3 21.50" 18.50" 17" Concrete Cover 3" Min. Y 3" 3" 3" B Bars Bar No. & Spacing #9 @ 8" #9 @ 9" #8 @ 8" Length 17'-9" 15'-6" 19'-10" B 1 Bars Bar No. & Spacing #4 @ 8" #4 @ 9" #5 @ 8" Length 9'-1.5" 7-11.5" 10'-6.5" C Bars Bar No. & Spacing #4 @ 11" #4 @ 14" #6 @ 14" Hor. Length 6'-9.5" 6'-2" 7-2.5" Vert. Length 9'-9" 9-6.5" 7'-8.5" C1 Bars Bar No. & Spacing #5 @ 11" #5 @ 14" #8 @ 14" Hor. Length 2'-9.5" 2-5.5" 6' Vert. Length 4'-10.5" 3'-10" 7'-8.5" C2 Bars Bar No. & Spacing #5 @ 11" #4 @ 14" #6 @ 14" Hor. Length 7'-4" 6'-2" 7'-2.5" Vert. Length 11'-9.5" 4'-4" 4'-4.5" C 3 Bars Bar No. & Spacing -- #4 @ 14" #7 @ 14" Hor. Length -- 2'-1.5" 2'-9" Vert. Length -- 2'-9" 5' D Bars Bar No. & Spacing #4 @ 18" #4 @ 18" #4 @ 18" Length 11'-10.5" 11'-5.5" 9'-5.5" F Bars Bar No. & Spacing #8 @ 10" #9 @ 8" #9 @ 8' Length 17'-9" 15-6" 19'-10" F 1 Bars Bar No. & Spacinq #8 @ 10" #4 @ 8" #5 @ 8" Length 17'-9» 7'-8" 10' G Bars Bar No. & Spacing #4 @ 11" #4 @ 14" #6 @ 14" Length 8'-0" 7'-0" 9'-0" H Bars Bar No. & Spacing #5 @ 11" #4 @ 14" #6 @ 14" FLength 8'-0" 7'-0" 9'-0' NUMBER OF LONGITUDINAL REINFORCEMENT # 4 BARS includes eionTop Slab � orcen) 25 23 29 Bottom Slab 25 23 29 Side Walls 20 20 16 TOTAL 70 66 74 QUANTITIES Concrete Cu. Yds./Lin. Ft. 2.89 2.28 2.58 Steel Lbs./Lin. Ft. 346.7 268.0 432.3 1� -- 1`�: v C, 0 L U M t N CN G v M a N M L6 N d O 0 N 1-1M 0 U_ 0 J D 0 W U M U N 0 M U N 0 V) I N _ Cl - to to / W W V) / 0 3 N W V) Q / 0 3 0 w z J W N 4 M I �r rn U)