1. ALL PLASTIC PIPE TO BE INSTALLED ACCORDING TO THESE DETAILS UNLESS OTHERWISE NOTED OR DETAILED.
2. THE PORTLAND CEMENT CONCRETE USED FOR THRUST BLOCKS SHALL BE 420-C-2000 CONCRETE.
3. ALL ANCHOR RODS SHALL BE GALVANIZED STEEL, MIN. 1/2 INCH DIAMETER, WRAPPED AROUND PIPE,
1,4. SIZE OF THRUST BLOCKS SHALL BE ACCORDING TO MANUFACTURER'S RECOMMENDATIONS,
5. THRUST BLOCKS SHALL BE USED FOR PLASTIC PIPES WITH 2-1/2" DIAMETER OR LARGER.
6. FLOW DIRECTIONS INDICATED BY
7. ALL VIEWS ARE PLAN VIEW UNLESS OTHERWISE SHOWN.
8. THRUST BLOCKS FOR 4" & 6" PIPE SHALL PROVIDE 6 SO. FT. OF CONTACT AREA.
THRUST BLOCKS
NOTE:
1. LOCATE QUICK COUPLER VALVES NO FURTHER
THAN 12" FROM ALL FINISHED SURFACE EDGES.
2. USE TEFLON TAPE ON ALL MALE PIPE THREADS.
FINISH GRADE
CHAMFER EDGE
2 - QUICK COUPLING VALVE
4,
10" ROUND CONCRETE VALVE BOX
THREADED BRASS RISER ✓ W/ CAST IRON HINGED LOCK LID
SAME SIZE AS VALVE ° MARKED
° PEA GRAVEL INSIDE VALVE BOX & 4"
STAINLESS STEEL o THICK BELOW MESH.
BAND CLAMPS
DOUBLE SWING JOINT W/
THREADED SCH. 80 NIP ES
BRASS ELBOWS & ST. ELLS
24"
BRICK CONTINUOUS ° �• • I
24" MIN. NO. 4
REBAR STAKE
1/2" GALV. W.W.
MESH 18/19 GAUGE. _
WRAP 6" UP OUTSIDE
OF VALVE BOX.
PVC TEE SCH. 80
PVC ELL SCH. 80
BRASS NIPPLE 6" LONG MIN.
PVC MAIN LINE SCH 80
QUICK COUPLER VALVE
NOTE:
1. ALL PLASTIC PIPING TO BE SNAKED IN TRENCHES WITH LABELS UP.
2. BUNDLE & TAPE WIRING @ 10' INTERVALS. TAPE TO SIDE OF PIPE.
3. TIE A LOOSE 20" LOOP IN WIRING AT CHANGE OF DIRECTION GREATER THAN
30 DEGREES. UNTIE ALL LOOPS AFTER ALL CONNECTIONS HAVE BEEN MADE.
4. SEE IRRIGATION SPECIFICATIONS FOR BACKFILL AND COMPACTION REQUIREMENTS
OF PIPE WHERE PIPE RUNS UNDER PAVEMENT OR ROADWAYS, DEPTH DIMENSION
SHALL BE TAKEN FROM BOTTOM OF SUB -BASE.
5. PIPES SHALL HAVE A MIN. 6" HORIZONTAL CLEARANCE BETWEEN THEM.
6. THE CONTRACTOR SHALL PROVIDE PIPE SLEEVES OR CONDUIT WHEN RUNNING
UNDER ASPHALT OR CONCRETE 24" MIN.
7. FINE GRANULAR MATERIAL SHALL BE PLACED ON ALL LINES, NO LARGER
THAN 1/2" IN SIZE. THIS WILL BE PERMITTED IN THE INITIAL BACKFILL
MEASURED 6" FROM THE TOP OF PIPE. THE REMAINDER OF TRENCH
CAN BE FILLED WITH MATERIAL SCREENED 2" MINUS.
i FINISH GRADE
TRENCHING
LATERAL LINE
GRANULAR BACKFILL
MAINLINE
CONTROL WIRES
CLEAN BACKFILL
G
H
BOX TO BE PLACED AT RIGHT ANGLE TO
HARDSCAPE EDGE w/ VALVE # ETCHED IN LID
12"X18" PLASTIC BOX AND COVER WITH
LOCK TOP
CURL TYPE EXPANSION LOOP (MIN.24")
WATERPROOF WIRE CONNECTION
CHRISTY'S I.D TAG (STANDARD)
SECURE TO SOLENOID PIGTAIL
FINISH GRADE �3/4"
TIC
12 MAX. TOP le fr
OF VALVE 'OLNOIDi1Y
V(z(b04f F PE
18" MIN j / NOLINN-PRESSURE
J UNION CONNECTION
if
PEA GRAVEL
e (MIN.3 CU. FT.)
PVC LINE PIPE VC SCH. 40 MALE ADAPTOR
PVC ELBOW (TYP. 2 PLACES)
PVC LINE PIPE
COMMON WIRE PVC SUPPLY LINE FITTINGS(SXSXS)
CONTROL WIRE
NOTES:
1. VALVES ARE TO BE INSTALLED IN SHRUB AREAS UNLESS OTHERWISE NOTED
2. WHEN MORE THAN ONE VALVE IS LOCATED IN THE SAME AREA. PROVIDE A SPACE A MIN. OF 3 FT. APART.
3. USE TEFLON TAPE ON ALL THREADED FITTINGS.
4. ONE VALVE PER VALVE BOX
REMOTE CONTROL VALVE
-TORO NETWORK 8000
IRRIGATION CONTROLLER
INSIDE STRONG BOX
ENCLOSURE SB-24SS
01
CONDUIT WITH 115V POWER
CONDUCTORS PER LOCAL &
NATIONAL ELECTRICAL CODES
CONDUIT FOR COMMUNICATION
CONDUIT FOR GROUND
CONDUIT FOR VALVES
AND SENSOR WIRES
FINISHED SURFACE
SLOPE TO DRAIN
2"
8" MIN.
SEE SPECS.
CONCRETE FOOTING/SLAB
TO RECEIVE CABINET/
ENCLOSURE WITH #4
SEE SPECS.TT REBARS HORIZONTALS AT
12" 0. C.
6"6
MIN. MIN. MIN
MIN.
FRONT RIGHT -SIDE
SECTION/ELEVATION SECTION/ELEVATION
NOTES: 1. ALL POWER WIRES, GROUND WIRES, ETC. SHALL BE SEPARATELY SLEEVED AND SWEPT
THROUGH ENCLOSED PAD WITH SCH. 40 RIGID CONDUIT. ALL SLEEVING SHALL BE A
MINIMUM OF 18" BELOW FINISH GRADE.
2. PROVIDE A 5/8"X10' DRIVEN GROUND ROD (1990 NEC ART 250-81)IN A 8" DIA. X 12"
WELL (BOTTOMLESS) AND FILLED WITH PEA GRAVEL.
TORO CONTROLLER
FINISH GRADE
SCH.80 PVC RISER
- SAME SIZE AS
SPRINKLER HEAD,,
INLET.
INSTALL HEAD 3/4" ABOVE FINISH GRADE TYP.
IN TURF AREAS AND 1-1/2" IN GROUND COVER/
SHRUB AREAS.
12" POP-UP SPRAY HEAD.
REFER TO LEGEND FOR
NOZZLE. INSTALL PLUMB
AND UNIFORM THRU-OUT.
PVC ELLS SCH. 80
PVC SCH 40 LATERAL LINE
'-SCH 80 PVC TRIPLE SWING JOINT ASSEMBLY.
NOTE: SAME SIZE AS SPRINKLER HEAD INLET.
1. TILT SPRAY HEAD TO BEST SUIT SITE CONDITION
AND PROVIDE PROPER COVERAGE.
2. USE TEFLON TAPE ON ALL MALE PIPE THREADS.
3. INSTALL HEADS PLUMB AND UNIFORM THRU-OUT PROJECT
I HI -POP SHRUB SPRAY
Q O REV. REVISION DESCRIPTION DATE ENGR. CITY DATE
I A S -BUILT1 9 p MP_ A(l
CL
TOLL FREE 1-800-227-2600
A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT
C
F
PRESSURE CONC, STABILIZER' R O N T PRESSURE -
SUPPLY LINE (TRUST BLOCK)
(INTAKE) (DISCHARGE)
BACKFLOW ENCLOSURE
,,,-3/4' GRAVEL (SEE NOTE BELOW)
BRASS ELBOW
PRESSURE REGULATOR IF
REQUIRED. SET AS SHOWN
REDUCE PRESSURE
BACKFLOW PREVENTER
:N ON SITE DRAWING
STRAINER #40 BRASS NIPPLE
PLAN
MESH MODEL (4 PLACES)
WIRE C❑NNECTI❑NS
BRASS ELBO BRASS ELBOW
BRASS UNION
FONTANA METER/CONTROLLER.
RELIEF PORT BRASS PIPE
12"OR
BRASS BALL i BRASS BALL
VALVE LOOSE KEY
VALVE
AS NOTED y HARDSCAPE
AS
HOSE BIB
L
BRASS PIPE LOCK BOX
I
STATION CONTROLLER -
4jr8" #4 REBAR
RED
18" 18".
a
a
- FOOTING/FOUNDATION
12 MAX. TOP le fr
OF VALVE 'OLNOIDi1Y
V(z(b04f F PE
18" MIN j / NOLINN-PRESSURE
J UNION CONNECTION
if
PEA GRAVEL
e (MIN.3 CU. FT.)
PVC LINE PIPE VC SCH. 40 MALE ADAPTOR
PVC ELBOW (TYP. 2 PLACES)
PVC LINE PIPE
COMMON WIRE PVC SUPPLY LINE FITTINGS(SXSXS)
CONTROL WIRE
NOTES:
1. VALVES ARE TO BE INSTALLED IN SHRUB AREAS UNLESS OTHERWISE NOTED
2. WHEN MORE THAN ONE VALVE IS LOCATED IN THE SAME AREA. PROVIDE A SPACE A MIN. OF 3 FT. APART.
3. USE TEFLON TAPE ON ALL THREADED FITTINGS.
4. ONE VALVE PER VALVE BOX
REMOTE CONTROL VALVE
-TORO NETWORK 8000
IRRIGATION CONTROLLER
INSIDE STRONG BOX
ENCLOSURE SB-24SS
01
CONDUIT WITH 115V POWER
CONDUCTORS PER LOCAL &
NATIONAL ELECTRICAL CODES
CONDUIT FOR COMMUNICATION
CONDUIT FOR GROUND
CONDUIT FOR VALVES
AND SENSOR WIRES
FINISHED SURFACE
SLOPE TO DRAIN
2"
8" MIN.
SEE SPECS.
CONCRETE FOOTING/SLAB
TO RECEIVE CABINET/
ENCLOSURE WITH #4
SEE SPECS.TT REBARS HORIZONTALS AT
12" 0. C.
6"6
MIN. MIN. MIN
MIN.
FRONT RIGHT -SIDE
SECTION/ELEVATION SECTION/ELEVATION
NOTES: 1. ALL POWER WIRES, GROUND WIRES, ETC. SHALL BE SEPARATELY SLEEVED AND SWEPT
THROUGH ENCLOSED PAD WITH SCH. 40 RIGID CONDUIT. ALL SLEEVING SHALL BE A
MINIMUM OF 18" BELOW FINISH GRADE.
2. PROVIDE A 5/8"X10' DRIVEN GROUND ROD (1990 NEC ART 250-81)IN A 8" DIA. X 12"
WELL (BOTTOMLESS) AND FILLED WITH PEA GRAVEL.
TORO CONTROLLER
FINISH GRADE
SCH.80 PVC RISER
- SAME SIZE AS
SPRINKLER HEAD,,
INLET.
INSTALL HEAD 3/4" ABOVE FINISH GRADE TYP.
IN TURF AREAS AND 1-1/2" IN GROUND COVER/
SHRUB AREAS.
12" POP-UP SPRAY HEAD.
REFER TO LEGEND FOR
NOZZLE. INSTALL PLUMB
AND UNIFORM THRU-OUT.
PVC ELLS SCH. 80
PVC SCH 40 LATERAL LINE
'-SCH 80 PVC TRIPLE SWING JOINT ASSEMBLY.
NOTE: SAME SIZE AS SPRINKLER HEAD INLET.
1. TILT SPRAY HEAD TO BEST SUIT SITE CONDITION
AND PROVIDE PROPER COVERAGE.
2. USE TEFLON TAPE ON ALL MALE PIPE THREADS.
3. INSTALL HEADS PLUMB AND UNIFORM THRU-OUT PROJECT
I HI -POP SHRUB SPRAY
Q O REV. REVISION DESCRIPTION DATE ENGR. CITY DATE
I A S -BUILT1 9 p MP_ A(l
CL
TOLL FREE 1-800-227-2600
A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT
C
F
PRESSURE CONC, STABILIZER' R O N T PRESSURE -
SUPPLY LINE (TRUST BLOCK)
(INTAKE) (DISCHARGE)
BACKFLOW ENCLOSURE
,,,-3/4' GRAVEL (SEE NOTE BELOW)
BRASS ELBOW
NOTES 1. BACKFLOW ENCLOSURE, LE MEUR
OR EQUAL 24'X60'X36' HIGH
HINGED AT ONE END SECURE TO
6'X8' FOOTING W/4' J BOLTS
(EQUIPMENT TO BE CENTERED
INSIDE HOUSING) - POWDER -COATED
FOREST GREEN COLOR.
BRASS UNION
BRASS BALL
VALVE
#4 REBAR
END
zm
2. CONTRACTOR SHALL FORM ENCLOSURE BASE
AND REQUEST INSPECTION PRIOR TO POURING
F❑❑TING FOUNDATION,
3. CONTRACTOR SHALL USE 520-C-2500 CONCRETE.
BACKFLOW PREVENTER
2'-5" 2' LEGEND
1 STAINLESS STEEL ENCLOSURE
STRONG BOX MODEL SB-24SS/120V
h 8 2 8" X 8" METER WINDOW (FACES STREET)
Icc
cc I
9 3 3 METER DOOR
L J
4 4 CONTROLLER DOOR
5 5 STEEL FRAME
5
6 6 6 BOLT FRAME TO CONC. SLAB.
_I
7 FINISHED CONC. SLAB SURFACE
7 8 ELECTRIC METER
SIDE VIEW FRONT VIEW 9 IRRIGATION CONTROL BOARD
NOTES:
1. EXACT LOCATION OF CONTROLLER SHALL BE AGREED UPON BY EDISON, CITY
LANDSCAPE INSPECTOR, AND CONTRACTOR PRIOR TO ANY TRENCHING OR WIRE
PLACEMENT.
2. PROVIDE 100A METER AND 50A/2P MAIN C/B/ WHERE INDICATED.
3. PROVIDE PANEL BOARD WHERE NECESSARY.
4. CONDUIT AND CONDUCTOR SIZES ARE BASED ON NON-METALLIC CONDUIT AND
COPPER CONDUCTORS WITH "THNN/THWN" INSULATION.
5. TERMINATE LINE VOLTAGE SUPPLY AT A "HANDHOLE" PER S.C.E. COMPANY
REQUIREMENTS. VERIFY TERMINATION AND EXACT LOCATION WITH S.C.E. CO.
PRIOR TO TRENCHING.
CONTROLLER ENCLOSURE
TORO SENTINEL CONTROLLER INSTALLED IN AN APROVED STAINLESS STEEL
EDISON METER BOX ENCLOSURE.
SPRINKLER HEAD LEGEND
SYMBOL DESCRIPTION MNFTR. MODEL NOZZLE ARC P.S.I. G.P.M. RADIUS
SHRUB POP-UP SPRAY RAINBIRD 1812 -SAM -PRS 5 SERIES MPR 90 Q 30 .10 5 FT.
SHRUB POP-UP SPRAY RAINBIRD 1812 -SAM -PRS 5 SERIES MPR 180 H 30 .20 5 FT.
r SHRUB POP-UP SPRAY RAINBIRD 1812 -SAM -PRS 8 SERIES MPR 90 Q 30 .25 8 FT,
V SHRUB POP-UP SPRAY RAINBIRD 1812 -SAM -PRS 8 SERIES MPR 180 H 30 .50 8 FT.
SHRUB POP-UP SPRAY RAINBIRD 1812 -SAM -PRS 10 SERIES MPR 90 Q 30 .40 10 FT.
\v SHRUB POP-UP SPRAY RAINBIRD 1812 -SAM -PRS 10 SERIES MPR 180 H 30 .71 10 FT.
SHRUB POP-UP SPRAY RAINBIRD 1812 -SAM -PRS 10 SERIES MPR 360 F 30 1.50 10 FT.
SHRUB POP-UP SPRAY RAINBIRD 1812 -SAM -PRS 12 SERIES MPR 90 Q 30 .50 12 FT.
SHRUB POP-UP SPRAY RAINBIRD 1812 -SAM -PRS 12 SERIES MPR 180 H 30 1.09 12 FT.
SHRUB POP-UP SPRAY RAINBIRD 1812 -SAM -PRS 15 SERIES MPR 90 Q 30.85 15 FT.
V{' SHRUB POP-UP SPRAY RAINBIRD 1812 -SAM -PRS 15 SERIES MPR 180 H 30 1.65 15 FT.
GENERAL IRRIGATION LEGEND
O NEW 2" WATER METERS POINT OF CONNECTION; VERIFY EXACT LOCATIONS IN FIELD.
2" SUPERIOR MASTER VALVES; 3100 SERIES, BRASS, NORMALLY OPEN.
® INSTALL WITH 1-1/2" FLOW SENSOR; DATA INDUSTRIAL IR SERIES, BRASS.
SUPERIOR REMOTE CONTROL VALVE; 950 DW SERIES BRASS; SIZE AS NOTED ON PLAN.
►t NIBCO T-136 SERIES GATE VALVE. LINE SIZE.
RAINBIRD 33DRC 19mm (OR 3/4") QUICK -COUPLING VALVE WITH LOCKING COVER.
FEBCO 825YA 2" REDUCED PRESSURE BACKFLOW PREVENTERS.
INSTALL PER MANUFACTURER'S SPECIFICATIONS AND PER LOCAL CODE.
INSTALL WITH VANDAL -RESISTANT STEEL ENCLOSURE BY LEMEUR OR EQUAL.
-- SCHEDULE 40 PVC MAINLINE; SIZE AS NOTED ON PLAN; BURY 18" MINIMUM BELOW F.G.
CLASS 200 PVC LATERAL LINE; SIZE AS NOTED ON PLAN; BURY MINIMUM 12" BELOW FINISH GRADE.
1
- SCHEDULE 40 PVC SLEEVING; SIZE AS NOTED ON PLAN; EXTEND 12" BEYOND EDGE OF PAVING.
TORO SENTINEL SATELLITE CONTROLLER - 12, 24 or 36 STATIONS AS NOTED ON PLANS
SSA -K-(12, 24 or 36)-PS1-6-N-5-4
VERIFY EXACT LOCATION WITH AGENCY'S REPRESENTATIVE.
CONTROLLER TO BE INSIDE STEEL ENCLOSURE BY V.I.T. STRONG BOX.
STATION #
VALVE SIZE
GALLONS PER MINUTE
NOTE: DRAWN LOCATIONS OF IRRIGATION EQUIPMENT ON PLANS ARE DIAGRAMMATIC FROM
ACTUAL LOCATIONS FOR CLARITY PURPOSES.
0
m]
IRRIGATION LEGENDS
VALVE BOX W/LOCK
FINISH GRADE
u
I,,�_,IIIII,,II-III 11III=111.,,1111;11111;,
BRASS li PVC MALE ADAPTOR
GATE VALVE
I 2" x 4" CONC. BLOCK
MAINLINE
GATE VALVE
WHITE
(COMMON)
BLUE
1 CU. FT. PEA GRAVEL
OF 14
WIRES
WATERPROOF ALL
12'
PLAN
12•
NOTES 1. BACKFLOW ENCLOSURE, LE MEUR
OR EQUAL 24'X60'X36' HIGH
HINGED AT ONE END SECURE TO
6'X8' FOOTING W/4' J BOLTS
(EQUIPMENT TO BE CENTERED
INSIDE HOUSING) - POWDER -COATED
FOREST GREEN COLOR.
BRASS UNION
BRASS BALL
VALVE
#4 REBAR
END
zm
2. CONTRACTOR SHALL FORM ENCLOSURE BASE
AND REQUEST INSPECTION PRIOR TO POURING
F❑❑TING FOUNDATION,
3. CONTRACTOR SHALL USE 520-C-2500 CONCRETE.
BACKFLOW PREVENTER
2'-5" 2' LEGEND
1 STAINLESS STEEL ENCLOSURE
STRONG BOX MODEL SB-24SS/120V
h 8 2 8" X 8" METER WINDOW (FACES STREET)
Icc
cc I
9 3 3 METER DOOR
L J
4 4 CONTROLLER DOOR
5 5 STEEL FRAME
5
6 6 6 BOLT FRAME TO CONC. SLAB.
_I
7 FINISHED CONC. SLAB SURFACE
7 8 ELECTRIC METER
SIDE VIEW FRONT VIEW 9 IRRIGATION CONTROL BOARD
NOTES:
1. EXACT LOCATION OF CONTROLLER SHALL BE AGREED UPON BY EDISON, CITY
LANDSCAPE INSPECTOR, AND CONTRACTOR PRIOR TO ANY TRENCHING OR WIRE
PLACEMENT.
2. PROVIDE 100A METER AND 50A/2P MAIN C/B/ WHERE INDICATED.
3. PROVIDE PANEL BOARD WHERE NECESSARY.
4. CONDUIT AND CONDUCTOR SIZES ARE BASED ON NON-METALLIC CONDUIT AND
COPPER CONDUCTORS WITH "THNN/THWN" INSULATION.
5. TERMINATE LINE VOLTAGE SUPPLY AT A "HANDHOLE" PER S.C.E. COMPANY
REQUIREMENTS. VERIFY TERMINATION AND EXACT LOCATION WITH S.C.E. CO.
PRIOR TO TRENCHING.
CONTROLLER ENCLOSURE
TORO SENTINEL CONTROLLER INSTALLED IN AN APROVED STAINLESS STEEL
EDISON METER BOX ENCLOSURE.
SPRINKLER HEAD LEGEND
SYMBOL DESCRIPTION MNFTR. MODEL NOZZLE ARC P.S.I. G.P.M. RADIUS
SHRUB POP-UP SPRAY RAINBIRD 1812 -SAM -PRS 5 SERIES MPR 90 Q 30 .10 5 FT.
SHRUB POP-UP SPRAY RAINBIRD 1812 -SAM -PRS 5 SERIES MPR 180 H 30 .20 5 FT.
r SHRUB POP-UP SPRAY RAINBIRD 1812 -SAM -PRS 8 SERIES MPR 90 Q 30 .25 8 FT,
V SHRUB POP-UP SPRAY RAINBIRD 1812 -SAM -PRS 8 SERIES MPR 180 H 30 .50 8 FT.
SHRUB POP-UP SPRAY RAINBIRD 1812 -SAM -PRS 10 SERIES MPR 90 Q 30 .40 10 FT.
\v SHRUB POP-UP SPRAY RAINBIRD 1812 -SAM -PRS 10 SERIES MPR 180 H 30 .71 10 FT.
SHRUB POP-UP SPRAY RAINBIRD 1812 -SAM -PRS 10 SERIES MPR 360 F 30 1.50 10 FT.
SHRUB POP-UP SPRAY RAINBIRD 1812 -SAM -PRS 12 SERIES MPR 90 Q 30 .50 12 FT.
SHRUB POP-UP SPRAY RAINBIRD 1812 -SAM -PRS 12 SERIES MPR 180 H 30 1.09 12 FT.
SHRUB POP-UP SPRAY RAINBIRD 1812 -SAM -PRS 15 SERIES MPR 90 Q 30.85 15 FT.
V{' SHRUB POP-UP SPRAY RAINBIRD 1812 -SAM -PRS 15 SERIES MPR 180 H 30 1.65 15 FT.
GENERAL IRRIGATION LEGEND
O NEW 2" WATER METERS POINT OF CONNECTION; VERIFY EXACT LOCATIONS IN FIELD.
2" SUPERIOR MASTER VALVES; 3100 SERIES, BRASS, NORMALLY OPEN.
® INSTALL WITH 1-1/2" FLOW SENSOR; DATA INDUSTRIAL IR SERIES, BRASS.
SUPERIOR REMOTE CONTROL VALVE; 950 DW SERIES BRASS; SIZE AS NOTED ON PLAN.
►t NIBCO T-136 SERIES GATE VALVE. LINE SIZE.
RAINBIRD 33DRC 19mm (OR 3/4") QUICK -COUPLING VALVE WITH LOCKING COVER.
FEBCO 825YA 2" REDUCED PRESSURE BACKFLOW PREVENTERS.
INSTALL PER MANUFACTURER'S SPECIFICATIONS AND PER LOCAL CODE.
INSTALL WITH VANDAL -RESISTANT STEEL ENCLOSURE BY LEMEUR OR EQUAL.
-- SCHEDULE 40 PVC MAINLINE; SIZE AS NOTED ON PLAN; BURY 18" MINIMUM BELOW F.G.
CLASS 200 PVC LATERAL LINE; SIZE AS NOTED ON PLAN; BURY MINIMUM 12" BELOW FINISH GRADE.
1
- SCHEDULE 40 PVC SLEEVING; SIZE AS NOTED ON PLAN; EXTEND 12" BEYOND EDGE OF PAVING.
TORO SENTINEL SATELLITE CONTROLLER - 12, 24 or 36 STATIONS AS NOTED ON PLANS
SSA -K-(12, 24 or 36)-PS1-6-N-5-4
VERIFY EXACT LOCATION WITH AGENCY'S REPRESENTATIVE.
CONTROLLER TO BE INSIDE STEEL ENCLOSURE BY V.I.T. STRONG BOX.
STATION #
VALVE SIZE
GALLONS PER MINUTE
NOTE: DRAWN LOCATIONS OF IRRIGATION EQUIPMENT ON PLANS ARE DIAGRAMMATIC FROM
ACTUAL LOCATIONS FOR CLARITY PURPOSES.
0
m]
IRRIGATION LEGENDS
VALVE BOX W/LOCK
FINISH GRADE
u
I,,�_,IIIII,,II-III 11III=111.,,1111;11111;,
BRASS li PVC MALE ADAPTOR
GATE VALVE
I 2" x 4" CONC. BLOCK
MAINLINE
GATE VALVE
WHITE
(COMMON)
BLUE
1 CU. FT. PEA GRAVEL
OF 14
WIRES
CONTROLLER NOTES
SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT
COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL���p P�NDT. SNgpF9P
G`x
SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, W �\
THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO * Exp. 11/30/08
BRING THEM INTO CONFORMANCE WITH CONDITIONS AND qTF OF CAV�F���\�
STANDARDS IN EFFECT.
CMASTER VALVE &
FLOW SENSOR APPROVED BY DATE
Prepared Under The Supervision Of : CITY OF FONTANA, CALIFORNIA
JHA CONSULTING, INC. LANDSCAPE IMPROVEMENTS - IRRIGATION DETAILS
PL.ANN I N G F,NTITLF.M E N T S DRAWN BY:SCALE:
SIERRA AVENUE
L A N D S C A P E A R CHIT E C T U RE JHA
420 EXCHANGE , • SUITE. 100 STA. 56+00 TO STA. 100+00 AS SHOWN
IRVINE, CALIFORNIA • 92602 DESIGNED BY: BASELINE VENUE DATE:
1714)665-4540 • FX (714)379-4440 JHA STA. 23 0 STA. 255+00 OCT. 2006
CHECKED BY: - AP D BY: DRAWING NO.: 71
MICHAEL T HARADA R.L.A. N0. 3848 // D�e JHA CI Y ENGIN R.C.E. 51152 �d .D TE: LD72 L 22
WATERPROOF ALL
CONTACT AQUA FLOW WITH THE
FOLLOWING NUMBERS FOR THE CITY OF
WIRE C❑NNECTI❑NS
FONTANA METER/CONTROLLER.
AS PER STD.
FONTANA PART # FOR A 24
STATION CONTROLLER -
RED
ESB24-U2-MPEA161OK-0131-VRA
BLACK
MASTER C❑NTREL
VALVE
FONTANA PART # FOR A 36
STATION CONTROLLER -
FLOW SENSOR
ESB36-U2-MPEA161OK-OB1-VRA
DIAMETER SAME SIZE
FONTANA PART # FOR A 48
STATION CONTROLLER -
AS FLOW METER SIZE
ESB48-U2-MPEA161 OK-OB1-VRA
MINIMUM DI
TANCE DOWNSTREAM
CONTACTS:
5X DIAMETER OF FLOW METER SIZE
AQUA FLO
MINIMUM DISTANCE UPSTREAM
TOM RADEN
1OX DIAMETER OF FLOW
PHONE # (805) 895-8909
METER SIZE
FAX # (661) 718-0192
AS -BUILT
CITY OF FONTANA
CONTROLLER NOTES
SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT
COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL���p P�NDT. SNgpF9P
G`x
SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, W �\
THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO * Exp. 11/30/08
BRING THEM INTO CONFORMANCE WITH CONDITIONS AND qTF OF CAV�F���\�
STANDARDS IN EFFECT.
CMASTER VALVE &
FLOW SENSOR APPROVED BY DATE
Prepared Under The Supervision Of : CITY OF FONTANA, CALIFORNIA
JHA CONSULTING, INC. LANDSCAPE IMPROVEMENTS - IRRIGATION DETAILS
PL.ANN I N G F,NTITLF.M E N T S DRAWN BY:SCALE:
SIERRA AVENUE
L A N D S C A P E A R CHIT E C T U RE JHA
420 EXCHANGE , • SUITE. 100 STA. 56+00 TO STA. 100+00 AS SHOWN
IRVINE, CALIFORNIA • 92602 DESIGNED BY: BASELINE VENUE DATE:
1714)665-4540 • FX (714)379-4440 JHA STA. 23 0 STA. 255+00 OCT. 2006
CHECKED BY: - AP D BY: DRAWING NO.: 71
MICHAEL T HARADA R.L.A. N0. 3848 // D�e JHA CI Y ENGIN R.C.E. 51152 �d .D TE: LD72 L 22