HomeMy WebLinkAbout4143-1♦ CONDUCTOR TABLE
DIAGRAM
CIRCUIT OR
RUNS
NOT
USED
1
2
3
4 5
6
7
8
9
NOT
USED
AWG.
POLE
PHASE 5
POLE D
1/1
1/1
1/1
1/1 1/1j
MESSAGE
-
w
35'
20'
15'
25OW
B
2
W
MAS
SV -1—T
—
J
POLE
4'
2
TYPE 1—A
10
—
—
—
-/-
—
—
—
TV -1—T
SP-1—CS
—
12'
5'
3
24-4-100
o
POLE/
15$0
25OW
B
—
—
2—MAS
SV -1 —T
SP-1—CS
-
4'
6.5'
F=15'
4
TYPE 1—A
10'
—
—
—
B
6
U
o
POLE
TV -1 —T
—
—
6'
4'.5'
519A-4-100
-
z
15'
250W
B
6
E
MAS
SV -1—T
SP-1—CS
See Below
14'
0
POLEj"-
6
TYPE 1—A
10'
—
—
—
B
8
S
—
TV -1—T
SP-1—CS
—
12'
4'
7
24A-4-100
35'
35'
N
POLE/
B
8
S
2—MAS
SV -1—T
SP-1—CS
See Below
3'
-
F=17'
A,,jYP
1—A—
—
—
—
—
—
—
0
j
POLE
—
2'
4.6'
9
PBB
4'
—
—
—
—
—
—
—
2,
5'
oz
POLE
U
M
POLE/
-
TOTAL
1 /1
1 2
1/3
2/4 2/4
-/-
4/4
3/3
2/2
1 1
10
ILUMINAIRE
1 2
1 2
1 2
1 2 1 -
I -
-
Z 1
2
I-
VIDEO
DET.
VIDEO CABLE
1
1
2
2 -
4
-
1
1
-
OPTICOM CABLE 1
1
1
2
2 1 2
-
2 1
1 1
1
-
CONDUIT SIZE
3!)
)
3'
3!)
3" 3'
3)!
3'
3"
3"
30
♦ - ALL CONDUIT AND CONDUCTORS ARE NEW.
GENERAL NOTES:
All
20
A, 10
1' = 20' 0
PHASE
DIAGRAM
STANDARD***
MASTARMS***
NOT
USED
PED PUSH BT.
PHASE 1
PHASE 2
PHASE 3
PHASE 4
C
TYPE
HT.
NOT
USED
LU M.
H.P.S. V.
PHASE 5
PHASE 6
PHASE 7
PHASE 8
1. TRAFFIC SIGNAL, SIGNING AND STRIPING, AND LIGHTING SHALL CONFORM TO THESE
PLANS, THE SPECIAL PROVISIONS, THE CITY OF FONTANA STANDARD DETAILS, AND
THE STATE OF CALIFORNIA STANDARD SPECIFICATIONS SECTION 86 (DATED MAY
2006) AND STANDARD PLANS (DATED MAY 2006), THE 2006 CALIFORNIA MANUAL
OF UNIFORM TRAFFIC CONTROL DEVICES (M.U.T.C.D.).
2. LOCATION OF ALL UNDERGROUND FACILITIES ARE APPROXIMATE. THE CONTRACTOR
SHALL POTHOLE TO DETERMINE THE EXACT LOCATIONS AND VERIFY ALL CONDITIONS
ON THE JOB SITE. HAND DIG FOUNDATIONS UNTIL CLEAR OF ANY OBSTRUCTIONS.
PHONE UNDERGROUND SERVICE ALERT AT (800) 227-2600, TWO (2) WORKING
DAYS BEFORE DIGGING.
3. ALL PULL BOXES SHALL BE No. 6 AND CONDUIT SHALL BE 2" RIGID METAL UNLESS
OTHERWISE SHOWN.
4. CONTRACTOR SHALL MAKE APPLICATION FOR ELECTRIC SERVICE AND SCHEDULING
WITH SOUTHERN CALIFORNIA EDISON COMPANY WELL IN ADVANCE OF NEED.
5. CONTRACTOR SHALL OBTAIN APPROVAL FROM THE ENGINEER FOR EXACT
EQUIPMENT LOCATIONS PRIOR TO FINAL PLACEMENT. SEE DETAIL THIS SHEET.
6. ALL REQUIRED CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF
FONTANA DEPARTMENT OF ENGINEERING PRIOR TO COMMENCEMENT OF WORK.
7. CONTRACTOR SHALL RELOCATE AND/OR REPLACE LANDSCAPING, SPRINKLERS, AND
SIDEWALK AFFECTED BY THE CONSTRUCTION TO THE SATISFACTION OF THE
ENGINEER.
8. CONTROLLER CABINET SHALL NOT BE SUBJECTED TO WATER FROM SPRINKLERS.
MODIFY SPRINKERS SYSTEMS IF NECESSARY.
9. THE ALIGNMENT OF INTERCONNECT DUCTS SHALL BE AS STRAIGHT AS POSSIBLE.
HOWEVER, WHEN CHANGES IN ALIGNMENT ARE NECESSARY, SWEEPS SHALL HAVE
MINIMUM RADIUS OF 10 FEET.
10. ALL VEHICLE INDICATIONS SHALL BE 12" AND HAVE L.E.D. SIGNAL MODULES. ALL
PEDESTRIAN HEADS SHALL HAVE L.E.D. PEDESTRIAN MODULES & UTILIZE
PEDESTRAIN COUNTDOWN TIMERS.
11. ANY EXISTING TRAFFIC SIGNALS AND LIGHTING SHALL REMAIN IN OPERATION UNTIL
REPLACED WITH NEW CONSTRUCTION.
12. CONTRACTOR TO FURNISH ALL EQUIPMENT, MATERIALS, AND HARDWARE TO
CONSTRUCT THE TRAFFIC SIGNAL AND LIGHTING AS SHOWN ON THE PLANS, EXCEPT
AS NOTED CITY FURNISHED OR LISTED AS CITY PROVIDED IN THE SPECIAL
PROVISIONS.
13. CONTRACTOR SHALL REFER TO THE CITY TRAFFIC ENGINEER IN THE EVENT OF A
CONFLICT OR POTENTIAL CONFLICT WITH THESE PLANS AND,OR SPECIFICATIONS FOR
THIS PROJECT.
14. WHERE TRAFFIC SIGNAL STREET CROSSING CONDUIT ARE NOT INSTALLED USING THE
BORING METHOD, TRENCH REPAIRS SHALL BE PER SPECIAL PROVISIONS, SECTION E.
15. TRAFFIC SIGN SIZE SHALL BE FOR CONVENTIONAL ROADWAYS UNLESS OTHERWISE
SHOWN ON THE PLANS.
MONUMENT SIGN
INSTALL 2"C & #5 PB, FUTURE SIC -
3#8, G. F. C.I . ---\
UPLAND 2
'"2"C, 2,#1O(LIGHTING)-
I ml
3 00
e
1
0
oz
0o
a-
aa_
w
U
w
co
MAST -ARM MOUNTING
CLAMP FOR
MODEL 711 OPTICAL DETECTOR
ADF! T'V
■ POLE SCHEDULE
L
STANDARD***
MASTARMS***
LUMINAIRE
PED PUSH BT.
SIGNAL MOUNTING
S.N.S. ****
PLACEMENT
REMARKS
C
TYPE
HT.
SIG.
LU M.
H.P.S. V.
TYPE
PHASE
QUAD
VEHICLE
POLE
PED.
MESSAGE
1
19A-4-100
35'
20'
15'
25OW
B
2
W
MAS
SV -1—T
—
See Below
10'
4'
2
TYPE 1—A
10
—
—
—
B
—
—
—
TV -1—T
SP-1—CS
—
12'
5'
3
24-4-100
30'
35'
15$0
25OW
B
—
—
2—MAS
SV -1 —T
SP-1—CS
See Below
4'
6.5'
F=15'
4
TYPE 1—A
10'
—
—
—
B
6
E
—
TV -1 —T
—
—
6'
4'.5'
519A-4-100
35'
20'
15'
250W
B
6
E
MAS
SV -1—T
SP-1—CS
See Below
14'
3'
6
TYPE 1—A
10'
—
—
—
B
8
S
—
TV -1—T
SP-1—CS
—
12'
4'
7
24A-4-100
35'
35'
15'
250W
B
8
S
2—MAS
SV -1—T
SP-1—CS
See Below
3'
8'
F=17'
A,,jYP
1—A—
—
—
—
—
—
—
T —1—T
— —
—
2'
4.6'
9
PBB
4'
—
—
—
—
—
—
—
2,
5'
■ ALL EQUIPMENT IS --NEW.- -" - -
* SPECIAL ORDER SIGNAL MASTARM
TO FIT STANDARD TYPE 19-4-100
** STRAIGHT LUMINAIRE MAST ARM
*** CITY FURNISHED
**** CONTRACTOR FURNISHED S.N.S. TO BE
INSTALLED ON A SHAFT MOUNTED MAST
ARM SUPPLIED BY THE CONTRACTOR.
I o
W m m
`I
W � I
7
Q O' I 30' I �`
I I�
13' 11' 1 I 11' 13' MONUMENT SIGN
O(PROTECT IN PLACE)
F=17' 7
7
g 5 9 EX. PLANTER (TO REMAIN)
a whi - "*, jr -,
ADEL TV
O
MONUMENT SIGN)
19
W
a
IMIIZ
Curb/Berm flow lir
or edge of should(
v AVENUE
.8P
05 02 4 0
08 j
R3-4
7 R3-4 \ 10 00
_ I ..
5
8 R9 ! 00
-3b
R3- 9 6
7 3-4 �� --- - -
4
5 I
20,
I
R9-36 /
8
R9-31)
F=1CD
- -- --- - -- --
I;
13' 11' 1 11' 13'
I
I
= D I
m
i
I
ADED
��4� `.
30 �O II
_ I ! 175"
10 Q Juniper Ave
�O
3 , Upland
Ave
X6600
5 0 Juniper s2oo Q
"B" (D Upland �sioo
�°ate
BCR s �_
Q
J
SIGNAL STANDARD PLACEMENT DIMENSIONS Q
LEGEND:
►� - IMAGE SENSOR UNIT. Q
r�
- UNI -DIRECTIONAL, SINGLE CHANNEL OPTICAL DETECTOR. v
v
CONSTRUCTION NOTES:
NOTE: SEE SPECIAL PROVISIONS FOR ANY CITY SUPPLIED EQUIPMENT AND/OR MATERIALS. Q
INSTALL CITY FURNISHED TYPE 90 CONTROLLER EQUIPMENT PACKAGE INCLUDING TYPE "R" CABINET,
SOLO PRO VIDEO DETECTION, BATTERY BACKUP, AND APPURTENANT EQUIPMENT. CONTROLLER
CABINET AND FOUNDATION SHALL BE INSTALLED PER CITY STANDARD DRAWING 4001. CONTRACTOR
SHALL FURNISH AND INSTALL ANY ADDITIONAL ELECTRONIC EQUIPMENT REQUIRED TO PROVIDE THE
SIGNAL OPERATION AS SHOWN ON THE PLAN.
aFURNISH & INSTALL TYPE III -BF SERVICE EQUIPMENT ENCLOSURE PER CITY OF FONTANA AND
SOUTHERN CALIFORNIA EDISON COMPANY REQUIREMENTS. I ,
FURNISH AND INSTALL 3" PVC CONDUIT WITH 1/4" POLY PULL ROPE PER SCE REQUIREMENTS.
{ COORDINATE SERVICE WITH SCE (CHRIS LORIMER 909-357-6221)
�4 INSTALL CITY FURNISHED IMAGE SENSOR UNIT AS DIRECTED BY THE ENGINEER.
Q
INSTALL CITY FURNISHED UNI -DIRECTIONAL, SINGLE CHANNEL OPTICOM DETECTOR (MODEL 711 OR
D EQUAL) PER DETAIL ON THIS SHEET AND AS DIRECTED BY THE ENGINEER. Q
17-11 EXISTING MAIL GGEL:EeTION BOX TE) BE REEE)eATEE) BY U.S.P.S., PER STREET IMPROVEMENT PLAN
❑7 FURNISH AND INSTALL MAST ARM MOUNTED SIGN AS INDICATED.
�8 FURNISH AND INSTALL SIGN, AS INDICATED.
Al 9 EXISTING POWER POLE TO BE RELOCATED BY SCE, PER STREET IMPROVEMENT PLAN I 1
FI -11 UNDERGROUND
FAeI ITIESTe BE RE06A T���V 1 ITII ITY (30 IPA AIV
EXISTING POWER POLE TO BE REMOVED BY ,
PER STREET- IMPROVEMENT PEAN.Q
2_
AUTOCAD FILENAME: JUNIPER. UPLAN D.TS-RD.