Loading...
HomeMy WebLinkAbout4122-1.GENERAL NOTIES 1. ADVANCE CONSTRUCTION SIGNING INDICATING DURATION OF PROJECT SHALL BE IN PLACE ONE WEEK PRIOR TO IMPLEMENTING DETOURS. 2. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVELOPMENT DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC RIGHT—OF—WAY WITHIN THE CITY. CALL (909) 350-7610. 3. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND PROCEDURES DESCRIBED IN THE MUTCD 2003 CALIFORNIA SUPPLEMENT SECTION 6 UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER. 4. THE CONTRACTOR SHALL NOTIFY THE CITY TRAFFIC SECTION TWO WORKING DAYS PRIOR TO IMPLEMENTING THE TRAFFIC CONTROL PLAN TO ALLOW CITY STAFF TIME TO ADJUST TRAFFIC SIGNAL DETECTION. 5. THE CONTRACTOR SHALL MAINTAIN TWO WAY TRAFFIC AT ALL TIMES UNLESS OTHERWISE APPROVED,.. BY THE CITY TRAFFIC ENGINEER. QUALIFIED FLAGGERS SHALL BE USED WHEN THE ROADWAY IS REDUCED TO A SINGLE LANE OR WHERE TRAFFIC MUST STOP FOR MOVEMENT OF EQUIPMENT. 6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS OR SCALE: 1"=40 OTHER TRAFFIC CONTROL DEVICES AT ALL TIMES. T 7. THE WORK ZONE SHALL BE ROUTINELY INSPECTED AND MAINTAINED TO ENSURE PROPER VISIBILITY AND OPERATION OF ALL TRAFFIC CONTROL AND ADVANCE WARNING DEVICES. — — — — — — — — — — — — F 8. ALL EXISTING SIGNS, STRIPING OR PAVEMENT MARKINGS THAT ARE IN CONFLICT AND/OR NO LONGER N O APPLICABLE SHALL BE REMOVED BY SANDBLASTING. w z O a 9. SIGNS SHALL NOT BE PLACED IN EXCESS OF 15 FEET FROM THE EDGE OF THE TRAVELLED WAY.- - - - - - - - Z - - - - - - PORTABLE SIGN STANDARDS SHALL BE TIED DOWN OR WEIGHTED TO PREVENT TOPPLING. G20- 2 ° o V) LC) 10. THE EXACT LOCATION OF ALL TRAFFIC CONTROL DEVICES IS SUBJECT TO APPROVAL OF THE CITY TRAFFIC 27 228 229 230 231 232 233 23464? 2 N W ENGINEER. ADDITIONAL WARNING, CONSTRUCTION SIGNS OR TRAFFIC SAFETY EQUIPMENT MAY BE J REQUIRED BY THE CITY TRAFFIC ENGINEER. I Tom- - -�- - - t- - 1256.09 114 ? 56.09' 11. ALL WORK AREAS SHALL BE CLEARLY IDENTIFIED AND DELINEATED WITH CONES, PORTABLE DELINEATORS _ __ AND/OR BARRICADES. ALL CONES OR PORTABLE DELINEATORS SHALL BE A MINIMUM OF 28 INCHES IN HEIGHT. W20-1 W21 -5b 5C30A(CA)I W1-8(LT) C30A(CA)I (n 0 SPACING SHALL BE 50', UNLESS OTHERWISE NOTED. M ,n 12. TRAFFIC SIGN DIMENSIONS, COLOR AND LETTERING SHALL CONFORM TO THE 2003 MUTCD AND CALIFORNIA Li Ljj SUPPLEMENT. SIGN CODES SHOWN HEREON ARE TO CONFORM TO 2003 MUTCD AND CALIFORNIA SUPPLEMENT. + z iM TRAFFIC SIGN SIZE SHALL BE FOR CONVENTIONAL ROADWAYS UNLESS OTHERWISE SHOWN ON THE PLANS. 00 N INSTALL DETAIL J f 13. TEMPORARY STRIPING SHALL BE PAINT, 2 COATS.500' 500' a� �) = W 14. ALL FLASHING YELLOW WARNING LIGHTS SHALL BE TYPE "A" PORTABLE, LENS DIRECTED, ENCLOSED AND Iola�� BASELINEITYPE II BARRICADE AVENUE MOUNTED AT A MINIMUM HEIGHT OF THREE FEET, MEASURED FROM THE BOTTOM OF THE LENS TO THE UNDERLYING SURFACE. Q TYPE III BARRICADE (WITH FLASHERS) 15. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES. A PORTABLE DELINEATOR GLUE DOWN MINIMUM 12 FOOT LANE SHALL BE MAINTAINED AT ALL TIMES IN THE CONSTRUCTION AREA FOR RESIDENTS ( ) AND EMERGENCY VEHICLES. CROSS REFERENCES: ® FLASHING ARROW BOARD 16. UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING, STRIPING, BARRICADES, SIGNING AND STRIFING PLANS 4,5 OF 5 AND OTHER TRAFFIC CONTROL DEVICES TO THE SATISFACTION OF THE CITY TRAFFIC ENGINEER, AND INSTALL SEWER IMPROVEMENT PLANS 5,6 OF 6 WORK AREA SIGNING AND STRIPING PER THE SIGNING AND STRIPING PLANS. STORM DRAIN IMPROVEMENT PLANS 1,2 OF 12 17. ALL SIGNS SHALL BE REFLECTORIZED. TRAFFIC SIGNAL MODIFICATION PLAN 2 OF 3 WORK AREA - USING DAILY LANE CLOSURES COMMUNICATION CONDUIT PLAN 1 OF 3 18. CONTRACTOR TO CONTACT TIM RASTEDT AT (909) 350-6649 TWO WORKING DAYS PRIOR TO ANY SIGN STREET IMPROVEMENT PLANS 13,19,20 OF 29 -00- DIRECTION OF TRAVEL INSTALLATION TO ALLOW CITY STAFF TO LOCATE EXISTING UNDERGROUND FACILITIES. TRAFFIC CONTROL (PHASE 2) 3 OF 20 (PHASE 3) 4,5 OF 20 � TEMPORARY K -RAIL (WITH REFLECTIVE TABS) 19. ALL W20-1 AND G20-2 CONSTRUCTION SIGNS SHALL REMAIN IN PLACE FOR THE DURATION OF THE PROJECT, - (PHASE 4) 6 OF 2G UNLESS OTHERWISE SHOWN TO BE RELOCATED ON THESE PLANS OR AS DIRECTED BY THE ENGINEER IN THE FIELD. (PHASE 5) 7 OF 20 >= TEMPORARY CRASH CUSHIONS, ARRAY AS NOTED. 20. CONTRACTOR SHALL MAINTAIN PEDESTRIAN ACCESS AT ALL TIMES. WHEN PEDESTRIAN ACCESS CAN NO LONGER BE MAINTAINED (PHASE 6 8, 9.10 OF 20 4 SIGN AND POST DUE TO CONSTRUCTION, CONTRACTOR SHALL INSTALL "SIDEWALK CLOSED" AND "SIDEWALK CLOSED AHEAD" SIGNS AT (PHASE 7) 12,13,14 OF 20 LOCATIONS AS DIRECTED BY THE ENGINEER IN THE FIELD. (PHASE 8) 16,17,19 OF 20 HIGH LEVEL WARNING DEVICE W20-1 0-1 ' 20-2PA PEDESTRIAN ACCESS, SEE GENERAL NOTE 20. O O L0 _ U N — Iry LdQ (n > O W m Z Q J = W U W U) Q BASELINE NOTE TO CONTRACTOR: Traffic Control shown hereon is concept only. Traffic lanes may have to be modified per Contractor's schedule or construction methods. Contractor shall submit detailed traffic control plans for approval by the City Traffic Engineer ten (10) working days in advance of any proposed modification to these plans or construction phasing. SIERRA AVENUE G20-2 T Z SIERRA AVENUE W20-1 TOLL FREE -qmmmw-1 - 800- 227- 2600 A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT Iv — INSTALL DETAIL KCA) INSTALL TYPE ARROW INSTALL DETAIL 22 4 W20-1 -4 -- --=- G20-2 R3--7 AVENUE REV. REVISION DESCRIPTION DATE ENGR. CITY DATE I SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND CARRIED FORTH INA DILIGENT MANNER, THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO BRING THEM INTO CONFORMANCE WITH CONDITIONS AND STANDARDS IN EFFECT. SCALE: 1"=40' STREET IMPROVEMENTS FESS/ pPrepared Under The Supervision of : CITY OF FONTANA, CALIFORNIA � QRp,1,� S\Ei3 KygylB10 SIERRA AVE AND BASELINE AVE IMPROVEMENTS ~SCALE: :e)No 37 DRAWN B6: TRAFFIC CONTROL - PHASE 1 1•=4-O O6/30%6 2001 East First Street DESIGNED BY: DATE: Santa Ana, CA 92705 BB BASELINE AVENUE 07/31 /06 CIVIL �Q' TEL: (714)568-7300 FAX: (714)836-5906 CHECKED BY; APPROVED BY: DRAWING NO.: 9� CF' CA, AF 4�L84S/4 41222 Date CITY TRAFFIC ENGIN R.C.E. 68819 DATE: 20