Loading...
HomeMy WebLinkAbout4073-2T 23 TO ®=01a, -a 0 0 1 9 [oil [oil rm0m1 r11w 3 11 10 TO 4 12 0 EO 5 3 13 3 of 8 -IRRIGATION PLAN 5 of 8 -PLANTING PLAN SCALE: 1' = 50' RR I cSAT I ON NOTES I -INSTALL ALL IRRIGATION COMPONENTS ACCORDING TO LOCAL CODES # ORDINANCES. 2 -THE CONTRACTOR SHALL OBTAIN, COORDINATE AND PAY FOR ANY AND ALL PERMITS AND ALL INSPECTIONS AS REQUIRED. 5 -THE CONTRACTOR SHALL BE RE5PON51BLE AND LIABLE FOR ANY ENCROACHMENT INTO ADJACENT PROPERTY, R.O.W.'S, EASEMENTS SETBACKS OR ANY OTHER LEGAL PROPERTY RESTRICTIONS EITHER MARKED OR UNMARKED. 4 -IT SHALL BE THE RE5PON51 BI L I TY OF THE CONTRACTOR TO FAMILIARIZE HIMSELF WITH ALL UNDERGROUND UTILITIES. CONTRACTOR SHALL REPAIR/REPLACE AT NO ADDITIONAL COST TO THE OWNER, ANY DAMAGE TO UNDERGROUND UTILITIES THAT MAY OCCUR. 5 -THE CONTRACTOR SHALL BE RESPONSIBLE AND LIABLE FOR ANY AND ALL DAMAGE DUE TO OPERATIONS OR NEGLECT TO WORK OF OTHER CONTRACTORS, EX15TINO AND NEW PLANT MATERIALS OR ANY OTHER PHYSICAL ELEMENTS EITHER MARKED OR UNMARKED. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION OF ACTIVITIES WITH ALL OTHER TRADES. &-THE CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS SHOWN ON PLANS AT THE SITE PRIOR TO COMMENCEMENT OF ANY WORK. ALL DISCREPANCIES SHALL BE REPORTED TO THE OWNER AND PROJECT LANDSCAPE ARCHITECT FOR DIRECTION IMMEDIATELY. ANY CONTINUATION OF WORK IS AT THE CONTRACTOR'S RISK AND EXPENSE. 7 -THE CONTRACTOR SHALL VERIFY THE STATIC PRESSURE, METER SIZE, SIZE OF SERVICE TO THE METER. ANY DEVIATIONS FROM ME51ON CRITERIA SHALL BE BROUGHT TO THE ATTENTION OF THE PROJECT LANDSCAPE ARCHITECT. CONTINUATION OF WORK WITHOUT NOTIFICATION TO THE CONTRACTING OFFICER SHALL BE AT THE CONTRACTORS RISK AND EXPENSE FLANTI N6 NOTES I -CONTRACTOR 15 RESPONSIBLE FOR MAKI N& HIMSELF FAMILIAR WITH ALL UNDERGROUND UTILITIES, PIPES AND STRUCTURES. CONTRACTOR SHALL TAKE SOLE RESPONSIBILITY FOR ANY COST INCURRED DUE TO DAMAGE OF SAID UTILITIES. 2 -DO NOT WILLFULLY PROCEED WITH CONSTRUCTION AS DE516NED WHEN IT IS OBVIOUS THAT UNKNOWN OBSTRUCTIONS, AREA DISCREPANCIES AND/OR GRADE DIFFERENCES EXIST THAT MAY NOT HAVE BEEN KNOWN DURING DE51&N. SUCH CONDITIONS SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE OWNER AND THE CITY. THE CONTRACTOR SHALL A55UME FULL RESPONSIBILITY FOR ALL NECESSARY REVISIONS DUE TO FAILURE TO GIVE SUCH NOTIFICATION. 5 -CONTRACTOR SHALL BE RESPONSIBLE FOR ANY COORDINATION WITH SUBCONTRACTORS AS REQUIRED TO ACCOMPLISH PLANTING OPERATIONS. 4 -SEE DETAILS AND SPECIFICATIONS FOR STAKING METHOD, PLANT PIT DIMENSIONS AND BACKFILL REQUIREMENTS. 5 -UPON COMPLETION OF INSTALLATION, A MAINTENANCE PERIOD OF NINETY MO) DAYS IS REQUIRED PRIOR TO FINAL ACCEPTANCE OF THE WORK BY THE OWNER. MAINTENANCE SHALL INCLUDE MOWING, WEEDING, IRRIGATION, PRUNING, RAISING TREE ROOT BALLS WHICH SETTLE BELOW GRADE, FERTILIZIN6 AND APPLYING SUCH SPRAYS AS ARE NECESSARY FOR PROPER CARE AND UPKEEP. MAINTENANCE ALSO INCLUDES ALL REPAIRS, REPLACEMENT, GLEANING AND ADJUSTIN6 NECESSARY TO KEEP THE IRRIGATION SYSTEM IN GOOD WORKING ORDER WITH PROPER COVERAGE. COMMENCEMENT DATE FOR THE MAINTENANCE PERIOD SHALL BE APPROVED IN WRITING BY THE OWNER'S INSPECTOR MAINTENANCE PERIOD SHALL BE ADEQUATE TO VERIFY PLANT CHARACTERISTICS AND ESTABLISHMENT. 6 -ALL PLANT MATERIAL SHALL BE APPROVED FOR QUALITY BY THE OWNER t LANDSCAPE ARCHITECT PRIOR TO INSTALLATION. 7 -FINAL LOCATION OF ALL PLANT MATERIAL SHALL BE SUBJECT TO THE APPROVAL OF THE OWNER'S REPRESENTATIVE AND THE CITY. LOCATION SHALL BE APPROVED PRIOR TO EXCAVATION. 8 -ALL TREES LOCATED LE55 THAN 5' FROM ANY WALLS, HARDSCAPE OR PAVING SHALL BE INSTALLED WITH ROOT BARRIERS PER CITY STANDARD DETAIL. PRIOR TO BACKFILLING TREE(5) PLANTING, CONTRACTOR SHALL HAVE OWNER'S REPRESENTATIVE AND THE CITY APPROVE THE ROOT BARRIER INSTALLATION. q -LAND. 0APE CONTRACTOR TO RECEIVE SITE GRADED WITHIN 1/10 OF A FOOT OF FINISHED GRADE. CONTRACTOR SHALL ACCEPT GRADE PRIOR TO COMMENCING WORK. STARTING WORK IMPLIES AN ACCEPTANCE OF GRADE. FINAL GRADES SHALL BE ADJUSTED AS DIRECTED BY OWNER. ALL GRADING SHALL BE COMPLETE PRIOR TO COMMENCEMENT OF PLANTING OPERATIONS. ALL MOUNDS IN PLANT AREAS SHALL NOT EXCEED 5:1 SLOPE. 8 -REFER TO DETAILS 4 SPECIFICATIONS FOR INSTALLATION OF ALL COMPONENTS. q -IRRIGATION PLANS AS DRAWN SHALL BE CON51VEPZD DIAGRAMMATIC. ALL PIPE, VALVES, ETC. SHOWN WITHIN PAVED AREAS ARE FOR PE -516N CLARIFICATION ONLY AND SHALL BE INSTALLED IN PLANTING AREAS WHEREVER POSSIBLE. 10 -ONE CONTROLLER CHART SHALL BE PROVIDED AND APPROVED BY THE CITY REPRESENTATIVE FOR EACH CONTROLLER. THE CHART SHALL BE A BLACKLINE PRINT, AND A DIFFERENT COLOR SHALL BE USED TO SHOW THE AREA OF COVERAGE OF EACH STATION. THE CHART SHALL BE HERMETICALLY SEALED BETWEEN TWO PIECES OF PLASTIC. THE CHART SHALL BE MOUNTED U51N6 VELCRO OR APPROVED EQUAL TYPE OF TAPE INSIDE CONTROLLER CABINET. THESE CHARTS MUST BE COMPLETED AND IN PLACE PRIOR TO FINAL ACCEPTANCE OF WORK BY THE OWNER AND THE CITY. II-ADJU5T ALL HEA05 FOR NO OVER SPRAY ON NON -PLANTED AREAS AND FOR COMPLETE COVERAGE. THI5 SHALL INCLUDE SELECTING THE 5E5T DECREE OF ARC TO FIT THE EXI5TIN6 CONDITIONS. ADJUST FOR PLANT REQUIREMENTS. 12 -CONTRACTOR SHALL COORDINATE LOCATION AND POWER HOOKUP FOR AUTOMATIC IRRIGATION CONTROLLER WITH OWNER'S REPRESENTATIVE AND THE CITY. 15 -THE CONTRACTOR SHALL PROVIDE AND KEEP UP TO DATE A COMPLETE "AS BUILT" SET ON A REPRODUCIBLE MYLAR. ALL WORKS SHALL BE NEAT AND LEGIBLE. CONTRACTOR SHALL CERTIFY REPRODUCIBLE AS TO ACCURACY AND COMPLETENESS. CONTRACTOR SHALL BE RESPONSIBLE FOR UPDATING REPRODUCIBLE AS REQUIRED. 10 -CONTRACTOR SHALL NOTIFY OWNER SEVEN (7) DAYS PRIOR TO COMMENCEMENT OF WORK TO COORDINATE PROJECT INSPECTION SCHEDULES AS REQUIRED BY SPECIFICATIONS. 11 -ALL AREAS NOT PLANTED IN TURF, &ROUND COVER, OR HYDROSEED, WHICH ARE LESS THAN 5:1 SLOPE SHALL RECEIVE; 4" MIN. DEEP OF SPECIFIED MULCH. SUBMIT SAMPLE TO OWNER'S REPRESENTATIVE FOR APPROVAL PRIOR TO APPLICATION. 12 -WEED CONTROL: KILL AND REMOVE ALL EXISTING WEEDS FROM 51TE AREA. FOR PREVENTION OF WEED SEED GERMINATION(WITH HYDROSEED OPTION ONLY) SPRAY ENTIRE PLANTING AREA 501L WITH A PRE -EMERGENT HERBICIDE AS RECOMMENDED AND APPLIED BY AN APPROVED PEST CONTROL ADVISOR AND APPLICATOR MINIMUM OF 60 DAYS BEFORE HYDR05EEDIN6 AND BEFORE ROOTED GROUND COVERS HAVE BEEN PLANTED. THE HERBICIDE SHALL BE APPLIED TO DRY SOIL, THEN, WITHIN ONE HOUR OF APPL I CATION INCORPORATED INTO THE 501L BY IRRIGATION FOR A MINIMUM OF 15 MINUTES. AVOID WATER RUN OFF OR SOIL EROSION AFTER THE PRE -EMERGENT HERBICIDE HAS BEEN APPLIED. COORDINATE HERBICIDE APPLICATION WITH HYDROSEEDIN6 OPERATIONS. 15-501 L TEST: AFTER ALL SOIL HAS BEEN IMPORTED TO THE SITE BUT BEFORE SOIL PREPARATION, THE CONTRACTOR SHALL OBTAIN A 501L TEST FOR AGRICULTURAL SUITABILITY AND FERTILITY PREPARED BY A CAL I FORNI A ASSOCIATION OF AGRICULTURAL LABORATORIES MEMBER. FURNISH I COPY OF TEST RESULTS TO THE CITY AND LANDSCAPE ARCHITECT. 14-501L PREPARATION: THE FOLLOWING SOIL AMENDMENTS SHALL BE FOR BID PURPOSES ONLY. FINAL 501L AMENDMENT TYPES AND QUANTITIES SHALL BE BASED ON SOIL TE5T RECOMMENDATIONS. ROTOTILL THE FOLLOWING AMENDMENTS 6" INTO THE SOIL AT RATES INDICATED PER 1,000 SQUARE FEET: 4 CU. YDS. NITROGEN STABILIZED SAWDUST 120 LB5. GYPSUM 125 L55. &RO POWER PLUS 0' 25' 100'