HomeMy WebLinkAbout4066LT-1CONSTRUCTION NOTES: O QUANTITIES
O INSTALL 22,000 LUMEN STREET LIGHT PER CITY OF FONTANA STD. PLAN NO. 1016. (REFER TO LEGEND) 6 EA.
O INSTALL 9,500 LUMEN STREET LIGHT PER CITY OF FONTANA STD. PLAN NO. 1016. (REFER TO LEGEND) 3 EA.
STREET LIGHT LEGEND
GENERAL NOTES FOR STREET LIGHT PLANS
1. ORNAMENTAL STREET LIGHT POLES SHALL BE MARBLELITE OR APPROVED EQUAL.
2. LUMINAIRE SHALL CONSIST OF COBRA HEAD CUT-OFF LENS ON A 6 FT. OR 8 FT. MAST ARM.
15 FT. MAST ARM REQUIRED FOR STREET LIGHTS ON TRAFFICE SIGNAL POLE INSTALLATIONS.
3. ANY CHANGE IN LOCATION OF STREET LIGHTS FROM THE APPROVED PLANS IS SUBJECT TO
APPROVAL BY THE CITY ENGINEER.
4. SIDEWALK WIDTHS TO BE PER APPROVED STREET IMPROVEMENT PLANS. A MINIMUM OF 4
FEET UNOBSTRUCTED SIDEWALK CLEARANCE REQUIRED BEHIND STREET LIGHT POLE.
5. ALL STREET LIGHTS SHALL BE INSTALLED PER CITY STANDARD PLAN # 1016.
LJ
I 1
U
M
Z:
rn w
+m
153'
192'
.1,
A1) PP
PROPOSED
STREET LIGHT - 22,000 LUMEN
HPSV
14
P
200 WATT;
#20; 30' LUMINAIRE HT.; CASE
1, 8' MAST
—
PROPOSED
STREET LIGHT - 9,500 LUMEN
HPSV
=>
100 WATT;
#10; 27' LUMINAIRE HT.; CASE
1, 8' MAST
O
FUTURE STREET
LIGHT
>
EXISTING STREET
LIGHT
•:7:
GENERAL NOTES FOR STREET LIGHT PLANS
1. ORNAMENTAL STREET LIGHT POLES SHALL BE MARBLELITE OR APPROVED EQUAL.
2. LUMINAIRE SHALL CONSIST OF COBRA HEAD CUT-OFF LENS ON A 6 FT. OR 8 FT. MAST ARM.
15 FT. MAST ARM REQUIRED FOR STREET LIGHTS ON TRAFFICE SIGNAL POLE INSTALLATIONS.
3. ANY CHANGE IN LOCATION OF STREET LIGHTS FROM THE APPROVED PLANS IS SUBJECT TO
APPROVAL BY THE CITY ENGINEER.
4. SIDEWALK WIDTHS TO BE PER APPROVED STREET IMPROVEMENT PLANS. A MINIMUM OF 4
FEET UNOBSTRUCTED SIDEWALK CLEARANCE REQUIRED BEHIND STREET LIGHT POLE.
5. ALL STREET LIGHTS SHALL BE INSTALLED PER CITY STANDARD PLAN # 1016.
LJ
I 1
U
M
Z:
rn w
+m
153'
192'
.1,
A1) PP
11
!!_
W V
z�
12 N89'27'25"E
"-EXIST SEWER C•,
4 N rEXIST CURB & GUTTER
PP GUY WIRE
13
2
14
P
—
------------------
---------
'*—EXIST
=>
wL01
Q0
R W"—EXIST
EXIST. UTILITY EASEMENT CAUTIONI �n
>
R W
EXISTING WATER N
•:7:
CO
Q
Q
PROPOSED R/WJ
a.0
U
PROPOSED R/W
W +
(O N +
+
m
w +
m
CD
(p
2 U
CO
O
<
Ki
+
t\
+
N
+
�
+
F
-
�X (0
"'
� ��
�
c
11 +03.05 ECR '.
MATCHLINE
C�
co
M
M�
LO U
��
(0
U
SEE BELOW LEFT
195'
160'
180'
200'
202'
11
!!_
W V
z�
12 N89'27'25"E
"-EXIST SEWER C•,
4 N rEXIST CURB & GUTTER
PP GUY WIRE
13
2
14
P
—
------------------
---------
=>
wL01
Q0
o
EXIST. UTILITY EASEMENT CAUTIONI �n
>
o
EXISTING WATER N
CO
Q
a.0
+
+
(4
O
C
N
CV
C w
W
2 U
VJ
0
D
rnv
BENCH MARK: BASIS OF BEARINGS:
oa
TOP OF 3/4" I.P. WEST 1 /4 COR. SECTION 28 BASIS OF BEARING IS THE CENTERLINE OF
f T.1S, R.6W. AT THE INTERSECTION OF DAHLIA STREET AS SHOWN BY TRACT MAP
ETIWANDA AVE. AND SANTA ANA STREET. N0. 8554, ON FILE IN BOOK 123 OF MAPS,
ELEVATION 941.95 PAGES 13 THROUGH 17, THEREOF, RECORDS
T� OF SAN BERNARDINO COUNTY, CALIFORNIA,
mo
BEING N89°27'25"E.
2
�o
0
�o
�
n_
/ o
a
171'
ETIWANDA AVENUE
STA 58+00 TO STA 70+00
169'
170'
DAHLIA STREET DAHLIA STREET
15 16 CO 17 18 19 °'
- I -
ER
(EXIST CURB &GUTTER 2 EXIST
rEX STWCURB & GUTTER
FH
WV WV GU Y WIRE WV
UTILITY EASEMENTS
— — — — — — — — — — — — — — — Lr — — — — — — — — — — — —I
CAUTIONI a
EXISTING WATER
^ o I
P FH EXIST R W PP FH XIST R 1
WV
CAUTIONI CAUTION!
EXISTING WATER EXISTING WATER
Underground Service Alert
Call: TOLL FREE
1-800
227-2600
TWO WORKING DAYS BEFORE YOU DIG
150'
20 N89 -27'25"E
-I
N
N
EXIST. STREET LIGHT—_
- 21
I �
I
I
22
7I
NIU
I
EXIST. RAILROAD EASEMENT/�
DAHLIA STREET.10'��
N
STA11 +00 TO STA 23+00 SCALE: 1 "= 40'
wTEREpFESS/pNZ(/V PKAAf-
TABIOLO
SITO N. �, Z
w No.38826 m
Exp. 3-31-09 * L ' ^ Z' ZZ
CME �IZ�yI'fb TA131o�.o VATS
v' 20 40 80 120 1 60 �qrF pFca�_ Fp����
IZG� �SS�G , �Xp• 3-�il 09
SUALL: 1 INCH = 40 FEET
SHOULD CONSTRUCTION OF THE REQUIRED�oQROFESS/otic` KCT CONSULTANTS, INC.
IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS �� F� Civil Engineers - Surveyors - Planners
P.O. Box 5705 Riverside, CA 92517-5705
OF THE DATE OF APPROVAL SHOWN HEREON AND
I
I I
i
23 -
I
I
BOX
CITY OF FONTANA, CALIFORNIA
STREET LIGHT IMPROVEMENT PLANS
cD TERESITO N. TABIOLO r� 4344 Latham St., Suite 200, Riverside, CA 92501 DRAWN BY. DR 03-030 SCALE:
L�jCARRIED FORTH IN A DILIGENT MANNER THE CITY RCE No. 38826 Phone: 951-341-8940 Faxnts.co418945 ND 1"=40'
e-mail: kctinc@kctconsultants.com ETIWANDA AV E N U E
ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO Exp. 3-31-07 =re ar d Under The DESIGNED BY: DATE:
z lercoltn LIRAWIN(p 2 22.08 ?-2 r 3/3 o s p RC A REET 04/12/06
REVISED STREET LIGHT AT STA. 59+09 To BE IN R w. BRING THEM INTO CONFORMANCE WITH CONDITIONS �� clvl� ��� CHECKED BY: OVED : DWC. NC.
/ e OF C A�\F O Date ®• Z!• �. TT
71
REV REVISION DESCRIPTION ATE ENGR. CI DATE AND STANDARDS IN EFFECT. ERESITO N. TABIOLo R.C.E. 38826 ExP. 03 w n 1.3.35-n2 W� CI ENGINEERR.C.E. 51152 DATL 4066 LT