HomeMy WebLinkAbout4065-2A-9
22
1-1/4"
I
PA
I
It
EQUIPMENT LEGEND
SYMBOL
MANUFACTURER/MODEL #
SIZE
DETAIL
NOTES
0
IRRIGATION WATER METER - BY OTHERS
1 1/2"
PER CITY
-
H
NIBCO T585 BALL VALVE 2" & SMALLER
NIBCO WD2000 BUTTERFLY VALVE 2 1/2" & LARGER
LINE SIZE
'C'/4
(2, 3, 5)
O
TORO SENTINAL CONTROLLER INSTALLED IN STAINLESS STEEL EDISON METER BOX
ENCLOSURE: MODEL # ESB36-U2-MPEA161 OK-OB1-VRA CONTACT TOM RADEN AT AQUA
FLO (805) 895-8909 FAX: (661) 718-0192.
16 STA.
'C,D,E'/3
(2, 3, 4)
41-60 WIRES
RAINMASTER EVFM-P200 FLOW SENSOR
1"
'1373
(2,3)
(6)
SUPERIOR 950 -WD ELECTRIC CONTROL VALVE
1"
'A'/3
(1, 2, 3)
m
FEBCO 825Y REDUCED PRESSURE BACKFLOW
2" CLASS 315 PVC MAINLINE - 18" MINIMUM COVER
.52
1.05
NOTE: IRRIGATION WATER METER BY DEVELOPER. DEVELOPER SHALL BE RESPONSIBLE TO SUPPLY WATER METER.
Underground Service Alert
Call: TOLL FREE
1-800
227-2600
TWO WORKING DAYS
BEFORE YOU DIG
OWNER / DEVELOPER:
SILVEROAK
DEVELOPMENT
19100 VON KARMAN SUITE 400
IRVINE, CA 92612
(949) 477-9550 * (949)( 477-9555
BENCHMARK:
B.M. N0. 361
ELEV.= 1365.00
IRRIGATION LEGEND
EQUIPMENT LEGEND
MANUFACTURER/MODEL #
NOZZLE
RAD.
PSI
FLOW (GPM)
DETAIL
NOTES
Q
1"
H
I F
Van
SPRAY HEADS
PIPE
RAINBIRD 1806 -SAM -PRS -5
Q/H
5'
30
.61
41-60 WIRES
1.21
PIPE
SO2
'E" / 3
(6)
#14 PILOT
RAINBIRD 1806 -SAM -PRS -8
Q/H
8'
30
.26
2" CLASS 315 PVC MAINLINE - 18" MINIMUM COVER
.52
1.05
.72/1.19/1.7
'E'l 13
(6)
RAINBIRD 1806 -SAM -PRS -10
Q/H
10'
30
.39
.79
1.58
.75/1.45/2.6
'E" 13
(6)
' SPRAY HEADS
NOT SHOWN
RAINBIRD 1812 -SAM -PRS -5
Q/H
5'
30
.61
1.21
(1) INSTALL BACKFLOW PREVENTER IN GROUND COVER OR SHRUB AREA ONLY AND PARALLEL TO STREET.
'E" 13
(6)
SEQ. #
RAINBIRD 1812 -SAM -PRS -8
Q/HNAN
8'
30
.26
.52
1.05
.72/1.19/1.7
'E" / 3
(6)
VALVE
RAINBIRD 1812 -SAM -PRS -10
Q/H/FNAN
10'
30
.39
.79
1.58
.75/1.45/2.6
'Ell 13
(6)
TO ACHIEVE HEAD TO HEAD COVERAGE. ALL ADJUSTMENTS SHALL BE MADE AT NO ADDITION COST TO THE OWNER.
RAINBIRD 1812 -SAM -PRS -12
Q/H/FNAN
12'
30
.65
1.30
2.60
.65/1.3/2.6
'E" / 3
(6)
RAINBIRD 1812 -SAM -PRS -15
Q/H/FNAN
15'
30
.92
1.85
3.70
.92/1.85/3.7
'E" 13
(6)
IRRIGATION
CONTRACTOR SHALL MAKE POINT OF CONNECTION AT 1 1/2"
WATER METER. INSTALL REDUCED PRESSURE BACKFLOW PER
FONTANA WATER DISTRICT STANDARDS AND EXTEND 2" CLASS
315 PVC MAINLINE TO VALVES PER PLAN.
EXISTING STATIC WATER PRESSURE
SYSTEM DESIGN PRESSURE
PEAK IRRIGATION DEMAND
70 PSI
30 PSI
30 GPM
AUTOMATIC IRRIGATION CONTROLLER, (TORO
ESB36-U2-MPEA16100-OB1-VRA) TO BE INSTALLED INSIDE STAINLESS
STEEL PEDESTAL. SEE DETAIL'C,D','E' SHEET 3.
FOR ELECTRICAL POC, REFER TO ELECTRICAL ENGINEER'S
PLAN.
MARK I BY I DATE
ENGINEER
APPR. DATE
COUNTY
EQUIPMENT LEGEND
1/2"
SYMBOL
1 1/2" SLEEVE
MANUFACTURER/MODEL #
SIZE
DETAIL
2" SLEEVE
NOTES
1"
PIPE
RAINBIRD QUICKCOUPLER '33D' HOUSED IN A 10" ROUND LOCKABLE
21-30 WIRES
1131/4
PIPE
(2,3)
31-40 WIRES
1 1/2"
PLASTIC VALVE BOX
1
41-60 WIRES
2"
PIPE
SO2
61-99 WIRES
SPARE PILOT WIRES, COLOR TO DIFFER FROM SITE WIRING
#14 PILOT
'G'/3
100+ WIRES
(2,3)
_ _ _ _ _ _
_
2" CLASS 315 PVC MAINLINE - 18" MINIMUM COVER
2"
WA
(2,3)
CL 200 PVC NON -PRESSURE LATERAL LINE - 12" MIN. COVER
PLAN SIZE
'A'/4
(2,3)
SCH 80 PVC IRRIGATION PIPE / SCH 40 WIRE SLEEVE - 24" MIN. COVER
SEE CHART
'G73
NOT SHOWN
OF RATED CONTROL WIRE, 12 GA COMMON, 14 GA PILOT - 18" MIN. COVER
12/14 GA
(1) INSTALL BACKFLOW PREVENTER IN GROUND COVER OR SHRUB AREA ONLY AND PARALLEL TO STREET.
SEQ. #
(2) PIPES AND VALVES ARE SHOWN IN HARDSCAPE FOR CLARITY ONLY.
FLOW
(3) ALL MAINLINE TEES AND 90'S ARE TO BE SCH 40 PVC.
GPM
(4) COORDINATE ELEC. POINT OF CONNECTION WITH ELECTRICAL CONTRACTOR.
VALVE
(5) VALVES TO TO BE HOUSED IN A 10" ROUND LOCKABLE PLASTIC BOX.
SIZE
(6) CONTRACTOR SHALL ADJUST HEADS WHEN VERTICAL OBJECTS (TREES,FIRE HYDRANTS, STREET LIGHTS, ETC) INTERRUPT
THE SPRAY PATTERN OF THE SPRINKLER. THE CONTRACTOR SHALL INSTALL A QUARTER OR HALF CIRCLE SPRINKLER HEAD
TO ACHIEVE HEAD TO HEAD COVERAGE. ALL ADJUSTMENTS SHALL BE MADE AT NO ADDITION COST TO THE OWNER.
NOTE: ALL VALVE BOX COVERS TO BE CARSON/BROOKS GREEN VALVE BOXES OR EQUAL.
MARK I BY I DATE
ENGINEER
APPR. DATE
COUNTY
PREPARED BY:
d�
DATE:
SCH 40 PVC SLEEVING CHART
1 1/4" SLEEVE
6216 BROCKTON AVE. SU/T£ 212
RIVERSIDE, CALIF. 92506
1/2"
LIC. #1512
1 1/2" SLEEVE
PH. (951) 781-1930
*� a
FAX (95186-8091
PREPARED BY:
d�
DATE:
SCH 40 PVC SLEEVING CHART
1 1/4" SLEEVE
1-4 WIRES
1/2"
PIPE
1 1/2" SLEEVE
5-10 WIRES
3/4"
PIPE
2" SLEEVE
11-20 WIRES
1"
PIPE
2 1/2" SLEEVE
21-30 WIRES
1 1/4"
PIPE
3" SLEEVE
31-40 WIRES
1 1/2"
PIPE
4" SLEEVE
41-60 WIRES
2"
PIPE
6" SLEEVE
61-99 WIRES
2 1/2"/3"
PIPE
8" SLEEVE
100+ WIRES
4"
PIPE
10" SLEEVE
N/A
6"
PIPE
PRESSURE LOSS CALCULATIONS
(VALVE A-10 @ 32 GPM)
LOSS THRU 1 1/2" WATER METER 2.8 PSI
LOSS THRU 1 1/2" B/F DEVICE 10.0 PSI
LOSS THRU 550' OF 2" MAIN 2.3 PSI
LOSS THRU GATE VALVES 1.0 PSI
LOSS THRU 1" VALVE 3.1 PSI
LOSS THRU LATERAL LINES 2.1 PSI
ELEVATION LOSS -0.9 PSI
MISC. LOSS THRU FITTINGS 0.4 PSI
TOTAL SYSTEM LOSSES 19.4 PSI
PRESSURE REQUIRED AT HEAD 30 PSI
REGULATED STATIC PRESSURE 67 PSI
RESIDUAL PRESSURE 17.6 PSI
9 AS
PROJECT# 05102
CITY OF FONTANA, CALIFORNIA
.,v -PUBLIC WORKS DEPARTMENT
DRAWN BY: LANDSCAPE PLAN SCALE:
JE FOR 1"=30'
DESIGNED BY: TRACTS 16503 DATE:
JE IRWAPON, August 6, 2008
CHECKED BY APPROVED DV. Q , z DWG. NO. SHEET
RHCITY ENGINEER: RICARDO SANDOVAL, R.C.E. 51152 4065 2 OF 6