Loading...
HomeMy WebLinkAbout4044-1GENERAL NOTES 1. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVELOPMENT DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO START OF ANY WORK IN PUBLIC RIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL (909) 350-7610 2. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS, DETAILS, DIMENSIONS, AND PROCEDURES DESCRIBED IN THE STATE OF CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST EDITION. 3. CONTACT TRAFFIC ENGINEERING PROJECT MANAGER AT (909) 350-7610 TWO WORKING DAYS PRIOR TO REMOVAL OF TRAFFIC CONTROL DEVICES OR EQUIPMENT. STOP SIGNS SHALL ONLY BE REMOVED BY CITY PERSONNEL. 4. ALL WORK, MATERIALS AND EQUIPMENT FOR TRAFFIC SIGNING AND STRIPING SHALL CONFORM TO THESE PLANS, THE STANDARD SPECIFICATIONS FOR THE CITY OF FONTANA, AND THE CALIFORNIA MANUAL ON UNIFORM TRAFFFIC CONTROL DEVICES FOR STREETS AND HIGHWAYS DATED, SEPTEMBER 2006. 5. 2 WORKING DAYS NOTICE SHALL GIVEN TO THE CITY TRAFFIC ENGINEER (909) 350-7610 FOR APPROVAL OF CONTROL POINTS OR "CAT TRACKING" PRIOR TO APPLICATION OF PAVEMENT STRIPING. 6. TRAFFIC SIGN SIZE SHALL BE FOR CONVENTIONAL ROADWAYS UNLESS OTHERWISE SHOWN ON THE PLANS. 7. ALL SIGNS SHALL BE MOUNTED ON GALVANIZED STEEL POSTS, UNLESS OTHERWISE SHOWN ON THE PLANS, PER CITY STANDARD DETAIL 4003. 8. STENCILS USED FOR PAVEMENT MARKINGS SHALL MATCH CITY OF FONTANA STANDARD STENCILS. 9, ALL STRIPING AND PAVEMENT MARKINGS SHALL BE ALKYD THERMOPLASTIC UNLESS OTHERWISE NOTED. 10. CROSSWALKS SHALL HAVE 10' BETWEEN THE CENTERLINE OF THE 12" STRIPES UNLESS OTHERWISE SHOWN ON THE PLANS, PER CITY STANDARD DETAIL 1003. 11. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO SHALL PROVIDE RECORD DRAWINGS AND ELECTRONIC CAD FILES, TO THE CITY TRAFFIC ENGINEER. 12. ALL CONFLICTING STRIPING, MARKINGS TO BE REMOVED, SHALL BE BY SANDBLASTING. 13. BLUE DOT MARKERS (BLUE R.R.P.M.) ARE TO BE INSTALLED AT ALL FIRE HYDRANT LOCATIONS PER CITY STANDARD DETAIL 6005. DEVELOPER: CITY OF FONTANA Li 71 SIGNING AND STRIPING PLANuj MILLER AVENUE I _j ± 660'WEST OF MAPLE AVENUE RAYMOND cn COURT Q PROJECTI LOCATION MILLER AVENUE VICINITY MAP NOT TO SCALE SIGNING AND STRIPING NOTES QUANTITIES 21 APPLY EDGE STRIPE PER MUTCD DET. 27B 126 LF @2 APPLY DOUBLE CENTERLINE PER MUTCD DET. 22 250 LF K. HOVNANIAN/FORECAST HOMES 1500 S. HAVEN, SUITE 100 23 APPLY CENTERLINE STRIPE PER MUTCD DET. 2 460 LF ONTARIO, CA 91761 (909) 937-3270 24 APPLY/REAPPLY THERMOPLASTIC "STOP" LEGEND PAVEMENT MARKING. 4 EA 25 RELOCATE EXISTING R1-1 STOP SIGN AS SHOWN 1 EA STRIPE TO ASPEN AVE. (±220') SEE SIGNING & STRIPING PER DWG. NO. 3809 21 1 1 2 3 4 5 LOT "B" TR 16482 PROP. SIDEWALK rT-1 EX. C & G hL _ -lam _ — — D Q 0 DIAL TWO WORKING BEFORE DAYS BEFORE YOU DI L YOU DIG TOLL FREE -800-227-2600 A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT PROP C & G EX. A.0 BERM PER TR. 16482 EX. C & G 2 2 50' 50' 26 26 EX. C & G--\ EX. C & G T, Ili MIL -LER 32 LEX. R/W Q� I 34 EX. R/W 25' OC (TYP.) 1, 18' 18LEGEND & SIGN 60' BY OTHERS. Q (n LLJ LLJ LL II TR 165118 -_.__ 35 PROP. EP1 b PROP. R/W 100' ------ - �_ 28 24 35' -CD r' EX. R3-7 1` �► o oO 7' 24 �JUE�_jZ i x EX. C& w w APPL DET. 38 o w0 I I REV. REVISION DESCRIPTION DATE ENGR. aTY DATE SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO BRING THEM INTO CONFORMANCE WITH CONDITIONS AND 1�. RECoRO DRJ4W1tJ • 3. ps STANDARDS IN EFFECT. 0 �vde Jest "�C C0� 1 3 N No, 65195 Q 6 ID T Exp; 9-30-07 �OF C ALIF� Q Q o W z Q 0 Ld 00 > U U 24 � Ld I � 30 Q 29 R1-1� 24 0 22 CNI 50' 0 .r EX. LEGEND =1� i TO REMAIN M y SCALE IN FEET 40 80 1 "=40' TGADEVELOPMENT & ENGINEERING, INC. PLANNING AND CIVIL ENGINEERING 3536 CONCOURS STREET, SUITE 220 ONTARIO, CA 91764 (909) 581-7212 PHONE (909) 581-7217 FAX 26 APPLY THERMOPLASTIC "STOP AHEAD" LEGEND PAVEMENT 1 EA MARKING. 27 INSTALL ALL WAY SIGN R1-4 ON EXISTING POST 4 LA 28 APPLY THERMOPLASTIC TYPE IV ARROW PAVEMENT MARKING. 1 EA 29 APPLY/REAPPLY THERMOPLASTIC YELLOW CROSSWALK 338 LF 30 APPLY THERMOPLASTIC 12" WHITE LIMIT LINE 1 EA 31 REMOVE EXISTING CONFLICTING STRIPING BY SANDBLASTING 32 INSTALL SCHOOL SPEED LIMIT ASSEMBLY C S4-3, R2-1(25), S4-2 1 EA 33 INSTALL END SCHOOL ZONE SIGN S5-2 1 EA 34 INSTALL STOP AHEAD SIGN, W3-1 1 EA 35 INSTALL TYPE F DELINEATORS AT 25' O.C. (TYP) 5 EA 36 INSTALL YELLOW REFLECTIVE BANDS ON EXISTING POLE 3 EA 120 7 -&j -v7 MANUEL DE JESUS GONZALES, RCE 65195 (EXP. 9-30-07) DATE cu Nc co Lu r 9-30-� 'k * Ex. Q. r 160 Qif -\%., SRA W 1 V41(A CITY OF FONTANA, CALIFORNIA SIGNING AND STRIPING DRAWN BY: JAJ MILLER AVENUE DESIGNED BY: ± JAJ 660' WEST OF MAPLE AVE CHECKED BY: APPROVED BY: �4� MJG% 124107 CITY TRAFFIC ENGIN R R.C.E. 68819 DATE Li z w Q w Q SCALE: AS SHOWN DATE: JUN 2007 DRAWING NO.: 1 4044