Loading...
HomeMy WebLinkAbout4043-1GENERAL NOTES 1. ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA STANDARD PLANS, THE CONTRACT PROVISIONS AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION ("GREEN BOOK"). ALL REFERENCE SPECIFICATIONS AND STANDARDS SHALL BE THE LATEST EDITION UNLESS OTHERWISE NOTED. 2. WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CAN NOT BE RESOLVED BY REFERENCE TO PRECEDENCE PROVISIONS IN THE "GREEN BOOK", THE CONTRACTOR SHALL IMMEDIATELY REPORT SAID CONFLICT TO THE CITY ENGINEER FOR RESOLUTION. 3. ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER. 4. ADVANCE CONSTRUCTION SIGNING INDICATING DURATION OF PROJECT SHALL BE IN PLACE ONE WEEK PRIOR TO IMPLEMENTING DETOURS. 5. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVELOPMENT DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC RIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL (909) 350-7610. 6, THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND PROCEDURES DESCRIBED IN THE STATE OF CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST NON -METRIC EDITION UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER. 7. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS OR OTHER TRAFFIC CONTROL DEVICES AT ALL TIMES. 8. THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK FOR TRENCHES 5 FEET OR GREATER IN DEPTH FROM THE CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY. 9. THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE GUARDED BY SHORING, SLOPING OF THE GROUND OR OTHER APPROVED MEANS PURSUANT TO THE REQUIREMENTS OF THE DIVISION OF INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA. TRENCHES LESS THAN FIVE (5) FEET SHALL ALSO BE GUARDED WHEN THE POTENTIAL EXISTS FOR GROUND MOVEMENT. 10. NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT OF WAY WITHOUT OBTAINING A SEPARATE PERMIT FOR THAT PURPOSE. 11. THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION, HOWEVER, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE, IN THE FIELD, THE TRUE LOCATION AND ELEVATION OF ANY EXISTING UTILITIES, AND TO EXERCISE PROPER PRECAUTION TO AVOID DAMAGE THERETO. THE CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT AT 1-800-227-2600 TWO WORKING DAYS BEFORE EXCAVATION. 12. THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES INCLUDING, BUT NOT LIMITED TO, GAS, TELEPHONE, ELECTRIC, CABLE TELEVISION, LANDSCAPING, LANDSCAPE IRRIGATION, DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND CALTRANS. ALL UTILITY COMPANIES SHALL BE GIVEN TWO WORKING DAYS NOTICE PRIOR TO WORK AROUND THEIR FACILITIES. 13. THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES WITHOUT APPROPRIATE AGENCY AUTHORIZATION. CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE WATER COMPANY FOR VALVE OPERATION AND WATER REQUIREMENTS. 14. STATIONING REFERS TO THE CENTERLINE OF STORM DRAIN EXCEPT WHERE OTHERWISE NOTED. 15. ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE CONTRACTOR TO CONSTRUCT THE WORK TO THE PLAN GRADES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL STAKING DURING CONSTRUCTION. 16. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT TIES OR BENCH MARKS WITHOUT PRIOR NOTIFICATION TO THE CITY ENGINEER. 17. REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING SURVEY MONUMENTS, MONUMENT TIES AND BENCH MARKS, SHALL BE DONE BY A REGISTERED CIVIL ENGINEER OR LICENSED LAND SURVEYOR. SURVEY MONUMENTS THAT WILL BE DESTROYED AS A RESULT OF THIS CONSTRUCTION SHALL BE REPLACED. THE CONTRACTOR SHALL NOTIFY THE ENGINEER ONE WEEK PRIOR TO CONSTRUCTION SO THAT TIES TO MONUMENTS CAN BE ESTABLISHED FOR LATER REPLACEMENT OF THE MONUMENT. 18. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES. A MINIMUM 12 FOOT LANE SHALL BE MAINTAINED AT ALL TIMES IN THE CONSTRUCTION AREA FOR RESIDENTS AND EMERGENCY VEHICLES. 19. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL, INCLUDING ADEQUATE WATERING, AT ALL TIMES. 20, THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR DEBRIS TO BE DEPOSITED ONTO PUBLIC OR PRIVATE PROPERTY ADJACENT TO THE RIGHT OF WAY DURING CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL. 21. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR. 22. A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION. FAILURE TO OBTAIN THE REQUIRED DENSITY SHALL REQUIRE RE -WORKING OF THAT PORTION OF THE WORK UNTIL THE SPECIFIED DENSITY IS OBTAINED. 23. CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING STREET IMPROVEMENTS. UPON INSPECTION OF THE SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY NON-ERODEABLE SWALES ENTERING OR LEAVING IMPROVEMENTS. 24. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH TO MATCH EXISTING CONCRETE. 25. NO OPEN TRENCH SHALL BE ALLOWED AT THE END OF THE DAY WITHOUT PRIOR APPROVAL OF THE CITY ENGINEER. 26 PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL EXPOSE EXISTING FACILITIES, AND VERIFY ELEVATION AND LOCATION OF CONNECTIONS. CITY APPROVAL OF CONNECTIONS TO EXISTING FACILITIES DOES NOT IMPLY CORRECTNESS OF ELEVATIONS OR LOCATIONS SHOWN ON THE PLANS. 27. IF EXISTING UTILITIES OR ANY OTHER FACILITIES CONFLICT WITH THE PROPOSED IMPROVEMENTS, THE CONTRACTOR SHALL NOTIFY THE ENGINEER AND ALL AFFECTED AGENCIES IMMEDIATELY. 28. NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN PLACED, INSPECTED AND APPROVED. 29. ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR TO PAVING OF STREETS. 30. APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT PRIOR TO PLACEMENT. 31. ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED TO FINISHED GRADE BY THE PAVING CONTRACTOR UPON COMPLETION OF PAVING. 32. UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING, STRIPING, BARRICADES, AND OTHER TRAFFIC CONTROL DEVICES TO THE SATISFACTION OF THE CITY TRAFFIC ENGINEER. 33. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO SHALL PROVIDE RECORD DRAWINGS TO THE CITY ENGINEER. 34. MINIMUM D -LOAD FOR ALL RCP IS 1350. A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT REV. I REVISION DESCRIPTION CITY OF FONTANA STORM DRAIN IMPROVEMENT PLANS TRACT N0 16518 o TTM 13338 23 24 25 26 127 CV 651954 3 STORM DRAIN DETAILS 9-30-07IVI� 00 END VERTICAL CURVE F.L. FLOW LINE F.S. FINISH SURFACE G.B. GRADE BREAK HGL HYDRAULIC GRADE LINE LO HIGH POINT INV. INVERT L. E. 32 31 30 29 28 P.C.C. HT. N0. 2�--�j RCP IKInFu PRIVATE ENGINEERS NOTICE TO CONTRACTORS THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITIES OR STRUCTURES SHOWN ON THESE PLANS ARE OBTAINED BY A SEARCH OF AVAILABLE RECORDS, TO THE BEST OF OUR KNOWLEDGE, THERE ARE NO EXISTING UTILITIES EXCEPT THOSE SHOWN ON THESE PLANS. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITY LINES SHOWN ON THESE DRAWINGS. THE CONTRACTOR FURTHER ASSUMES ALL LIABILITY AND RESPONSIBILITY FOR THE UTILITY PIPES, CONDUITS OR STRUCTURES SHOWN OR NOT SHOWN ON THESE DRAWINGS. THE CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR THE JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY: THAT THIS SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS. AND THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY, AND HOLD THE OWNER AND THE ENGINEER HARMLESS FROM ANY AND ALL LIABILITY REAL OR ALLEGED IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER OR THE ENGINEER. CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AND SHALL REPORT ALL DISCREPANCIES TO THE ENGINEER PRIOR TO THE COMMENCEMENT OF WORK DATE ENGR. CITY DATE BASIS OF BEARINGS: THE CENTERLINE OF MILLER AVENUE BEING N89'46'38"E PER M.B. 193/1-2 .0. BENCH MARK: # 255 LOCATED AT THE INTERSECTION OF ALDER AVENUE AND MILLER AVENUE DATE 9/67 ELEV 1358.51 PK NAIL WEST END SW CURB RETURN ELEVATION: 1358.51 C'4 � - I TT Nf � N N O O 0243-131-48 L CITY OF FONTANA UTILITY NOTIFICATION LIST CITY OF FONTANA PACIFIC BELL CO. ATTN: BRIAN WREN ATTN: VIRGINIA BECKER 8353 SIERRA AVENUE 3939 E.CORONADO STREET FONTANA, CA 92335 ANAHEIM, CA 92807 (909) 350-6632 (714) 666-5467 THE GAS COMPANY COMCAST (CABLE TV) ATTN. GREG GASPAR ATTN: JACK HAYES 16231 VALLEY BLVD. 1205 DUPONT AVENUE FONTANA, CA. 92335 ONTARIO, CA. 91761 909) 428-8411 (909) 390-4736 MERGENCIES: (800) 427-2200 GENERAL TELEPHONE COMPANY SO. CALIFORNIA EDISON COMPANY ATTN: STEVE HOCK 7951 REDWOOD AVENUE 1400 E. PHILLIPS BLVD. FONTANA, CA. 92335 ONTARIO, CA. 91766 (909) (909) 820-5598 UNDERGROUND (800) 422-4133 (909) 875-5100 - TRANSMISSIONS (213) 637-1233 PIPELINES FONTANA WATER COMPANY (909) 357-6233 DISTRIBUTION ATTN: MICHAEL J. McGRAW (800) 422-4133 8440 NUEVO AVENUE FONTANA, CA 92335 CRAWFORD CANYON MUTUAL WATER CO. (909) 822-2201 ATTN: BILL VANDERKIEFT, JR. FAX: (909) 823-504 QPpt:ESSIpNq< (619) 868-6040 Qk,� e 3esus UNDERGROUND SERVICE ALERT co (800) 227-2600 m No. 65195 y cc 9-30- -0 1 - OF OF CAL��O/ SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO BRING THEM INTO CONFORMANCE WITH CONDITIONS AND STANDARDS IN EFFECT. �_ JestoY SHEET No. DESCRIPTION 1 TITLE SHEET (cNo. 651954 3 STORM DRAIN DETAILS 9-30-07IVI� SHEET INDEX SHEET No. DESCRIPTION 1 TITLE SHEET 2 LINE "Al " "A" & "B" LATERALS "B" -l" & "B-2" 3 STORM DRAIN DETAILS 4 STORM DRAIN DETAILS GRANULAR BEDDING FROM / SELECTED TRENCH SIDE MATERIAL (1" MAX. SIZE). SOILS ENGINEER: ALBUS-KEEFE & ASSOCIATES, INC. 1011 NORTH ARMANDO STREET ANAHEIM, CA 92806-2606 (714) 630-1626 DEVELOPER: K. HOVNANIAN/FORECAST HOMES 4240 E. JURUPA STREET, SUITE 402 ONTARIO, CA 91764 (909) 937-3270 wEr.»N.l A. C. ASPHALTIC CONCRETE B.C. BEGIN CURVE B.V.C. BEG. VERTICAL CURVE B.W. BACK SIDEWALK C.B. CATCH BASIN C.L. CENTERLINE E.C. END CURVE E. P. EDGE PAVEMENT E.G. EDGE GRADE E.V.C. END VERTICAL CURVE F.L. FLOW LINE F.S. FINISH SURFACE G.B. GRADE BREAK HGL HYDRAULIC GRADE LINE H.P. HIGH POINT INV. INVERT L. E. LANDSCAPE EASEMENT MH MANHOLE O.C. ON CENTER P.C.C. PORTLAND CEMENT CONCRETE (R) RIDGE LINE RCP REINFORCED CONCRETE PIPE R/W RIGHT OF WAY SD STORM DRAIN TAN. TANGENT T.C. TOP OF CURB WS WATER SURFACE CSPA CORRUGATED STEEL PIPE ARCH „tteceRD DIM1114119G," TGA TOP OF STRUCTURAL PVM'T. SUBGRADE 3" MAX. SIZE NATIVE SOIL COMPACTED 95% 1:1 SLOPE OR FLATTER OR ADEQUATE SHORING 90% COMPACTED NATIVE BACKFILL 6" MAX. SIZE VICINITY MAP NOT TO SCALE NOTES: 1. TRENCH WIDTH SHALL BE CONTROLLED TO TOP OF PIPE ZONE. 2. TRENCH DEPTHS OF GREATER THAN 5' SHALL HAVE ADEQUATE SHORING. __ I 1 1 3. CLASS II AGG.BASE ALL TRENCHES 6" MIN. I I I = LESS THAN 100' IN LENGTH. 8" MAX. III = III NOTE: III w COMPACTION SHALL BE 90% IN ALL m ZONES UNLESS OTHERWISE SPECIFIED. 2 3 TRENCH STABILITY SHALL CONFORM 0 TO CAL -OSHA REQUIREMENTS. i m STORM DRAIN PIPE 7Z0.6'D' GRANULAR BEDDING FROM SELECTED TRENCH SIDE MATERIAL FOR PIPE 10' OR GREATER IN DEPTH USE 1/2 CRUSHED STONE BEDDING. RCP TRENCH DETAIL NOT TO SCALE as CONSTRUCTION NOTES III O1 INSTALL 18" RCP, D -LOAD PER PROFILE III LF Z INSTALL 24" RCP, D -LOAD PER PROFILE s \ LF O3 INSTALL 30" RCP, D -LOAD PER PROFILE ti LF OCONSTRUCT PARKWAY DRAIN PER APWA STD. 151-1 (S=42"), 116 LF III = IIIIII III VICINITY MAP NOT TO SCALE NOTES: 1. TRENCH WIDTH SHALL BE CONTROLLED TO TOP OF PIPE ZONE. 2. TRENCH DEPTHS OF GREATER THAN 5' SHALL HAVE ADEQUATE SHORING. __ I 1 1 3. CLASS II AGG.BASE ALL TRENCHES 6" MIN. I I I = LESS THAN 100' IN LENGTH. 8" MAX. III = III NOTE: III w COMPACTION SHALL BE 90% IN ALL m ZONES UNLESS OTHERWISE SPECIFIED. 2 3 TRENCH STABILITY SHALL CONFORM 0 TO CAL -OSHA REQUIREMENTS. i m STORM DRAIN PIPE 7Z0.6'D' GRANULAR BEDDING FROM SELECTED TRENCH SIDE MATERIAL FOR PIPE 10' OR GREATER IN DEPTH USE 1/2 CRUSHED STONE BEDDING. RCP TRENCH DETAIL NOT TO SCALE as CONSTRUCTION NOTES QUANTITIES O1 INSTALL 18" RCP, D -LOAD PER PROFILE 296 LF O2 INSTALL 24" RCP, D -LOAD PER PROFILE 266 LF O3 INSTALL 30" RCP, D -LOAD PER PROFILE 310 LF OCONSTRUCT PARKWAY DRAIN PER APWA STD. 151-1 (S=42"), 116 LF SEE DETAIL ON SHEET 3 OCONSTRUCT MANHOLE PER A.P.W.A. STD. PLAN 322-1, 1 EA SEE DETAIL ON SHEET 3 OCONSTRUCT HEADWALL PER CALTRANS STD. D89, 1 EA SEE DETAIL ON SHEET 4 OINSTALL CONCRETE FLARED END SECTION PER CALTRANS 1 EA STD. D9413, PER DETAIL ON SHEET 4 OCONSTRUCT GROUTED RIP RAP PER PLAN AND 90 SF PER DETAIL ON SHEET 3 9O CONSTRUCT 6' DIAMETER BY 25' DEEP MAXWELL CONC. CHAMBER 3 EA PER DETAIL ON SHEET 4 10 CONSTRUCT 15' WIDE 5" THICK CONCRETE MAINT. ACCESS ROAD 1224 SF SEE DETAIL ON SHEET 3 11 CONSTRUCT MODIFIED PARKWAY DRAIN PER APWA STD. 150-2 1 EA PER DETAIL ON SHEET 3 (REPLACE 4" PIPES WITH 4"X14" RECTANGULAR CAST IRON PIPE, ALHAMBRA A-470 OR APPROVED EQUAL) 12 CONSTRUCT 20' WIDE, 3.5" THICK CONCRETE SPILLWAY 450 SF PER DETAIL ON SHEET 3 13 CONSTRUCT CONCRETE BLANKET PER APWA STD. 225-1, 2 EA SEE DETAIL ON SHEET 4 14 TRENCHING PER CITY OF FONTANA STD. DWG. NO. 1031 - 15 INSTALL TRASH RACK PER 'MODIFIED APWA STD. 361-0 OR 1 EA APPROVED EQUAL. SEE DETAIL ON SHEET 4 CITY OF FONTANA CALIFORNIA DEVELOPMENT & ENGINEERING, INC. ' PLANNING AND CIVIL ENGINEERING STORM DRAIN IMPROVEMENT PLANS DRAWN BY: SCALE: 3536 CONCOURS STREET, SUITE 220 ONTARIO, CA 91764 JAJ TR 16518 AS SHOWN (909) 581-7212 PHONE (909) 581-7217 FAX DESIGNED BY: JAJ T I TIS SHEET DATE. APR 2006 CHECKED BY: B DRAWING NO.: 1 MANUEL DE JESUS GONZAL RCE 5195 (EXP. 9-30-07) DATE y- MJG7V;fTrE N ZRC4.E. 51152 DATE 4043 4