Loading...
HomeMy WebLinkAbout3953-15Wo V) Z 3z coQ U r- J wm cn x o6 6—#8 BARS VERTICALLY W/6—#3 TIES ® 3" O.C: AT TOP THEN ®6" O.C. HORIZONTALLY. (4) %4" X 30" ANCHOR �\ BOLTS ELECTRICAL - CONDUIT 4"X11 ga. BE17 FIXTURE H2 DISTRIBUTION FLAT LENS WITH HOUSE—SIDE SHIELD HAl2S—BE17 ARM NON—TAPERED ROUND STEEL POLE KRS16-4120 HANDHOLE BUSH END ELECTRICAL CONDUIT PER SHEETS 12, 13 & 14 (TYP.) 3" CLEAR 10% SLOPED CONCRETE BASE (TYP.) SANDBLAST CONCRETE SURFACE TO ELIMINATE FINISH FORM LINES (TYP.) SURFACE OR CONCRETE PAD (SHEETS 12, 13 & 14) WEAKENED PLANE JOINT PER CITY OF FONTANA STD. PLAN NO. 1015 4—#8 WIRES & 1—#8 GROUND 560—C-3250 FINISH SURFACE CONCRETE FOUNDATION BIKE TRAIL POLE -MOUNTED LIGHTING N.T.S SIGNS LEGEND APPLIED ON SHEETS 12, 13 & 14. R9-5 BIKE PATH NO MOTOR VEHICLES OR MOTORIZED VEHICLES R44A R1 PROP. ELEC. CONDUIT U) J w -d L O V) r Q ry F- w N 50 v) a NO. 3 1/2 PULL BOX I I i 1 1 Y C PVC SCH.80 — —� 'WITH 3—#8 WIRES 4, 6„ ELECTRICAL CONDUIT PER SHEETS 12, 13 & 14 (TYP.) 13' CONCRETE FOOTING (*) / ELECTRICAL CONDUIT PER SHEETS 12, 13 & 14 (TYP.) 4' THICK CONCRETE \ PAD MATCH TRAIL FINISH -POLE BAST COVER (*) 4' NOTE: (*) NEW LIGHTS SHALL BE LOCATED AT THE CENTER OF CONCRETE PAD HORIZONTALLY IN THE ABSENCE OF ADJACENT PULL BOX AS SHOWN PER SHEETS 12, 13 & 14. CONCRETE LIGHTING PAD DETAIL PLAN VIEW N.T.S� r---- NEW ELECTRICAL SERVICE ENCLOSURE PER SHEET 12: 50A, 240V, 2P—MAIN BREAKER 20A, 240V, 2P—CIRCUIT "A" 20A, 240V, 2P—CIRCUIT "B" 20A, 120V, 1P—IRRIGATION CONTROLLER "A7' 2—LIGHTING CONTACTORS 1—INTERMATIC TIME SWITCH, ET70215C BASELINE AVENUE 240V POWER SOURCE EXIST. PACBELL—LID PULLBOX SERVICE WIRES BY SCE 2—#8 WIRES & 1—#8 GROUND (TYPICAL) CIRCUIT "A" 2—#8 WIRES--/ & 1—#8 GROUND Ff (TYPICAL) CIRCUIT "B" 2—#8 WIRES & 1.—#8 GROUND (TYPICAL) CIRCUIT "B" WIDIAIr_ nlAr_DARA CnD CCMACAIT "r A" (REFER TO SHEET 16 FOR PANEL SCHEDULES, LIGHTING—CONTROL AND SINGLE—LINE DIAGRAMS). EDGE OF BIKE TRAIL PAVEMENT WEAKENED PLANE JOINT PER CITY OF FONTANA STD. PLAN NO. 1015 2—#8 WIRES & 1—#8 GROUND (TYPICAL) CIRCUIT "D" N V) w V) �I po N w _ V) SERVICE WIRES BY SCE f1rT• 11 I1�1"1 ULINIL L/D i BA ING DETAI C st P N.T. 1 9' 3' 9' r`CAITCDI IAIC CTDIDIAIr`_ nCTAII ERA BELL 17 TRAIL LIGHTS LIGHTING DESIGNATION 2—#8 WIRES & 1—#8 GROUND (TYPICAL) CIRCUIT "C" 4—#8 WIRES & 1—#8 GROUND EDGE OF BIKE TRAIL PAVEMENT r-Lt:U I MIUML VCIl1Zr`% AL IVU 1 CO. 1. ALL WORK IS TO BE DONE IN ACCORDANCE WITH 2004 CALIFORNIA ELECTRICAL CODE (CEC). 2. SERVICE EQUIPMENT INSTALLATION SHALL BE IN ACCORDANCE WITH ARTICLE 110-26(F), 230-66, 230-70(B) IN THE CEC 2004 3. ALL LIGHT POLES SHALL BE GROUNDED AND BONDED PER ARTICLE 250 OF 2004 CEC. 4. UTILITIES AND LIGHTING EQUIPMENTS ARE DRAWN DIAGRAMMATICALLY. SCALED DIMENSIONS ARE APPROXIMATE ONLY. BEFORE PROCEEDING WORK CAREFULLY CHECK AND VERIFY DIMENSIONS, IMMEDIATELY NOTIFY ENGINEER OF DISCREPANCIES BETWEEN DRAWINGS OR SPECIFI— CATIONS AND ACTUAL CONDITIONS. ALTHOUGH SIZES AND LOCATIONS EQUIPMENT ARE DRAWN TO SCALE WHEREVER POSSIBLE, IT IS NOT WITHIN SCOPE OF THE DRAWINGS TO SHOW NECESSARY OFFSETS, OBSTRUCTIONS, OR SITE CONDITIONS. THE CONTRACTOR WILL BE RESPONSIBLE TO INSTALL WORK IN SUCH A MANNER THAT IT WILL CONFORM TO SITE CONDITIONS, COMPLETE AND IN GOOD WORKING ORDER. 5. ALL ELECTRICAL CONDUCTORS ARE TO BE COPPER. INSULATION FOR #12 TO #1 WIRES SHALL BE THWN. GROUNDING CONDUCTORS SHALL BE THWN F Al I C nNnl IIT gWFFP� gHAI I RF PVC: qC�H Rn NEW ELECTRICAL SERVICE ENCLOSURE PER SHEET 14: 50A, 240V, 2P—MAIN BREAKER 20A, 240V, 2P—CIRCUIT "C" 20A, 240V, 2P—CIRCUIT "D" 20A, 120V, 1P—IRRIGATION CONTROLLER "B" 2—LIGHTING CONTACTORS 1—INTERMATIC TIME SWITCH, ET70215C RECORD DR/4 N1067