Loading...
HomeMy WebLinkAbout3953-123 O co I U 0 u� a c a a U i 0 0 } 3 0 O MH SOUTH wVHERITAGE CIRCLE ._j U � w 0 Q H STA 55+41.83 W H O''os U) I 13300 ► OM OS CB ASPP �- CITY OF FONTANA R/W ,r -EXIST. STRIPING PROPOSED CROSSWALK AS PART OF SEGMENT 5B IMPROVEMENT REFER TO M __� _ BASEL SHEET C-806 � �� � IN��� AV . A BASELINE AVE. + PACIFIC ELECTRIC R/W f 155' GENERAL NOTES (APPLICABLE TO SHEETS 12 THROUGH 16) CONSTRUCTION MOTES (CONTINUES) 1. ALL WORK, MATERIALS AND EQUIPMENT FOR TRAFFIC SIGNING AND STRIPING SHALL CONFORM TO THESE PLANS, THE MUTCD 2003, CALIFORNIA SUPPLEMENT 27 INSTALL 1-1/27 PVC SCH. 40 WITH 5-#8 WIRES, TO MUTCD 2003, CITY OF FONTANA'S STANDARD SPECIFICATIONS, AND 2-#8 FOR EACH CIRCUIT, PLUS 1-#8 GROUND CALTRANS STANDARD SPECIFICATIONS 1999. PER WIRING DIAGRAM ON SHEET 15 2 TRAFFIC SIGN SHALL BE STANDARD SIZE UNLESS OTHERWISE SHOWN ON THE 7B INSTALL 1-1/2" PVC SCH. 40 WITH 3-#8 WIRES, PLANS. PER WIRING DIAGRAM ON SHEET 15 3, ALL SIGNS SHALL BE MOUNTED ON GALVANIZED STEEL POST, UNLESS 29 FURNISH AND INSTALL ESB36-U2-MPEA1610K-OB1-VRA OTHERWISE SHOWN, PER CITY OF FONTANA'S STANDARD DETAIL NO. 139. ELECTRICAL/IRRIGATION SERVICE ENCLOSURE (METERED) 4. CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT AT WITH 50A MAIN BREAKER, 2 -2P -20A LIGHTING CIRCUITS, (800)227-2600 AT LEAST 48 HOURS PRIOR TO ANY EXCAVATION. 1-1 P -20A IRRIGATION BREAKER AND A TIME SWITCH THE CONTRACTOR ACCEPTS ALL RESPONSIBILITY FOR ANY AND ALL PER SPECIFICATIONS AND DETAIL "E" ON SHEET 16. DAMAGES TO EXISTING UTILITIES. INSTALL 3-#8 SERVICE WIRES TO IRRIGATION CONTROLLER. CONSTRUCTION NOTES 21 APPLY 47 -WIDE YELLOW CENTERLINE STRIPING PER DETAIL "D" ON SHEET 15. �2 INSTALL SIGN(S) AS SHOWN. 24 INSTALL 175W MH -240V ERA BELL BE17-H2-HS FIXTURE WITH FLAT LENS, HAl2S ARM, KRS16-4120/SA/LG-P/BC4/ DR-GFI NON-TAPERED ROUND STEEL POLE AND FOUNDATION BY KIM LIGHTING OR APPROVED EQUAL. REFER TO DETAIL "A' ON SHEET 15 FOR DETAILS. �5 INSTALL NO. 3-1/2(T) PULL BOX PER CALTRANS STD. PLAN ES -8. (UNLESS NOTED OTHERWISE) 26 CONSTRUCT 47 -THICK CONCRETE PAD PER DETAIL "B" ON SHEET 15 ON COMPACTED NATIVE. oe 441 ,p `j r ✓ ` t EXIST. x --PAC BELL -CON* 10, 0,LID 7"X3 LLBOX . _._.._._.....___e._.___ _..,. - ..._._._....______..,.a_.._...._._.._.._._..._.__ -- #5` PULLBOX 5 ` ' r` TORO SENTINEL EXISTING MNG J ' ,�` (T) r,f- -� ,-'` p� j IRRIGATION ,,,,,,-rr , RAILROAD RIGHT-OF-WAY 20' 10' 0 20' 40' SCALE IN FEET FOR BENCHMARK AND BASIS OF BEARINGS, SEE SHEET 1 I A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT PACIFIC ELECTRIC APN 1110-781-07 i 0 30 INSTALL STREET LIGHT 22,000 LUMEN PER CITY O STD. PLAN NO. 1016. MATCH TYPE AND EQUIPMENT TO EXISTING, ADJACENT STREET LIGHTS. 31 INSTALL NO. 3-1/2 PULL BOX PER CALTRANS STD. O PLAN ES -8 INTO AN EXISTING CONDUIT RUN. co MAKE AN OPERABLE SYSTEM. 32 U_ WIRES FROM NEW STREET LIGHT TO NEW J PULL BOX. SPLICE WIRES FOR CONNECTION 33 CONSTRUCT 3" PVC SCH. 40 CONDUIT FROM DESIGNATED POWER CONNECTION TO SERVICE 3: ENCLOSURE. SCE IS TO FURNISH AND INSTALL WIRING. W INSTALL CONDUIT TO EXISTING PULLBOX Z O J J (MR. DAVID MORASS (909)357-6585). U H f 155' GENERAL NOTES (APPLICABLE TO SHEETS 12 THROUGH 16) CONSTRUCTION MOTES (CONTINUES) 1. ALL WORK, MATERIALS AND EQUIPMENT FOR TRAFFIC SIGNING AND STRIPING SHALL CONFORM TO THESE PLANS, THE MUTCD 2003, CALIFORNIA SUPPLEMENT 27 INSTALL 1-1/27 PVC SCH. 40 WITH 5-#8 WIRES, TO MUTCD 2003, CITY OF FONTANA'S STANDARD SPECIFICATIONS, AND 2-#8 FOR EACH CIRCUIT, PLUS 1-#8 GROUND CALTRANS STANDARD SPECIFICATIONS 1999. PER WIRING DIAGRAM ON SHEET 15 2 TRAFFIC SIGN SHALL BE STANDARD SIZE UNLESS OTHERWISE SHOWN ON THE 7B INSTALL 1-1/2" PVC SCH. 40 WITH 3-#8 WIRES, PLANS. PER WIRING DIAGRAM ON SHEET 15 3, ALL SIGNS SHALL BE MOUNTED ON GALVANIZED STEEL POST, UNLESS 29 FURNISH AND INSTALL ESB36-U2-MPEA1610K-OB1-VRA OTHERWISE SHOWN, PER CITY OF FONTANA'S STANDARD DETAIL NO. 139. ELECTRICAL/IRRIGATION SERVICE ENCLOSURE (METERED) 4. CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT AT WITH 50A MAIN BREAKER, 2 -2P -20A LIGHTING CIRCUITS, (800)227-2600 AT LEAST 48 HOURS PRIOR TO ANY EXCAVATION. 1-1 P -20A IRRIGATION BREAKER AND A TIME SWITCH THE CONTRACTOR ACCEPTS ALL RESPONSIBILITY FOR ANY AND ALL PER SPECIFICATIONS AND DETAIL "E" ON SHEET 16. DAMAGES TO EXISTING UTILITIES. INSTALL 3-#8 SERVICE WIRES TO IRRIGATION CONTROLLER. CONSTRUCTION NOTES 21 APPLY 47 -WIDE YELLOW CENTERLINE STRIPING PER DETAIL "D" ON SHEET 15. �2 INSTALL SIGN(S) AS SHOWN. 24 INSTALL 175W MH -240V ERA BELL BE17-H2-HS FIXTURE WITH FLAT LENS, HAl2S ARM, KRS16-4120/SA/LG-P/BC4/ DR-GFI NON-TAPERED ROUND STEEL POLE AND FOUNDATION BY KIM LIGHTING OR APPROVED EQUAL. REFER TO DETAIL "A' ON SHEET 15 FOR DETAILS. �5 INSTALL NO. 3-1/2(T) PULL BOX PER CALTRANS STD. PLAN ES -8. (UNLESS NOTED OTHERWISE) 26 CONSTRUCT 47 -THICK CONCRETE PAD PER DETAIL "B" ON SHEET 15 ON COMPACTED NATIVE. oe 441 ,p `j r ✓ ` t EXIST. x --PAC BELL -CON* 10, 0,LID 7"X3 LLBOX . _._.._._.....___e._.___ _..,. - ..._._._....______..,.a_.._...._._.._.._._..._.__ -- #5` PULLBOX 5 ` ' r` TORO SENTINEL EXISTING MNG J ' ,�` (T) r,f- -� ,-'` p� j IRRIGATION ,,,,,,-rr , RAILROAD RIGHT-OF-WAY 20' 10' 0 20' 40' SCALE IN FEET FOR BENCHMARK AND BASIS OF BEARINGS, SEE SHEET 1 I A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT PACIFIC ELECTRIC APN 1110-781-07 i REV. REVISION DESCRIPTION DATE ENGR. CITY DATE en6ine+�Arn� F30 4'LSHOULDRECORD DiZAWlWb) �o�L3 •fir• oQNq0/ CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO �� ��` y F2 1501 QUAIL ST., NEWPORT BEACH, CA. 92660 c j 0 PHONE: (949) 476-3300 FAX: (949) 721-7142 YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND CARRIED FORTH IN A DILIGENT No. 64286 m Pre ed Under The Supervision Of MANNER, THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO BRING THEM Ex 6/30/200 P. 7 * INTO CONFORMANCE WITH CONDITIONS AND STANDARDS IN EFFECT. J x 0 V 1 ��P • TF OF CA��FDate Q CO L LU Z co J W ►V 2ECO2D bRA r IN& 4c Q CITY OF FONTANA, CALIFORNIA PACIFIC ELECTRIC INLAND EMPIRE TRAIL IMPROVEMENT DRAWN BY SCALE: RA SIGNING, STRIPING AND 1" = 20' DESIGNED BY: LIGHTING PLAN DATE: AN 1 11 12/12/05 CHECKED BY: APPR D BY:Z DRAWING No. 1 Z AN CITY ENGINEER R.C.E. 51152 DATE: 27 CONSTRUCT FOUNDATION COMPLETE. 30 INSTALL STREET LIGHT 22,000 LUMEN PER CITY STD. PLAN NO. 1016. MATCH TYPE AND EQUIPMENT TO EXISTING, ADJACENT STREET LIGHTS. 31 INSTALL NO. 3-1/2 PULL BOX PER CALTRANS STD. PLAN ES -8 INTO AN EXISTING CONDUIT RUN. SPLICE NEW TO EXISTING CONDUCTORS TO MAKE AN OPERABLE SYSTEM. 32 INSTALL 1-1/2" PVC SCH. 40 WITH 3#8 WIRES FROM NEW STREET LIGHT TO NEW PULL BOX. SPLICE WIRES FOR CONNECTION 33 CONSTRUCT 3" PVC SCH. 40 CONDUIT FROM DESIGNATED POWER CONNECTION TO SERVICE ENCLOSURE. SCE IS TO FURNISH AND INSTALL WIRING. 34 INSTALL CONDUIT TO EXISTING PULLBOX FOR POWER SOURCE CONNECTION. COORDINATE WITH SCE REPRESENTATIVE, (MR. DAVID MORASS (909)357-6585). REV. REVISION DESCRIPTION DATE ENGR. CITY DATE en6ine+�Arn� F30 4'LSHOULDRECORD DiZAWlWb) �o�L3 •fir• oQNq0/ CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO �� ��` y F2 1501 QUAIL ST., NEWPORT BEACH, CA. 92660 c j 0 PHONE: (949) 476-3300 FAX: (949) 721-7142 YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND CARRIED FORTH IN A DILIGENT No. 64286 m Pre ed Under The Supervision Of MANNER, THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO BRING THEM Ex 6/30/200 P. 7 * INTO CONFORMANCE WITH CONDITIONS AND STANDARDS IN EFFECT. J x 0 V 1 ��P • TF OF CA��FDate Q CO L LU Z co J W ►V 2ECO2D bRA r IN& 4c Q CITY OF FONTANA, CALIFORNIA PACIFIC ELECTRIC INLAND EMPIRE TRAIL IMPROVEMENT DRAWN BY SCALE: RA SIGNING, STRIPING AND 1" = 20' DESIGNED BY: LIGHTING PLAN DATE: AN 1 11 12/12/05 CHECKED BY: APPR D BY:Z DRAWING No. 1 Z AN CITY ENGINEER R.C.E. 51152 DATE: 27