HomeMy WebLinkAbout3946-1GENERAL NOTES
1. ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA STANDARD PLANS,
THE CONTRACT PROVISIONS AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION
("GREEN BOOK'). ALL REFERENCE SPECIFICATIONS AND STANDARDS SHALL BE THE LATEST EDITION
UNLESS OTHERWISE NOTED.
2. WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CAN NOT BE
RESOLVED BY REFERENCE TO PRECEDENCE PROVISIONS IN THE "GREEN BOOK", THE CONTRACTOR
SHALL IMMEDIATELY REPORT SAID CONFLICT TO THE CITY ENGINEER FOR RESOLUTION.
J. ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER.
4. ADVANCE CONSTRUCTION SIGNING INDICATING DURATION OF PROJECT SHALL BE IN PLACE ONE WEEK
PRIOR TO IMPLEMENTING DETOURS.
5. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVELOPMENT
DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK, INSPECTION COORDINATION
SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC
RIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL (909) 350-7610.
6. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND PROCEDURES
DESCRIBED IN THE STATE OF CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST NON -METRIC EDITION
UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER.
7. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS OR
OTHER TRAFFIC CONTROL DEVICES AT ALL TIMES.
8. THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK FOR TRENCHES
5 FEET OR GREATER IN DEPTH FROM THE CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY.
9. THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE
GUARDED BY SHORING, SLOPING OF THE GROUND OR OTHER APPROVED MEANS PURSUANT TO THE
REQUIREMENTS OF THE DIVISION OF INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA. TRENCHES LESS
THAN FIVE (5) FEET SHALL ALSO BE GUARDED WHEN THE POTENTIAL EXISTS FOR GROUND MOVEMENT
10. NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT OF WAY WITHOUT OBTAINING A
SEPARATE PERMIT FOR THAT PURPOSE.
11. THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION, HOWEVER,
IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE, IN THE FIELD, THE TRUE
LOCATION AND ELEVATION OF ANY EXISTING UTILITIES, AND TO EXERCISE PROPER PRECAUTION TO
AVOID DAMAGE THERETO. THE CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT AT
1-800-227-2600 TWO WORKING DAYS BEFORE EXCAVATION.
12. THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES INCLUDING, BUT
NOT LIMITED TO GAS, TELEPHONE, ELECTRIC, CABLE TELEVISION, LANDSCAPING, LANDSCAPE IRRIGATION,
DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND CALTRANS, ALL
UTILITY COMPANIES SHALL BE GIVEN TWO WORKING DAYS NOTICE PRIOR TO WORK AROUND THEIR
FACILITIES.
13. THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES WITHOUT
APPROPRIATE AGENCY AUTHORIZATION. CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE WATER
COMPANY" FOR VALVE OPERATION AND WATER REQUIREMENTS.
14. STATIONING REFERS TO THE CENTERLINE OF STORM DRAIN EXCEPT WHERE OTHERWISE NOTED.
15. ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE
CONTRACTOR TO CONSTRUCT THE WORK TO THE PLAN GRADES. THE CONTRACTOR SHALL BE
RESPONSIBLE FOR THE PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL STAKING DURING
CONSTRUCTION.
16. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT TIES OR BENCH
MARKS WITHOUT PRIOR NOTIFICATION TO THE CITY ENGINEER.
17. REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING SURVEY MONUMENTS,
MONUMENT TIES AND BENCH MARKS, SHALL BE DONE BY A REGISTERED CIVIL ENGINEER OR LICENSED
LAND SURVEYOR. SURVEY MONUMENTS THAT WILL BE DESTROYED AS A RESULT OF THIS CONSTRUCTION
SHALL BE REPLACED. THE CONTRACTOR SHALL NOTIFY THE ENGINEER ONE WEEK PRIOR TO
CONSTRUCTION SO THAT TIES TO MONUMENTS CAN BE ESTABLISHED FOR LATER REPLACEMENT OF THE
MONUMENT.
18. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES. A
MINIMUM 12 FOOT LANE SHALL BE MAINTAINED AT ALL TIMES IN THE CONSTRUCTION AREA FOR
RESIDENTS AND EMERGENCY VEHICLES.
19. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL, INCLUDING
ADEQUATE WATERING, AT ALL TIMES.
20. THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR DEBRIS TO BE
DEPOSITED ONTO PUBLIC OR PRIVATE PROPERTY ADJACENT TO THE RIGHT OF WAY DURING
CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL.
21. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR.
22. A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION, FAILURE TO OBTAIN THE
REQUIRED DENSITY SHALL REQUIRE RE -WORKING OF THAT PORTION OF THE WORK UNTIL THE
SPECIFIED DENSITY IS OBTAINED.
23. CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING STREET
IMPROVEMENTS. UPON INSPECTION OF THE SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY
NON-ERODEABLE SWALES ENTERING OR LEAVING IMPROVEMENTS.
24. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH TO MATCH
EXISTING CONCRETE.
25. NO OPEN TRENCH SHALL BE ALLOWED AT THE END OF THE DAY WITHOUT PRIOR APPROVAL OF THE
CITY ENGINEER.
26. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL EXPOSE EXISTING FACILITIES, AND VERIFY ELEVATION
AND LOCATION OF CONNECTIONS. CITY APPROVAL OF CONNECTIONS TO EXISTING FACILITIES DOES NOT
IMPLY CORRECTNESS OF ELEVATIONS OR LOCATIONS SHOWN ON THE PLANS.
21-1. IF EXISTING UTILITIES OR ANY OTHER FACILITIES CONFLICT WITH THE PROPOSED IMPROVEMENTS, THE
CONTRACTOR SHALL NOTIFY THE ENGINEER AND ALL AFFECTED AGENCIES IMMEDIATELY.
28 NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN PLACED,
INSPECTED AND APPROVED.
29. ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR TO PAVING OF
STREETS.
30. APPROVED SOILS STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT PRIOR TO PLACEMENT
31. ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED TO FINISHED GRADE
BY THE PAVING CONTRACTOR UPON COMPLETION OF PAVING.
,32, UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING, STRIPING,
BARRICADES, AND OTHER TRAFFIC CONTROL DEVICES TO THE SATISFACTION OF THE CITY
TRAFFIC ENGINEER.
33. AS-BULIT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF
RECORD, WHO SHALL PROVIDE RECORD DRAWINGS TO THE CITY ENGINEER.
34. THE CONCRETE COATING ON THE INSIDE OF ALL REINFORCED CONCRETE PIPES MUST BE
INCREASED TO PROVIDE A MINIMUM OF 1-1/2" OVER THE REINFORCING WHEN THE
DESIGN VELOCITIES EXCEED 20 FEET PER SECOND. THE CONCRETE DESIGN STRENGTH IN
THESE REACHES SHALL BE fc=5,000 psi FOR VELOCITIES EXCEEDING 20 FEET PER
SECOND AND fc=6,000 psi FOR VELOCITIES EXCEEDING 30 FEET PER SECOND.
DIAL
35. MINIMUM D -LOAD FOR ALL R.C.P. IS 1350. BEFOF
YOU C
36. ADVANCE CONSTRUCTION SIGNING INDICATING DURATION OF PROJECT SHALL BE IN TOLL FRE
PLACE ONE WEEK PROIR TO IMPLEMENTING DETOURS. A DI IPI Ir cr
CITY OF FONTANA
STORM DRAIN IMPROVEMENT PLANS
LINE "A" FROM 10+00.00 TO 14104.10 Z!
4
TRACT 17438
PRIVATE ENGINEER'S NOTICE TO CON TRA C TORS
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITIES OR STRUCTURES SHOWN
ON THESE PLANS ARE OBTAINED BY A SEARCH OF AVAILABLE RECORDS; TO THE BEST
OF OUR KNOWLEDGE, THERE ARE NO EXISTING UTILITIES EXCEPT THOSE SHOWN ON
THESE PLANS. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES
TO PROTECT THE UTILITY LINES SHOWN ON THESE DRAWINGS. THE CONTRACTOR FURTHER
ASSUMES ALL LIABILITY AND RESPON- SIBILITY FOR THE UTILITY PIPES, CONDUITS OR
STRUCTURES SHOWN OR NOT SHOWN ON THESE DRAWINGS.
THE CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY
FOR THE JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS
PROJECT; INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS SHALL APPLY
CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS; AND THAT THE
CONTRACTOR SHALL DEFEND, INDEMNIFY, AND HOLD THE OWNER AND THE ENGINEER
HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE
PERFORMANCE- OF WORK ON THIS PROJECT, EXCEPTING FOR LIABILITY ARISING FROM THE
SOLE NEGLIGENCE OF THE OWNER OR THE ENGINEER.
CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AND SHALL REPORT ALL
DISCREPANCIES TO THE ENGINEER PRIOR TO THE COMMENCEMENT OF ANY WORK. IT IS
THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY THE ENGINEER OF ANY
DISCREPANCIES. BEGINNING OF WORK MEANS ACCEPTANCE OF CONDITIONS.
CONTRACTOR SHALL COMPLY WITH ALL N.P.D.E.S. REQUIREMENTS.
CONTRACTOR SHALL ADJUST TO FINISH GRADE ALL MANHOLE RIMS, WATER VALVE BOXES,
UTILITY BOXES AND LIDS, ETC.
FINAL GRADE CERTIFICATION SHALL BE PROVIDED TO THE BUILDING AND SAFETY
INSPECTOR PRIOR TO FINAL INSPECTION.
TOP OF STRUCTURAL
PA VEMEN T SUBGRADE
N�
1: 1 SLOPE OR FLATTER
OR ADEQUATE SHORING
\�
\/
ATTN: BRIAN WREN
90% COMPACTED
NATIVE BACKFILL
\�
6" MAX. SIZE
GRANULAR BEDDING FROM /
SELECTED TRENCH SIDE
-------------
7
MATERIAL (1- MAX. SIZE).
-------
9
I I
6" MIN. III =
W N =
-
8 MAX. = I I I
III=
III
1400 E. PHILLIPS BLVD.
o
POMONA, CA. 91766
I
Ln
, III
SO. CALIFORNIA EDISON COMPANY
I
7951 REDWOOD AVE.
FONTANA WATER COMPANY
FONTANA, CA. 92335
(909) 820-5598 - UNDERGROUND
ATTN: MICHAEL J. McGRAW
II
'
STORM DRAIN PIPE
I I E I I F
(909) 357-6233 - DISTRIBUTION
GRANULAR BEDDING FROM SELECTED
CRAWFORD CANYON MUTUAL WATER CO.
TRENCH SIDE MA TERIAL FOR PIPE
ATTN: BASIL J. FABRIZIO
10' OR GREATER IN DEPTH USE
(909) 463-9580
1/2" CRUSHED STONE BEDDING.
EA
TRENCH DE TA lL
NOTES NOT TO SCALE
1. TRENCH WIDTH SHALL BE CONTROLLED 4. COMPACTION SHALL BE 90% IN ALL
TO TOP OF PIPE ZONE. ZONES UNLESS OTHERWISE SPECIFIED.
2. TRENCH DEPTHS OF GREA TER THAN 5' TRENCH STABILITY SHALL CONFORM
SHALL HAVE ADEQUATE SHORING. TO CAL -OSHA REQUIREMENTS.
J. CLASS 11 AGG.BASE ALL TRENCHES
LESS THAN 100' IN LENGTH.
I I �
FUTURE SCHOOL SITE
-�� 1�----------,�---ter-cry--_----
-------1PRRR_1_0=-L4_L--32__---___- --
may---------�- = =I -- -----------------------
5 ------ -- ------ --- � --
Kl-7l3X
I, 3
I Ii i I
ail � 1 I
'2
ADELPHIA (CABLE 7V)
ATTN: BRIAN WREN
ATTN: JACK HAYES
8353 SIERRA AVENUE
1205 DUPONT AVENUE
FONTANA, CA 92335
(909) 350-6632
ONTARIO, CA. 91761
---
6
-------------
7
I
8
-------
9
----
10
I
------
11
-------- -
12
------ --------- -----------------`-----
13 14 I
FONTANA, CA. 92335
1400 E. PHILLIPS BLVD.
909 428-8411
EMERGENCIES: (800) 427-2200
POMONA, CA. 91766
INSTALL 18" R.C.P. STORM DRAIN (D LOAD SHOWN ON PLAN).
(909) 469-6327
SO. CALIFORNIA EDISON COMPANY
I
II I I I I i \� - s -- --- -• - -- � � -- -
1 ( II
-
Lv
- 36 I I
�� �
- - -y- --------
Z)
1_ ---
4_ 5
�- 51 _50
14�LAGUNA 37 39 40 41 I 43 I 45
LIME A ' I
I I
I 1
�l i 11 35 1 mN 38 1 »1 m� I
I1 ------ Q LAP A-2 w I
II I I� I I I I ;_
1I1 I I I' r _SWE'T _
LAf 'A -J"! I 1
I I I I ,� m
-------------- I I I I I I 3 Q 32
II I I I1 i 1 31 30 = 29 28 27 I 26 1 25
-------------- '- - -- - - --- -+ -- -- ,----- ----:�...-- --�.�.
1 i LINE "B3-9" FUTURE DEVELOPMENT
A.P.N. 239-141-11
959 COMPACTED
NATIVE BACKFILL
3" MAX. SIZE
SHEET INDEX
SCALE: 1 "=150'
NOTES:
16
_ 1
1
17
49---48-- 3 --------
46 47 18 i ,!
I
- - 19
I fy
I
20
I
1
24 23 22 21
A. IF ANY EXISTING STRUCTURES, LANDSCAPING, UTILITIES OR OTHER FACILITIES ARE
DAMAGED OR REMOVED DUE TO CONSTRUCTION ACTIVITIES, THE CONTRACTOR
SHALL BE RESPONSIBLE FOR THE COORDINATION AND REPLACEMENT
B. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION AND RESTORATION
OF EXISTING IMPROVEMENTS IN ACCORDANCE WITH SECTION 7 OF THE STANDARD
SPECIFICATION FOR PUBLIC WORKS CONSTRUCTION.
RECORD D Vv`,l! b oE�ss
THESE
PAR`, i i F. -D AND
FURNISHED Cy, OTHERS. THE ENGIN -ER VM1 NOT BE
RESPONSIBLE FOR ANY ERRORS OR OMISSIONS WHICH a No. 36631
HAVE BEEN INCORPORATED INTO THE DOCUMENTS AS ' ° Iuv(A SQ=lh
I A RESULT THEREOF.
CITY OF FONTANA UTILITY NOTIFICATION LIST
CITY OF FONTANA
ADELPHIA (CABLE 7V)
ATTN: BRIAN WREN
ATTN: JACK HAYES
8353 SIERRA AVENUE
1205 DUPONT AVENUE
FONTANA, CA 92335
(909) 350-6632
ONTARIO, CA. 91761
2 OF
(909) 390-4738
SO. CALIFORNIA GAS COMPANY
3 OF
ATTN: JACK JARVIS
VERIZON
16231 VALLEY BLVD.
ATTN: STEVE HOCK
FONTANA, CA. 92335
1400 E. PHILLIPS BLVD.
909 428-8411
EMERGENCIES: (800) 427-2200
POMONA, CA. 91766
INSTALL 18" R.C.P. STORM DRAIN (D LOAD SHOWN ON PLAN).
(909) 469-6327
SO. CALIFORNIA EDISON COMPANY
FINISH SURFACE
7951 REDWOOD AVE.
FONTANA WATER COMPANY
FONTANA, CA. 92335
(909) 820-5598 - UNDERGROUND
ATTN: MICHAEL J. McGRAW
(909) 875-5100 - TRANSMISSIONS
8440 NUEVO AVENUE
(213) 637-1233 - PIPELINES
FONTANA, CA 92335
(909) 357-6233 - DISTRIBUTION
TEL: (909) 822-2201
CRAWFORD CANYON MUTUAL WATER CO.
FAX: (909) 823-5046
ATTN: BASIL J. FABRIZIO
(909) 463-9580
5
EA
WEST VALLEY WATER DISTRICT
WEST SAN BERNARDINO WATER
ATTN: LON TSAI
UNDERGROUND SERVICE ALERT
56
(800) 422-4133
855 W. BASELINE ROAD
RIALTO, CA 92377
SBC
A TTN: JAMES ZIELINSKI
1265 N. VAN BUREN STREET
SUI TE 180
ANAHEIM, CA 92807
(714) 666-5415
SAN GABRIEL VALLEY
MUNICIPAL WATER DISTRICT
ATTN: DAVE JOHNSON
549 EAST SIERRA MADRE AVENUE
AZUSA, CA. 91702-1299
P.O. BOX 1299
(909) 969-7911
CONSTRUCTION NOTES:
s
Q
CASA GRANDE
� -
W --
J
SU AlIT AVE UE y
CEFa-
V� \ gxq
VICINITY MAP
N. T S.
QTY & UNIT:
ASPHAL TIC CONCRETE
SHEET INDEX
SHEET
DESCRIPTION
1 OF
4
TITLE SHEET
2 OF
4
LINE A FROM 10+00.00 TO 14+04.10
LINE "B3-9" FROM 10+45.83 TO 11+01.8J
3 OF
4
DETAIL SHEET
4 OF
4
DETAIL SHEET
QTY & UNIT:
0 WNER/DEVEL OPER:
NORTH FONTANA INVESTMENT COMPANY, LLC
1156 N. MOUNTAIN AVENUE
UPLAND, CA. 91785-0670
P.O. BOX 670
PHONE: (909) 985-0971
NO TE.
LOCATIONS OF LINES AND LATERALS AND STREET CONNECTIONS HAVE NOT BEEN
APPROVED. LOCAL STORM DRAIN LINE AND LATERAL CONNECTIONS MAY CHANGE UPON
CITY/FIRE REVIEW OF TENTATIVES ONCE THEY ARE FORMALLY SUBMITTED FOR CITY
REVIEW.
LEGEND
A. C.
ASPHAL TIC CONCRETE
INSTALL 36" R.C.P. STORM DRAIN (D LOAD SHOWN ON PLAN).
32
LF
+ 134 LF
B. W
BACK SIDEWALK
INSTALL 30" R.C.P. STORM DRAIN (D LOAD SHOWN ON PLAN).
71
LF
CENTERLINE
E. C.
3�
INSTALL 24" R.C.P. STORM DRAIN (D LOAD SHOWN ON PLAN).
409
LF
11
E. V. C.
4�
INSTALL 18" R.C.P. STORM DRAIN (D LOAD SHOWN ON PLAN).
33
LF
FINISH SURFACE
G. B.
GRADE BREAK
CONSTRUCT TRANSITION STRUCTURE PER APWA STD. 340-1 DETAIL ON SHEET 3
1
EA
INVERT
0. C.
ON CURVE
CONSTRUCT MANHOLE PER A.P.W.A. STD. PLAN 321-1 DETAIL ON SHEET 3
2
EA
CONSTRUCT CURB OPENING CATCH BASIN PER APWA STD. 300-2 DETAIL ON SHEET 3
5
EA
INSTALL 42" R.C.P. STORM DRAIN (D LOAD SHOWN ON PLAN).
56
LF
�8
(p
�J
/ ATC Hann 01 CT &�E- q pIVC/ /AIN C/ Gaq 4 D WATCO
/' G11.AK�, TO�h/l G7YGA
�i
1
�D
CT
ZL
1
unn/TICK S 9iGWAr ON car r�r�A
nr�i�FAT GT�D/�n 110, ANO
�E
10
,
G(96WP/,� ROAD DEPAR4��T D41G. Z'209 ON zqLC;E7_T_ j
ZL
11
PLACE 375 # ROCK RIPRAP 3 FEET DEEP
868
SF
12 CONSTRUCT PCC COLLAR PER APWA STD. 380-2 DETAIL ON SHEET 4
1
EA
+ 1 EA
PLACE 100# ROCK RIP -RAP CONCRETED 2' THICK
1,450
SF
PER GREEN BOOK SECTION 200-1.6 & 300-11.
14
CONSTRUCT TRANSITION STRUCTURE PER CITY STD. PLAN 3026.
1
EA
15
CONSTRUCT MANHOLE PER CITY STD. PLAN 3012.
2
EA
16
CONSTRUCT CONCRETE COLLAR PER CITY STD. PLAN 3022.
1
EA
CONSTRUCT 24" CSP RISER & GRATE ASSEMBLY PER DETAIL ON SHT. 4 OF 4.
1
EA
1
18
INSTALL 12" D.I.P.
14
LF
19
CONSTRUCT ROCK BERM PER DETAIL 4A ON SHT 4 OF 4.
30
LF
CONSTRUCT MODIFIED BASE OF MANHOLE PER DETAIL 4E ON SHT 4 OF 4.
1
EA
PLACE 6" ROCK MIN. 12" THICK.
150
SF
REMOVE EXIST CONCRETED ROCK AS NECESSARY. REPLACE CONCRETED ROCK
LS
CONCTRUCT CONCRETE PIPE ANCHOR PER DETAIL ON SHT 2 OF 4.
2
EA
0 WNER/DEVEL OPER:
NORTH FONTANA INVESTMENT COMPANY, LLC
1156 N. MOUNTAIN AVENUE
UPLAND, CA. 91785-0670
P.O. BOX 670
PHONE: (909) 985-0971
NO TE.
LOCATIONS OF LINES AND LATERALS AND STREET CONNECTIONS HAVE NOT BEEN
APPROVED. LOCAL STORM DRAIN LINE AND LATERAL CONNECTIONS MAY CHANGE UPON
CITY/FIRE REVIEW OF TENTATIVES ONCE THEY ARE FORMALLY SUBMITTED FOR CITY
REVIEW.
LEGEND
A. C.
ASPHAL TIC CONCRETE
B. C.
BEGIN CURVE
B. V. C.
BEG. VERTICAL CURVE
B. W
BACK SIDEWALK
C.B.
CATCH BASIN
C. L.
CENTERLINE
E. C.
END CURVE
E. P.
EDGE PA VEMEN T
E. G.
EDGE GRADE
E. V. C.
END VERTICAL CURVE
F. L.
FLOW LINE
F. S.
FINISH SURFACE
G. B.
GRADE BREAK
H. P.
HIGH POINT
INV.
INVERT
0. C.
ON CURVE
T O. R.
TOP OF ROCK
P.C.C.
PORTLAND CEMENT CONCRETE
(R)
RIDGE LINE
R/W
RIGHT OF WAY
TAN.
TANGENT
T C.
TOP OF CURB
W
WID TH
V
VERTICAL DEPTH
(590.69)
INDICATES EXISTING ELEVATION
590.69
INDICATES PROPOSED ELEVATION
INDICATES SLOPE 2:1
D
AC PA VEMEN T
REMOVAL
GRIND
EDGE OF PAVEMENT
ti