HomeMy WebLinkAbout3912-3LEGEND:
TOP OF CURB ELEV
FLOWLINE ELEV
FINISH SURFACE ELEV
EXISTING
FINISH SURFACE ELEV
RIGHT OF WAY
TRACT BOUNDARY
PROPOSED AC PAVEMENT
PROPOSED AC OVERLAY
PROPOSED STREET LIGHTS
PER STREET LIGHT PLANS
Efwiil6
XX.XX FL
XX.XX
FS
xx.xx
FS
CURVE DATA
NO.
RADIUSLENGTH
TANGENT
DELTA
C2
25.00'
39.25'
35.09'
89057'13"
C3
112.00
31.79
16.00
tiv
C4
112.00'
N
16.00'
16'15'35"
h
CURVE DATA
NO.
RADIUSLENGTH
TANGENT
DELTA
C2
25.00'
39.25'
35.09'
89057'13"
C3
112.00
31.79
16.00
16015'39"
C4
112.00'
31.78'
16.00'
16'15'35"
C5
38.00'
140.95'
130.29'
212'31'13"
�u
R/W PER TR 16743
.'9
IMPROVEMENTS
FO 0. 0-3 G V=; PER TR 1.6743
•59.80 WIL MS ROAD=-DW6..,-]No3834
4:
IMPROVEMENTS
'PER TR A6743
DWG. No.3834
r
7F'1C7 167A3
`Mt
UNDERGROUND SERVICE ALERT rctvl�lulv� SHOULD CONSTRUCTION OF THE REQUIRED,
IMPROVEMENTS NOT COMMENCE WITHIN TWO
do CALL:TOLL FREE YEARS OF THE DATE OF APPROVAL SHOWN ",
HEREON AND CARRIED FORTH IN A DILIGENTNo. C45935 c
" 227 $2 00 MANNER, THE CITY ENGINEER MAY REQUIRE
* Exp. 12/31 /08 '
ecoa szA��N� 3 o REVISIONS TO THE PLANS TO BRING THEM INTO ,,�,P
TWO WORKING DAYS BEFORE YOU DIG MARK DESCRIPTION APPR. DATE CITY APPR. DATE CONFORMANCE WITH STANDARDS IN EFFECT. C°`
CONSTRUCTION NOTES
@2 CONSTRUCT 6" CURB AND GUTTER PER
CITY OF FONTANA STANDARD #1003
O3 SAWCUT EXISTING AC PAVEMENT TO
PROVIDE A CLEAN, STRAIGHT MATCHING EDGE
O5 PLACE MIN. 4" AC OVER 12" MIN. COMPACTED
NATIVE SUBGRADE (95%)
O7 CONSTRUCT CURB RETURN ACCESS RAMP PER
CITY OF FONTANA STANDARD #1006
8 CONSTRUCT SIDEWALK PER
CITY OF FONTANA STANDARD #1015
1�0 WATER VALVE, HYDRANT AND MAIN (BY OTHERS)(FONTANA WATER CO.)
O1 REMOVEEXISTING AC DIKE PER TRACT NO. 16743 PLANS
DWG. No.3834
INSTALL STREET LIGHT PER STREET LIGHTING PLAN DWG. NO.3912-LT
'ro(L ,z�
0g10 710 0
LOCKW OOD ENGINEERING CO.
380 W. FOOTHILL BOULEVARD STE. F
RIALTO, CALIFORNIA 92376
(909) 875-5015 FAX (909) 875-4567
N
SCALE
40 0 20 40 80
( 1N FEET )
1 inch = 40 ft.
CITY OF FONTANA, CALIFORNIA
STREET IMPROVEMENT PLAN
DRAWN BY: SCALE: HORIZ. 1"=40'
A.M T T 16579 VERT. 1"=4'
PLDATED:
DESIGNED BY: VE ACE
A.M 10/20/05
-17
CHECKED BY ,Q APPRo4�j:6 R. No. SHEET
C.W.L. 3912 3 OF 4
QlY ENGINEER 213 1
`
r
�u
R/W PER TR 16743
.'9
IMPROVEMENTS
FO 0. 0-3 G V=; PER TR 1.6743
•59.80 WIL MS ROAD=-DW6..,-]No3834
4:
IMPROVEMENTS
'PER TR A6743
DWG. No.3834
r
7F'1C7 167A3
`Mt
UNDERGROUND SERVICE ALERT rctvl�lulv� SHOULD CONSTRUCTION OF THE REQUIRED,
IMPROVEMENTS NOT COMMENCE WITHIN TWO
do CALL:TOLL FREE YEARS OF THE DATE OF APPROVAL SHOWN ",
HEREON AND CARRIED FORTH IN A DILIGENTNo. C45935 c
" 227 $2 00 MANNER, THE CITY ENGINEER MAY REQUIRE
* Exp. 12/31 /08 '
ecoa szA��N� 3 o REVISIONS TO THE PLANS TO BRING THEM INTO ,,�,P
TWO WORKING DAYS BEFORE YOU DIG MARK DESCRIPTION APPR. DATE CITY APPR. DATE CONFORMANCE WITH STANDARDS IN EFFECT. C°`
CONSTRUCTION NOTES
@2 CONSTRUCT 6" CURB AND GUTTER PER
CITY OF FONTANA STANDARD #1003
O3 SAWCUT EXISTING AC PAVEMENT TO
PROVIDE A CLEAN, STRAIGHT MATCHING EDGE
O5 PLACE MIN. 4" AC OVER 12" MIN. COMPACTED
NATIVE SUBGRADE (95%)
O7 CONSTRUCT CURB RETURN ACCESS RAMP PER
CITY OF FONTANA STANDARD #1006
8 CONSTRUCT SIDEWALK PER
CITY OF FONTANA STANDARD #1015
1�0 WATER VALVE, HYDRANT AND MAIN (BY OTHERS)(FONTANA WATER CO.)
O1 REMOVEEXISTING AC DIKE PER TRACT NO. 16743 PLANS
DWG. No.3834
INSTALL STREET LIGHT PER STREET LIGHTING PLAN DWG. NO.3912-LT
'ro(L ,z�
0g10 710 0
LOCKW OOD ENGINEERING CO.
380 W. FOOTHILL BOULEVARD STE. F
RIALTO, CALIFORNIA 92376
(909) 875-5015 FAX (909) 875-4567
N
SCALE
40 0 20 40 80
( 1N FEET )
1 inch = 40 ft.
CITY OF FONTANA, CALIFORNIA
STREET IMPROVEMENT PLAN
DRAWN BY: SCALE: HORIZ. 1"=40'
A.M T T 16579 VERT. 1"=4'
PLDATED:
DESIGNED BY: VE ACE
A.M 10/20/05
-17
CHECKED BY ,Q APPRo4�j:6 R. No. SHEET
C.W.L. 3912 3 OF 4
QlY ENGINEER 213 1