Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
3902-4
J E NOTE: - Q THE CONTRACTOR a o SHALL OFF -SET THE STRONG BOX a a CONC. CURB TO CONFORM ENCLOSURE PER LEGEND. 0 o 1 � FINISH GRADE TO THE BACKFLOW O SEE BACKFLOW DETAIL -2 Jo a 1 IN TURF AREAS 1 DEVICE CONFIGURATION 3 THIS SHEET Q Z Q o 2 IN GROUNDCOVER 4 DEPTH OF PEA GRAVEL AS SHOWN. (OMIT VALVE o 3 3O CONTROLLER INSTALLED IN 2 PLAN BOX, DET. C) z 0 Y 4 6 HEAVY DUTY STAINLESS 3 42"=I- 4 CONCRETE BASE W/ z a STEEL CONTROLLER ENCLOSURE SHALL BE PER SIZE PER BACKFLOW IN FIELD ENCLOSURE ANCHORS MED. x LEGEND AND INSTALLED PER MANUF. INSTRUCTONS ''' i , , _, < - .. J`' f 'T�,:'=: BROOM FIN. 6" DEEP MIN. RECOMPACTED SUB- GRADE PER STRUCT.\/ a z C0NTRoii.ER ® WALL MOUNT CONTROLLER FINISH GRADE y'�' i }: _ ✓;lY{ ,F;� ,, ,; 1 - ^' _ SOILS REPORT. Z ? 4 PER LEGEND. INSTALL i`//\// \//\// 1 IN TURF AREAS nil nl - N ©c3' RE --BAR CONT 1N PER MANUF. INSTRUCTIONS \/\ \ q \/\\ \ 2 IN GROUND COVER -; `- r wr. > > > ` �r, ;'�l ;' ;S ,i�„; CONC. TYP. 00 5 ANCHOR BOLTS PER / // Z // AREAS ,�� \\ \ \\ \\ 5 MANUF. SPECS. \\\ ,� 3� ROUND PLASTIC VALVE BOX. BROOKS, AMETEK ® 2” IRRIGATION CONTROL WIRE CONDUIT AND o0 6 OR EQUAL WITH 30" 3 1 L 3 /\\// //\\//\\/ /\/ 5 9 CONTROL WIRES 0 3/4" 120 VOLT CONDUIT LOCKING COVER MARKED "G.V." 4 Co AND WIRE Q TYP ' •- v % ®2" CAPPED CONDUIT EXTENSION /\ /\ 3 , ��r , iJ� / FOR FUTURE USE 5� GATE VALVE PER FLOW 2 O \ LEGEND PVC MALE ADAPTER �\ \ \ \ \/ \/\/\/\/� L� Z y TWO (2) REQUIRED 4 / - k ,� � 0 PVC MAINLINE 1 PRESSURE MAN LINE PIPING. ' - �i ;� ,� �i � 8 PER LEGEND f� 2 NON PRESSURE LATERAL PIPING. ff //\//\//\ 1 �. ®fi MIN. PEA GRAVEL N fi 3 PROVIDE 2 DEPTH OF CLEAN BACKFILL. g BRICK 1 OF 2 4 COMPLACTED BACKFILL - SEE IRRIGATION SPECIFICATIONS • 5 CONTROL WIRES - BUNDLE AND TAPE EVERY 10' AND INSTALL ADJACENT TO " 2» 30" MN e: �;, �f �,� ;=; �t,rr <�� ,/ ,, -� �✓ , .J. n. `r _�. s J , s, TO PRESSURE MAIN LINE. FINISH GRADE. N OTE: CONTRACTOR RESPONSIBLE FOR \\�\\\/\\��\\\/�\\\�\\\\\ \\\\ NOTE: ALL ELECTRICAL HOOK-UP FROM �� /�/\/\/ /i�/i• � �� �� PROVIDE 6 SIDE SEPARATION AND A MINIMUM OF 3 VERTICAL ELECTRICAL P.O.C. TO CONTORLLER :; •. SEPARATION BETWEEN MAIN LINE AND LATERAL LINE INSTALLED IN • THE SAME TRENCH. SECTION N.T.S. CONTROLLER D ENCLOSURE 6 TE LVE N.T.S. AC FLS LY COVER N.T.S. N.T.S. TRENCHING Id -0068 id -0045a id-ao�1 iTREN1.DWG 0 PVC LATERAL LINE PER LEGEND 1 FINISH GRADE 2 1 " IN TURF AREAS 1 3" AT EDGE OF PAVING 0 3 2" IN GROUNDCOVER AREAS 1 REDUCED PRESSURE OR WALL 4 O WIRE CONNECTORS PER BACKFLOW ASSEMBLY 4 NOTES 2 WITH BALL VALVES �2 POP-UP HEAD PER LEGEND 5 �5 RECTANGULAR PLASTIC PER LEGEND AND WYE STRAINER 1 �3 FINISH GRADE g VALVE BOX - BROOKS, 2 NIPPLE (ONE REQUIRED O 0 2 ® 1 " IN TURF AREAS, 2" IN -7AMETEK OR EQUAL W/ LOCKING COVER MARKED EACH SIDE BRASS } 3� 90 DEGREE ELL 3 GROUND COVER 8 BY HEAT BRANDING 2" HIGH LETTERING W/ FLOW 11 --'- (ONE REQUIRED EACH 36„ U5 PVC NIPPLE 4 SIDE) BRASS LENGTH AS REQ. (2"MIN) CONTROLLER STA. NUMBER 9" : ' 24" : ' 9" ® PVC ELL \/ / / / © ELECTRIC VALVE PER LEGEND REDUCE MAINLINE IZE 2 O HERE IF - NECESSARY MARLEX STREET ELL\\/ //\� 0 PVC MALE ADAPTER 5 UNION (ONE REQUIRED 1 CONTROLLER ENCLOSURE 0 \\ \\ \ \\' \//\//\/ 9 8 0 PVC SCH.80 3" NIPPLE N 1 EACH .SIDE) BRASS �// // //\/ /\/\/\ ® PVC LATERAL LINE © HEIGHT PER CODE 2 O CONCRETEPAD \/\/\ 5 \\\\/�%\/ \\//\\/ PER LEGEND oo 0 r O BALL o WITH SUPPLIED �\ /\ / 6 PVC LATERAL LINE 2" VALVE 6 7 PVC COUPLING ONE o '- MOUNTING BASE. FITTING © PVC 90 DEG. ELL - REQUIRED EACH SIDE) / I �3 CONCRETE STEPPING PAD 24 X24 X2 CENTERED ON CONCRETE ENCLOSURE. N 7 6' NOTES: 1. ALL PVC THREADED 1 1 D D 11 EXP NOSIION I CUR WITH �_� `) — E."t I, I=I I ° o I I 2 O PER MAINLINE LEGEND — _I I I I=I I I 0QQ__ o� 00o e I- 7 P G II POUR IN PLACE / CONNECTIONS TO BE 2 PVC MAINLINE (PER = °o � „ I I— COATED WITH RECTOR ) AND FITTINGS 0 o� �° 12 CUBE MINIMUM 5 LEGEND 4� III=� CONCRETE THRUST BLK • SEAL T -PLUS TWO 0 R EQUAL 12 03 (CONTROL WIRE W/ �_) �_!=1 I �_1 j ( •'III=I ((=III=I I (=III=III I I •• 10 RECTANGULAR `JUMBO' — — _ _ a 2. PROVIDE PURPLE CAPS 13 EXPANSION CURL (INSTALL WIRE PER •. , , • (I I -III, ; I I I=III=I I—III, , : •'_ PLASTIC VALVE BOX �I I I=� I E— i � � BROOKS, AMTEK OR . cv M FOR ALL HEADS ON 14 _ LOCAL' CODE BUNDLE 8 EQUAL FILL WITH PEA —� RECLAIMED SYSTEMS AND TAPE PER NOTES) SECTION 2 GRAVEL AS SHOWN 9 1 14 6" MIN. PEA GRAVEL NOT TO SCALE (OMIT -LID) 3 NOTES: 1. ALL PVC PIPE THREADS 3. BUNDLE AND TAPE WIRE 15 BRICK (1 OF 4) 11 PRESSURE REGULATOR NOTE: TO BE COATED W/ "RECTOR PER NOTES 1. ALL METAL TREADS SHALL BE 9 12 830 SERIES HAMMOND „ ,� in 6 24 6 �� SEAL T -PLUS TWO OR 4. PROVIDE PURPLE VALVE I i WRAPPED WITH TEFLON TAPE 10 THREADED ENDS BALL EQUAL. BOX LIDS FOR RECLAIMED � 2. FOR BACKFLOW ENCLOSURE VALVE THIS SHEET 2. EXPANSION CURL WRAP WATER SYSTEMS SEE DETAIL 4 WIRE AROUND 1/2" DIA. PIPE 15 TIMES. - N.T.S. CONTROLLERA N.T.S. POP-UP H W.T.S.D—Popuphead.dwg 5 MASTER VALVE REMOTE CONTROL VALVE N.T.S. id 2 BACKFLOWASSEMBLY / 'Y' STRAINERPRESSURE REGULATOR id -0069 -0039a 1 1� FINISH GRADE 2 2� 299 IN GROUNDCOVER, IN TURF AREAS y 3 INSTALL QUICK COUPLER IN ROUND 4 PLASTIC VALVE BOX BROOKS QUAL WITH LOCKING EQUAL COVER MARKED BY HEAT RANDING 2 HIGH BETTERING W/ QC 4� QUICK COUPLER PER LEGEND. INSTALL IN 2» 12 GROUND COVER AREA 00 WHENEVER POSSIBLE O 6" MIN. PEA _GRAVEL D D D D D D 5 © PVC SCH. 80 NIPPLE LENGTH AS REQUIRED D D D D D 6 PVC MAINLINE 7 ® PVC ELL (TXT) MARLEX STREET ELLS TWO (2) REQUIRED • j4 o- ( � � ���X � 10 C PV�� SCH. 80 9 10 NIPPLE 0"`5 err �* , ' w k o. 11 PVC MAINLINE FITTING 10 ...s u = 1 1 � WOOD OR # 3 REBAR p. 31 QUICK COUPLER N.T.S. id -0038 CITYF17A aON I umw& I G` A LERT PREPARED UNDER THE SUPERVISION OF: 'ETAILS SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO T o IRRIGATION —1. DRAWN BY: VILLAGE OF HERITAGE DIAL TOLL FREE YEARS OF THE DATE OF APPROVAL SHOWN X779 3901 suite#»� n SCALE: land arc + west NewpWestort Newport Beach, CA 92660 , LIC. No. 4340 Tel: 1-800-227-2600 AT LEAST TWO DAYS BEFORE You DIG HEREON AND CARRIED FORTH IN A DILIGENT MANNER. THE CITY ENGINEER MAY REQUIRET-� REVISIONS TO THE PLANS TO BRING THEM INTO* � o� S.C./ N.B. DESIGNED BY: TENTATIVE TRACT 16318 PLAN SET A.2 DATE: PL01 DATE: (949)224-0040 � . , J.M.H. LMA L.AN®APE PLAN 10.08.04 6.16.05 Fax: (949) 224-004.4 CONFORMANCE WITH CONDITIONS AND N ee®. Q• �'Sj� DATE: 1 J� 4, C-; kr �v-C._ .Jt Ke` S 5--ZZ-61 5 CHECKED BY: APP OVER SY / DATE: c DRAWING NO: 4• UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA STANDARDS IN EFFECT. ��` •C �' CALIF REV. REVISION DESCRIPTION i DATE CITY DATE P.T.W. c•c/ x•3902 CITY ENGINEER # 51152 J E