HomeMy WebLinkAbout3878-1GENERAL SEWER NOTES
1 ALL WORK THE CONRACTLPROVISIONS CAOND ATHE L BE IN ACRDNCE S ANDARD S EC�IFICATIONS IFORTH THESE PLNS, THE CTYOPUB� CT WORKS ACONS RUCTION / CITY OF FONTANA CiALIFORNIA
("GREEN BOOK"). ALL REFERENCE SPECIFICATIONS AND STANDARDS SHALL BE THE LATEST EDITION
UNLESS OTHERWISE NOTED.
2 WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CANNOT BE
RESOLVED BY REFERENCE TO PRECEDENCE PROVISIONS IN THE "GREEN BOOK", THE CONTRACTOR SEWER IMPROVEMENT PLANS
SHALL IMMEDIATELY REPORT SAID CONFLICT TO THE CITY ENGINEER FOR RESOLUTION.
3 ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER.
4 CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVELOPMENT
DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION
SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC
RIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL (909) 350-7610.
5 THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND PROCEDURES
DESCRIBED IN THE STATE OF CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST NON -METRIC EDITION
UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER.
6 IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS OR
OTHER TRAFFIC CONTROL DEVICES AT ALL TIMES.
7 THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK FOR TRENCHES
5 FEET OR GREATER IN DEPTH FROM THE CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY.
8 THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE GUARDED
BY SHORING, SLOPING OF THE GROUND OR OTHER APPROVED MEANS PURSUANT TO THE REQUIREMENTS OF
THE DIVISION OF INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA. TRENCHES LESS THAN FIVE (5) FEET
SHALL ALSO BE GUARDED WHEN THE POTENTIAL EXISTS FOR GROUND MOVEMENT.
9 NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT OF WAY WITHOUT OBTAINING A SEPARATE
PERMIT FOR THAT PURPOSE.
10 THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION, HOWEVER, IT
SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE, IN THE FIELD, THE TRUE LOCATION
AND ELEVATION OF ANY EXISTING UTILITIES, AND TO EXERCISE PROPER PERCAUTION TO AVOID DAMAGE THERETO. THE
CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT AT 1-800-227-2600 TWO WORKING DAYS BEFORE
EXCAVATION.
11 THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES INCLUDING, BUT NOT
LIMITED TO, GAS, TELEPHONE, ELECTRIC, CABLE TELEVISION, LANDSCAPING, LANDSCAPE IRRIGATION, DOMESTIC WATER,
RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND CALTRANS. ALL UTLITIES COMPANIES SHALL BE GIVEN
TWO WORKING DAYS NOTICE PRIOR TO WORK AROUND THEIR FACILITIES.
12 THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES WITHOUT APPROPRIATE
AGENCY AUTHCRIZATION. CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE WATER COMPANY FOR VALVE
OPERATION AND WATER REQUIREMENTS.
13 STATIONING REFERS TO THE CENTERLINE OF SEWER EXCEPT WHERE OTHERWISE NOTED.
14 ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE CONTRACTOR TO
CnNSTRUCT THE WORK TO THE PLAN GRADES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PRESERVATION
OF BENCHMARKS AND CONSTRUCTION CONTROL STAKING DURING CONSTRUCTION.
15 THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT TIES OR BENCH MARKS WITHOUT
PRIOR NOTIFICATION TO THE CITY ENGINEER.
16 REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING SURVEY MONUMENTS, MONUMENT TIES AND
BENCH MARKS, SHALL BE DONE BY A REGISTERED CIVIL ENGINEER OR LICENSED LAND SURVEYOR. SURVEY
MONUMENTS THAT WILL BE DESTROYED AS A RESULT OF THIS CONSTRUCTION SHALL BE REPLACED, THE
CONTRACTOR SHALL NOTIFY THE ENGINEER ONE WEEK PRIOR TO CONSTRUCTION SO THAT TIES TO MONUMENTS
CAN BE ESTABLISHED FOR LATER REPLACEMENT OF THE MONUMENT.
17 THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES. A MINIMUM
12 FnOT LANE SHALL BE MAINTAINED AT ALL TIMES IN THE CONSTRUCTION AREA FOR RESIDENTS AND EMERGENCY
VEHICLES.
18 THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL, INCLUDING ADEQUATE
WATERING, AT ALL TIMES.
19 THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR DEBRIS TO BE DEPOSITED ONTO PUBLIC OR
PRIVATE PROPERTY ADJACENT TO THE RIGHT OF WAY DURING CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL.
20 NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR.
21 A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION. FAILURE TO OBTAIN THE REQUIRED DENSITY
SHALL REQUIRE RE -WORKING OF THAT PORTION OF THE WORK UNTIL THE SPECIFIED DENSITY IS OBTAINED.
22 CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING STREET IMPROVEMENTS. UPON
INSPECTION OF THE SITE, THE CITY ENGINEER MAY REQUIRED TEMPORARY NON-ERODEABLE SWALES ENTERING OR LEAVING
IMPROVEMENTS.
23 ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH TO MATCH EXISTING CONCRETE.
24 IF SEWER CONSTRUCTION IS TO BE DONE IN PHASES, THE CONTRACTOR SHALL PROVIDE A TERMINAL CLEANOUT AT THE PHASE
BOUNDARY, NO MORE THAN 150 FEET FROM THE DOWNSTREAM MANHOLE, SEE CITY OF FONTANA STANDARD DETAIL FOR
TERMINAL CLEANOUT.
25 SANITARY SEWER LINES SHALL BE CONSTRUCTED OF BELL AND SPIGOT OR BAND SEAL TYPE VITRIFIED CLAY PIPE (V.C.P.)
EXTRA STRENGTH CLASS AND SHALL CONFORM TO THE PROVISIONS OF THE ASTM DESIGNATION C700 FOR V.C.P.
26 NO OPEN TRENCH SHALL BE ALLOWED AT THE END OF THE DAY WITHOUT PRIOR APPROVAL OF THE CITY ENGINEER.
27 SHORT VCP STUBS WITH FLEXIBLE COMPRESSION JOINTS SHALL BE USED AT MANHOLE WALLS TO ALLOW FOR MINOR
DEFLECTIONS IN ALIGNMENT.
28 PRiOR TO CONSTRUCTION, THE CONTRACTOR SHALL EXPOSE EXISTING FACILITIES, AND VERIFY ELEVATION AND LOCATION OF
CONNECTIONS. CITY APPROVAL OF CONNECTIONS TO EXISTING FACILITIES DOES NOT IMPLY CORRECTNESS OF ELEVATIONS OR
LOCATIONS SHOWN ON THE PLANS.
29 ALL 4" HOUSE LATERALS SHALL BE INSTALLED AT A 2% MINIMUM GRADE UNLESS OTHERWISE APPROVED BY THE CITY ENGINEER.
30 TERMINATE ALL 4" HOUSE SEWER LATERALS 3 FEET INSIDE THE LOT WITH A PLUG 12" BELOW THE GROUND SURFACE. WHEN
PUBLIC UTILITY EASEMENTS EXIST NEXT TO THE STREET RIGHT OF WAY, THE LATERAL SHALL TERMINATE 3 FEET INSIDE THE LOT
AS MEASURED FROM THE UTILITY EASEMENT.
31 THE SEWER CONTRACTOR SHALL STAMP AN "S" IN THE FACE OF THE CURB AT THE LOCATION OF THE SEWER LATERAL.
32 IF EXISTING UTILITIES OR ANY OTHER FACILITIES CONFLICT WITH THE PROPOSED IMPROVEMENTS, THE CONTRACTOR SHALL NOTIFY
THE ENGINEER AND ALL AFFECTED AGENCIES IMMEDIATELY.
33 NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVF BEEN PLACED, INSPECTED AND APPROVED.
BENCHMARK
SAN BERNARDINO COUNTY
B.M. OF 627, NAVD 88
ELEVATION: 1011.70 FEET
TOLL FREE -qm�- 1-800-227-2600
A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT
FOR TRACT NO. 17021
A AVENM
INDEX MAP
SCALE 1"=80'
OWNER
TEN -NINETY, A CALIFORNIA
LIMITED PARTNERSHIP
470 E. HARRISON STREET
CORONA, VA 92879
(909) 898-1692
APPLICANT/DEVELOPER
FIESTA DEVELOPMENT
470 E. HARRISON STREET
CORONA, CA 92879
(909) 898-1692
BASIS OF BEARING
THE BASIS OF BEARINGS IS BASED UPON THE CENTERLINE
OF JURUPA AVENUE PER TRACT NO. 16110, RECORDED IN
BOOK 283, PAGES 13 THROUGH 17, OF MAPS, RECORDS OF
SAN BERNARDINO COUNTY RECORDER, BEING N 89'06'36" W.
UTILITY AGENCIES
CITY OF FONTANA
8353 SIERRA AVE
FONTANA CA 92335
TELEPHONE (909) 350-7610
SO.CALIF GAS COMPANY -- DISTRIBUTION FACILITIES
16231 VALLEY BLVD.
FONTANA, CA 92335
TELEPHONE (889-9711) OR (800) 422-4133
SO.CALIF GAS COMPANY -- TRASMISSION DEPARTMENT
BREA, CA 92621
TELEPHONE (909) 529-2889 OR (800) 422-4133
SOUTHERN CALIFORNIA EDISON COMPANY
7951 REDWOOD AVENUE
FONTANA, CA 92336
(909) 357-6231 (SO. OF MERRILL)
(909) 357-6223 (NO. OF MERRILL)
(800) 422-4133
Q a a
Q w
Y
O p Q J
W W 3 o
J 2 m W Q.
JURUPA AVE U l___
VICINITY MAP
NO SCALE
SAN BERNARDINO uOUNTY FLOOD CONTOL DISTRICT
825 E. THIRD STREET
SAN BERNARDINO, CA 92408
(909) 383-1665
PACIFIC TELEPHONE AND TELEGRAPH COMPANY
3073 ADAMS STREET
RIVERSIDE, CA 92504NUff C Xt
(714) 359-2585 OR (800)422-4133 ' I
V(f
FONTANA WATER COMPANY RECORD DRAWINGS� PARED sy
8440 NUEVO AVD'UE i MAOOLE s(ASSOCIATES, INC.
P.O. BOX 987 -
FONTANA, CA 92334 RE
(909) 822-2201
34 ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR TO PAVING OF STREETS.
35 APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT PRIOR TO PLACEMENT.
36 ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED TO FINISH GRADE BY THE PAVING
CONTRACTOR UPON COMPLETION OF PAVING.
37 UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING, STRIPING, BARRICADES, AND OTHER TRAFFIC
CONTROL DEVICES TO THE SATISFACTION OF THE CITY TRAFFIC ENGINEER.
38 AS—BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO SHALL PROVIDE RECORD
DRAWINGS TO THE CITY ENGINEER.
GENERAL TELEPHONE COMPANY
245 N. MOUNTAIN AVENUE
POMONA, CA 91766
(213) 357-2257 OR (800)422-4133
REV. REVISION DESCRIPTION DATE ENGR. I CITY DATE
SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT
COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL
SHOWN HEREON AND CARRIED FORTH IN A DILIGENT '.TANNER,
THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO
BRING THEM INTO CONFORMANCE WITH CONDITIONS AND
i REC . DWG. .8 tAr , 111 11AF STANDARDS IN EFFECT.
R.Gp'4'QI�Fy\
w a G m
cc No. 024725 rn
Exp.12/31 /05
Uq� CIVIL
OF (P
CONSTRUCTION NOTES AND QUANTITIES
NO.
ITEM
TOTAL
UNIT
1
INSTALL STANDARD ECCENTRIC MANHOLE PER
3
EA
CITY OF FONTANA STANDARD DETAIL 112.
2
INSTALL 8" EXTRA STRENGTH VITRIFIED CLAY PIPE PER CITY OF
476
LF
FONTANA STANDARDS AND SPECIFICATIONS
3
JOIN EXISTING MANHOLE
1
EA
4
CONSTRUCT 4" SEWER LATERAL AND HOUSE CLEANOUT
720
LF
PER CITY OF FONTANA STD. NO. 125 AND INSTALL SEWER CLEAN-OUT
BOX PER CITY OF FONTANA STD. 125A (IN CONCRETE AREAS) OR
125B (IN LANDSCAPE AREAS).
5
INSTALL 8" D.I. PIPE PER CITY OF FONTANA STANDARDS
113
LF
AND SPECIFICATIONS
6
REMOVE AND ABANDON EXISTING STUB
1
EA
7
NOT USE
8
BOLT DOWN LID PER APWA STD. 210-2, PER DETAIL ON SHEET 3
1
EA
SHEET INDEX MAP
SHEET NO.
DESCRIPTION
1
TITLE SHEET
2
COLBY PLACE STA 30+00.00 TO 35+96.10
SAFETY RESPONSIBILITY
CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB
SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT, INCLUDING SAFETY
OF ALL PERSONS AND PROPERTY, THAT THE REQUIREMENTS SHALL APPLY CONTINUOUSLY AND
NOT BE LIMITED TO NORMAL WORKING HOURS; AND THAT THE CONTRACTOR SHALL DEFEND,
INDEMNIFY AND HOLD THE OWNER AND THE ENGINEER HARMLESS FROM ANY AND ALL LIABILITY,
REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT,
EXCEPTING FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER OR THE
ENGINEER.
EXISTING UNDERGROUND STRUCTURES
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITIES OR STRUCTURES SHOWN IN
THESE PLANS ARE OBTAINED BY A SEARCH OF AVAILABLE RECORDS. TO THE BEST OF OUR
KNOWLEDGE, THERE ARE NO EXISTING UTILITIES EXCEPT AS SHOWN ON THESE PLANS. THE
CONTRACTOR IS REQUIRED TO TAKE ALL PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES
SHOWN, AND ANY OTHER LINES OR STRUCTURES NOT SHOWN ON THESE PLANS, AND IS
RESPONSIBLE FOR THE PROTECTION OF, AND ANY DAMAGE TO THESE LINES OR STRUCTURES.
THE CONTRACTOR SHALL CALL DIGALERT AND HAVE ALL UTILITIES MARKED BEFORE DIGGING.
PLAN PREPARED BY:
VAN DELL AND ASSOCIATES, INC.
CIVIL ENGINEERS
SURVEYORS LAND PLANNERS DRAWN BY:
17801 CARTWRIGHT ROAD TWF{/RM
IRVINE CA 92614 (949) 474-1400 DESIGNED BY:
L DM 11.E SUPERVISION OF: i DJH
DONALD R. GORDON R.C.E. 24725
CHECKED BY:
���� a� Is-lipr
DRG
DATE
CITY OF FONTANA, CALIFORNIA
SEWER IMPROVEMENT PLANS
SOUTHRIDGE VILLAGE
TRACT 17021 LOT 1 TO 19
TITS, #- SHEET
7 -
DATE:
F-
0
Ln
rrj
ml
Ln
0
0
N
Q0
0
cn�
m
LO
0
L IM
00
Co
cn
N
0
I-
F-
cn
C�
z
Li
Ln
0
WE
610
10
SCALE: /
AS SHOWN --
DATE: U
06-06-05
0
DRAWING NO.:1 0-
3378 3 x