Loading...
HomeMy WebLinkAbout3853-11. ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA STANDARD PLANS, THE CONTRACT PROVISIONS AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION ("GREEN BOOK"). ALL REFERENCE SPECIFICATIONS AND STANDARDS SHALL BE THE LATEST EDITION UNLESS OTHERWISE NOTED. 2. WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CAN NOT BE RESOLVED BY REFERENCE TO PRECEDENCE PROVISIONS IN THE "GREEN BOOK", THE CONTRACTOR SHALL IMMEDIATELY REPORT SAID CONFLICT TO THE CITY ENGINEER FOR RESOLUTION. 3. ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER. 4. ADVANCE CONSTRUCTION SIGNING INDICATING DURATION OF PROJECT SHALL BE IN PLACE ONE WEEK PRIOR TO IMPLEMENTING DETOURS. 5. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVELOPMENT DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC RIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL (909) 350-7610. 6. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND PROCEDURES DESCRIBED IN THE STATE OF CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST NON -METRIC EDITION UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER. 7. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS OR OTHER TRAFFIC CONTROL DEVICES AT ALL TIMES. 8. THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK FOR TRENCHES 5 FEET OR GREATER IN DEPTH FROM THE CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY. 9. THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE GUARDED BY SHORING, SLOPING OF THE GROUND OR OTHER APPROVED MEANS PURSUANT TO THE REQUIREMENTS OF THE DIVISION OF INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA. TRENCHES LESS THAN FIVE (5) FEET SHALL ALSO BE GUARDED WHEN THE POTENTIAL EXISTS FOR GROUND MOVEMENT. 10. NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT OF WAY WITHOUT OBTAINING A SEPARATE PERMIT FOR THAT PURPOSE. 11. THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION, HOWEVER, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE, IN THE FIELD, THE TRUE LOCATION AND ELEVATION OF ANY EXISTING UTILITIES, AND TO EXERCISE PROPER PRECAUTION TO AVOID DAMAGE THERETO. THE CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT AT 1-800-227-2600 TWO WORKING DAYS BEFORE EXCAVATION. 12. THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES INCLUDING, BUT NOT LIMITED TO, GAS, TELEPHONE, ELECTRIC, CABLE TELEVISION, LANDSCAPING, LANDSCAPE, IRRIGATION, DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND CALTRAN$. ALL UTILITY COMPANIES SHALL BE GIVEN TWO WORKING DAYS NOTICE PRIOR TO WORK AROUND THEIR FACILITIES. 13. THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES WITHOUT APPROPRIATE AGENCY AUTHORIZATION. CONTRACTOR SHALL COORDINATE WITH THEAPPROPRIATE WATER COMPANY FOR VALVE OPERATION AND WATER REQUIREMENTS. 14. STATIONING REFERS TO THE CENTERLINE OF STORM DRAIN EXCEPT WHERE OTHERWISE NOTED. 15. ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE CONTRACTOR TO CONSTRUCT THE WORK TO THE PLAN GRADES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL STAKING DURING CONSTRUCTION. 16. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT TIES OR BENCH MARKS WITHOUT PRIOR NOTIFICATION TO THE CITY ENGINEER. 17. REMOVAL AND REPLACEMENT OF EXISTING SURVEYCONTROL, INCLUDING SURVEY MONUMENTS, MONUMENT TIES AND BENCH MARKS, SHALL BE DONE BY A REGISTERED CIVIL ENGINEER OR LICENSED LAND SURVEYOR. SURVEY MONUMENTS THAT WILL BE DESTROYED AS A RESULT OF THIS CONSTRUCTION SHALL BE REPLACED. THE CONTRACTOR SHALL NOTIFY THE ENGINEER ONE WEEK PRIOR TO CONSTRUCTION SO THAT TIES TO MONUMENTS CAN BE ESTABLISHED FOR LATER REPLACEMENT OF THE MONUMENT. 18. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES. A MINIMUM 12 FOOT LANE SHALL BE MAINTAINED AT ALL TIMES IN THE CONSTRUCTION AREA FOR RESIDENTS AND EMERGENCY VEHICLES. 19. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL, INCLUDING ADEQUATE WATERING, AT ALL TIMES. 20. THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR DEBRIS TO BE DEPOSITED ONTO PUBLIC OR PRIVATE PROPERTY ADJACENT TO THE RIGHT OF WAY DURING CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL. 21. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR. 3 22.A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION. FAILURE TO -n OBTAIN THE REQUIRED DENSITY SHALL REQUIRE RE -WORKING OF THAT PORTION OF THE V) WORK UNTIL THE SPECIFIED DENSITY IS OBTAINED. 0 23. CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING i Li STREET IMPROVEMENTS. UPON INSPECTION OF THE SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY NON-ERODEABLE SWALES ENTERING OR LEAVING IMPROVEMENTS. � 24. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH v IL TO MATCH EXISTING CONCRETE. 0 -6, 0 (n BASIS OF BEARINGS: LEGAL DESCRIPTION: TACT 16290--J2 GRAPHIC SCALE 150 0 75 150 300 1 " = 150' tSTORM DRAIN IMPROVEMENT PLANS TJ-? , a fo`!T lf 10�1 SHEET INDEX oe- 1 2 3 4 5 6 7 8 9 10 11 (909) 875-1804 BEGINNIN G OF CURVE CONSTRUCTION RIALTO, CA 92377 ESTIMATE BOTTOM 12 CONNECTIONS TO EXISTING FACILITIES DOES NOT IMPLY CORRECTNESS OF CENTERLINE BOT. ELEVATIONS OR LOCATIONS SHOWN ON THE PLANS. SEWER CITY OF FONTANA 1 "=150' 25. NO OPEN TRENCH SHALL BE ALLOWED AT THE END OF THE DAY WITHOUT PRIOR UTILITY PURVEYORS APPROVAL OT HE CITY ENGINEER. 1:1 SLOPE OR FLATTER OR ADEQUATE SHORING 1 TITLE SHEET/VICINITY - MAP/INDEX MAP. 2 LINE "C-7" PLAN AND PROFILE. 3 LAT. "A", LAT. "B", CP "B-1 " CP "B-2", CP "B-3" PLAN AND PROFILE. 4 CP "C- 7A ", CP "C -7B ", CP 'OC -7C')) CP "'C -7D". 5-11 STANDARD DETAILS. TOP OF STRUCTURAL PAVEMENT SUBGRADE N 90% COMPACTED NATIVE_ BACKFILL 6" MAX SIZE 6" MIN. _ 8" MIN. NP/N, STORM DRAIN PIPE GRANULAR BEDDING FROM SELECTED z m TRENCH SIDE MATERIAL FOR PIPE 10' o OR GREATER IN DEPTH USE 112 w CRUSHED STONE BEDDING °Q NOTES: 1. TRENCH WIDTH SHALL BE CONTROLLED TO TOP OF PIPE ZONE 2. TRENCH DEPTHS OF GREATER THAN 5' SHALL HAVE ADEQUATE SHORING 3. CLASS 11 AGGREGATE BASE ALL TRENCHES LESS THAN 100 FEET IN LENGTH 3 " MAX. SIZE NATIVE SOIL COMPACTED 95% GRANULAR BEDDING FROM SELECTED TRENCH SIDE MATERIAL (1 " MAX SIZE) NOTES: COMPACTION SHALL BE 90% IN ALL ZONES UNLESS OTHERWISE SPECIFIED. TRENCH STABILITY SHALL CONFORM TO CAL -OSHA REQUIREMENTS TRENCH DETAIL N.rs. 1 -0 99;Q1 I 26. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL EXPOSE EXISTING FACILITIES, WATER WEST VALLEY WATER DISTRICT ATTENTION: LUN TSAI APWA AND VERIFY ELEVATION AND LOCATION OF CONNECTIONS. CITY OF APPROVAL OF 855 W. BASELINE TELEPHONE: (909) 875-1804 BEGINNIN G OF CURVE CONSTRUCTION RIALTO, CA 92377 ESTIMATE BOTTOM BC CONNECTIONS TO EXISTING FACILITIES DOES NOT IMPLY CORRECTNESS OF CENTERLINE BOT. ELEVATIONS OR LOCATIONS SHOWN ON THE PLANS. SEWER CITY OF FONTANA ATTENTION: BRYAN WREN CIL 27. IF EXISTING UTILITIES OR ANY OTHER FACILITIES CONFLICT WITH THE PROPOSED 18" RCP (D -LOAD PER PROFILE) 8353 SIERRA AVE. TELEPHONE: (909) 350-6632 C.L. IMPROVEMENTS, THE CONTRACTOR SHALL NOT NOTIFY THE ENGINEER AND ALL FONTANA, CA 92335 CUBIC FEET PER SECOND � CFS AFFECTED AGENCIES IMMEDIATELY. ELECTRIC SOUTHERN CALIFORNIA EDISON COMPANY ATTENTION: JEFF BURT DIP 28. NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE CONSTRUCT 800 W. CIENEGA AVENUE TELEPHONE: (909) 592-3737 ELEV. BEEN PLACED, INSPECTED AND APPROVED. SAN DIMAS, CA 91773 EC O CONSTRUCT 36" RCP (D -LOAD PER PROFILE) 212 L. F. EXIST. 29. ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR GAS SOUTHERN CALIFORNIA GAS COMPANY ATTENTION: STEVE ROBLES GB TO PLACEMENT. O 16231 VALLEY BOULEVARD TELEPHONE: (909) 428-8407 450.00 30. APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT FONTANA, CA 92335 450.00 PRIOR TO PLACEMENT. O CONSTRUCT MANHOLE PER APWA STD. DWG. N0. 322-1 3 INT. 31. ALL MANHOLES, CLEANOUT FRAMES,COVERS AND VALVE BOXES SHALL BE RAISED TO TELEPHONE VERIZON ATTENTION: FRANK ANGUSTAIN INV. FINISHING GRADE BY THE PAVING CONTRACTOR UPON COMPLETION OF PAVING. O 16071 MOJAVE DRIVE, BLDG. B TELEPHONE: (760) 245-0330 M.H. P.E. 32. UPON COMPLETION OF CON STRUCTI ON, CONTRACTOR SHALL RESTORE ALL SIGNING, VICTORVILLE, CA 92392 PRC STRIPING, BARRICADES,AND OTHER TRAFFIC CONTROL DEVICES TO THE SATISFACTION O9 CONSTRUCT LOCAL DEPRESSIONS AT CATCH BASIN CASE A PER APWA STD. PLAN 313-1. 8 PVC OF THE CITY TRAFFIC ENGINEER. CABLE ADELPHIA COMMUNICATIONS ATTENTION: LEWIS MCDONALD P/L 33. AS BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER � p 1500 S. AUTOCENTER DRIVE TELEPHONE. (909) 975-3343 PROP. OF RECORD,WHO SHALL PROVIDE RECORD DRAWINGS TO THE CITY ENGINEER. CONSTRUCT ONTARIO, CA 91761 5 EA. PUBLIC UTILITY EASEMENT PUE CONSTRUCT JUNCTION STRUCTURE PER APWA STD. PLAN 331-2 1 EA. REINFORCED CONCRETE PIPE RCP 34 MINIMUM D -LOAD FOR ALL RCP IS 1350-D. -- RIGHT OF WAY R/W '0 BEARINGS ARE BASED ON THE WESTERLY LINE OF BEING A SUBDIVISION OF A PORTION OF THE SOUTHEAST 1/4 OF SECTION 14, AND A PORTION OF THE .v THE NORTHEAST QUARTER OF SECTION 23, TOWNSHIP NORTHEAST 1/4 OF SECTION 23, BOTH OF TOWNSHIP 1 NORTH, RANGE 6 WEST, SAN BERNARDINO 1 NORTH, RANGE 6 WEST, SAN BERNARDINO MERIDIAN, MERIDIAN, COUNTY OF SAN BERNARDINO. c: AS SHOWN ON AMENDING MAP OF TRACT NO. 13750, i E FILED IN BOOK 250 OF MAPS, AT PAGES 48 THROUGH' rn 66, INCLUSIVE, IN THE OFFICE OF THE COUNTY rn RECORDER OF SAN BERNARDINO COUNTY, BEING NT , ' a BENCH MARK: 1-110 DESCRIBED BY METROPOLITAN WATER DISTRICT SO. CALIFORNIA 1992 RANCHO CUCAMONGA, NEAR THE i Q INTERSECTION OF SUMMIT AVE. AND CHERRY AVE. AT THE o cn SOUTHWEST CORNER OF CHERRY AVE. AND SUMMIT AVE. 101 FEET WEST OF THE CENTERLINE OF CHERRY AVE. AND 37 EFEET SOUTH OF THE CENTERLINE OF SUMMIT AVE. SET FLUSH Z a ON THE NORTHWEST CORNER OF A 10 FOOT WIDE c'0 CATCHBASIN 0.8 FOOT SOUTH OF CURB FACE. A STANDARD v ; MWDSC 3 INCH BRASS DISK STAMPED "33A 1992". o NAVD 88 - 1508.56 (FEET) AAA AAA AA TOLL FREE 1-800-227-2600 A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT REV. I REVISION DESCRIPTION 26COf2p DK/AW//,/(9 OWNER/DEVELOPER Centex Homes 1265 Corona Pointe Court Corona, CA 92879 Ph: (951) 279-3000 Fax: (951) 279-2100 DATE I ENGR. I CITY I DATE //11710,5 SOIL ENGINEER ALBUS-KEEFE and ASSOC., INC. 1011 N. ARMANDO STREET ANAHEIM, CA 92806 Ph: (714) 630-1626 Fax: (714) 630-1916 QpoFt / ,� s �p TORq y/ STD. sra. ��.o6 68 :0sr.sc N Q �r EXP. 30 * W Q,. WS OF CAL�� SEAL -ENGINEER SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT QROFESS/pNq� COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL F N y� SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, THE w ARIC M. TORREYSON m o. 66068 CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO BRING NExp. 06-30-06 THEM INTO CONFORMANCE WITH CONDITIONS AND STANDARDS IN '9�F clvt� OF C EFFECT. CHERRY AVENUE SUMMIT ,I AVENUE ffAk ml I:* :[l SITE LOCATION COYOTE CANYON ROAD r �P CD ROAD CREEK - DUNCAN CANYON ROAD VICINITY MAP N. T. S. CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, CONSTRUCTION CONTRACTOR WILL BE REQUIRED TO ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THE PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY, THAT THIS REQUIREMENT SHALL BE MADE TO APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS, AND CONSTRUCTION CONTRACTOR FURTHER AGREES TO DEFEND, INDEMNIFY AND HOLD DESIGN PROFESSIONAL HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF DESIGN PROFESSIONAL. ENGINEER'S NOTICE TO CONTRACTORS THE EXISTENCE AND LOCATION OF ANY UNDERGROUND OR OVERHEAD UTILITIES OR STRUCTURES SHOWN ON THESE PLANS ARE APPROXIMATE. THE ENGINEER AS,$LIMES ......:.... NO LIABILITY AS TO THE EXACT LOCATION OF SAID LINES NOR FOR UTILITIES' OR IRRIGATION LINES WHOSE LOCATION ARE NOT SHOWN. THE CONTRACTOR SHALL BE RESPONSIBLE FOR NOTIFYING ALL UTILITY AND IRRIGATION COMPAIV05 PRIOR TO WORK TO ACCURATELY IDENTIFY THESE LOCATIONS, WHETHER OR NOT SHOWN HEREON, AND IS RESPONSIBLE FOR ANY DAMAGE OR PROTECTION OF THESE LINES. PHASED UTILITY RELOCATIONS MAY BE NECESSARY AND SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO CLOSELY COORDINATE HIS ACTIVITIES WITH THOSE OF ALL UTILITY COMPANIES. THE CONTRACTOR SHALL CALL IN A LOCATION REQUEST TO UNDERGROUND SERVICE ALERT (U.S.A.) PHONE 1-800-227-2600 TWO (2) WORKING DAYS PRIOR TO DIGGING. NO CONSTRUCTION PERMIT ISSUED BY PUBLIC WORKS DEPARTMENT SHALL BE VALID INVOLVING UNDERGROUND FACILITIES UNLESS THE APPLICANT HAS AN INQUIRY IDENTIFICATION NUMBER ISSUED BY U. S.A. THE ESTIMATED QUANTITY FOR EACH SPECIFIC ITEM OF THE WORK DESIGNATED ON THE PLANS SHALL BE CONSIDERED AS APPROXIMATE ONLY AND NO GUARANTEE IS MADE THAT THE QUANTITIES WHICH CAN BE DETERMINED BY COMPUTATIONS, BASED ON THE DETAILS AND DIMENSIONS SHOWN ON THE PLANS, WILL EQUAL THE ESTIMATED QUANTITIES. THE ESTIMATE OF QUANTITIES IS PROVIDED BY THE ENGINEER ONLY FOR THE CONVENIENCE OF THE OWNER, THE CONTRACTOR SHALL MAKE HIS OWN DETERMINATION AND BE RESPONSIBLE FOR HIS OWN CONSTRUCTION QUANTITIES BEFORE SUBMITTING A BID. ANY ITEM OF WORK, OR PORTION THEREOF, REQUIRED BY THESE PLANS WHICH IS NOT SPECIFICALLY LISTED IN THE ESTIMATE OF QUANTITIES SHALL BE CONSIDERED AS-. AMERICAN PUBLIC WORKS ...,.,....,..".�� INCLUDED IN THE OTHER ITEMS OF WORK. ASSOCIATION BEGINNIN G OF CURVE CONSTRUCTION NOTES ESTIMATE BOTTOM CENTERLINE CENTERLINE O CONSTRUCT 18" RCP (D -LOAD PER PROFILE) 471 LF. CENTERLINE CUBIC FEET PER SECOND 2O CONSTRUCT 24" RCP (D -LOAD PER PROFILE) 226 L. F. DUCTILE IRON PIPE O CONSTRUCT 30" RCP (D -LOAD PER PROFILE) 123 L. F. ELEVATION END OF CURVE O CONSTRUCT 36" RCP (D -LOAD PER PROFILE) 212 L. F. EXISTING GRADE BREAK O CONSTRUCT 48" RCP (D -LOAD PER PROFILE) 177 L.F. INDICATES EXISTING CONDITION INDICATES PROPOSED CONDITION O CONSTRUCT MANHOLE PER APWA STD. DWG. N0. 322-1 3 EA. INTERSECTION INVERT O CONSTRUCT CATCH BASIN PER APWA STD. PLAN 300-2. 11 EA. MANHOLE PAD ELEVATION O9 CONSTRUCT LOCAL DEPRESSIONS AT CATCH BASIN CASE A PER APWA STD. PLAN 313-1. 8 EA. POINT OF REVERSE CURVATURE POLY VINYL CHLORIDE � p CONSTRUCT CONCRETE FLARED END SECTION PER CALTRANS STD. PLAN D94B. 1 EA. PROPER LINE PROPOSED 1 1 CONSTRUCT MONOLITHIC CATCH BASIN CONNECTION PER APWA STD. PLAN 308-1. 5 EA. PUBLIC UTILITY EASEMENT 12 CONSTRUCT JUNCTION STRUCTURE PER APWA STD. PLAN 331-2 1 EA. REINFORCED CONCRETE PIPE RIGHT OF WAY 13 CONSTRUCT MANHOLE PER APWA STD. PLAN 321-1. 2 EA. SEWER LINE STANDARD 14 CONSTRUCT TRANSITION STRUCTURE PER APWA STD. PLAN 340-1. 1 EA. STATION STORM DRAIN LINE 15 CONSTRUCT CONCRETE COLLAR PER APWA STD. PLAN 380-3. 2 EA. STREET STATION 16 CONSTRUCT 12° CONDUCTOR TUBE PER WVWD STD. W-23. 11 EA. TOP OF CURB WATER LINE 17 CONSTRUCT 1/4 TON RIP -RAP (T=3.0') WITH GRAVEL OVER MIRAFI BLANKED OR EQUAL. 2.1 CY. WATER SURFACE 18 CONSTRUCT LOCAL DEPRESSIONS AT CATCH BASIN CASE B PER APW,4 STD. PLAN 313-1. 3 EA. AEl,lCASC I E! -,1 I! -i E E R I 1-Q 7J DRAWN BY: 937 SOUTH VIA LATA, SUITE 500 COLTON, CA 92324 O.S. PH. (909) 783-0101 FAX (909) 783-0108 DESIGNED BY: PREPARE. ARIC TORREYSON R.C.E. N0. 66068 EXP. E: 6-3 6 CHECKED BY.. DATE: ,� A.M.T. CITY OF FONTANA, CALIFORNIA COYOTE CANYON TRACT 16290-1 SCALE: STOR DRAIN IMPROVEMENTS AS SHOWN �` DATE: TITLE SHEET -,JUNE 2005 P VED DRAWING NO.: t 3853 11 CITY ENGINEER R.C.E. 51152 DATE ' r