Loading...
HomeMy WebLinkAbout3820-2 1 11 4' I L 30' 30' 1 I 11' 11'. I "STOP AHEAD" LEGEND I EXIST. STRIPIN ..zEXIST. RIGHT OF WAY fT /L CYPRESS AVE. TO REMAIN PROPOSED EDGE OF PAVEMENT _ _ —I JIPEDEDGEMENT T. W3-144 _ --- - - - - - - - I o 10 00 ® 12+00 13+00 J 4 14+00 15+00 16+00 17+00 4 18+00 Q 19+00 20+00 ND N 21+00 W _ --I E I f I i I 1 I 1 8 — H H__— 1 1 ---I + J N 11+00 100' 1 [ 100' 1 I N-0 - e} M EXIST- 100' - Q r7 in0 B.17.1.---i "45" LEGEND I III J ' W IIIIIIIIIIIIIIIIIIIIIr —1- ED- 1111- 1— -i I RIGHT OF WAY CU'B AND GUTTER © �� RIGHT IF WAY CURB AND GUTTER Q a) _ VI � R2-1(45) ►, Q Q ,111.11111.1111"mma 76 / I I 1 © I 30' 6' rI 1 I I SANTA ANA AVENUE CORIANDER PLACE SEE SHEET 3 SEE DETAIL SHEET 1 CYPRESS AVENUE I I C/L CYPRESS AVE. oi aD 0 z EXIST. RIGHT OF WAY � _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ °' _ EXISTING CURB AND GUTTER _ _ _ IL EXIST. EDGE OF PAVEMENT _ _ _ EL N t M Q 0 � 22+00 0 23+00 24+00 25+00 26+00 27+00 (1--i) w 28+00 N 29+00 30+00 31+00 32+00 + OX— I- - _422+0-0 - 4 - •I- H - --I - -I - I-- - 1 ) - I - _f_____ _ I - I - I - H H N Cr I 100' -I 100' rn ID r4) z 0 I ___ -- • - 0 - = co , r ©~- , •• _•` - - - - - - 1 - - - 0,./ 25' PAVEMENT TRANSITION \ 0 W , 2 1 ♦` TYPE F EXIST. RIGHT OF WAY WI W CURB ND GUTTER 1 CURB AND GUTTER RIGHT OF WAY I s .� 4 � 0 I I , © I c�) I iI I � I \ I I , , I ALISO DRIVE CONSTRUCTION SEE DETAIL SHEET 1 SIGNING AND STRIPING GENERAL NOTES S UCTION NOTES: 1. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVELOPMENT 01 INSTALL STREET NAME SIGN ® APPLY THERMOPLASTIC TYPE IV TURN ARROW (R7) DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC O APPLY DOUBLE YELLOW CENTERLINE STRIPING PER MUTCD DETAILRIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL (909) 350-7610. 22. ® INSTALL "RIGHT LANE MUST TURN RIGHT" SIGN PER MUTCD CODE R3-7 2. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS, DETAILS, 03 APPLY 12" WHITE THERMOPLASTIC LIMIT LINE © APPLY THERMOPLASTIC LANE DROP MARKINGS PER MUTCD DETAIL 37B CYPRESS AVENUE DIMENSIONS AND PROCEDURES DESCRIBED IN THE STATE OF CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST EDITION. ® APPLY THERMOPLASTIC STOP LEGEND 0 INSTALL "RIGHT LANE TURNS RIGHT AHEAD" SIGN PER MUTCD CODE 3. CONTACT TRAFFIC ENGINEERING PROJECT MANAGER AT (909) 350-7610 TWO WORKING DAYS PRIOR TO 05 INSTALL R1-1 SIGN AND POST AS SHOWN W73A(CA) THE REMOVAL OF TRAFFIC CONTROL DEVICES OR EQUIPMENT. STOP SIGNS SHALL ONLY BE REMOVED BY CITY PERSONNEL. 0 APPLY THERMOPLASTIC CHANNELIZING LINE PER MUTCD DETAIL 38 4. ALL WORK, MATERIALS AND EQUIPMENT SHALL CONFORM TO THE 2003 MANUAL ON UNIFORM TRAFFIC 07 APPLY CENTERLINE STRIPE PER MUTCD DETAIL 6 CONTROL DEVICES (MUTCD) AND THE MUTCD 2003 CALIFORNIA SUPPLEMENT. it 0 1 ® APPLY CENTERLINE STRIPE PER MUTCD DETAIL 2 5. 2 WORKING DAYS NOTICE SHALL BE GIVEN TO THE CITY TRAFFIC ENGINEER (909) 350-7610 FOR APPROVAL OF CONTROL POINTS OR "CAT TRACKING" PRIOR TO APPLICATION OF PAVEMENT STRIPING. o 09 APPLY EDGE STRIPE PER MUTCD DETAIL 27B ✓ 6. TRAFFIC SIGN SIZE SHALL BE FOR CONVENTIONAL ROADWAYS UNLESS OTHERWISE SHOWN ON PLANS. 'P ® ISIALL_25MPH SPEED'LIMIT SIGN PER MUTCD, CODE R2-1(25) 0 7. ALL SIGNS SHALL BE MOUNTED ON GALVANIZED STEEL POSTS, UNLESS OTHERWISE SHOWN ON THE '' PLANS, PER CITY STANDARD DETAIL NO. 4008 11 INSTALL 45MPH SPEED LIMIT SIGN PER MUTCD CODE R2-1(45) 8. STENCILS USED FOR PAVEMENT MARKINGS SHALL MATCH CITY OF FONTANA STANDARD STENCILS. (,i INSTALL THERMOPLASTIC "45" PAVEMENT LEGEND 0 �pF z.._.‘„?'". ._, I 9. ALL STRIPING AND PAVEMENT MARKINGS SHALL BE ALKYD THERMOPLASTIC UNLESS OTHERWISE NOTED. N 0 INSTALL THERMOPLASTIC "STOP AHEAD" PAVEMENT LEGEND 4 �O Y 1%t� '�� 3 tvQ r 10. CROSSWALKS SHALL HAVE 10' BETWEEN THE CENTERLINE OF THE 12" STRIPE UNLESS OTHERWISE 4 i 0 INSTALL TYPE F DELINEATORS AT 25' SPACING, THROUGHOUT TRANSITIONfEl q l sus SHOWN ON PLANS. PER CITY STANDARD DETAIL 1006. W a �, O 11. AS- BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO * * GRAPHIC SCALE SHALL PROVIDE DRAWINGS AND ELECTRONIC CAD FILES. TO THE CITY TRAFFIC ENGINEER. CNS N �40 0 20 40 80 160 42,„ CN ``FpQ��li 12. ALL CONFLICTING STRIPING, MARKINGS TO BE REMOVED, SHALL BE BY SANDBLASTING. N 0 0 13. BLUE DOT MARKERS (BLUE R.R.P.M.) ARE TO BE INSTALLED AT ALL FIRE HYDRANT LOCATIONS PER ii SCALE 1" 40' CITY STANDARD PLAN. o RECORD DRAWING , , ei io) 1 ( _Ti Axg PENCO En eerie Inc. CITY OF FONTANA, CALIFORNIA jci wrii SHOULD CONSTRUCTION OF THE REQUIRED g M '"�� SIGNING AND STRIPING PLAN ° IMPROVEMENTS NOT COMMENCE WITHIN TWO ���°s �;� 'J Civil Engineering ill ��� ,,,I1fr Irvine • Inland Empire N *441 - YEARS OF THE DATE OF APPROVAL SHOWN HEREON i''of �N Planning 2191 5th Street, Suite 211 • Norco, California 92860 DRAW" BY: SCALE: o DI �L watKING AND CARRIED FORTH IN A DILIGENT MANNER, THE * Exp°12 311--07 * Surveying Phone (951) 736-2040 • Fox (951) 736-5292AS SHOWN BEFORE oIlyTWODAYS BEFORECITY ENGINEER MAY RE UIRE REVISIONS TO THE / DESIGNED BY: Ls DATEYou ac 1rjYOU DIG Q � ���,� �, CYPRESS AVENUE c NOV, 2005 AIL _e0p_�7_2000 RECORD DRAWING 2/2 AB PLANS TO BRING THEM INTO CONFORMANCE WITH '° CAI.'E G CHECK D BY: APPROVED BY: DRAWING NO.: 2 AP � BY UNDERGROUND SERVICEALERT ���lM STANDARDS IN EFFECT. 000GLO N. CROUSE R.C.E. No. 23796 EXP. 12/31/07 DATE ilishee V. RENSION DESCRIPTION DATE ENGR. CITY DATE CITY TRAFFIC ENGINEER .C.E. 68 9 DATE 3820