HomeMy WebLinkAbout4334-1GENERAL NOTES ACCORDANCE WITH THESE PLANS THE CITY OF FONTANA STANDARD PLANS 1. ALL WORK SHALL BE IN AC , THE CONTRACT PROVISIONS AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION ("GREEN BOOK'). ALL REFERENCE SPECIFICATIONS AND STANDARDS SHALL BE THE LATEST EDITION UNLESS OTHERWISE NOTED. 2. WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CAN NOT BE RESOLVED BY REFERENCE TO PRECEDENCE PROVISIONS IN THE "GREEN BOOK". THE CONTRACTOR SHALL IMMEDIATELY REPORT SAID CONFLICT TO THE CITY ENGINEER FOR RESOLUTION. J. ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER. 4. ADVANCE CONSTRUCTION SIGNING INDICATING DURATION OF PROJECT SHALL BE IN PLACE ONE WEEK PRIOR TO IMPLEMENTING DETOURS. 5. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVELOPMENT DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK, INSPECTION COORDINATION SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC RIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL (909) 350-7610. 6. THE CONTRACTOR SHALL 'CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND PROCEDURES DESCRIBED IN THE STATE OF CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST NON -METRIC EDITION UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER. 7. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS OR OTHER TRAFFIC CONTROL DEVICES AT ALL TIMES. 8. THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK FOR TRENCHES 5 FEET OR GREATER IN DEPTH FROM THE CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY. 9. THE WALLS,AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE GUARDED BY SHORING, SLOPING OF THE GROUND OR OTHER APPROVED MEANS PURSUANT TO THE REQUIREMENTS OF THE DIVISION OF INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA. TRENCHES LESS THAN FIVE (5) FEET SHALL ALSO BE GUARDED WHEN THE POTENTIAL EXISTS FOR GROUND MOVEMENT. 10. NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT OF WAY WITHOUT OBTAINING A SEPARATE PERMIT FOR THAT PURPOSE. 11. THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION, HOWEVER, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE, IN THE FIELD, THE TRUE LOCATION AND ELEVATION OF ANY EXISTING UTILITIES, AND TO EXERCISE PROPER PRECAUTION TO AVOID DAMAGE THERETO. THE CONTRACTOR SHALL CONTRACT UNDERGROUND SERVICE ALERT AT 1-800-227-2600 TWO WORKING DAYS BEFORE EXCAVATION. 12. THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES INCLUDING, BUT NOT LIMITED TO GAS, TELEPHONE, ELECTRIC, CABLE TELEVISION, LANDSCAPING, LANDSCAPE IRRIGATION, DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND CALTRANS, ALL UTILITY COMPANIES SHALL BE GIVEN TWO WORKING DAYS NOTICE PRIOR TO WORK AROUND THEIR FACILITIES. 13. THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES WITHOUT APPROPRIATE AGENCY AUTHORIZATION. CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE WATER COMPANY FOR VALVE OPERATION AND WATER REQUIREMENTS. 14. STATIONING REFERS TO THE CENTERLINE OF STORM DRAIN EXCEPT WHERE OTHERWISE NOTED. 15. ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENG/NEER TO ENABLE THE CONTRACTOR TO CONSTRUCT THE WORK TO THE PLAN GRADES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL STAKING DURING CONSTRUCTION. 16. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT TIES OR BENCH MARKS WITHOUT PRIOR NOTIFICATION TO THE CITY ENGINEER. 17. REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING SURVEY MONUMENTS, MONUMENT TIES AND BENCH MARKS, SHALL BE DONE BY A REGISTERED CIVIL ENGINEER OR LICENSED LAND SURVEYOR. SURVEY MONUMENTS THAT WILL BE DESTROYED AS A RESULT OF THIS CONSTRUCTION SHALL BE REPLACED. THE CONTRACTOR SHALL NOTIFY THE ENGINEER ONE WEEK PRIOR TO CONSTRUCTION SO THAT TIES TO MONUMENTS CAN BE ESTABLISHED FOR LATER REPLACEMENT OF THE MONUMENT 18. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES. A MINIMUM , 12 FOOT LANE SHALL BE MAINTAINED AT ALL TIMES IN THE CONSTRUCTION AREA FOR RES/DENTS AND EMERGENCY VEHICLES. 19. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL, INCLUDING ADEQUATE WATERING, AT ALL TIMES. 20. THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR DEBRIS TO BE DEPOSITED ONTO PUBLIC OR PRIVATE PROPERTY ADJACENT TO THE RIGHT OF WAY DURING CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL. 21. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR. 22. A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION, FAILURE TO OBTAIN THE REQUIRED DENSITY SHALL REQUIRE RE -WORKING OF THAT PORTION OF THE WORK UNTIL THE SPECIFIED DENSITY IS OBTAINED. 23. CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING STREET IMPROVEMENTS UPON INSPECTION OF THE SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY NON-ERODEABLE SWALES ENTERING OR LEAVING IMPROVEMENTS. 24. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH TO MATCH EXISTING CONCRETE. 25. NO OPEN TRENCH SHALL BE ALLOWED AT THE END OF THE DAY WITHOUT PRIOR APPROVAL OF THE CITY ENG/NEER. 26. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL EXPOSE EXISTING FACILITIES, AND VERIFY ELEVATION AND LOCATION OF CONNECTIONS. CITY APPROVAL OF CONNECTIONS TO EXISTING FACILITIES DOES NOT IMPLY CORRECTNESS OF ELEVATIONS OR LOCATIONS SHOWN ON THE PLANS 27. IF EXISTING UTILITIES OR ANY OTHER FACILITIES CONFLICT WITH THE PROPOSED IMPROVEMENTS, THE CONTRACTOR SHALL NOTIFY THE ENGINEER AND ALL AFFECTED AGENCIES IMMEDIATELY. 28 NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN PLACED, INSPECTED AND APPROVED. 29. ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR TO PAVING OR STREETS 30. APPROVED SOILS STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT PRIOR TO PLACEMENT. 31. ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED TO FINISHED GRADE BY THE PAVING CONTRACTOR UPON COMPLETION OF PAVING. 32. UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING, STRIPING, BARRICADES, AND OTHER TRAFFIC CONTROL DEVICES TO THE SATISFACTION OF THE CITY TRAFFIC ENGINEER. 33. AS-BULIT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO SHALL PROVIDE RECORD DRAWINGS TO THE CITY ENGINEER. 34. MINIMUM D -LOAD FOR ALL RCP IS 1350. 35. THE CONCRETE COATING ON THE INSIDE OF ALL REINFORCED CONCRETE PIPE MUST BE INCREASED TO PROVIDE A MINIMUM OF 1-1/2 INCHES OVER THE REINFORCING WHEN THE DESIGN VELOCITIES EXCEED 20 FEET PER SECOND. THE CONCRETE DESIGN STRENGTH IN THESE REACHES SHALL BE FC=5000 PSI FOR VELOCITIES EXCEEDING 20 FEET PER SECOND AND FC=6000 PSI FOR VELOCITIES EXCEEDING 30 FEET PER SECOND. 0 00 II I "TV r, iWA,, v. I&A - .. 1� III s NS prm%LA R) I S/u 3'. ', .} i e r �. a .. • z, .+' I .,.-... SIERRA ... i 1765"m4 _i PRIVATE ENGINEER'S NOTICE TO CONTRACTORS THE EXISTENCE AND LOCA 77ON OF ANY UNDERGROUND U77LI77ES OR STRUCTURES SHOWN ON THESE PLANS ARE OBTAINED BY A SEARCH OF AVAILABLE RECORDS; TO 7HE BEST OF OUR KNOWLEDGE, THERE ARE NO EXIS77NG U77LI77ES EXCEPT - THOSE SHOWN ON ]HESE PLANS THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAURONARY MEASURES TO PROTECT THE URLITY LINES SHOWN ON ]HESE DRAWINGS THE CONTRACTOR FURTHER ASSUMES ALL LIABILITY AND RESPON- SIBILITY FOR 7HE U77LITY PIPES, CONDUITS OR STRUCTURES SHOWN OR NOT SHOWN ON ]NESE DRAWINGS. THE CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSI- BILITY FOR THE JOB S17F COND177ONS DURING THE COURSE OF CONS7RUC77ON OF THIS PROJECT; INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT 7HIS SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS; AND THAT THE CON7TZACTOR SHALL DEFEND, INDEMNIFY, AND HOLD 7HE OWNER AND THE ENGINEER HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNEC77ON WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEP77NG FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER OR THE ENGINEER. CON7RACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AND SHALL REPORT ALL DISCREPANCIES TO 7HE ENGINEER PRIOR TO THE COMMENCEMENT OF ANY WORK. IT 13 THE RESPONSIBILITY OF THE CONTRACTOR TO N077FY THE ENGINEER OF ANY DISCREPANCIES BEGINNING OF WORK MEANS ACCEPTANCE-OF-CQND177ONS CON7RACTOR SHALL COMPLY WITH ALL NP.D.E.S REQUIREMENTS CITY OF FONTANA UTILITY NOTIFICATION LIST CIT`/ OF FONTANA PACIFIC BELL CO. 8353 SIERRA AVENUE ATTN.- NORMA GU/LLOT FONTANA, CA 92335 1265 N. VAN BUREN STREET (909) 350-6632 SUITE 180 / ANAHEIM, CA 92807 QN (714) 666-5401 SO. CALIFORNIA GAS COMPANY COMCAST (CABLE TV) ATTV.• GREG GASPAR ATTN. JACK HAYES 1205 16231 VALLEY BLVD. DUPONT AVENUE ONTARIO, CA. 91761 FONTANA, CA. 92335 (909) 390-4738 428-811 E.G. EMERGENCIES• (800) 427-2200 uq EX. VERIZON SO. CALIFORNIA EDISON COMPANY AT N. STEVE HOCK 7951 REDWOOD AVE. 1400 E. PHILLIPS BLVD. FONTANA, CA. 92335 POMONA, CA. 91766 (909) 820-5598 - UNDERGROUND (909) 469-6327 (909) 875-5100 - TRANSMISSIONS (213) 637-12JJ - PIPELINES FONTANA WATER COMPANY (909) 357-6233 - DISTRIBUTION ATTIC MICHAEL J. McGRAW J 8440 NUEVO AVENUE Tse _ I CA 92335 (909) CRAWFORD CANYON MUTUALFONTANA, WATER CO. 822-823-2201 2201 FAX. • (909) ATTN. BASIL J. FABRIZIO 5046 (909) 463-9580 - WEST SAN BERNARDINO WATER CO. UNDERGROUND SERVICE ALERT ATTN. LON TSAI (800) 422-4 1JJ 855 W. BASELINE ROAD RIALTO, CA 92377 CONSTRUCTION NOTES lo- INSTALL 18" RCP, CLASS IV INSTALL 36" RCP, D -LOAD PER PLAN j)- CONST JUNCTION STRUCTURE PER CITY OF FONTANA STD. 3010 ® CONST. JUNCTION STRUCTURE PER CITY OF FONTANA STD. 3009 LAND OWNER/DEVELOPER: LEWIS RETAIL CENTERS 1156 N. MOUNTAIN AVENUE UPLAND, CA 91786 P.O. BOX 670 UPLAND, CA 91785 CONTACT- BRIAN GARCIA PHONE. (909) 949-6779 FAX.- (909) 949-6733 E-MAIL: BRIAN. GARCIAOLEWISOP. COM no. 336^633 7 txt� 1% 9/O QUANTITIES 32 L. F. 33 L. F. 1 EA. 3 EA. � N I I-1 11- B. C. B. V. C. 1:1 SLOPE OR FLATTER TOP OF CURB OR ADEQUATE SHORING BACK SIDEWALK W / Q Zo� Z V QN VER77CAL DEPTH 00 v c�"i�oo ct O \N Q END CURVE V.C. W LAJ �v � E.G. EDGE GRADE lo- INSTALL 18" RCP, CLASS IV INSTALL 36" RCP, D -LOAD PER PLAN j)- CONST JUNCTION STRUCTURE PER CITY OF FONTANA STD. 3010 ® CONST. JUNCTION STRUCTURE PER CITY OF FONTANA STD. 3009 LAND OWNER/DEVELOPER: LEWIS RETAIL CENTERS 1156 N. MOUNTAIN AVENUE UPLAND, CA 91786 P.O. BOX 670 UPLAND, CA 91785 CONTACT- BRIAN GARCIA PHONE. (909) 949-6779 FAX.- (909) 949-6733 E-MAIL: BRIAN. GARCIAOLEWISOP. COM no. 336^633 7 txt� 1% 9/O QUANTITIES 32 L. F. 33 L. F. 1 EA. 3 EA. � N I I-1 11- B. C. B. V. C. 1:1 SLOPE OR FLATTER TOP OF CURB OR ADEQUATE SHORING BACK SIDEWALK W / C.B. 90% COMPACTED BACKFILL VER77CAL DEPTH NATIVE CENTERLINE 6" MAX. SIZE GRANULAR BEDDING FROM END CURVE V.C. SELECTED TRENCH SIDE E. P. MATERIAL (1 MAX. SIZE). E.G. EDGE GRADE uq EX. N III _ 8 MAX. aINWAF IE0 REMOVAL III III= - MOR 1 F. S. FINISH SURFACE G. B. GRADE BREAK C - _ J w Tse _ I wNSt�rn T ' 1 ISI z m Q_�W l i - �f C Z - P.C.C. PORTLAND CEMENT I CONCRETE (R) III I � M (590.77) INDICATES EXISTING ELEVATION 0.6'D' HE STORM DRAIN -11F PIPE x-1300 --\ ¢ TRENCH SIDE MATERIAL FOR PIPE INDICATES PROPOSED CONTOUR 10' OR GREATER IN DEPTH USE c.> ' I� SIERRA LAKES PKWY <RA _LAKE PKWY a Im - _ i u SR -210 FREEWAY �' HIGHLAND AV _-_-HIGHLAND _AV 'w TDRPLY AV -------------- I I , I I THESE FEC.. DAuFI,^,S t? v E PJ F r�rn I�,j PART, Cid THE F' ^X14 OF INFORM ,IATIOPd 0+ Fr. 0 AND FURNI HED BY OTNERS. -FHE EPIGINEFR + tj• Ri: RESPONSI13LE FOri A?dY ERROS?S Oq OP1'7r3 1�l'HItMt! HAVE BEEN INCORPORATED INTO THE GOCUTAENT4 A, 13 A RESULT THEREOF Cl VIL ENGINEER: MADOLE AND ASSOCIATES, INC. 1455 AUTO CENTER DR., SUITE 200 ONTARIO, CA 91761 CONTACT- LEO PACIS PHONE.- (909) 937-9151 VICINITY MAP N.TS. TOP -OF STRUCTURAL PAVEMENT SUBGRADE .I 11-► I � N I I-1 11- B. C. B. V. C. 1:1 SLOPE OR FLATTER TOP OF CURB OR ADEQUATE SHORING BACK SIDEWALK W / C.B. 90% COMPACTED BACKFILL VER77CAL DEPTH NATIVE CENTERLINE 6" MAX. SIZE GRANULAR BEDDING FROM END CURVE V.C. SELECTED TRENCH SIDE E. P. MATERIAL (1 MAX. SIZE). E.G. EDGE GRADE 6" MIN. III = EX. N III _ 8 MAX. Lu z REMOVAL III III= - o F. S. FINISH SURFACE G. B. GRADE BREAK lil J w INV. III = ISI z m Q_�W 0. C. ON CENTER P.C.C. PORTLAND CEMENT CONCRETE (R) III m RIGHT OF WAY - (590.77) INDICATES EXISTING ELEVATION 0.6'D' HE STORM DRAIN -11F PIPE x-1300 --\ GRANULAR BEDDING FROM SELECTED TRENCH SIDE MATERIAL FOR PIPE INDICATES PROPOSED CONTOUR 10' OR GREATER IN DEPTH USE 1/2" CRUSHED STONE BEDDING. TRENCH DETAIL NOT TO SCALE NOTES: 1. TRENCH WIDTH SHALL BE CONTROLLED TO TOP OF PIPE ZONE. 2. TRENCH DEPTHS OF GREATER THAN 5' SHALL HAVE ADEQUATE SHORING. 3. CLASS II AGG.BASE ALL TRENCHES LESS THAN 100' IN LENGTH. N I ED�S�4 , -OC8S8'm �6-3o� r/1 r1 /A 4. COMPACTION SHALL BE 90% IN ALL ZONES UNLESS OTHERWISE SPECIFIED. TRENCH STABILITY SHALL CONFORM TO CAL -OSHA REQUIREMENTS. A. C. ASPHAL 77C CONCRETE TAN. TANGENT B. C. B. V. C. BEGIN CURVE T C. BEG. VERTICAL CURVE TOP OF CURB B. W. BACK SIDEWALK W WIDTH C.B. CATCH BASIN V VER77CAL DEPTH C. L. CENTERLINE E. C. END CURVE V.C. VERTICAL CURVE E. P. EDGE PA VEMENT 7 E.G. EDGE GRADE EX. EXISTING AC PAVEMENT E.V.C. END VERTICAL CURVE REMOVAL F. L. FLOW LINE F. S. FINISH SURFACE G. B. GRADE BREAK H.P. HIGH POINT INV. INVERT L. E. LANDSCAPE EASEMENT 0. C. ON CENTER P.C.C. PORTLAND CEMENT CONCRETE (R) RIDGE LINE R/W RIGHT OF WAY - (590.77) INDICATES EXISTING ELEVATION 310.00 INDICATES PROPOSED ELEVATION x-1300 --\ INDICATES EXISTING CONTOUR - 1320- INDICATES PROPOSED CONTOUR DAYLIGHT / CUT -FILL. -LINE 4 O cl- 0 0 E 0 co N J:\126-1984\storm\SD01.dwa. 9/6/2007 1:41:58 PM. Comelia