Loading...
HomeMy WebLinkAbout4315-236�4 10» REFERENCE NOTES: TYPE A TREES: OA 35W MH LIGHTING FIXTURE DIRECT BURIAL TYPE, BRONZE HOUSING WITH 10" TILT FLAT LENS AND ROCK GUARD, HYDREL #M9720-B-35MTG-240NFL- FLC 10-34B-BTR-PC21 12-SF-GEB-LP-BZ. O CONCRETE EMBEDMENT FLUSH WITH BOTTOM OF LENS RING AND SLOPE TO DRAIN. c0 #3 REBAR 2" CLEAR 4" O.C. pO SCHEDULE 40 PVC CONDUIT. SEE ELECTRICAL SITE PLAN FOR SIZE AND WIRING REQUIREMENTS. Q 6" OF PEA GRAVEL. FIXTURE TYPE "A" MOUNTING DETAIL SCALE: NONE CONDUIT/CABLE SCHEDULE CONDUIT NO. DESCRIPTION FROM TO REMARKS O1 2"C, 2#4, 1 #8G LPA MEDIAN LIGHTS - VIA PBA, PBA -1 THRU PBA -14 A -A1 THRU A -A7 O2 2"C, 2#4, 1#8G LPA MEDIAN LIGHTS - VIA PBA, PBA -15 THRU PBA -30 A -A8 THRU A -A18 O3 2"C, 2#4, 1 #8G LPB MEDIAN LIGHTS - VIA PBB, PBB-1 THRU PBB-16 A -B1 THRU A-610 O4 2"C, 2#4, 1#8G LPB MEDIAN LIGHTS - VIA PBB, PBB-17 THRU PBB-28 A -B11 THRU A -B17 O5 2"C, 2#4, 1#8G LPC MEDIAN LIGHTS - VIA PBC, PBC -1 THRU PBC -15 A -C1 THRU A -C8 O6 2"C, 2#4, 1#8G LPC MEDIAN LIGHTS - VIA PBC, PBC -16 THRU PBC -34 A -C9 THRU A -C19 O7 1"C, 2#12, 1#12G JB/FIXTURE "A" FIXTURE "A" @1"C, 2#10, 1#10G LIGHTING PANEL IRRIGATION CONTROLLER LP (A,B,C) IC-(A,B,C) LEGEND AND NOTES: PANEL: LPA BET. STA 281.8 TO STA 297.4 FEEDER ENTRANCE: MOUNTING: ON PEDESTAL PANEL: LPB BET. STA 204.3 TO STA 219. FEEDER ENTRANCE: MOUNTING: ON PEDESTAL PANEL- LPC BET. STA 142.4 TO STA 157. FEEDER ENTRANCE: MOUNTING: ON PEDESTAL SERVICE: 240/120 VOLTS SINGLE PHASE, 3 WIRE, 10KAIC SERVICE ENTRANCE LABEL: SERVICE: 240/120 VOLTS SINGLE PHASE, 3 WIRE, 10KAIC SERVICE ENTRANCE LABEL: SERVICE: 240/120 VOLTS SINGLE PHASE, 3 WIRE, 10KAIC SERVICE ENTRANCE LABEL: MAIN DEVICE: 100A CB MAIN DEVICE: 100A CB MAIN DEVICE: 100A CB CKT CIRCUIT CB VA PER PHASE CB CIRCUIT CKT CKT CIRCUIT CB VA PER PHASE CB CIRCUIT CKT CKT CIRCUIT CB VA PER PHASE CB CIRCUIT CKT NO. IDENTIFICATION AMPS A B AMPS IDENTIFICATION NO. NO. IDENTIFICATION AMPS A B AMPS IDENTIFICATION NO. NO. IDENTIFICATION AMPS A B AMPS IDENTIFICATION NO. 1 MEDIAN LTS - A -AI THRU A -A7 20/2 546 200 20/1 IRRIGATION CONTROLLER IC -A 2 1 MEDIAN LTS - A -BI THRU A -B10 20/2 780 200 20/1 IRRIGATION CONTROLLER IC -B 2 1 MEDIAN LTS - A -CI THRU A -C8 20/2 624 200 20/1 IRRIGATION CONTROLLER IC --C 2 3 MEDIAN LTS - A -AI THRU A -A7 546 20/1 SPARE 4 3 MEDIAN LTS - A -BI THRU A -B10 780 20/1 SPARE 4 3 MEDIAN LTS - A -CI THRU A -C8 624 20/1 SPARE 4 5 MEDIAN LTS - A -A8 THRU A -A18 20/2 858 20/1 SPARE 6 5 WEDIAN LTS - A -B11 THRU A -B1 20/2 546 20/1 SPARE 6 5 MEDIAN LTS - A -C9 THRU A -C19 20/2 858 20/1 SPARE 6 7 MEDIAN LTS - A -A8 THRU A -A18 858 20/1 SPARE 8 7 OEDIAN LTS - A -B11 THRU A -B1 546 20/1 SPARE 8 7 MEDIAN LTS - A -C9 THRU A -C19 858 20/1 SPARE 8 9 SPARE 20/1 • 20/1 SPARE 10 9 SPARE 20/1 20/1 SPARE 10 9 SPARE 20/1 20/1 SPARE 10 11 LIGHT CONTROL 20/1 100 20/1 SPARE 12 11 LIGHT CONTROL 20/1 100 20/1 SPARE 12 11 LIGHT CONTROL 20/1 100 20/1 SPARE 12 ESTTOTAL VA PER PHASE 1604 1504 EST TOTAL VA PER PHASE 1526 1426 EST TOTAL VA PER PHASE 1682 1582 %> y>' w il i EST TOTAL PANELBOARD VA 3108 EST TOTAL PANELBOARD VA 2952 EST TOTAL PANELBOARD VA 3264 %�i j�,,. ria , y -Al I 0' 20' 40' E-19 NORTH O REV. REVISION DESCRIPTION DATE ENGR. CITY DATE CITY OF FONTANA, CALIFORNIA Prepared Under The Supervision Of SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT J U RU PA AVENUE STREET IMPROVEMENTS COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVALAVVVVVVVVVVVVVWVM DRAWN BY: MEDIAN LIGHTING SCALE NONE SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, ,�`314 m EGS DIAL TWO WORKING THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO r %<' ' DESIGNED BY: DATE: BEFORE DAYS BEFORE `f CABLE/CONDUIT SCHEDULE YOU DIG YOU DIG BRING THEM INTO CONFORMANCE WITH CONDITIONS' , LDS 4/11/2008 HDR Engineering, Inc.'r { APPROVED BY: TOLL FREE 1-800-422133 AND STANDARDS IN EFFECT_ ,q�.� �'��'�' LARRY D_ SMITHEY Date: 6/12/08 CHECKED BY: �. A PUBLIC SERVICE BY/,.l DRAWING NO:7247 UNDERGROUND SERVICE ALERT 0F C WFE ^ X 4315 0 ISSUED FOR BID 1 1 /05 LDS 0 0 Fhl CiTY ENGINEER R.C_E. 51152 DATE: