Loading...
HomeMy WebLinkAbout4315-218 LEGEND AND NOTES. 0 X 0);00AF LOW VOLTAGE CIRCUIT BREAKER (CB). 100 NON-MOTOR LOAD WITH DESIGN KVA, KW OR T TRANSFORMER 0 CONDUIT TURNING UP OR 80AT RATINGS AND NO. OF POLES AS SHOWN. KVA AMPS /// 32p0A 0 3p WHEN SPECIFIC TYPE IS REQUIRED, X INDICATES TYPE. ® SELECTOR SWITCH CONDUIT TURNING DOWN TYPES; Liu, CPT PB PUSHBUTTON MCCB - MOLDED CASE CONTROL POWER TRANSFORMER (CPT) HOME RUN TO PANEL, 2 #12, 1 #12G IN ICCB - INSULATED CASE m INSTRUMENTATION/CONTROL DEVICE 3/4"C UNLESS OTHERWISE NOTED LVP - LOW VOLTAGE POWER MCP - MOTOR CIRCUIT PROTECTOR (RATING PER CONNECTED LOAD) - E- VOLTAGE TRANSFORMER (VT OR PT) I/� ASSOCIATED TOPANEL VENTINTEGRAL OR PROVIDED WITH CIRCUIT RUN BETWEEN DEVICES EXPOSED IN NON-ARCHITECTURALLY FINISHED AREAS, CB SEPARATELY MOUNTED CIRCUIT BREAKER, SEE CONCEALED IN ARCHITECTURALLY FINISHED ELECTRICAL ONE LINE DIAGRAM OR SCHEDULEAREAS. CONDUIT AND CONDUCTOR SIZES SHALL FOR DESCRIPTION E- CURRENT TRANSFORMER (CT) I � BE THE SAME AS THE HOMERUN FOR THE CIRCUIT GFP GROUND FAULT PROTECTION 0 JUNCTION OR PULL BOX UTILITY WATT-HOUR METER PER UTILITY CONDUIT RUN BETWEEN DEVICES CONCEALED IN —1 0REQUIREMENTS PANELBOARD (250V TO 600V) NON-ARCHITECTURALLY FINISHED AREAS, UNDER 52 MEDIUM VOLTAGE CIRCUIT BREAKER FLOOR SLAB OR UNDERGROUND. CONDUIT AND 1 PANELBOARD (LESS THAN 250V) CONDUCTOR SIZES SHALL BE THE SAME AS THE HOMERUN FOR THE CIRCUIT. --LED- FUSE SIZE AND NUMBER OF FUSES AS NOTED DMP DIGITAL METERING PACKAGE ELECTRICAL EQUIPMENT ENCLOSURE: SWITCHBOARD, CIRCUIT HASH MARKS (WHEN INDICATED), LONG, FUSED CUTOUT, CURRENT RATING, FUSE SIZE MOTOR CONTROL CENTER, CONTROL PANEL OR OTHER EQUIPMENT AS INDICATED IIIill SHREORT, SIITGLE DOT AND NEUTR OUB EQUIPMENT AND NUMBER OF POLES AS NOTED RTM RUN TIME METER GROUND AND ISOLATED EQUIPMENT GROUND MS MOTION SENSOR RESPECTIVELY. 12 IN 3 4" CONDUIT UNLESS - FUSIBLE SWITCH, CURRENT RATING, FUSE SIZE # / OTHERWISE INDICATED AND QUANTITY AS NOTED GROUND TMR TIMER CIRCUIT CONTINUATION �- NON-FUSED SWITCH, CURRENT RATING AND NUMBER OF POLES AS NOTED I 0 PHOTOCELL CONDUIT STUBBED OUT AND CAPPED A DISCONNECT OR DRAWOUT CONNECTION J_ LIGHTNING ARRESTER )-7--7,( X CEILING/PENDANT MOUNTED LUMINARY - HID, Y COMPACT FLUORESCENT OR INCANDESCENT ® CONDUIT TAG OR CIRCUIT NUMBER - WIRE AND MAGNETIC MOTOR STARTER AND CONDUIT SIZE AS SPECIFIED IN CIRCUIT AI & q v SEPARATELY MOUNTED COMBINATION MAGNETIC SPD LOW VOLTAGE SURGE PROTECTIVE DEVICE © X WALL MOUNTED LUMINARY - HID, COMPACT SCHEDULE ON THE DRAWINGS B g MOTOR STARTER. I Y X FLUORESCENT OR INCANDESCENT ♦ ELECTRICAL CONNECTION z -- -- GROUND CABLE MOTOR CONTROLLER AND I Z 0 Y CEILING/PENDANT MOUNTED FLUORESCENT D 0 8t D O J SEPARATELY MOUNTED MOTOR CONTROLLER WITH FIXTURE O GROUND ROD / \ \ SHORT CIRCUIT PROTECTION AND DISCONNECT. Iz 2 I X WALL MOUNTED FLUORESCENT FIXTURE OR + OR -I- NO ELECTRICAL CONNECTIONY MOTOR STARTER AND CONTROLLER SUBSCRIPTS; X Al EXTERIOR PADMOUNTED TRANSFORMER A - MAGNETIC STARTER NEMA SIZE (1) OR 0--'I�A --O SOLENOID VALVE .-1): Y AREA OR ROADWAY LIGHT - POLE MOUNTED B STARTER TYPE I LIGHTING FIXTURE SUBSCRIPTS: A POLE MOUNTED TRANSFORMER NONE - FULL VOLTAGE NON-REVERSING (FVNR) X - INDICATES FIXTURE TYPE PER LIGHTING FVR - FULL VOLTAGE REVERSING CONTROL RELAY COIL, X INDICATES TYPE, Y FIXTURE SCHEDULE ■ Y ELECTRICAL HANDHOLE OR MANHOLE 2S - TWO SPEED 0INDICATES LOOPY NO. WHENIUSED Y - INDICATES CIRCUIT NUMBER FROM PANELBOARD Y - MHX OR HHX WHERE X INDICATES RVAT - REDUCED VOLTAGE AUTO TRANSFORMERz - INDICATES CONTROLLING SWITCH (IF REQUIRED) SEQUENCE NUMBER C - CONTROL DIAGRAM OR CONTROLS TYPES: SCHEDULE NUMBER (IF REQUIRED) CR - CONTROL RELAY DP - DEFINITE PURPOSE RELAY FLUSH GRADE MOUNTED HID UPLIGHT FIXTURE D - CONTROLLER TYPE LC - LIGHTING CONTACTOR IN CLUSTER OF 3 (MEDIAN LIGHTS) TB TERMINAL BOX VFD - VARIABLE FREQUENCY DRIVE M - MOTOR STARTER PC - PHOTO CELL SS - SOLID STATE TC - TIME CLOCK TR - TIMING RELAY LCP LOCAL CONTROL PANEL la SEPARATELY MOUNTED COMBINATION MOTOR OFF STARTER OR CONTROLLER, SEE ELECTRICAL HAND AUTO ONE LINE DIAGRAM OR SCHEDULE FOR o X00 3 POSITION SELECTOR SWITCH, MAINTAINED CONTACTS, $X TOGGLE SWITCH DESCRIPTION 1 UNLESS OTHERWISE NOTED, 2 POSITION SIMILAR SUBSCRIPTS: GENERAL NOTES: r —�� X - INDICATES TYPE THERMAL OVERLOAD ELEMENT NONE - SINAL,- POLE 1. THIS IS A STANDARD ELECTRICAL SYMBOLS SHEET. _..1_ NORMALLY OPEN PUSHBUTTON, MOMENTARY ALL SYMBOLS MAY NOT BE USED ON THIS PROJECT. OL 0 0 CONTACT UNLESS OTHERWISE NOTED 3 - THF,EE-WAY THERMAL OVERLOAD RELAY CONTACT4 - FOUR-WAY 2. IN GENERAL CONDUIT ROUTING IS NOT SHOWN ON THE 0_1_0 NORMALLY CLOSED PUSHBUTTON, MOMENTARY HP - TOGGLE SWITCH, HORSEPOWER RATED PLANS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONTACT UNLESS OTHERWISE NOTED K - KEY SWITCH ROUTING ALL CONDUITS INCLUDING THOSE SHOWN ON EP DISCONNECT OR SAFETY SWITCH, 30A, 3P, NON-FUSED UNLESS OTHERWISE NOTED © INDICATING LIGHT, X INDICATES LENS COLOR TE - MANUAL MOTOR STARTER WITH THERMAL ELEMENT ONE-LINES AND HOME RUNS. SEE SPECIFICATIONS FOR P - PILOT LIGHT CONDUIT INSTALLATION REQUIREMENTS. CONDUIT ROUTINGS L - LIGHTED HANDLE AND STUB-UP LOCATIONS THAT ARE SHOWN ARE ,1/41,, _._p. © PUSH TO TEST INDICATING LIGHT, X INDICATES T - TIMER SWITCH APPROXIMATE, EXACT ROUTINGS SHALL BE AS REQUIRED LENS COLOR Y INDICATES CIRCUIT NUMBER FROM PANELBOARD FOR EQUIPMENT FURNISHED. .7-Ne TRANSFORMER LENS COLORS; SPECIAL PURPOSE RECEPTACLE AS DEFINED ON PLANS 3. WHEN BRANCH CIRCUITS ARE NOT SHOWN ON THE PLANS R - RED Y - YELLOW THE CONTRACTOR SHALL FURNISH AND INSTALL ALL 0 3 PHASE, 3 WIRE DELTA CONNECTION G - GREEN W - WHITE CONDUITS AND CONDUCTORS REQUIRED. CONDUIT AND 3 PHASE, 4 WIRE GROUNDED WYE B - BLUE A - AMBER QUAD-DUPLEX RECEPTACLE, TWO NEMA 5-20R CONDUCTOR SIZES SHALL BE THE SAME AS THE HOMERUN CONNECTION Y UNDER COMMON COVER PLATE. FOR THE BRANCH CIRCUIT. X4. SCREENING OR SHADING OF WORK IS USED TO INDICATE 1P100 Y DUPLEX RECEPTACLE, NEMA 5-20R 30, 4 SWITCHBOARD OR PANELBOARD. NAME, VOLTAGE, EXISTING COMPONENTS OR TO DE-EMPHASIZE PROPOSED PHASE, NUMBER OF WIRES WHEN INDICATED. X IMPROVEMENTS TO HIGHLIGHT SELECTED TRADE WORK. Fe SIMPLEX RECEPTACLE, NEMA 5-20R REFER TO CONTEXT OF EACH DRAWING FOR USAGE. Y SUBSCRIPTS; 5. SEE PROJECT EQUIPMENT AND PIPING SYSTEMS DRAWING X - INDICATES TYPE FOR SYMBOLS AND ABBREVIATIONS SPECIFIC TO THE GFCI - GROUND FAULT CIRCUIT INTERRUPTER PROJECT. Y - INDICATES CIRCUIT NUMBER FROM PANELBOARD „, , ,i'''”, ,%V,,,,//,, ,,4, ,,, ',/&'" 'Of CK: ' / ,( 1 % % ilk 0' 20' 40' 60' E-1 NORTH 47 REV. REVISION DESCRIPTION DATE ENGR. CITY DATE i ,r , 1 ,I ,, Prepared Under The Supervision Of: CITY OF F0NTANA, CALIFORNIA SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOTX41 ` . #/4( JURUPA AVENUE STREET IMPROVEMENTS Fa( �s COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL ' ' ATOIA:U go DRAWN BY: SCP.�E:SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, °� 1 ,� ' tGS NONE DIAL TwOwoR�uNG � r3 ELECTRICAL SYMBOLS DATE: THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO DESIGNED BY: BEFORE (� � DAYS BEFORE `x * ; /3.�'- � '; YOU DIG YOU DIG BRING THEM INTO CONFORMANCE WITH CONDITIONS a. U LDS 4/11/2008 HDR Engineering, Inc TOLL FREE �� 1-800-422-4133 4} $ 6 ` J LARRY D_SMITHEY Date: 6/12108 APPROVED BY: AND STANDARDS IN EFFECT. �. ��� CHECKED WFE 4 1�r �/m ,e � DRAWING NO: 218 . r C AS 4315 A PUBLIC SERVICE BY 247 UNDERGROUND SERVICE ALERT 0 ISSUED FOR BID 1 1/05 LDS 0 0 CITY ENGINEER R.C.E.51152 DATE: