Loading...
HomeMy WebLinkAbout3263-630—INCH LINEAR LENGTH OF WIRE, CLEAN BACK FILL SATURATE AND COMPACT TO 90% COILED HARDSCAPING FINISH GRADE/TOP OF MULCH WATER PROOF CONNECTION Z (1 OF 2) %` QUICK -COUPLING VALVE: `� 99 ID TAG RAIN BIRD MODEL 33DRC T 1'I L;�,x � � „� �II_T If1-I NATIVE BACKFILL 2" MINUS vALVEBox 4 VALVE BOX WITH COVER: r�Nlsx GRADE 12 X 18 N y �� �� ,% VALVE BOX WITH COVER: -1 = —III x v�-%III= 1= "!�� �iA��,� ; (LAWN) r�: s, 1_I ,����;�; ��� ' ,ti 6—INCH SIZE FINIS GRADE FINISH GRADE/TOP OF MULCH —III ;� ^ t' NON PRESSURE LATERAL LINE W/SLEEVE BRASS NIPPLE ( O D COVER) Xx > > h S' Th PRESSURE SUPPLY LINE W SLEEVE IIII �I'',4h III ',I uI. ^ill iI1 GR II LI LENGTH AS REQUIRED REMOTE CONTROL VALVE: N / ( ) l� TII IIIx +i11 3—INCH MINIMUM DEPTH OF , 3" MIN. PVC SCH 80 NIPPLE (CLOSE) =1II CONTROL WIRE SLEEVE 3/4—INCH WASHED GRAVEL -III-1�,,,az BRASS STREET ELL PVC SCH 40 ELL =11 SAND BACK FILL III11 -_ BRICK (1 OF 2) PVC SCH 80 NIPPLE 2" MIN l =III =111 1I1=1I I'I �� Oc oo LINE SIZE BRASS GATE VALVE LENGTH AS REQUIRED) ) BRASS NIPPLE WATERsERvrCELIle �U)- BRICK (1 OF 4) (LENGTH AS REQUIRED) (if applicable) o��o ° �� o : , SCH BO NIPPLE (2 -INCH LENGTH. MIN BRASS STREET ELL ) PVC MALE ADAPTOR >` HIDDEN AND SCH 40 ELL NOTES• I I INSTALL CONTROL WIRE SLEEVE ADJACENT TO THE PRESSURE SUPPLY LINE, SIZE PER SPEC. �PVC MAINLINE PIPE ALL SLEEVES TO BE SCH. 40 PVC AND TO BE 2X THE DIAMETER OF THE LINE TO BE PVC SCH 40 TEE OR ELL PVC IRRIGATION MAIN SLEEVED. PVC MAINLINE PIPE 2x4 REDWOOD BLOCK PVC SCH 40 TEE OR ELL * INCREASE THIS DISTANCE TO 36" WHEN SLEEVING UNDER ROADWAYS AND COMMERCIAL BRASS ELL CONTINUOUS AROUND I CUBIC FOOT GRAVEL FILL PVC SCH 40 MALE ADAPTER TRAFFIC WAYS WHEN INSTRUCTED BY INSPECTOR. #4 REBAR W/ PVC LATERAL PIPE SLEEVES SHALL BE EXTENDED BEYOND HARDSCAPE TO POINTS AS REQUESTED BY STAINLESS STEEL GEAR INSPECTOR CLAMPS OR EQUIVALENT PVC SCH 80 UNION FOR 3.0—INCH MINIMUM DEPTH OF NOTE: SUPPORT SYSTEM SERVICING ASSEMBLY -2 EACH 3/4—INCH WASHED GRAVEL IF SLEEVES ARE TO BE USED AT A LATER DATE, CONTRACTOR SHALL TAPE ENDS AND 1. FURNISH FITTINGS AND PIPING NOMINALLY SIZED IDENTICAL TO PROVIDE A VERTICAL MARK AT ENDS OF SLEEVING VISIBLE AT GROUND LEVEL. NOMINAL QUICK COUPLING VALVE INLET SIZE. GATE VALVE N.T.S. 9 REMOTE CONTROL VALVE N.T.S. 7 SLEEVING N.T.S. 4 QUICK -COUPLING VALVE N.T.S. 1 CITY OF FONTANA IRRIGATION CONTROLLER STANDARD FOR COMMUNITY FACILITIES DISTRICTS PRESSURE REGULATOR IF (CFD'S) ONQUIRED. SET SIT[- DRAWING SHOWN REDUCE PRESSURE BACKFLOW PREVENTER 1. Toro Network 8000 Model # 132-86-08 32 station field STRAINE'� #40 �� �� BRASS NIPPLE OF 14 MESH M0'DEL '14 PLACES') satellite controller.' �� WHITE WIRES BRASS ELBOW NBRASS ELBOW BRASS UNION Strong Box Model No. SB— (COMMON) k 2. Mount In S �y ; LL � � 24SS/120V. EE --RELIEF PORT BRASS PIPE ( PLANT MATERIAL BLUE (Stainless Steel) VALVE LOOSE BET,, » X �%L ! — 0 b� BRASS BALL i 0 i BRASS BALL 8, , � VALVE T �;�A'� HOSE BIB % �� Q� WATERPROOF ALL BRASS PIPE 'y%� ,���� ��� , LOCK eox , � FINISH GRADE/TOP OF MULCH WIRE CONNECTIONS 3. Provide Rainmaster 32 PC Pigtail for remote controll O 0� AS PER STD. operation. L, �Lr 8 �ll U4 REBAR . ,.,".« *=4 ,.w.:.,.. 4"_:.:: '�1 Li `r; 7t 4. Provide CambellScientific RED Scientific InC,TE525 tipping bucket �� �"��III�=�>����I�'�I„���II-I, � �FooTING/FouNDaTION � BLACK- MASTER CONTROL (Heavy Duty Model) PRESSURE CONC. STABIOEER�PRESSURE VALVE SUPPLY UNE 'TRUST elocl<) EPONT SUPPLY UNE POP—UP SPRAY SPRINKLER: �-- — 5. Provide Sensor Input Board (SIB) Model #995-63 to �INTAI,E> LDISCHARGE> RAIN BIRD 1800 FLOW SENSOR interface with flow meter and rain shut off device. ,BACKFLOW ENCLOSURE DIAMETER SAME SIZE 6. Provide Radio Link Kit #89-7611 to communicate with 3/4” GRAVEL SEE NOTE BELOW) we+ r-1 nu: h.r iI BRASS ELBOW I AS FLUW Mr -11I JILL RP*A Job No.: Central command. All radio equipment shall be compatible with VHF. Drawn by: KD SMc Revisions: Y;=' BRASS UNIONPVC SCH 80 NIPPLE (LENGTH AS REQUIRED) ° 7. Provide ground rod and surge protection for each 't BRASS BALL -VALVE PVC SCH 40 ELL MINIMUM DI TANCE DOWNSTREAM satellite controller. PVC SCH 40 STREET ELL 5X DIAMETER OF FLOW METER SIZE ., P LA NL. 4�- 44 REBAR PVC SCH 80 NIPPLE Contact:r:,F MINIMUM DISTANCE UPSTREAM Curtis Newman (LENGTH AS REQUIRED) 1OX DIAMETER OF FLOW Star Turf NOTE: BACKFLOW ELCLQSURE,LE MEUR METER SIZE 619 520-6181 OR EQUAL 24"x66"x36" HIGH 619 793-3999 �Pager) .. ENDPVC SCH 40 STREET ELL HINGED AT ONE END SECURE TOOLTS 800 774-8873 Mai ffice) E Q FOOTING"W/4" � CENTERED (EQUIPMENT TO BE CENTERED LNSIDE HOUSING) PVC SCH 40 TEE OR .ELL Park and Landscape Development Section, Engineering Division Community Development Department, City of Fontana (1/26/98) GENERAL NOTES PVC LATERAL PIPE 1. CONTRACTOR SHALL- FORM ENCLOSURE AND REQUEST INSPECTION 24 PRIOR TO POURING FOOTING/EOUITIDATIC�N FLOW METER/MASTER VALVE N .T. S . 10 EXACT LOCATION OF CONTROLLER SHALL BE AGR® BACKFLOWUPON BY EDISON, CITY LANDSCAPE INSPECTOR AND PREVENTER N.T.S . 5 POP-UP SPRAY HEAD N.T.S. 2 WIRECONTRAPLAACCEMENT PRIOR TO ANY TRENCHING OR '�� FINISHED GRADE l� = 6" MIN FROM HARDSCAPES T-71 GENERAL NOTES. NON PRESSURE LATERAL LINE ? z_ PROVIDE 100A METER AND 5QA/2P MAIN C/B WHERE INDICATED ` N -L —1 I I- LATERAL LINE ON DRAWINGS X�1 — PROVIDE PANELBOARD WHERE INDICATED ON DRAWINGS. H —I PRESSURE SUPPLY UNE PROVIDE IRRIGATION CONTROLLER CABINET WHERE INDICATED ON DRAWINGS. —III CONTROLL WIRES TERMINATE AT EXISTION HANDHOLE PER SCECOMPANY REQ. �� % - T i 90 VERIFY EXACT LOCATION AND TERMINATION REQ. WITH S.C.E. CO. — — CI EAN BACK;RILL ELLS � coraouir FOR PRIOR TO TRENCHING i III—III Ells C011TROLLER III _ _ III WIRES CONDUIT AND CONDUCTOR SIZES ARE BASED ON NONMETALLEC CONDUIT —III —III —III—III I I Iff FRONT VIEW AND COPPER CONDUCTORS WITH TYPE 'rHHN/YHWN- INSULATION. -I—I I—III—III—III—III—III—III—III= NTS 6"MIN INI1 C) 1 FINE GRANULAR MATERIAL WILL BE PLACED ON ALL LINES, NO IRT 0 J CONTROL LARGER THAN 1/2 INCH IN SIZE. THIS WILL BE PERMITTED IN THE BOAFD INITIAL BACKFILL MEASURED 6" FROM THE TOP OF PIPE. THE REMAINDER STREEET FACES OF TRENCH CAN BE FILL WITH ROCK SCREENED 2" MINUS. � STREET METER P ALL BACK FILL IS TO BE SATURATED AND COMPACTED TO 90% tj STRONG BOX INSTALL ALL PVC PIPE WITH LABEL UP. MODEL NO. SB— 24SS/120V SNAKE ALL PIPE IN TRENCH. BUNDLE AND TAPE ALL CONTROL WIRES AT 10' O.C. TO PRESSURE SUPPLY > " CHANGES N DIRECTIONNE AND . CITY A SERVICE LOOP AT ALL 90 DEGREE CITY O F FO NTANA , CALIFORNIA Iz- PRESSURE MAIN 2" AND LARGER SHALL BE P.V.C. CLASS 315 7/77-1 SMALLER THAN 2" SHALL BE P.V.C. SCHEDULE 40. Drawn By: Scale: CONTRACTOR SHALL PROVIDE SLEEVES OR CONDUIT OC.F.D. ]LANDSCAPE IMPROV]ENIENT' ]PLANS NES WHEN SIv'c 1 "= 20' SWEEP � MAINLINE INSTALLATION IS UNDER ASPHALT OR CONCRETE. foT� ELLS CONDUIT FOB DPSI �y. C1te: CONTROLLER R.'J.P. �CT No. � 0� �� �� L21 D02 WIRES CONTRACTOR SHALL PROVIDE 24 INCHES OF COVER OVER PIPE L / �' END VIEW SERVING A DRINKING FOUNTAIN OR PRESSURE MAINLINE APLP, Dwg. �,Jo. 6 3" AND LARGER. /P> CITY �UGINEER: RICARDO SANDCVAI LIC. 51152 ExP12/3'I J26 9 NOT USED N.T.S. 11 AUTOMATIC CONTROLLER N.T.S. 8 TRENCHING S N.T.S. 6 NOT USED N.T.S. 3 Landscape Architecture Urban Design & Planning 455 W. 4th St., Ste. C San Bernardino, CA 92401 phone: (909( 888-5568 e-mail: rpa91 @msn.com fax: (909) 3849854 Richard Pope, Landscape Architect CA# 2664 NDSC i �,P APF � �F.�%POPE LOU \\ OF CA1-\ / Client: t"9estern Pacific Development & Construction Co. 6710 Beryl Street Alta Loma, CA 91701 (9C9) 989-2134 Attn: Jack Hull A�A ca co ONCa c� w c€ ^ LI i Ci M y.+ V vi M i a MIN as ti Q G cc M .® co ' ® •� lig" C* o = L6 E M r &I v N ca " r _ a, a- LUp 1® 21 L6 U a I Sheet DeScrlption: Irrigation Details Date: Aug. 21, 2002 RP*A Job No.: 02-20 Drawn by: KD SMc Revisions: Sheet: AOI ( f__%1 jo Of: