HomeMy WebLinkAbout3263-630—INCH LINEAR LENGTH OF WIRE, CLEAN BACK FILL SATURATE AND COMPACT TO 90%
COILED HARDSCAPING FINISH GRADE/TOP OF MULCH
WATER PROOF CONNECTION
Z (1 OF 2) %` QUICK -COUPLING VALVE:
`� 99 ID TAG RAIN BIRD MODEL 33DRC
T 1'I L;�,x � � „� �II_T If1-I NATIVE BACKFILL 2" MINUS
vALVEBox 4 VALVE BOX WITH COVER:
r�Nlsx GRADE 12 X 18 N y �� �� ,% VALVE BOX WITH COVER:
-1 = —III x v�-%III= 1= "!�� �iA��,� ;
(LAWN) r�: s, 1_I ,����;�; ��� ' ,ti 6—INCH SIZE
FINIS GRADE FINISH GRADE/TOP OF MULCH —III ;� ^ t' NON PRESSURE LATERAL LINE W/SLEEVE BRASS NIPPLE
( O D COVER) Xx > >
h S'
Th PRESSURE SUPPLY LINE W SLEEVE
IIII �I'',4h III ',I uI. ^ill iI1 GR II LI LENGTH AS REQUIRED
REMOTE CONTROL VALVE: N / ( )
l� TII IIIx +i11 3—INCH MINIMUM DEPTH OF
, 3" MIN.
PVC SCH 80 NIPPLE (CLOSE) =1II CONTROL WIRE SLEEVE 3/4—INCH WASHED GRAVEL
-III-1�,,,az BRASS STREET ELL
PVC SCH 40 ELL =11 SAND BACK FILL
III11 -_ BRICK (1 OF 2)
PVC SCH 80 NIPPLE 2" MIN l =III =111 1I1=1I I'I
��
Oc oo
LINE SIZE BRASS GATE VALVE
LENGTH AS REQUIRED)
) BRASS NIPPLE
WATERsERvrCELIle �U)- BRICK (1 OF 4) (LENGTH AS REQUIRED)
(if applicable) o��o ° �� o : ,
SCH BO NIPPLE (2 -INCH LENGTH. MIN
BRASS STREET ELL
)
PVC MALE ADAPTOR >` HIDDEN AND SCH 40 ELL NOTES•
I I
INSTALL CONTROL WIRE SLEEVE ADJACENT TO THE PRESSURE SUPPLY LINE, SIZE PER
SPEC.
�PVC MAINLINE PIPE ALL SLEEVES TO BE SCH. 40 PVC AND TO BE 2X THE DIAMETER OF THE LINE TO BE
PVC SCH 40 TEE OR ELL
PVC IRRIGATION MAIN SLEEVED. PVC MAINLINE PIPE
2x4 REDWOOD BLOCK PVC SCH 40 TEE OR ELL * INCREASE THIS DISTANCE TO 36" WHEN SLEEVING UNDER ROADWAYS AND COMMERCIAL BRASS ELL
CONTINUOUS AROUND I CUBIC FOOT GRAVEL FILL PVC SCH 40 MALE ADAPTER TRAFFIC WAYS WHEN INSTRUCTED BY INSPECTOR. #4 REBAR W/
PVC LATERAL PIPE SLEEVES SHALL BE EXTENDED BEYOND HARDSCAPE TO POINTS AS REQUESTED BY STAINLESS STEEL GEAR
INSPECTOR CLAMPS OR EQUIVALENT
PVC SCH 80 UNION FOR 3.0—INCH MINIMUM DEPTH OF NOTE: SUPPORT SYSTEM
SERVICING ASSEMBLY -2 EACH 3/4—INCH WASHED GRAVEL IF SLEEVES ARE TO BE USED AT A LATER DATE, CONTRACTOR SHALL TAPE ENDS AND 1. FURNISH FITTINGS AND PIPING NOMINALLY SIZED IDENTICAL TO
PROVIDE A VERTICAL MARK AT ENDS OF SLEEVING VISIBLE AT GROUND LEVEL. NOMINAL QUICK COUPLING VALVE INLET SIZE.
GATE VALVE N.T.S. 9 REMOTE CONTROL VALVE N.T.S. 7 SLEEVING N.T.S. 4 QUICK -COUPLING VALVE
N.T.S. 1
CITY OF FONTANA
IRRIGATION CONTROLLER STANDARD
FOR COMMUNITY FACILITIES DISTRICTS
PRESSURE REGULATOR IF
(CFD'S) ONQUIRED. SET SIT[- DRAWING SHOWN REDUCE PRESSURE
BACKFLOW PREVENTER
1. Toro Network 8000 Model # 132-86-08 32 station field STRAINE'� #40 �� �� BRASS NIPPLE
OF 14 MESH M0'DEL '14 PLACES')
satellite controller.' ��
WHITE WIRES BRASS ELBOW NBRASS ELBOW BRASS UNION
Strong Box Model No. SB—
(COMMON) k
2. Mount In S �y ; LL � �
24SS/120V. EE --RELIEF PORT BRASS PIPE ( PLANT MATERIAL
BLUE (Stainless Steel) VALVE LOOSE BET,, » X �%L ! — 0 b�
BRASS BALL i 0
i BRASS BALL
8, , � VALVE T
�;�A'�
HOSE BIB % �� Q�
WATERPROOF ALL BRASS PIPE 'y%� ,���� ��� , LOCK eox , � FINISH GRADE/TOP OF MULCH
WIRE CONNECTIONS 3. Provide Rainmaster 32 PC Pigtail for remote controll O
0�
AS PER STD. operation. L, �Lr 8 �ll U4 REBAR
. ,.,".« *=4 ,.w.:.,.. 4"_:.:: '�1 Li `r; 7t
4. Provide CambellScientific RED
Scientific InC,TE525 tipping bucket �� �"��III�=�>����I�'�I„���II-I, � �FooTING/FouNDaTION �
BLACK- MASTER CONTROL (Heavy Duty Model)
PRESSURE CONC. STABIOEER�PRESSURE
VALVE
SUPPLY UNE 'TRUST elocl<) EPONT SUPPLY UNE POP—UP SPRAY SPRINKLER:
�-- — 5. Provide Sensor Input Board (SIB) Model #995-63 to �INTAI,E> LDISCHARGE> RAIN BIRD 1800
FLOW SENSOR interface with flow meter and rain shut off device.
,BACKFLOW ENCLOSURE
DIAMETER SAME SIZE 6. Provide Radio Link Kit #89-7611 to communicate with 3/4” GRAVEL SEE NOTE BELOW)
we+ r-1 nu: h.r iI BRASS ELBOW
I
AS FLUW Mr -11I JILL
RP*A Job No.:
Central command. All radio equipment shall be
compatible with VHF.
Drawn by:
KD SMc
Revisions:
Y;='
BRASS UNIONPVC
SCH 80 NIPPLE
(LENGTH AS REQUIRED)
°
7. Provide ground rod and surge protection for each
't
BRASS BALL
-VALVE
PVC SCH 40 ELL
MINIMUM DI TANCE DOWNSTREAM satellite controller.
PVC SCH 40 STREET ELL
5X DIAMETER OF FLOW METER SIZE ., P LA NL. 4�-
44 REBAR
PVC SCH 80 NIPPLE
Contact:r:,F
MINIMUM DISTANCE UPSTREAM Curtis Newman (LENGTH AS REQUIRED)
1OX DIAMETER OF FLOW Star Turf NOTE: BACKFLOW ELCLQSURE,LE MEUR
METER SIZE 619 520-6181 OR EQUAL 24"x66"x36" HIGH
619 793-3999 �Pager)
.. ENDPVC SCH 40 STREET ELL
HINGED AT ONE END SECURE TOOLTS
800 774-8873 Mai ffice) E Q FOOTING"W/4" � CENTERED (EQUIPMENT TO BE CENTERED
LNSIDE HOUSING) PVC SCH 40 TEE OR .ELL
Park and Landscape Development Section, Engineering Division
Community Development Department, City of Fontana (1/26/98) GENERAL NOTES PVC LATERAL PIPE
1. CONTRACTOR SHALL- FORM ENCLOSURE AND REQUEST INSPECTION
24 PRIOR TO POURING FOOTING/EOUITIDATIC�N
FLOW METER/MASTER VALVE N .T. S . 10 EXACT LOCATION OF CONTROLLER SHALL BE AGR®
BACKFLOWUPON BY EDISON, CITY LANDSCAPE INSPECTOR AND PREVENTER N.T.S . 5 POP-UP SPRAY HEAD N.T.S. 2
WIRECONTRAPLAACCEMENT PRIOR TO ANY TRENCHING OR
'�� FINISHED GRADE
l� = 6" MIN FROM HARDSCAPES
T-71
GENERAL NOTES. NON PRESSURE LATERAL LINE
? z_
PROVIDE 100A METER AND 5QA/2P MAIN C/B WHERE INDICATED
` N -L —1 I I- LATERAL LINE
ON DRAWINGS X�1 —
PROVIDE PANELBOARD WHERE INDICATED ON DRAWINGS.
H —I
PRESSURE SUPPLY UNE
PROVIDE IRRIGATION CONTROLLER CABINET WHERE INDICATED
ON DRAWINGS. —III
CONTROLL WIRES
TERMINATE AT EXISTION HANDHOLE PER SCECOMPANY REQ. �� % - T i
90 VERIFY EXACT LOCATION AND TERMINATION REQ. WITH S.C.E. CO. — — CI EAN BACK;RILL
ELLS � coraouir FOR PRIOR TO TRENCHING
i III—III
Ells C011TROLLER
III _ _ III
WIRES CONDUIT AND CONDUCTOR SIZES ARE BASED ON NONMETALLEC CONDUIT —III —III —III—III I I Iff
FRONT VIEW AND COPPER CONDUCTORS WITH TYPE 'rHHN/YHWN- INSULATION. -I—I I—III—III—III—III—III—III—III=
NTS
6"MIN
INI1 C) 1 FINE GRANULAR MATERIAL WILL BE PLACED ON ALL LINES, NO
IRT 0 J CONTROL LARGER THAN 1/2 INCH IN SIZE. THIS WILL BE PERMITTED IN THE
BOAFD INITIAL BACKFILL MEASURED 6" FROM THE TOP OF PIPE. THE REMAINDER
STREEET FACES OF TRENCH CAN BE FILL WITH ROCK SCREENED 2" MINUS.
�
STREET
METER P ALL BACK FILL IS TO BE SATURATED AND COMPACTED TO 90%
tj STRONG BOX INSTALL ALL PVC PIPE WITH LABEL UP.
MODEL NO. SB— 24SS/120V
SNAKE ALL PIPE IN TRENCH.
BUNDLE AND TAPE ALL CONTROL WIRES AT 10' O.C. TO PRESSURE
SUPPLY > " CHANGES N DIRECTIONNE AND . CITY
A SERVICE LOOP AT ALL 90 DEGREE CITY O F FO NTANA , CALIFORNIA
Iz-
PRESSURE MAIN 2" AND LARGER SHALL BE P.V.C. CLASS 315
7/77-1 SMALLER THAN 2" SHALL BE P.V.C. SCHEDULE 40. Drawn By: Scale:
CONTRACTOR SHALL PROVIDE SLEEVES OR CONDUIT OC.F.D. ]LANDSCAPE IMPROV]ENIENT' ]PLANS NES WHEN SIv'c 1 "= 20'
SWEEP � MAINLINE INSTALLATION IS UNDER ASPHALT OR CONCRETE. foT�
ELLS CONDUIT FOB DPSI �y. C1te:
CONTROLLER R.'J.P. �CT No. � 0� �� �� L21 D02
WIRES CONTRACTOR SHALL PROVIDE 24 INCHES OF COVER OVER PIPE L / �'
END VIEW SERVING A DRINKING FOUNTAIN OR PRESSURE MAINLINE APLP, Dwg. �,Jo. 6
3" AND LARGER. /P>
CITY �UGINEER: RICARDO SANDCVAI LIC. 51152 ExP12/3'I J26 9
NOT USED N.T.S. 11 AUTOMATIC CONTROLLER N.T.S. 8 TRENCHING
S N.T.S. 6 NOT USED N.T.S. 3
Landscape Architecture
Urban Design & Planning
455 W. 4th St., Ste. C San Bernardino, CA 92401
phone: (909( 888-5568 e-mail: rpa91 @msn.com
fax: (909) 3849854
Richard Pope, Landscape Architect CA# 2664
NDSC
i �,P APF �
�F.�%POPE
LOU
\\ OF CA1-\ /
Client:
t"9estern Pacific Development
& Construction Co.
6710 Beryl Street
Alta Loma, CA 91701
(9C9) 989-2134
Attn: Jack Hull
A�A
ca
co
ONCa
c� w
c€ ^
LI
i
Ci
M y.+
V vi M
i a
MIN as
ti
Q G
cc M .® co
' ® •� lig"
C* o = L6 E
M
r &I v
N ca " r _
a,
a- LUp 1® 21 L6 U a
I
Sheet DeScrlption:
Irrigation Details
Date:
Aug. 21, 2002
RP*A Job No.:
02-20
Drawn by:
KD SMc
Revisions:
Sheet:
AOI
( f__%1
jo
Of: