Loading...
HomeMy WebLinkAbout4789-11. ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE 22. CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES CITY OF FONTANA STANDARD PLANS, THE CONTRACT PROVISIONS FROM UNDERMINING STREET IMPROVEMENTS. UPON INSPECTION OF THE AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY NON-ERODABLE CONSTRUCTION ('GREEN BOOK'. ALL REFERENCE SPECIFICATIONS SWALES ENTERING OR LEAVING IMPROVEMENTS. AND STANDARDS SHALL BE THE LATEST EDITION UNLESS OTHERWISE NOTED. 23 ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR TO PAVING OF STREETS. 2. WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT 24. UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL RESTORE DOCUMENTS THAT CAN NOT BE RESOLVED BY REFERENCE TO ALL SIGNING, STRIPING, BARRICADES, AND OTHER TRAFFIC PRECEDENCE PROVISIONS IN THE 'GREEN BOOK-, THE CONTRACTOR CONTROL DEVICES TO THE SA71SFACTION OF THE CITY TRAFFIC ENGINEER. SHALL IMMEDIATELY REPORT SAID CONFLICT TO THE CITY ENGINEER FOR RESOLUTION. 1 25. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO 3. ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE THE ENGINEER OF RECORD, WHO SHALL PROVIDE RECORD DRAWINGS CITY ENGINEER. TO THE CITY ENGINEER. 4. CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVELOPMENT DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC RIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL (909) 350-7610. 5. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND PROCEDURES DESCRIBED IN THE STATE OF CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST NON -METRIC EDITION UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER. 6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS OR OTHER TRAFFIC CONTROL DEVICES AT ALL TIMES. 7. THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK FOR TRENCHES 5 FEET OR GREATER IN DEPTH FROM THE CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY. 8. THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SWILL BE GUARDED BY SHORING, SLOPING OF THE GROUND OR OTHER APPROVED MEANS PURSUANT TO THE REQUIREMENTS OF THE DIVISION OF INDUSTRIAL.. SAFETY OF THE STATE OF CALIFORNIA TRENCHES LESS THAN FIVE (5) FEET SHALL ALSO BE GUARDED WHEN THE POTENTIAL FOR GROUND MOVEMENT EXISTS. 9. NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT-OF-WAY WITHOUT OBTAINING A SEPARATE PERMIT FOR THAT PURPOSE. 10. THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION. HOWEVER, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE, IN THE FIELD, THE TRUE LOCATION AND ELEVATION OF ANY EXISTING UTILITIES, AND TO EXERCISE PROPER PRECAUTION TO A; DID DAMAGE THERETO. THE CONTRACTOR SWILL CONTACT UNDERGROUND SERVICE ALERT AT 1-800-227-2600 TWO WORKING DAYS BEFORE EXCAVATION. 11. THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES INCLUDING, BUT NOT LIMITED TO, GAS, TELEPHONE, FI_ECTRIC, CABLE TELEVISION, LANDSCAPING, LANDSCAPE IRRiCATION, DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAIN, FLO(k CONTROL AND CALTRANS. ALL UTILITY COMPANIES SHALL BE G� IFN TWO WORKING DAYS NOTICE PRIOR TO WORK AROUND THEIR FACILE PES. 12. THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES WITHOUT APPROPRIATE AGENCY AUTHORIZATION. CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE WATER COMPANY FOR VALVE OPERATION AND WATER REQUIREMENTS. 13. STATIONING REFERS TO THE CENTERLINE OF STREETS, EXCEPT WHERE OTHERWISE NOTED. 14. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT TIES OR BENCHMARKS WITHOUT PRIOR NOTIFICATION TO THE C17Y ENGINEER. 15. REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING SURVEY MONUMENTS, MONUMENT TIES AND BENCHMARKS, SWILL BE DONE BY A REGISTERED CML ENGINEER OR LICENSED LAND SURVEYOR. SURVEY MONUMENTS THAT WILL BE DESTROYED AS A RESULT OF THIS CONSTRUCTION SHALL BE REPLACED. THE CONTRACTOR SHALL NOTIFY THE ENGINEER ONE WEEK PRIOR TO CONSTRUCTION SO THAT TIES TO MONUMENTS CAN BE ESTABLISHED FOR LATER REPLACEMENT OF THE MONUMENT. 16. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES. A MINIMUM 12 FOOT LANE SHALL BE MAINTAINED AT ALL TIMES IN THE CONSTRUCTION AREA FOR RESIDENTS AND EMERGENCY VEHICLES. 17. THE CONTRACTOR SWILL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL, INCLUDING ADEQUATE WATERING, AT ALL TIMES. 18. ALL GRADING OPERATIONS SHILL. BE DISCONTINUED WHEN SUSTAINED WIND VELOCITIES EXCEED 25 MILES PER HOUR. 19. THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL., MUD, SILT OR DEBRIS TO BE DEPOSITED ONTO PUBLIC OR PRIVATE PROPERTY ADJACENT TO THE RIGHT-OF-WAY DURING CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL. 20. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR. 21. A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION. FAILURE TO OBTAIN THE REQUIRED DENSITY SHALL REQUIRE RE -WORKING OF THAT PORTION OF THE WORK UNTIL THE SPECIFIED DENSITY IS OBTAINED. SAM OF BEAFOW THE NORTH UNE OF THE SOUTHEAST QUARTER OF SECTION 36, TIN, RK S.B.M. AS SHOWN ON TRACT 16568, MB 300/59-62, BEING N 89'59'12"E Cz A O REV. De_ b TOU FREE -800-227-2600 A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT ��11 • •if 110k, • I - • tijj CITY OF FONTANA S.B.C. INC. 8353 SIERRA AVENUE 3939 E. CORONADO STREET FONTANA, CA 92335 ANAHEIM, CA 92807 (909) 350-6632 (714) 666-5500 SO. CALIF. GAS COMPANY UNDERGROUND SERVICE ALERT 1981 W. LUGONIA AVENUE (800) 422-4133 REDLANDS, CA 92374 (909) 335-7547 EMERGENCIES: (800) 427-2200 PACIFIC BELL CO. 3939 E. CORONADO STREET SO. CALIF EDISON COMPANY ANAHEIM, CA 92807 (714) 666-5467 300 N. PEPPER AVENUE RIALTO, CA 92376 VERIZON (TELEPHONE) 820-5598 - UNDERGROUND 1400 E. PHILIPS BLVD. 1909 909 875-5100 - TRANSMISSION ONTARIO, CA 91766 213 637-1233 - PIPELINES (800) 483-4000 909 357-6505 - DISTRIBUTION FONTANA WATER COMPANY ADELPHW 1500 S. AUTO CENTER DRIVE 8440 NUEVO AVENUE ONTARIO, CA 91761 FONTANA CA 92235 (909) 822-2201 (909) 481-1115 FAX: (909) 823-5046 Yl - !ril • •� • •• •' THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES AND/OR STRUCTURES SHOWN ON THESE PLANS WERE OBTAINED BY A SEARCH OF THE AVAILABLE RECORDS. THESE LOCATIONS ARE APPROXIMATE AND SHALL BE CONFIRMED BY THE CONTRACTOR, SO THAT ANY NECESSARY ADJUSTMENT CAN BE MADE IN ALIGNMENT AND/OR GRADE OF THE PROPOSED IMPROVEMENT. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT ANY UTILITY LINES SHOWN AND ANY OTHER LINES NOT ON RECORD OR NOT SHOWN ON THESE PLANS. CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, HE WILL BE REQUIRED TO ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THE PROJECT, INCLUDING THE SAM OF ALL PERSONS AND q CITY OF FONTANA CALIFORNIA CAPITAL IMPROVEMENT PROJECA TAILWIND LANE TO CITRUS AVE. LANDSCAPE IMPROVEMENTS OCINrff MAP UUUU a s W LOCAVONO I W SEM 2, 6,10 SfEETs a 7,11 OEM it I I w III II I) I REVISION DESCRIPTION DATE ENGR. CITY DATE QWUL BENCH( 1011�� CITY OF FONTANA BM -361 WT C IM" PREPARED FOR: R.R. SPIKE IN PP NO. 1536697E AT THE SW CORNER TWO YEARS OF 7 E DATE OF APPF10VAL CITY OF FONTMA OF BASELINE AVENUE AND SULTANA AVENUE. SIM HOEM AND GAMED FOM N A 8353 SIERRA AVENUE ELEVATION: 1365.01, SINCE DESTROYED Maw 7HE CITY MAY FONTANA, CA 92335 FIEOlME FIEWSM Tn 7FE PLANS M (909) 350-7610 SM BEVCHMW i Tf�l WOWH FAX 909 350-6618 SW CORNER, SEC. 31, TIN., R.5W., S.BM.-2" I.P. COMRXWWE ( ) WITH BRASS CAP, C.S.M. AT THE INTERSECTION OF AND STANDAFDS N QCT BASELINE AVENUE AND CITRUS AVENUE. E MA71#I= SITE INDEX MAP SCALE: r aar srEer INDEX 1 TITLE SHEET 2-4 LAYOUT AND CONSTRUCTION PLAN 5 CONSTRUCTION DETAILS 6-8 IRRIGATION PLAN 9 IRRIGATION CONSTRUCTION DETAILS 10-12 PLANTING PLAN 13 PLANTING CONSTRUCTION DETAILS Q�OFESSI 3 LU No. 43976 rn Up. "-69 Prepared By. a��Fci'` CITY OF FONTANA, CALIFORNIA IL LARD ENGINEERING CAPITAL IMPROVEMENT PROJECT )SCAPE ARCHITECTS, Inc. Ci it Engineering - Land Surveying - Land Planning DRAWN BY: SCALE: 8253 Sierra Avenue CAD TRE SHEU W Av 1 •=20' �► Fontana, California 92335 15 South 5th Street 9 356-1815 Fax 909 56-1795 DESIGNED BY: DATE. Redlands, Carfomia 92373 ( ) ( S.T.B. TO AVE. 6/28/2007 �(q-w) 79(1--7490 Fox �(909) 307-8235 � � 81'710-7 lac. 27245, 'Ti tic. No. 82 CHECKED 8Y: APP �, DRAWING NO.: 1 Ian arc .com David S. Hammer, R.C.E. 43976 Date 4" / (expires 6/30/2009) CITY ENGff R R.C.E. 51152 4789 1 c N