Loading...
HomeMy WebLinkAbout4787LT-1N N ) ( PROJECT NORTH TRUE NORTH 0 20 40 80 120 GRAPHIC SCALE SCALE: 1"=40' FONTANA COMMUNITY SENIOR CENTER STREET LIGHTING PLAN PARCEL MAP 17999 CITY OF FONTANA, CALIFORNIA LEGEND FOR STREET LIGHT PLANS: Q INDICATES EXISTING 9500 LUMEN HPSV STREET LIGHT (100 WATT; #10) 27 FT. LUMINAIRE HEIGHT. OINDICATES FUTURE 9500 LUMEN HPSV STREET LIGHT (100 WATT; #10) 27 FT. LUMINAIRE HEIGHT. V INDICATES FIRE HYDRANT CIVIL ENGINEER'S NOTICE TO CONTRACTOR: 1. THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES OR STRUCTURES SHOWN ON THEIR PLANS ARE OBTAINED BY A SEARCH OF THE AVAILABLE RECORDS. TO THE BEST OF MY KNOWLEDGE, THERE ARE NO EXISTING UTILITIES EXCEPT AS SHOWN ON THESE PLANS. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTION— ANY MEASURES TO PROTECT THE UTILITIES AND STRUCTURES SHOWN AND ANY OTHER LINES OR STRUCTURES NOT OF RECORD OR NOT SHOWN ON THESE PLANS, AND IS RESPONSIBLE FOR THE PROTECTION OF, AND ANY DAMAGE TO, THESE LINES OR STRUCTURES. 2. THE CONTRACTOR AGREES THAT HE WILL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS, AND THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY, AND HOLD THE OWNER AND ENGINEER HARMLESS FROM ANY AND ALL LIABILITY REAL OR ALLEGED IN CONNECTION WITH THE PERFORMANCE OR WORK ON THIS PROJECT, EXCEPTING FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER OR THE ENGINEER, OR ANY PUBLIC AGENCY. 3. THE ESTIMATES OF IMPROVEMENT QUANTITIES AS SHOWN HEREON ARE PROVIDED ONLY FOR THE PURPOSE OF SATISFYING DISTRICT PLAN INFORMATION REQUIREMENTS. THE CONTRACTOR SHALL PERFORM AN INDEPENDENT ESTIMATE OF ALL IMPROVEMENT QUANTITIES AND SHALL USE SAME AS A BASIS FOR HIS BIDS) AND CONTRACT(S) 4. CONTRACTOR TO VERIFY CLEARANCE AT ALL UTILITY CROSSINGS. IF INTERFERENCE OCCURS, OTHER THAN NOTED ON PLAN, CONTRACTOR TO CONTACT DESIGN ENGINEER FOR POSSIBLE REDESIGN. IF REDESIGN IS UNFEASIBLE, CONTRACTOR TO RELOCATE UTILITY AT NO EXPENSE TO ENGINEER. CITY OF FONTANA BENCH MARK 435 TOP OF FIRE HYDRANT AT SOUTHEAST CORNER OF CERES AVENUE AND SIERRA AVENUE SET SEPTEMBER 1967 ELEVATION - 1244.00 1-800-422-4133 IT'S THE LAW CALL AT LEAST DIAL BEFORE TWO WORKING YOU DIG! DAYS PRIOR TO EXCAVATING �iCA UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA BEFORE EXCAVATING, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UTILITY UNDERGROUND SERVICE ALERT AT 1-800-422-4133 CONSTRUCTION NOTES: 4 EA. ( --INSTALL STREET LIGHT IN ACCORDANCE WITH CITY OF FONTANA STD 404. LUMINAIRE AND CASE PER LEGEND. 1 EA. @_RELOCATE EXISTING STREET LIGHT TO LOCATION SHOWN HEREON. 1 EA. 26 REMOVE EXISTING LIGHT POLE IN THE LOCATION SHOWN. REVISION DESCRIPTION STREET GENERAL NOTES: 1. ORNAMENTAL STREET LIGHT POLES SHALL BE MARBELITE OR APPROVED EQUAL. 2. THE LUMINAIRE SHALL CONSIST OF COBRA HEAD CUT-OFF LENS ON A 6 FOOT OR 8 FOOT MAST ARM. A 15 FOOT MAST ARM REQUIRED FOR STREET LIGHTS ON TRAFFIC SIGNAL POLE INSTALLATIONS. 3. ANY CHANGE IN LOCATION OF STREET LIGHTS FROM THE APPROVED PLANS IS SUBJECT TO APPROVAL BY THE CITY ENGINEER. 4. SIDEWALK WIDTHS TO BE PER APPROVED STREET IMPROVEMENT PLANS. A MINIMUM OF 4 FEET UNOBSTRUCTED SIDEWALK CLEARANCE REQUIRED BEHIND STREET LIGHT POLE. 5. ALL STREET LIGHTS SHALL BE INSTALLED PER CITY STANDARD PLAN 404. SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO BRING THEM INTO CONFORMANCE WITH STANDARDS IN EFFECT. SOILS ENGINEER JOHN R. BYERLY INC. 2257 SOUTH LILAC AVENUE BLOOMINGTON, CA 92316-2907 (909) 877-1324 (909) 877-5210 FAX SEAL QROFESS/ FG xZ No. 38382 ;0* Exp. 03-31-11 J+JgT C 1 v I L F OF CA0� PROPERTY OWNER FONTANA REDEVELOPMENT AGENCY, A CALIFORNIA PUBLIC AGENCY c/o KEN HUNT, CITY MANAGER 8353 SIERRA AVENUE FONTANA, CA. 92335 ARROW BLVD a VALENCIA AV a H ORANGE WAY SCRRA (BNSF) (METROLINK) CERES MERRILL DMV ❑ Q ATHOL 0 Ln w a a r U RANDALL r AV Z d Q a UU� J W w > Q Qo z w w z w Ln z 0 w z a m 'ARK ❑ & RID a,I w a z AV VICINITY MAP NOT TO SCALE REFERENCE: 2006 SAN BERNARDINO CO. THOMAS GUIDE PG. 604 J\ S I MSL / ENGINEERING, INC. CIVIL ENGINEERS AND LAND SURVEYORS SPECIALIZING IN SITE DEVELOPMENT 402 WEST ARROW HWY., SUITE 4, SAN DIMAS, CA. 91773 (909) 305-2395 FAX (909) 305-2397 Prepared Under The Supervision Of: DRAWN BY: MARK S. LAMOUREUX G.R.H. DESIGNED BY: M.S.L. Exp. Date: 03-31-11 Date :05-04-09 CHECKED BY: ENGR'S NAME. R.C.E. 38382 M.S.L. CITY OF FONTANA, CALIFORNIA STREET LIGHTING PLAN APP PARCEL MAP 17999 EN DATE;/ R.C.E. 5115 SCALE: 1 "= 40' DATE: 05-04-09 DRAWING NO.: Yj 4787LT AV w > w> w w> > Q z c �a wQ w Z m AV 0 W Z � c ST Q J 0 w in AV VICINITY MAP NOT TO SCALE REFERENCE: 2006 SAN BERNARDINO CO. THOMAS GUIDE PG. 604 J\ S I MSL / ENGINEERING, INC. CIVIL ENGINEERS AND LAND SURVEYORS SPECIALIZING IN SITE DEVELOPMENT 402 WEST ARROW HWY., SUITE 4, SAN DIMAS, CA. 91773 (909) 305-2395 FAX (909) 305-2397 Prepared Under The Supervision Of: DRAWN BY: MARK S. LAMOUREUX G.R.H. DESIGNED BY: M.S.L. Exp. Date: 03-31-11 Date :05-04-09 CHECKED BY: ENGR'S NAME. R.C.E. 38382 M.S.L. CITY OF FONTANA, CALIFORNIA STREET LIGHTING PLAN APP PARCEL MAP 17999 EN DATE;/ R.C.E. 5115 SCALE: 1 "= 40' DATE: 05-04-09 DRAWING NO.: Yj 4787LT