HomeMy WebLinkAbout4787LT-1N N
) (
PROJECT NORTH TRUE NORTH
0 20 40 80 120
GRAPHIC SCALE
SCALE: 1"=40'
FONTANA
COMMUNITY SENIOR CENTER
STREET LIGHTING PLAN
PARCEL MAP 17999
CITY OF FONTANA, CALIFORNIA
LEGEND FOR STREET LIGHT PLANS:
Q INDICATES EXISTING 9500 LUMEN HPSV STREET LIGHT (100 WATT; #10) 27 FT. LUMINAIRE HEIGHT.
OINDICATES FUTURE 9500 LUMEN HPSV STREET LIGHT (100 WATT; #10) 27 FT. LUMINAIRE HEIGHT.
V INDICATES FIRE HYDRANT
CIVIL ENGINEER'S NOTICE TO CONTRACTOR:
1. THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES OR STRUCTURES
SHOWN ON THEIR PLANS ARE OBTAINED BY A SEARCH OF THE AVAILABLE RECORDS. TO THE
BEST OF MY KNOWLEDGE, THERE ARE NO EXISTING UTILITIES EXCEPT AS SHOWN ON THESE
PLANS. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTION— ANY MEASURES TO
PROTECT THE UTILITIES AND STRUCTURES SHOWN AND ANY OTHER LINES OR STRUCTURES NOT
OF RECORD OR NOT SHOWN ON THESE PLANS, AND IS RESPONSIBLE FOR THE PROTECTION OF,
AND ANY DAMAGE TO, THESE LINES OR STRUCTURES.
2. THE CONTRACTOR AGREES THAT HE WILL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR
JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT, INCLUDING
SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS REQUIREMENT SHALL APPLY
CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS, AND THAT THE CONTRACTOR
SHALL DEFEND, INDEMNIFY, AND HOLD THE OWNER AND ENGINEER HARMLESS FROM ANY AND
ALL LIABILITY REAL OR ALLEGED IN CONNECTION WITH THE PERFORMANCE OR WORK ON THIS
PROJECT, EXCEPTING FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER OR
THE ENGINEER, OR ANY PUBLIC AGENCY.
3. THE ESTIMATES OF IMPROVEMENT QUANTITIES AS SHOWN HEREON ARE PROVIDED ONLY FOR
THE PURPOSE OF SATISFYING DISTRICT PLAN INFORMATION REQUIREMENTS. THE CONTRACTOR
SHALL PERFORM AN INDEPENDENT ESTIMATE OF ALL IMPROVEMENT QUANTITIES AND SHALL USE
SAME AS A BASIS FOR HIS BIDS) AND CONTRACT(S)
4. CONTRACTOR TO VERIFY CLEARANCE AT ALL UTILITY CROSSINGS. IF INTERFERENCE OCCURS,
OTHER THAN NOTED ON PLAN, CONTRACTOR TO CONTACT DESIGN ENGINEER FOR POSSIBLE
REDESIGN. IF REDESIGN IS UNFEASIBLE, CONTRACTOR TO RELOCATE UTILITY AT NO EXPENSE TO
ENGINEER.
CITY OF FONTANA BENCH MARK 435
TOP OF FIRE HYDRANT AT SOUTHEAST CORNER OF CERES
AVENUE AND SIERRA AVENUE
SET SEPTEMBER 1967
ELEVATION - 1244.00
1-800-422-4133
IT'S THE LAW CALL AT LEAST
DIAL BEFORE TWO WORKING
YOU DIG! DAYS PRIOR TO
EXCAVATING
�iCA
UNDERGROUND SERVICE ALERT
OF SOUTHERN CALIFORNIA
BEFORE EXCAVATING, THE CONTRACTOR SHALL VERIFY
THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING
UTILITY UNDERGROUND SERVICE ALERT AT 1-800-422-4133
CONSTRUCTION NOTES:
4 EA. ( --INSTALL STREET LIGHT IN ACCORDANCE WITH CITY OF FONTANA STD 404.
LUMINAIRE AND CASE PER LEGEND.
1 EA. @_RELOCATE EXISTING STREET LIGHT TO LOCATION SHOWN HEREON.
1 EA. 26 REMOVE EXISTING LIGHT POLE IN THE LOCATION SHOWN.
REVISION DESCRIPTION
STREET GENERAL NOTES:
1. ORNAMENTAL STREET LIGHT POLES SHALL BE MARBELITE OR APPROVED EQUAL.
2. THE LUMINAIRE SHALL CONSIST OF COBRA HEAD CUT-OFF LENS ON A 6 FOOT
OR 8 FOOT MAST ARM. A 15 FOOT MAST ARM REQUIRED FOR STREET LIGHTS ON
TRAFFIC SIGNAL POLE INSTALLATIONS.
3. ANY CHANGE IN LOCATION OF STREET LIGHTS FROM THE APPROVED PLANS IS
SUBJECT TO APPROVAL BY THE CITY ENGINEER.
4. SIDEWALK WIDTHS TO BE PER APPROVED STREET IMPROVEMENT PLANS. A MINIMUM OF
4 FEET UNOBSTRUCTED SIDEWALK CLEARANCE REQUIRED BEHIND STREET LIGHT POLE.
5. ALL STREET LIGHTS SHALL BE INSTALLED PER CITY STANDARD PLAN 404.
SHOULD CONSTRUCTION OF THE REQUIRED
IMPROVEMENTS NOT COMMENCE WITHIN TWO
YEARS OF THE DATE OF APPROVAL SHOWN HEREON
AND CARRIED FORTH IN A DILIGENT MANNER, THE
CITY ENGINEER MAY REQUIRE REVISIONS TO THE
PLANS TO BRING THEM INTO CONFORMANCE WITH
STANDARDS IN EFFECT.
SOILS ENGINEER
JOHN R. BYERLY INC.
2257 SOUTH LILAC AVENUE
BLOOMINGTON, CA 92316-2907
(909) 877-1324
(909) 877-5210 FAX
SEAL
QROFESS/
FG
xZ
No. 38382 ;0* Exp. 03-31-11
J+JgT C 1 v I L
F OF CA0�
PROPERTY OWNER
FONTANA REDEVELOPMENT AGENCY,
A CALIFORNIA PUBLIC AGENCY
c/o KEN HUNT, CITY MANAGER
8353 SIERRA AVENUE
FONTANA, CA. 92335
ARROW
BLVD
a
VALENCIA AV
a
H
ORANGE WAY
SCRRA (BNSF) (METROLINK)
CERES
MERRILL
DMV ❑
Q
ATHOL
0
Ln
w
a
a
r
U
RANDALL
r
AV
Z d
Q a
UU�
J
W
w
>
Q
Qo
z w
w z w
Ln z
0 w z
a m
'ARK ❑ & RID
a,I
w
a
z
AV
VICINITY MAP
NOT TO SCALE
REFERENCE: 2006 SAN BERNARDINO CO. THOMAS GUIDE PG. 604
J\ S I MSL
/ ENGINEERING, INC.
CIVIL ENGINEERS AND LAND SURVEYORS SPECIALIZING IN SITE DEVELOPMENT
402 WEST ARROW HWY., SUITE 4, SAN DIMAS, CA. 91773
(909) 305-2395 FAX (909) 305-2397
Prepared Under The Supervision Of:
DRAWN BY:
MARK S. LAMOUREUX G.R.H.
DESIGNED BY:
M.S.L.
Exp. Date: 03-31-11 Date :05-04-09 CHECKED BY:
ENGR'S NAME. R.C.E. 38382 M.S.L.
CITY OF FONTANA, CALIFORNIA
STREET LIGHTING PLAN
APP
PARCEL MAP 17999
EN
DATE;/
R.C.E. 5115
SCALE:
1 "= 40'
DATE:
05-04-09
DRAWING NO.: Yj
4787LT
AV
w > w>
w
w>
>
Q
z c �a
wQ
w Z
m AV
0
W
Z
�
c
ST
Q
J
0
w
in
AV
VICINITY MAP
NOT TO SCALE
REFERENCE: 2006 SAN BERNARDINO CO. THOMAS GUIDE PG. 604
J\ S I MSL
/ ENGINEERING, INC.
CIVIL ENGINEERS AND LAND SURVEYORS SPECIALIZING IN SITE DEVELOPMENT
402 WEST ARROW HWY., SUITE 4, SAN DIMAS, CA. 91773
(909) 305-2395 FAX (909) 305-2397
Prepared Under The Supervision Of:
DRAWN BY:
MARK S. LAMOUREUX G.R.H.
DESIGNED BY:
M.S.L.
Exp. Date: 03-31-11 Date :05-04-09 CHECKED BY:
ENGR'S NAME. R.C.E. 38382 M.S.L.
CITY OF FONTANA, CALIFORNIA
STREET LIGHTING PLAN
APP
PARCEL MAP 17999
EN
DATE;/
R.C.E. 5115
SCALE:
1 "= 40'
DATE:
05-04-09
DRAWING NO.: Yj
4787LT