HomeMy WebLinkAbout4394-1A CONDUCTOR TABLE AWG. CIRCUIT OR RUNS - - - - - - - - TYPE 02 DETECTOR - - POLE 1 2 3 4 5 6 7 8 9 10 - POLE - 2 - - - - - J �4 DETECTOR - o POLE - 3 - 3 3 3 3 0 05 DETECTOR - - - - - - - - - - 19A-4-100 06 DETECTOR - o POLE/ 4 4 - - - - - 11' 07 DETECTOR - - - - 2 - 2 2 2 2 — 08 DETECTOR - O � POLE - 3 - - - - - 250 W TOTAL - `V POLEZD 4 14 - 5 5 9 9 TYPE 1—A 10' — — — B 4 N — TV -2—T SP-1—CS — 11' 4' Q 0 POLE 35' 20' 15' 250 W B 4 N MAS SV -1—T SP-1—CS M POLE 4' 8 TYPE 30 35' — 15' 250 W B 6 E — SV -1—T SP-1—CS — 11' 4' POLE TOTAL 1/1 2/2 3/3 4/4 -/- 4/4 1/1 2/2 3/3 4/4 10 ILUMINAIRE 2 1 2 1 2 1 - I - I - 1 2 1 2 1 2 1 2 OPTICOM CABLE 1 1 1 1 1 2 1 2 1 - 1 2 1 - 1 1 1 1 1= CONDUIT SIZE 2"3" 3" 3" 3" 3" 2" 3" 3" 3" ® - ALL CONDUIT AND CONDUCTORS ARE NEW. MATCHLINE "A" W A BREAK LINE OF 60' ' 5 I I c� l11 !� ; I , �I II i U U x I j o 1 �I / I w' t I 19 I ~ X I X ' t5 ( w j w. wo /uj J (� I X j X I o !, 24 12 241 o I w 7' W( SCE SERVICE SOURCE j POWER POLE #705551E ` c5 I I W _ _ 22 F71 x—x—x— x—x—x—x—x—x— N _ 04 i I IC) �� �� I ! % I 20 I I S j I o �' / cv 2 )t06 / 04 MATCHLINE "A" W/ A BREAK LINE OF 60' \ _ - _� r� ,iii FIBER/CONDUITS TO NEW P48 SPLICE VAULT ON �LjJ;` NORTHWEST QUADRANT OF CHERRY AVE. /FOOTHILL BLVD. / INSTALL P48 ADJACENT TO EXISTING SIGNAL 20 22 i \ CONTROLLER CABINET. APPROX 1500 FEETO /� O6p� ! f � �`POP - m POLE SCHEDULE 01 DETECTOR - - - - - - - - - - TYPE 02 DETECTOR - - - - 4 - - - 4 4 A 03 DETECTOR - - - - 2 - - - - - J �4 DETECTOR - - - - 3 - 3 3 3 3 0 05 DETECTOR - - - - - - - - - - 19A-4-100 06 DETECTOR - 4 4 4 4 - - - - - 11' 07 DETECTOR - - - - 2 - 2 2 2 2 — 08 DETECTOR - - - - 3 - - - - - 250 W TOTAL - 4 4 4 14 - 5 5 9 9 OPTICOM CABLE 1 1 1 1 1 2 1 2 1 - 1 2 1 - 1 1 1 1 1= CONDUIT SIZE 2"3" 3" 3" 3" 3" 2" 3" 3" 3" ® - ALL CONDUIT AND CONDUCTORS ARE NEW. MATCHLINE "A" W A BREAK LINE OF 60' ' 5 I I c� l11 !� ; I , �I II i U U x I j o 1 �I / I w' t I 19 I ~ X I X ' t5 ( w j w. wo /uj J (� I X j X I o !, 24 12 241 o I w 7' W( SCE SERVICE SOURCE j POWER POLE #705551E ` c5 I I W _ _ 22 F71 x—x—x— x—x—x—x—x—x— N _ 04 i I IC) �� �� I ! % I 20 I I S j I o �' / cv 2 )t06 / 04 MATCHLINE "A" W/ A BREAK LINE OF 60' \ _ - _� r� ,iii FIBER/CONDUITS TO NEW P48 SPLICE VAULT ON �LjJ;` NORTHWEST QUADRANT OF CHERRY AVE. /FOOTHILL BLVD. / INSTALL P48 ADJACENT TO EXISTING SIGNAL 20 22 i \ CONTROLLER CABINET. APPROX 1500 FEETO /� O6p� ! f � �`POP - m POLE SCHEDULE L STANDARD MASTARMS LUMINAIRE PED PUSH BT. SIGNAL MOUNTING PHASE 2 R.S.N.S. PLACEMENT REMARKS C TYPE HT. SIG. LUM. H.P.S.V. TYPE PHASE QUAD VEHICLE POLE PED. MESSAGE A B 5 1 29A-5-100 35' 55' 15' 250 W B 6 E 3—MAS SV -1—T SP-1—CS $ See Below 11' 4' F=17' 2 TYPE 1—A 10' — — — B 8 S — N -2—T SP-1—CS — 11' 4' 1 3 19A-4-100 35' 25' 15' 250 W B 8 S MAS SV -11 —T SP-1—CS See Below 11' 4' NORMAL 4 TYPE 30 35' — 15' 250 W B 2 W — SV -11 —T SP-1—CS — 11' 4' 22 5 29A-5-100 35' 55' 15' 250 W B 2 W 3—MAS SV -11 —T SP-1—CS See Below 11' 4' F=17' 6 TYPE 1—A 10' — — — B 4 N — TV -2—T SP-1—CS — 11' 4' 7 19A-4-100 35' 20' 15' 250 W B 4 N MAS SV -1—T SP-1—CS See Below 11' 4' 8 TYPE 30 35' — 15' 250 W B 6 E — SV -1—T SP-1—CS — 11' 4' ALL EQUIPMENT IS NEW. INSTALL REFLECTORIZED STREET NAME SIGN (R.S.N.S) RSNS MESSAGES 2 * SPECIAL LENGTH MASTARM ON POLE SHAFT USING SPECIAL CITY FURNISHED MAST ARM. O Redwood Ave 8000 I 3 r... 0 t 2"C, 2#10 (LIGHTING) 4 I JI FIBER/CONDUITS TO NEW P48 SPLICE VAULT ON %% 2"C, 2#6, 1 #8 (S11 NAL`SERVICE, GFCI) NORTHEAST QUADRANT OF HEMLOCK AVE. /FOOTHILL BLVD. INSTALL P48 ADJACENT TO EXISTING SIGNAL 4 1 9 16 11 CONTROLLER CABINET. APPROX 2600 FEET --- EX. R/W - 9 10 11 / � 02 ��j 4 5 ` 5 6 7 2"C, 3 DLC/E,' R/W 2"C, 1 DLC _------- --- ------------ 08 ( \ -_ _�_--- - --- _ _ _ _ _---------- — 02 -----�--� -- I/ OS — _�— 02 —_� - - 5 - -- - 5 !��--I--�— -- cV LO CV r O3 0 Foothill 47 0 ( @Redwood s 00 �7 Q Foothill Blvd 14600 Z: Q 07 - '� ------ ---- i Ld / I i Q) S D � (/ SDI ' s ' 3 ___ — f ___ SD l I — — — cn — 345' TO BACK OF X -WALK 101+00 98+00 _ - - --- - - - ----- 17 -------- - 8 ------- 5 — - — r 5 c 6 n LO n6j LOOP PLACEMENT & SAWCUT DETAIL 5 i 30' 15' 10' �' TYP. TYP. TYP. TYPr 10' ----5 ----- — TYP. EX. R/W 2"C, 1 DLC GENERAIL NOTES: 1, TRAFFIC SIGNAL, SIGNING AND STRIPING, AND LIGHTING SHALL CONFORM TO THESE PLANS, THE SPECIAL PROVISIONS, THE CITY OF FONTANA STANDARD DETAILS, AND THE STATE OF CALIFORNIA STANDARD SPECIFICATIONS SECTION 86 AND STANDARD PLANS (DATE MAY 2006). 2. LOCATION OF ALL UNDERGROUND FACILITIES ARE APPROXIMATE. THE CONTRACTOR SHALL POTHOLE TO DETERMINE THE EXACT LOCATIONS AND VERIFY ALL CONDITIONS ON THE JOB' SITE. HAND DIG FOUNDATIONS UNTIL CLEAR OF ANY OBSTRUCTIONS. PHONE UNDERGROUND SERVICE ALERT AT (800) 227-2600, TWO (2) WORKING DAYS BEFORE DIGGING. 3. ALL PULLBOXES SHALL BE No. 6 AND CONDUIT SHALL BE 2" RIGID METAL UNLESS OTHERWISE SHOWN. 4. CONTRACTOR SHALL MAKE APPLICATION FOR ELECTRIC SERVICE AND SCHEDULING WITH SOUTHERN CALIFORNIA EDISON COMPANY WELL IN ADVANCE OF NEED. 5. CONTRACTOR. SHALL OBTAIN APPROVAL FROM THE ENGINEER FOR EXACT EQUIPMENT LOCATIONS PRIOR TO FINAL PLACEMENT. SEE ES -4C FOR POLE LOCATION DETAIL. 6. ALL REQUIRED CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA ENGINEERING DIVISION PRIOR TO COMMENCEMENT OF WORK. 7. CONTRACTOR SHALL RELOCATE AND/OR REPLACE LANDSCAPING, SPRINKLERS, AND SIDEWALK AFFECTED BY THE CONSTRUCTION TO THE SATISFACTION OF THE ENGINEER. 8. CONTROLLER CABINET SHALL NOT BE SUBJECTED TO WATER FROM SPRINKLERS. MODIFY SPRINKERS SYSTEMS IF NECESSARY. 9. THE ALIGNMENT OF INTERCONNECT DUCTS SHALL BE AS STRAIGHT AS POSSIBLE. HOWEVER, WHEN CHANGES IN ALIGNMENT ARE NECESSARY, SWEEPS SHALL HAVE MINIMUM RADIUS OF 10 FEET. 10. ALL VEHICLE INDICATIONS SHALL BE 12" AND HAVE L.E.D. SIGNAL MODULES. ALL PEDESTRIAN HEADS SHALL HAVE L.E.D. PEDESTRIAN MODULES EQUIPPED WITH COUNTDOWN TIMERS (SEE SPECIAL PROVISIONS). 11. ANY EXISTING TRAFFIC SIGNALS AND LIGHTING SHALL REMAIN IN OPERATION UNTIL REPLACED WITH NEW CONSTRUCTION. 12. CONTRACTOR TO FURNISH ALL EQUIPMENT, MATERIALS, AND HARDWARE TO CONSTRUCT THE TRAFFIC SIGNAL AND LIGHTING AS SHOWN ON THE PLANS, EXCEPT AS NOTED CITY FURNISHED OR LISTED AS CITY PROVIDED IN THE SPECIAL PROVISIONS. 13. CONTRACTOR SHALL REFER TO THE CITY ENGINEER IN THE EVENT OF A CONFLICT OR POTENTIAL CONFLICT WITH THESE PLANS AND, OR SPECIFICATIONS FOR THIS PROJECT. 14. WHERE TRAFFIC SIGNAL STREET CROSSING CONDUIT ARE NOT INSTALLED USING THE BORING METHOD, TRENCH REPAIRS SHALL BE SPECIAL PROVISIONS, SECTION E. 15. TRAFFIC SIGN DIMENSIONS, COLOR, AND LETTERING SHALL CONFORM TO THE LATEST CALTRANS SIGN SPECIFICATIONS SHEETS. SIGN CODES SHOWN HEREON ARE TO CONFORM TO CA M.U.T.C.D. CODES. TRAFFIC SIGN SIZE SHALL BE FOR CONVENTIONAL ROADWAYS UNLESS OTHERWISE SHOWN ON THE PLANS. L -G — — — — — C — — — —G— — — — — — G — — ---- --------- ---_ --_ --- 2"C, 3 DLC FOOTHILL LEGEND: � - UNI -DIRECTIONAL, SINGLE CHANNEL OPTICAL DETECTOR. BARRIER PHASE DIAGRAM NOT USED ' SENSOR UNIT PHASE 1 PHASE 2 PHASE 3 PHASE 4 NOT USED I ' 1 2 NORMAL 2-E-8 PHASE 5 PHASE 61 PHASE 7 PHASE 8 I' TRIANGLE TYPE E LOOP DETECTOR SAWCUT DETAIL m 13 1 2 `{ `� 0g v 5 3 t 2 it 102+ o I •- 03 0+ -- - - - C/L - - ------1 i :.J' 7 7 G 0 I1p, 06 MAST—ARM MOUNTING CLAMP FOR OPTICAL DETECTOR G — G I IT -T06 06 41 i I; 103 00 9 t 9 it 9 - - - - - r--- - --------------- 5 i L� AO Ijl 04 i i t Ilj i i II, L 04, f.t (4„G) ��. � r—;;`- - EX.0/G , 04 _=�- ��------- ----T--- - -- ------ ------- (uGE)--------------- Z4P (D I � EX. R/W L�-j k, i 13 15 I I o 02 bat 16' a 1;2' 18' I � ; t 34' 34' i 22' !4' J 5Oil ; o i U ! U W 114 W I N I f ►I W II i II t MBS m Q I O 16 M— X i J 1000 i it LL fr 5 cS I N CONSTRUCTION NOTES: 0 , ------�- - - - o 345' TO BACK OF X -WALK (U GE)-- --—� — Z Q Q - o NOTE: SEE SPECIAL PROVISIONS FOR ANY CITY SUPPLIED EQUIPMENT AND/OR MATERIALS. Q 1 INSTALL CITY FURNISHED TYPE 90 CONTROLLER EQUIPMENT PACKAGE INCLUDING TYPE "R" CABINET, cm BATTERY BACKUP, AND APPURTENANT EQUIPMENT. CONTROLLER CABINET AND FOUNDATION SHALL Q BE INSTALLED PER CITY STANDARD DRAWING 4004. CONTRACTOR SHALL FURNISH AND INSTALL �. W ANY ADDITIONAL ELECTRONIC EQUIPMENT REQUIRED TO PROVIDE THE SIGNAL OPERATION AS SHOWN ON THE PLAN. ❑FURNISH & INSTALL TYPE III -BF SERVICE EQUIPMENT ENCLOSURE PER CITY OF FONTANA AND 2 SOUTHERN CALIFORNIA EDISON COMPANY REQUIREMENTS. FURNISH AND INSTALL 3" PVC CONDUIT WITH 1/4" POLY PULL ROPE PER SCE REQUIREMENTS. U Q COORDINATE SERVICE WITH SCE (CHRIS LORIMER 909-357-6240). ct 4❑ FURNISH & INSTALL R3-4 SIGN ON MAST ARM PER CALTRANS STD. PLAN ES -7N, DETAIL "U". INSTALL CITY FURNISHED UNI -DIRECTIONAL, SINGLE CHANNEL OPTICOM DETECTOR (MODEL 711 OR EQUAL) PER DETAIL ON THIS SHEET AND AS DIRECTED BY THE ENGINEER. J FURNISH AND INSTALL SPLICE VAULT (P48) W/SPLIT FIBERGLASS LID. SPLICE VAULT SHALL BE LABELED "COMMUNICATIONS". 20 10 0 20 40 60 0OM �J M7 FURNISH & INSTALL 2"C, J Ql STR.4tJ > FI13E2. C6113C.L. ❑8 REMOVE STREET LIGHT BY SCE, AFTER SIGNAL IS ENERGIZED. T� FURNISH AND INSTALL SIX (6) 1-1/2" HIGH DENSITY POLYETHELENE (HDPE) CONDUITS BY y DIRECTIONAL DRILL UNDER PAVEMENT OR SIDEWALK, OR BY TRENCH IN SOIL. CONDUITS SHALL BE COLOR CODED ORANGE, YELLOW, RED, BLACK, BLUE AND GREEN. FURNISH AND INSTALL ONE PULL O ROPE IN ALL CONDUITS (EXCEPT ORANGE) FOR FUTURE CABLE. CONDUIT SWEEPS SHALL BE O INSTALLED WITH A MINIMUM OF 10 -FOOT RADIUS. 10 FURNISH & INSTALL 96 STRAND FIBER IN ORANGE CONDUIT. A 5m r_0 11 FURNISH & INSTALL P48 SPLICE VAULT EVERY 600', & ONE AT EACH SIGNALIZED INTERSECTION, INCLUDING CHERRY AVE. AUTOCAD FILENAME: FOOTHILL.REDWOOD.TS.DWG TCRMIn)PI`W 0- S7L-tAjD Sr1Fo C/}f>Lc UvTO j(p STTZtVD CAi� Pen- spice cifaer / SERVICE ADDRESS: 8089 Redwood Ave. SENSOR TABLE SENSOR UNIT CHANNEL OPERATION DETECTOR- 0 NO. 1 1 EXTENSION 1-E-8 1 2 NORMAL 2-E-8 2 2 1 NORMAL ="3-E-8 3 2 SPARE - 4 3 1 EXTENSION - - 5 2 NORMAL 2-W-4 6 4 1 NORMAL 3-W-4 7 2 SPARE - 8 5 1 NORMAL 1-E-3 9 2 COUNT 2-E-3 10 6 1 SPARE - 11 2 SPARE - 12 7 1 RM 3-S-2 13 2 COUNT -S-2 14 8 1 NORMAL 2-S-2 15 2 EXTENSION 1-S-2 16 1 COUNT 1-W-7 17 9 2 NORMAL 2-W-7 18 10 1 1-N-6 19 2 NORMAL 2-N-6 20 11 1 N 5-N-6 21 2 NORMAL 22 Z Q Q - o NOTE: SEE SPECIAL PROVISIONS FOR ANY CITY SUPPLIED EQUIPMENT AND/OR MATERIALS. Q 1 INSTALL CITY FURNISHED TYPE 90 CONTROLLER EQUIPMENT PACKAGE INCLUDING TYPE "R" CABINET, cm BATTERY BACKUP, AND APPURTENANT EQUIPMENT. CONTROLLER CABINET AND FOUNDATION SHALL Q BE INSTALLED PER CITY STANDARD DRAWING 4004. CONTRACTOR SHALL FURNISH AND INSTALL �. W ANY ADDITIONAL ELECTRONIC EQUIPMENT REQUIRED TO PROVIDE THE SIGNAL OPERATION AS SHOWN ON THE PLAN. ❑FURNISH & INSTALL TYPE III -BF SERVICE EQUIPMENT ENCLOSURE PER CITY OF FONTANA AND 2 SOUTHERN CALIFORNIA EDISON COMPANY REQUIREMENTS. FURNISH AND INSTALL 3" PVC CONDUIT WITH 1/4" POLY PULL ROPE PER SCE REQUIREMENTS. U Q COORDINATE SERVICE WITH SCE (CHRIS LORIMER 909-357-6240). ct 4❑ FURNISH & INSTALL R3-4 SIGN ON MAST ARM PER CALTRANS STD. PLAN ES -7N, DETAIL "U". INSTALL CITY FURNISHED UNI -DIRECTIONAL, SINGLE CHANNEL OPTICOM DETECTOR (MODEL 711 OR EQUAL) PER DETAIL ON THIS SHEET AND AS DIRECTED BY THE ENGINEER. J FURNISH AND INSTALL SPLICE VAULT (P48) W/SPLIT FIBERGLASS LID. SPLICE VAULT SHALL BE LABELED "COMMUNICATIONS". 20 10 0 20 40 60 0OM �J M7 FURNISH & INSTALL 2"C, J Ql STR.4tJ > FI13E2. C6113C.L. ❑8 REMOVE STREET LIGHT BY SCE, AFTER SIGNAL IS ENERGIZED. T� FURNISH AND INSTALL SIX (6) 1-1/2" HIGH DENSITY POLYETHELENE (HDPE) CONDUITS BY y DIRECTIONAL DRILL UNDER PAVEMENT OR SIDEWALK, OR BY TRENCH IN SOIL. CONDUITS SHALL BE COLOR CODED ORANGE, YELLOW, RED, BLACK, BLUE AND GREEN. FURNISH AND INSTALL ONE PULL O ROPE IN ALL CONDUITS (EXCEPT ORANGE) FOR FUTURE CABLE. CONDUIT SWEEPS SHALL BE O INSTALLED WITH A MINIMUM OF 10 -FOOT RADIUS. 10 FURNISH & INSTALL 96 STRAND FIBER IN ORANGE CONDUIT. A 5m r_0 11 FURNISH & INSTALL P48 SPLICE VAULT EVERY 600', & ONE AT EACH SIGNALIZED INTERSECTION, INCLUDING CHERRY AVE. AUTOCAD FILENAME: FOOTHILL.REDWOOD.TS.DWG TCRMIn)PI`W 0- S7L-tAjD Sr1Fo C/}f>Lc UvTO j(p STTZtVD CAi� Pen- spice cifaer / SERVICE ADDRESS: 8089 Redwood Ave.