HomeMy WebLinkAbout3396-26• 1. :• 004110001) 1�_ Iv l CHLINE, SEE SHEET LI -2 1 /4" SLEEVE 1-4 WIRES 1/2" PII 1/2" SLEEVE 5-10 WIRES 3/4" PII SLEEVE 11-20 WIRES 1 " PII 1/2" SLEEVE 21-30 WIRES 1 1/4- PII SLEEVE 31-40 WIRES 1 1/2" P11 SLEEVE 41-60 WIRES 2" PII SLEEVE 61 -99 WIRES 2 1/2"-3" PII SLEEVE 100+ WIRES 4" PII Q 4649 Brockton Avenue O REV. Riverside, CA 92506 / o (909) 369-0700 DIAL TWO WORKING Fax(909)369-4039 BEFORE DAYS BEFORE YOU DIG YOU DIG http://www.comworksdg.com TOLL FREE 1-800-227-2600 A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT REVISION DESCRIPTION '.O.C. 'C' INFORMATION ATER TYPE FATIC PRESSURE =AK DEMAND JURCE AT FONTANA WATER 4TF INM ORTAINPn POTABLE 90 PSI 33 GPM 1 t1 1W) /r l? 3' 4' 4' 4' Q U CL m c.v v c.v 0 a - EQUIPMENT LEGEND SYMBOL MANUFACTURER/MODEL # SIZE DETAIL 3/ © \/f --I -- 34 -- -- -- -- 3/4 -- -- , CITY f LI -7 TURF POP-UP SPRAY HEADS . 0 A EXISTING IRRIGATION WATER METER TO REMAIN, PROTECT IN PLACE 2" All - 3' 4' 4' 4' Q U CL m c.v v c.v 0 a - EQUIPMENT LEGEND SYMBOL MANUFACTURER/MODEL # SIZE DETAIL NOTES © HYDROBOOST BOOSTER PUMP SYSTEM, FACTORY PRE -PIPED AND PRE -WIRED, 2 HP 'E','F'&'G' _ CITY AVAILABLE FROM BEAR STATE PUMPS 800-350-1660 CONTACT: TOM LANG LI -7 TURF POP-UP SPRAY HEADS . 0 A EXISTING IRRIGATION WATER METER TO REMAIN, PROTECT IN PLACE 2" N/A - C'A' TORO NETWORK 8000 (132-86-08) IRRIGATION CONTROLLER LOCATED IN A 32 STA. 'A', L-2 (1,2) STRONG BOX ENCLOSURE (SEE CONTROLLER NOTE ® E TORO 570Z-PRX-6P-8-COM 'A' EXISTING FEBCO 825Y BACKFLOW PREVENTER TO REMAIN, PROTECT IN PLACE. 2" 'B', L-2 (4) .44 CONTRACTOR TO PROVIDE NEW STRONG BOX BC-45CR ENCLOSURE. .86 'A', L-2 ,A. CLA-VAL 93-01 NORMALLY CLOSED PRESSURE REGULATING MASTER VALVE 2" 'E', L-2 (3) A CALSENSE FM -1.258 FLOW SENSOR 1 1/4" 'E', L-2 (3) B EXISTING IRRIGATION PUMP - N/A - ®B IRRIGATION WATER METERS (1 EXISTING TO REMAIN, 1 NEW) (2) 2" N/A - C'BI C B2 TORO NETWORK 8000 (132-86-08) IRRIGATION CONTROLLER LOCATED INA 32 STA. 'A', L-2 (1,2) 'A', L-2 STRONG BOX ENCLOSURE (SEE .CONTROLLER NOTE) b j5 O TORO 570Z-PRX-6P-15-COM Q/T/H/F B FEBCO 880V REDUCED PRESSURE BACKFLOW PREVENTER 4" 'B', L-2 (4) (D'B' CLA-VAL 93-01 NORMALLY CLOSED PRESSURE REGULATING MASTER VALVE 2 1/2" 'E, L-2 (3) SHRUB HI -POP SPRAY HEADS CALSENSE FM -2B FLOW SENSOR 2" 'E', L-2 (3) ®C IRRIGATION WATER METER 1 1/2" N/A - O, C C' TORO NETWORK 8000 (132-8(-08) IRRIGATION CONTROLLER LOCATED IN A 32 STA. 'A', L-2 (1,2) 7'-8' STRONG BOX ENCLOSURE SEE CONTROLLER NOTE) .22 .29 .44 'C' tEg FEBCO 825Y BACKFLOW PREVENTER LOCATED IN A STRONG BOX BC-45CR 2" 'B', L-2 (4) E 6 -0 TORO 570Z-PRX-12P-10-COM VANDEL RESISTANT ENCLOSURE. 9'-10' 30 .33 ®C CLA-VAL 93-01 NORMALLY CLOSED PRESSURE REGULATING MASTER VALVE 2" 'E', L-2 (3) 'B', L-2 CALSENSE FM -1.258 FLOW SENSOR 1 1/4" 'E', L-2 (3) 30 NIBCO BRONZE BALL VALVE 2" AND LESS: T-585 (BALL) 2 1/2" AND MORE: WD2000 (BUTTERFLY) LINE SIZE 'C', L-2 (3) ® RAINBIRD #33DLRC SERIES QUICK COUPLING VALVE 3/4" 'D', L-2 (3) Q/T/H/TQ/F SUPERIOR 950-DWPRS REMOTE CONTROL VALVE PLAN SIZE 'E', L-2 (3) _ IRRIGATION MAINLINE: SCH. 40 (18" MIN. CVR) - CLS 200/315 (24" MIN. CVR) PLAN SIZE 'F', L-2 (3) (1) UP TO 2": SCH. 40 2 1/2 -4": CLS. 315 6" AND MORE: CLS 200 EST / SST 4'x15' 30 1.431 CLASS 200 PVC NON -PRESSURE LATERAL LINE - 12" MIN. COVER PLAN SIZE 'F', L-2 (3) _ _ _ _ _ _ _ - SCH 40 PVC IRRIGATION PIPE / WIRE SLEEVE - 24" MIN. COVER SEE CHART 'G', L-2 (3) NOT SHOWN 12 GA OF RATED CONTROL WIRE 12 GA 'H', L-2 - ®N 'N' NUMBER OF SPARE WIRES PULLED - 'H', L-2 - (1) LANDSCAPE CONTRACTOR TO COORDINATE ELECTRICAL POWER W/ ELECTRICAL CONTRACTOR (2) SET CONTROL VALVE PRESSURE REGULATORS AS FOLLOWS: 35 PSI FOR SPRAY VALVES / 35 PSI FOR BUBBLER VALVES / 55 PSI FOR 640 SERIES VALVES / 45 PSI FOR XP300 SERIES VALVES / 40 PSI FOR 340 SERIES VALVES THESE SETTINGS CAN BE ADJUSTED IF A DIFFERENT OPERATING PRESSURE IS DETERMINED IN THE FIELD. (3) PIPING AND VALVES ARE SHOWN IN HARDSCAPE FOR CLARITY ONLY. (4) CONTRACTOR TO LOCATE PUMP AND BACKFLOW PREVENTER IN SHRUB AREA AND SCREEN WHENEVER POSSIBLE. (5) MASTER VALVE PRESSURE REGULATOR TO BE SET TO 125 PSI OUTPUT PRESSURE. (6) CONTRACTOR TO INSTALL THRUST BLOCKS AT ALL MAINLINE CHANGES IN DIRECTION PER DETAIL 'K', SHEET LI -6. (7) FLOW SENSOR TO BE SET UP TO MONITOR MAINLINE BREAKS WITH FLOWS OVER 350 GPM. SPRINKLER LEGEND SYMBOL MANUFACTURER/MODEL # NOZZLE RAD. PSI ROW (GPM) DETAIL NOTES Q T CITY F TURF POP-UP SPRAY HEADS . b p TORO 570Z-PRX-6P-5-COM Q/H 5'-6' 30 .09 CALIFORNIA .18 'A', L-2 ® E TORO 570Z-PRX-6P-8-COM Q/H 7'-8' 30 .22 .44 .86 'A', L-2 ® $ TORO 570Z-PRX-6P-10-COM Q/H/F 9'-10' 30 .33 .66 1.3 'A', L-2 p TORO 570Z-PRX-6P-12-COM Q/T/H/F 11'-12' 30 .48 .64 .96 1.9 'A', L-2 b j5 O TORO 570Z-PRX-6P-15-COM Q/T/H/F 13'-15' 30 .7511.011-551 13.0 'A', L-2 SHRUB HI -POP SPRAY HEADS p TORO 570Z-PRX-12P-5-COM H 5'-6' 30 .18 'B', L-2 (1) Eh 6 83 E TORO 570Z-PRX-12P-8-COM Q/T/H 7'-8' 30 .22 .29 .44 .86 'B', L-2 (1) E 6 -0 TORO 570Z-PRX-12P-10-COM Q/T/H/TQ/F 9'-10' 30 .33 .44 .661 1.0 1.3 'B', L-2 (1) .4 ® 6 TORO 5702-PRX-12P-12-COM Q/T/H/TQ/F 11'-12' 30 .48 .64 .96 1.5 1.9 'B', L-2 (1) 6 6 0 6 TORO 5702-PRX-12P-15-COM Q/T/H/TQ/F 13'-15' 30 1.75 1.0 1.5 2.3 3.0 'B', L-2 (1) W 19 TORO 570Z-PRX-12P-4ST-COM EST / SST 4'x15' 30 1.431 .88 1 1 'B', L-2 (1) TURF POP-UP ROTOR HEADS �jo as OO TORO 300-00-02 02 21' 35 10,72 1.441 2.88 'C', L-2 4) 6 4 ® TORO XP 300 -P -XX 05 28' 35 1.01 1.68 2.16 4.23 'C', L-2 6,6 e TORO XP 300 -P -XX 09 41' 50 2.10 3.27 4.19 8.38 'C', L-2 b 6 p TORO 640 -02 -XX 40/42 55' 50 6.70 12.9 12.9 'C', L-2 SHRUB HI -POP ROTOR HEADS 4 4 4 TORO 300-00-02 02 21' 35 0.72 1.44 2.88 'C', L-2 TORO XP 300 -P -XX 05 28' 35 1.01 2.16 4.04 'C', L-2 TORO XP 300 -P -XX 07 36' 35 1.43 2.85 5.70 'C', L-2 TREE BUBBLERS TORO 514-20 BUBBLER F 1 1 30 1 1 1 1 2.40 'D', L-2 1 (2) (1) IN PLANTER AREAS, USE BOTTOM INLET ONLY. (2) INSTALL (2) TWO BUBBLERS PER TREE FOR A TOTAL FLOW OF 4.80 GPM PER TREE. POINT OF CONNECTION NOTES: MAKE POINTS OF CONNECTION AS SHOWN PER FONTANA WATER STANDARDS. INSTALL BACKFLOW PREVENTERS DOWNSTREAM OF METER PER ALL LOCAL CODES. FINAL LOCATION OF BACKFLOW DEVICES TO BE APPROVED IN THE FIELD BY THE OWNER. WHERE POSSIBLE, CONTRACTOR TO SCREEN BACKFLOW DEVICE WITH SHRUBS. INSTALL PUMP PER MANUFACTURER RECOMMENDATIONS DOWNSTREAM OF BACKFLOW PREVENTER. INSTALL MASTER VALVE DOWNSTREAM OF PUMP AND WIRE TO ALL CONTROLLERS (NOTE: CONTROLLERS B1 & B2 WILL NEED A MASTER VALVE RELAY ALLOWING MULTIPLE CONTROLLERS TO OPERATE ONE (1) MASTER VALVE). MASTER VALVE PRESSURE REGULATOR 1S TO BE SET TO OUTPUT 125 PSI MAX PRESSURE. MAXIMUM COMBINED FLOW FOR POC 'A' IS 60 GPM. MAXIMUM COMBINED FLOW FOR POC 'B' IS 137 GPM. MAXIMUM COMBINED FLOW FOR POC 'C' IS 44 GPM. STATIC LOW PRESSURE AT POC 'A' IS 92 PSI. STATIC LOW PRESSURE AT POC 'B' IS 90 PSI. STATIC LOW PRESSURE AT POC 'C' IS 90 PSI. REGULATED PUMP OUTPUT PRESSURE AT ALL POC'S IS 125 PSI. CONTROLLER NOTE: CONTROLLER 'A', 'B', AND 'C' TO BE 32 STATION MODELS. CONTRACTOR TO PROVIDE 120V POWER TO FINAL CONTROLLERS LOCATION. CONTRACTOR TO MAKE ALL FINAL CONNECTIONS PER LOCAL CODES. MOUNT, WIRE, AND GROUND CONTROLLERS PER MANUFACTURER'S DIRECTIONS. FINAL CONTROLLER LOCATION TO BE DETERMINED IN THE FIELD BY THE OWNER. EACH CONTROLLER IS TO HAVE THE FOLLOWING: (1) RAINMASTER 32 PC 'PIGTAIL' FOR REMOTE CONTROLL OPERATION. (1) TORO SENSOR INPUT BOARD (SIB) MODEL 995-63 FOR FLOW SENSOR AND RAIN SHUT OFF DEVICE INPUT. (1) TORO RADIO LINK KIT 89-7611 TO ALLOW COMMUNICATION WITH THE CENTRAL COMMAND CENTER. (1) MASTER VALVE RELAY ALLOWING MULTIPLE CONTROLLERS TO OPERATE ONE MASTER VALVE. (1) CALSENSE TP -110 SURGE PROTECTION DEVICE. (1) GROUNDING ROD. ALL RADIO EQUIPMENT IS TO BE COMPATIBLE WITH VHF FREQUENCY. REMOTE CONTROL VALVES ARE TO BE RUN SIMULTANEOUSLY TO ACHIEVE A COMBINED FLOW OF APPROXIMATELY 325 GPM IN ORDER TO MAKE AN 8 HOUR WATERING WINDOW 5 DAYS A WEEK. CONTRACTOR TO ORDER CONTROLLER AS SOON AS POSSIBLE TO AVOID DELAYS FROM BACKORDERS. COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL moll, SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, ' Signature ®t NORTH THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO -7 -off _ BRING THEM INTO CONFORMANCE WITH CONDITIONS AND �'��, Date ��� DATE SUBMITTED: STANDARDS IN EFFECT. CWDG JOB NUMBER: mmsm� IRRIGATION AS BUILT PLAN It A ARTIN PARK DESIGNED BLL TY < DATE ENGR. CITY DATE SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT R� . �. c DATE: CITY OF FONTANA CALIFORNIA COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL moll, SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, ' Signature ®t NORTH THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO -7 -off _ BRING THEM INTO CONFORMANCE WITH CONDITIONS AND �'��, Date ��� DATE SUBMITTED: STANDARDS IN EFFECT. CWDG JOB NUMBER: mmsm� IRRIGATION AS BUILT PLAN �0 SCALE: ll) -20P0" DATE: 02-07-06 DRAWING NO.: 126/1 3396 Ad It A ARTIN PARK DESIGNED BLL TY < CHECKED BY: TY �`� J �► in.. R� . �. c DATE: �0 SCALE: ll) -20P0" DATE: 02-07-06 DRAWING NO.: 126/1 3396 Ad