Loading...
HomeMy WebLinkAbout3396-25MATCHL INE, SEE SHEET LI -2 4 23b1 36 1.5' REV. _ 4649 Brockton Avenue O Riverside, CA 92506 (909) 369-0700 DIAL Tw❑ WORKING Fax (9os)36s4o3s BEFORE DAYS BEFORE YOU DIG YOU DIG _ hftp://www.comworksdg.com A TOLL FREE 1-800-227-2600 DUO f � rr V � 0 u P A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT 24b1 35 1.5' REVISION DESCRIPTION 28bl 3/4 3/4' Wr� v.� 1 U 29bl - `Z � 30 1.5' ° 3/4 1 X 1� • f I 0 i 4' 4' 1 1 1 I I 1 00 � 1 I i 2' I 1 •I I l 1 I 1 1/2' I 3/4-1 1 2. 1. 1 1 EOUIPMENT LEGEND SYMBOL MANUFACTURER/MODEL # SIZE DETAIL NOTES P A' HYDROBOOST BOOSTER PUMP SYSTEM, FACTORY PRE -PIPED AND PRE -WIRED, 2 HP 'E%'F'&'G' _ 2" AVAILABLE FROM BEAR STATE PUMPS 800-350-1660 CONTACT: TOM LANG 11-20 LI -7 TURF POP-UP SPRAY HEADS 'A' EXISTING IRRIGATION WATER METER TO REMAIN, PROTECT IN PLACE 2" N/A - C 'A' TORO NETWORK 8000 (132-8(-08) IRRIGATION CONTROLLER .LOCATED IN A 32 STA. 'A', L-2 (1,2) WIRES STRONG BOX ENCLOSURE SEE CONTROLLER NOTE PIPE 4" TORO 570Z-PRX-6P-8-COM 'A' EXISTING FEBCO 825Y BACKFLOW PREVENTER TO REMAIN, PROTECT IN PLACE. 2" 'B', L-2 (4) .44 CONTRACTOR TO PROVIDE NEW STRONG BOX BC-45CR ENCLOSURE. WIRES .86 'A', L-2 8" CLA-VAL 93-01 NORMALLY CLOSED PRESSURE REGULATING MASTER VALVE 2" 'E', L-2 (3), 30 CALSENSE FM -1.25B FLOW SENSOR 1 1/4" 'E', L-2 (3) DAB EXISTING IRRIGATION PUMP - N/A - �B IRRIGATION WATER METERS (1 EXISTING TO REMAIN, 1 NEW) (2) 2" N/A - C B1' C 'B2' TORO NETWORK 8000 (132-86-08) IRRIGATION CONTROLLER LOCATED IN A 32 STA. 'A', L-2 (1,2) 'A', L-2 STRONG BOX ENCLOSURE (SEE CONTROLLER NOTE) 6 6 0 -0' TORO 5702-PRX-6P-15-COM Q/T/H/F 1'13 FEBCO 880V REDUCED PRESSURE BACKFLOW PREVENTER 4" 'B', L-2 (4) CLA-VAL 93-01 NORMALLY CLOSED PRESSURE REGULATING MASTER VALVE 2 1/2" 'E', L-2 (3) SHRUB HI -POP SPRAY HEADS CALSENSE FM -213 FLOW SENSOR 2" 'E', L-2 (3) 1��J C IRRIGATION WATER METER 1 1/2" N/A - C'C' l TORO NETWORK 8000 ((132-86-08) IRRIGATION CONTROLLER LOCATED IN A 32 STA. 'A', L-2 (1,2) 30 STRONG BOX ENCLOSURE (SEE CONTROLLER NOTE) .29 .44 'C' CEO FEBCO 825Y BACKFLOW PREVENTER LOCATED IN A STRONG BOX BC-45CR ENCLOSURE. 2" 'B', L-2 (4) 9'-10' VANDEL RESISTANT .33 .44 .66 (5C CLA-VAL 93-01 NORMALLY CLOSED PRESSURE REGULATING MASTER VALVE 2" 'E', L-2 (3) ®'C CALSENSE FM -1.258 FLOW SENSOR 1 1/4" 'E', L-2 (3) .96 NIBCO BRONZE BALL VALVELINE 2" AND LESS: T-585 (BALL) 2 1/2" AND MORE: WD2000 (BUTTERFLY) SIZE 'C ', L-2 (3) ® RAINBIRD #33DLRC SERIES QUICK COUPLING VALVE 3/4" 'D', L-2 (3) SUPERIOR 950-DWPRS REMOTE CONTROL VALVE PLAN SIZE 'E', L-2 (3) (1) IRRIGATION MAINLINE: SCH. 40 (18 MIN. CVR) - CLS 200/315 (24 MIN. CVR) PLAN SIZE 'F', L-2 (3) UP TO 2": SCH. 40 2 1/2" -4": CLS. 315 6" AND MORE: CLS 200 'B', L-2 CLASS 200 PVC NON -PRESSURE LATERAL LINE - 12" MIN. COVER PLAN SIZE 'F', L-2 (3) 35 SCH 40 PVC IRRIGATION PIPE / WIRE SLEEVE - 24" MIN. COVER SEE CHART 'G', L-2 (3) NOT SHOWN 12 GA OF RATED CONTROL WIRE 12 GA 'H', L-2 - ®N 'N' NUMBER OF SPARE WIRES PULLED - 'H', L-2 - (1) LANDSCAPE CONTRACTOR TO COORDINATE ELECTRICAL POWER W/ ELECTRICAL CONTRACTOR (2) SET CONTROL VALVE PRESSURE REGULATORS AS FOLLOWS: 35 PSI FOR SPRAY VALVES / 35 PSI FOR BUBBLER VALVES / 55 PSI FOR 640 SERIES VALVES / 45 PSI FOR XP300 SERIES VALVES / 40 PSI FOR 340 SERIES VALVES THESE SETTINGS CAN BE ADJUSTED IF A DIFFERENT OPERATING PRESSURE IS DETERMINED IN THE FIELD. (3) PIPING AND VALVES ARE SHOWN IN HARDSCAPE FOR CLARITY ONLY. (4) CONTRACTOR TO LOCATE PUMP AND BACKFLOW PREVENTER IN SHRUB AREA AND SCREEN WHENEVER POSSIBLE. (5) MASTER VALVE PRESSURE REGULATOR TO BE SET TO 125 PSI OUTPUT PRESSURE. (6) CONTRACTOR TO INSTALL THRUST BLOCKS AT ALL MAINLINE CHANGES IN DIRECTION PER DETAIL 'K', SHEET LI -6. (7) FLOW SENSOR TO BE SET UP TO MONITOR MAINLINE BREAKS WITH FLOWS OVER 350 GPM. SPRINKLER LEGEND SYMBOL MANUFACTURER/MODEL # NOZZLE RAD. PSIQ FLOW (0m TQ DETAIL NOTES 3/4" T 2" SLEEVE 11-20 F TURF POP-UP SPRAY HEADS b 0 TORO 570Z-PRX-6P-5-COM Q/H 5'-6' 30 .09 PIPE .18 SLEEVE 31-40 WIRES 'A', L-2 PIPE 4" TORO 570Z-PRX-6P-8-COM Q/H 7'-8' 30 .22 6" .44 61-99 WIRES .86 'A', L-2 8" 6 e $ TORO 570Z-PRX-6P-10-COM Q/H/F 9'-10' 30 .33 SLEEVE .66 6" PIPE 1.3 'A', L-2 b TORO 570Z-PRX-6P-12-COM Q/T/H/F 11'-12' 30 .48 .64 .96 1.9 'A', L-2 6 6 0 -0' TORO 5702-PRX-6P-15-COM Q/T/H/F 13'- 15'1 30 .75 1.0 1.5 3.0 'A', L-2 SHRUB HI -POP SPRAY HEADS p TORO 570Z-PRX-12P-5-COM H 5'-6' 30 .18 1 1 'B', L-2 (1) Eh fb EB TORO 570Z-PRX-12P-8-COM Q/T/H 7'-8' 30 .22 .29 .44 .86 'B', L-2 (1) E TORO 570Z-PRX-12P-10-COM Q/T/H/TQ/F 9'-10' 30 .33 .44 .66 1.0 1.3 'B', L-2 (1) I@ TORO 570Z-PRX-12P-12-COM Q/T/H/TQ/F 11'-12' 30 1 .48.64 .96 1.5 1.9 'B', L-2 (1) ❑ TORO 570Z-PRX-12P-15-COM Q/T/H/TQ/F 13'-15' 30 .751.0 1.5 2.313.0. 'B', L-2 (1) 10 19 TORO 570Z-PRX-12P-4ST-COM EST / SST 4'x15' 30 1.431 1.88 'B', L-2 (1) TURF POP-UP ROTOR HEADS 6 OO TORO 300-00-02 02 21' 35 0.72 1.44 2.88 'C', L-2 6 ® TORO XP 300 -P -XX 05 28' 35 1.01 1.68 2.16 4.23 'C', L-2 4) 6 E) TORO XP 300 -P -XX 09 41' 50 2.10 3.27 4.19 8.38 'C', L-2 b (°j C) TORO 640 -02 -XX 40/42 55' 1 50 6.70 12.9 12.9 'C', L-2 SHRUB HI -POP ROTOR HEADS 4 4 ® TORO 300-00-02 02 21' 35 0.72 1.44 2.88 'C', L-2 4 4 8 TORO XP 300 -P -XX 05 28' 35 11.43 1.01 2.16 4.04 'C', L-2 46 6 ID TORO XP 300 -P -XX 07 1 36' 1 35 2.85 5.70 'C', L-2 TREE BUBBLERS TORO 514-20 BUBBLER F 30 1 12.401'D', L-2 1 (2) (1) IN PLANTER AREAS, USE BOTTOM INLET ONLY. (2) INSTALL (2) TWO BUBBLERS PER TREE FOR A TOTAL FLOW OF 4.80 GPM PER TREE. I 3/4 I 2' t 1 POINT OF CONNECTION NOTES: 3' 1 MAKE POINTS OF CONNECTION AS SHOWN PER FONTANA WATER STANDARDS. INSTALL BACKFLOW PREVENTERS DOWNSTREAM OF METER PER I ALL LOCAL CODES. FINAL LOCATION OF BACKFLOW DEVICES TO BE APPROVED IN THE FIELD BY THE OWNER. WHERE POSSIBLE, CONTRACTOR TO SCREEN BACKFLOW DEVICE WITH SHRUBS. INSTALL PUMP PER MANUFACTURER RECOMMENDATIONS DOWNSTREAM OF 1 I 1 BACKFLOW PREVENTER. INSTALL MASTER VALVE DOWNSTREAM OF PUMP AND WIRE TO ALL CONTROLLERS (NOTE: CONTROLLERS B1 & B2 1 WILL NEED A MASTER VALVE RELAY ALLOWING MULTIPLE CONTROLLERS TO OPERATE ONE (1) MASTER VALVE). MASTER VALVE PRESSURE REGULATOR IS TO BE SET TO OUTPUT 125 PSI MAX PRESSURE. MAXIMUM COMBINED FLOW FOR POC 'A' IS 60 GPM. MAXIMUM COMBINED 3/4- \� 3/4° 21/2• �� FLOW FOR POC 'B' IS 137 GPM MAXIMUM COMBINED FLOW FOR POC 'C' IS 44 GPM. STATIC LOW PRESSURE AT POC 'A' IS 92 PSI. 3 4' `- - 3/4' 3/4° I STATIC LOW PRESSURE AT POC B IS 90 PSI. STATIC LOW PRESSURE AT POC C IS 90 PSI. REGULATED PUMP OUTPUT PRESSURE AT 1 I ALL POC'S IS 125 PSI. X 1 1u_ 't I A' _ 1 CONTROLLER NOTE: _- -- CONTROLLER 'A', 'B', AND 'C' TO BE 32 STATION MODELS. CONTRACTOR TO PROVIDE 120V POWER TO FINAL CONTROLLERS LOCATION. 3 3j4 __ 3/4 _ I CONTRACTOR TO MAKE ALL FINAL CONNECTIONS PER LOCAL CODES. MOUNT, WIRE, AND GROUND CONTROLLERS PER MANUFACTURER'S _ DIRECTIONS. FINAL CONTROLLER LOCATION TO BE DETERMINED IN THE FIELD BY THE OWNER. I - - - - - H CONTROLLER S TO HAVE THE FOLLOWING: � 3/4 3/4`� ..X: 4'` c '��`��� (1) RAINMASTER 32 PC 'PIGTAIL' FOR REMOTE CONTROLL OPERATION. _ Ix �. ®L - ,. ®o I. (1) TORO SENSOR INPUT BOARD (SIB) MODEL 995-63 FOR FLOW SENSOR AND RAIN SHUT OFF DEVICE INPUT. I (1) TORO RADIO LINK KIT 89-7611 TO ALLOW COMMUNICATION WITH THE CENTRAL COMMAND CENTER. 54' 6' 8' S' 22' S' 14' 47'I (1) MASTER VALVE RELAY ALLOWING MULTIPLE CONTROLLERS TO OPERATE ONE MASTER VALVE. (1) CALSENSE TP -110 SURGE PROTECTION DEVICE. 25b1 26bi 27b1 (1) GROUNDING ROD. 'B' I L I ALL RADIO EQUIPMENT IS TO BE COMPATIBLE WITH VHF FREQUENCY. REMOTE CONTROL VALVES ARE TO BE RUN SIMULTANEOUSLY TO 34 1.5' 91 2" 91 2' I ACHIEVE A COMBINED FLOW OF APPROXIMATELY 325 GPM IN ORDER TO MAKE AN 8 HOUR WATERING WINDOW 5 DAYS A WEEK. sr• 1 1 CONTRACTOR TO ORDER CONTROLLER AS SOON AS POSSIBLE TO AVOID DELAYS FROM BACKORDERS. DATE ENGR. CITY DATE SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT CITY OF FONTANA, CALIFORNIA COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL �.,,�. r �9 IRRIGATION AS BUILT PLAN SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER �' �� DRAWN BY: Ty t-- tiSi natu e o �y1 AICXI THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO O _ 2-7 fn DESIGNED BY: L M/ TY BRING THEM INTO CONFORMANCE WITH CONDITIONS AND �'>9 Date '��Q DATE SUBMITTED: 3/22/04 / � ,�`CHECKED BY APPR D BY: STANDARDS IN EFFECT. CA, TY CWDG JOB NUMBER: 020638 AI)RIAi rn SCH 40 PVC SLEEVING r l 1 1/4" SLEEVE 1-4 WIRES 1/2" PIPE 1 1/2" SLEEVE 5-10 WIRES 3/4" PIPE 2" SLEEVE 11-20 WIRES 1" PIPE 2 1/2" SLEEVE 21-30 WIRES 1 1/4" PIPE 3" SLEEVE 31-40 WIRES 1 1/2" PIPE 4" SLEEVE 41-60 WIRES 2" PIPE 6" SLEEVE 61-99 WIRES 2 1/2"-3" PIPE 8" SLEEVE 100+ WIRES 4" PIPE 10" SLEEVE N/A 6" PIPE Underground Service Alert pO�oRe yo Call: TOLL FREE 1-600 227-2600 TWO WORKING DAYS BEFORE YOU DIG STATION # / CONTROLLER FLOW VALVE (GPM) SIZE PRESSURE LOSS CALCULATIONS STATION: 5A FLOW: 53 GPM LOSS THRU 2" WATER METER 2.20 PSI LOSS THRU 2" BACKFLOW 11.50 PSI, LOSS THRU 2" MASTER VALVE 1.00 PSI LOSS THRU 457' OF 2 1/2" MAIN 4.16 PSI LOSS THRU 1 GATE VALVE 1.00 PSI LOSS THRU 2" RCV VALVE 1.00 PSI LOSS THRU LATERAL LINES 2.74 PSI ELEVATION GAIN / LOSS -1.52 PSI . MISC. LOSS THRU FITTINGS (10%) 2.51 PSI TOTAL SYSTEM LOSSES 27.63 PSI PRESSURE REQUIRED AT HEAD 30.00 PSI REGULATED STATIC PRESSURE 92.00 PSI PUMP BOOST - - PSI RESIDUAL PRESSURE 34.37 PSI PRESSURE LOSS CALCULATIONS STATION:10B2 FLOW:130 GPM LOSS THRU (2) 2" WATER METER 1.40 PSI LOSS THRU 4" BACKFLOW 12.75 PSI LOSS. THRU 2 1/2" MASTER VALVE 1.00 PSI LOSS THRU 1745' OF 4" MAIN 8.90 PSI LOSS THRU 1 GATE VALVE 1.00 PSI LOSS THRU 2" RCV VALVE 2.50 PSI LOSS THRU LATERAL LINES 4.28 PSI ELEVATION GAIN / LOSS -1.08 PSI MISC. LOSS THRU FITTINGS (10%) 4.55 PSI TOTAL SYSTEM LOSSES 50.06 PSI PRESSURE REQUIRED AT HEAD 50.00 PSI REGULATED STATIC PRESSURE 90.00 PSI PUMP BOOST 125.00 PSI ' RESIDUAL PRESSURE 24.94 PSI J PRESSURE LOSS CALCULATIONS STATION:10C FLOW 33 GPM LOSS THRU 1 1/2" WATER METER 2.40 PSI LOSS THRU 2" BACKFLOW 11.75 PSI LOSS THRU 2" MASTER VALVE 1.00 PSI LOSS THRU 477' OF 2 1/2" MAIN 1.86 PSI LOSS THRU 1 GATE VALVE 1.00 PSI LOSS THRU 1 1/2" RCV VALVE 1.00 PSI LOSS THRU LATERAL LINES 0.80 PSI ELEVATION GAIN / LOSS +0.87 PSI MISC. LOSS THRU FITTINGS (10%) 1.89 PSI TOTAL SYSTEM LOSSES 20.83 PSI PRESSURE REQUIRED AT HEAD 30.00 PSI REGULATED STATIC PRESSURE 90.00 PSI PUMP BOOST - - PSI RESIDUAL PRESSURE 39.17 PSI 1-9 GPM 3/4" PIPE 10-15 GPM 1 " PIPE 16-25 GPM 1 1/4" PIPE 26-35 GPM 1 1/2" PIPE 36-50 GPM 2" PIPE 51-75 GPM 2 1/2" PIPE ; 76-120 GPM 3" PIPE " 121-190 GPM 4" PIPE SCALE: RTIN PARK DATE: 1,.-20'0 02-07-( DRAWING NO.: 2 3396 t C. F. 51152 DATE: