Loading...
HomeMy WebLinkAbout3396-23co m. 801 r 1 1-1 __ 1 - ------------------------------- 21/2 •o I E :" - _V20*1 3/4- )# E 11/4, 10' E 2-' E] 3/4 10' 04 E 20 ' - - - - - - 1 _V 0 T1 EOUIPMENT LEGEND SYMBOL MANUF-ACTUFiER/MODEL # SIZE DETAIL NOTES Ei'A' HYDROBOOST BOOSTER PUMP SYSTEM, FACTORY PRE -PIPED AND PRE -WIRED, 2 HP *Ej,#F"&'G' H TT AVAILABLE FROM BEAR STATE PUMPS 800-350-1660 CONTACT: TOM LANG F LI -7 6 0 m'A! EXISTING IRRIGATION WATER METER TO REMAIN, PROTECT IN PLACE 2p* N/A .091 g'A! TORO NETWORK 8000 (132-86-08) IRRIGATION CONTROLLER LOCATED IN A 32 STA. 'A', L-2 (1,2) 1 'A', L-2 STRONG BOX ENCLOSURE (SEE CONTROLLER NOTE) 6 (D TORO 570Z-PRX-6P-8-COM Q/H A! EXISTING FEBCO 825Y BACKFLOW PREVENTER TO REMAIN, PROTECT IN PLACE. 21' 'B', L-2 (4) PIPE CONTRACTOR TO PROVIDE NEW STRONG BOX BC-45CR ENCLOSURE. .861 'A', L-2 61-99 WIRES ' III)A' CLA-VAL 93-01 NORMALLY CLOSED PRESSURE REGULATING MASTER VALVE 2" 'E', L-2 (3) V`A! CALSENSE FM -1.258 FLOW SENSOR 1 1/4- 'E', L-2 (3) N/A EXISTING IRRIGATION PUMP - N/A - [g'B IRRIGATION WATER METERS (1 EXISTING TO REMAIN, 1 NEW) (2) 2" N/A .64 g'B1'g`B2' TORO NETWORK 8000 (132-86-08) IRRIGATION CONTROLLER LOCATED IN A 32 STA. 'A', L-2 (1,2) STRONG BOX ENCLOSURE (SEE CONTROLLER NOTE) TORO 570Z-PRX-6P-15-COM Q/T/H/F 13'-15' 30 FEBCO 880V REDUCED PRESSURE BACKFLOW PREVENTER 4" 'B', L-2 (4) 1 CLA-VAL 93-01 NORMALLY CLOSED PRESSURE REGULATING MASTER VALVE 2 1/2" 'E', L-2 (3) El TORO 570Z-PRX-12P-5-COM CALSENSE FM -2B FLOW SENSOR 20' 'E', L-2 (3) M'C' IRRIGATION WATER METER 1 1/2" N/A V. L-2 1c, TORO NETWORK 8000 (132-86-08) IRRIGATION CONTROLLER LOCATED IN A 32 STA. A7, L-2 30 .22 STRONG BOX ENCLOSURE (SEE CONTROLLER NOTE) *44 .44 .86 EEK FEBCO 825Y BACKFLOW PREVENTER LOCATED IN A STRONG BOX BC-45CR 2" 'B', L-2 (4) 30 VANDEL RESISTANT ENCLOSURE. 1.0 Cp'C, CLA-VAL 93-01 NORMALLY CLOSED PRESSURE REGULATING MASTER VALVE 201 'E, L-2 (3) 11'- 12' CALSENSE FM -1.25B FLOW SENSOR 1 1 /4- 'E', L-2 (3) 11.5 NIBCO BRONZE BALL VALVE 2" AND LESS: T-585 (BALL) 2 1/2" AND MORE: WD2000 (BUTTERFLY) LINE SIZE 'C', L-2 (3) Q/T/H/TQ/F RAINBIRD #33DLRC SERIES QUICK COUPLING VALVE 3/400 L-2 (3) 1.5- SUPERIOR 950-DWPRS REMOTE CONTROL VALVE PLAN SIZE 'E', L-2 (3) 10 151 TORO 570Z-PRX-12P-4ST-COM IRRIGATION MAINLINE: SCH. 4018" MIN. CVR) - CLS 200/315 (24" MIN. CVR) �/2" PLAN SIZE 'F', L-2 (3) UP TO 2": SCH. 40 2 -4": CLS. 315 6" AND MORE: CLS 200 'B', L-2 CLASS 200 PVC NON -PRESSURE LATERAL LINE - 12" MIN. COVER PLAN SIZE 'F', L-2 (3) 35 SCH 40 PVC IRRIGATION PIPE / WIRE SLEEVE 24" MIN. COVER SEE CHART V, L-2 (3) NOT SHOWN 12 GA OF RATED CONTROL WIRE 12 GA W, L-2 - @N N NUMBER OF SPARE WIRES PULLED 1.01 'H', L-2 2.16 (1) LANDSCAPE CONTRACTOR TO COORDINATE ELECTRICAL POWER W/ ELECTRICAL CONTRACTOR (2) SET CONTROL VALVE PRESSURE REGULATORS AS FOLLOWS: 35 PSI FOR SPRAY VALVES / 35 PSI FOR BUBBLER VALVES 55 PSI FOR 640 SERIES VALVES / 45 PSI FOR XP300 SERIES VALVES / 40 PSI FOR 340 SERIES VALVES THESE SETTINGS CAN BE ADJUSTED IF A DIFFERENT OPERATING PRESSURE IS DETERMINED IN THE FIELD. (3) PIPING AND VALVES ARE SHOWN IN HARDSCAPE FOR CLARITY ONLY. (4) CONTRACTOR TO LOCATE PUMP AND BACKFLOW PREVENTER IN SHRUB AREA AND SCREEN WHENEVER POSSIBLE. (5) MASTER VALVE PRESSURE REGULATOR TO BE SET TO 125 PSI OUTPUT PRESSURE. (6) CONTRACTOR TO INSTALL THRUST BLOCKS AT ALL MAINLINE CHANGES IN DIRECTION PER DETAIL Y, SHEET U-6. (7) FLOW SENSOR TO BE 'SET UP TO MONITOR MAINLINE BREAKS WITH FLOWS OVER 350 GPM. 99' 5 20' E 40' w4t,4w 'L82' Ati 314 ti, I SPRINKLER LEGEND , � � _j - - - __ - . - - - I A A ____+ 11/4 - - - - - - - - - - 4: 7 4 1/4' 4' q ,3/4 3/4 3/4 _73- 1 r----- =- ---- iA --------- ------------- 3 xx 3/4 1 9.0 2• 3/4 3/4 e 1 7 511 3/4 11/4 e- 7 7';, Z7' 19, 60' 4., 6 I i•..3/4 1/4 3/4 0 X 21/2* `0 42' 3/4 01 1 1/2' 2b1 14b1 V L1 01 i ii f o44 1 1 i I I 3/4' 2 5' 94' 11/4. r L _ _� 11 " t � i l II 1 6 11/4 1 00 1 Ij 3/4' 3/4• !j 1/2' SYMBOL MANUFACTURER/MODEL # NOZZLE RAD. I PSI FLOW (GPM) DETAIL NOTES Q I T I H TT TQ F TURF POP-UP SPRAY HEADS 6 0 TORO 570Z-PRX-6P-5-COM Q/H 5'-6' 30 .091 1/2" SLEEVE .18 1 1/4" 1 92.00 PSI 1 'A', L-2 SLEEVE 6 (D TORO 570Z-PRX-6P-8-COM Q/H 7'-8' 30 .221 41-60 WIRES .44 PIPE .861 'A', L-2 61-99 WIRES 6 E) TORO 570Z-PRX-6P-10-COM Q/H/F 9'-10' 30 .33 .4" .66 SLEEVE N/A 1 PIPE 4 g TORO 570Z-PRX-6P-12-COM Q/T/H/F 11'-12' 30 1.48 .64 .96 1.9 'A', L-2 6 0 TORO 570Z-PRX-6P-15-COM Q/T/H/F 13'-15' 30 .75 1.0 11.51 1 3.0 'A', L-2 SHRUB H -POP SPRAY HEADS El TORO 570Z-PRX-12P-5-COM H 5'-6' 30 .18 V. L-2 �3 Eg TORO 5702-PRX-12P-8-COM Q/T/H 7'-8' 30 .22 29 .29 *44 .44 .86 'B', L-2 E3 TORO 570Z-PRX-12P-10-COM Q/T/H/TQ/F 9'-10' 30 .33 1.0 1.3 V, L-2 TORO 570Z-PRX-12P-12-COM Q/T/H/TQ/F 11'- 12' 30 .48 $.44.66 .64 .96 11.5 1.9 V, L-2 0 TORO 570Z-PRX-12P-15-COM Q/T/H/TQ/F 13'-15' 30 .75 1.0 1.5- 2..313.01 V, L-2 10 151 TORO 570Z-PRX-12P-4ST-COM EST / SST 4'x15' 1 30 1.431 .88 'B', L-2 TURF POP-UP ROTOR HEADS 6 b 0 TORO 300-00-02 02 21' 35 0.72 1.44 12.88 'C', L-2 664 0 TORO XP 300 -P -XX 05 28' 35 1.01 1.68 2.16 14.23 'C', L-2 6 6 E) TORO XP 300 -P -XX 09 41' 50 2.10 3.27 4.19 18.38 'C', L-2 (5 0 1 TORO 640 -02 -XX 1 40/42 1 55' 1 50 16.701 112.91 112.9 1 'C', L-2 I SHRUB HI -POP ROTOR HEADS 4 0 TORO 300-00-02 02 21' 35 0.72 1.44 2.88 'C', L-2 4 0 TORO XP 300 -P -XX 05 28' 35 1.01 2.16 4.04 'C', L-2 6 0 TORO XP 300 -P -XX 07 36' 35 1.43 2.85 5.70 'C', L-2 TREE BUBBLERS TORO 514-20 BUBBLER I F 1 30 1 1 1 1 12-401 V, L -2T (2) (1) IN PLANTER AREAS, USE BOTTOM INLET ONLY. (2) INSTALL (2) TWO BUBBLERS PER TREE FOR A TOTAL FLOW OF 4.80 GPM PER TREE. 3/4 lip POINT OF CONNECTION NOTES: MAKE POINTS OF CONNECTION AS SHOWN PER FONTANA WATER STANDARDS. INSTALL BACKFLOW PREVENTERS DOWNSTREAM OF METER PER FIELD. BY THE OWNER. WHERE POSSIBLE, 3/4 A* I ALL LOCAL CODES. FINAL LOCATION OF BACKFLOW DEVICES TO BE APPROVED IN THE 2112 L4CONTRACTOR TO SCREEN BACKFLOW DEVICE WITH SHRUBS. INSTALL PUMP PER MANUFACTURER RECOMMENDATIONS DOWNSTREAM OF 11/4* BACKFLOW PREVENTER. INSTALL MASTER VALVE DOWNSTREAM OF PUMP AND WIRE TO ALL CONTROLLERS (NOTE: CONTROLLERS 81 & B2 LT -F, WILL NEED A MASTER VALVE RELAY ALLOWING MULTIPLE CONTROLLERS TO OPERATE ONE (1) MASTER VALVE). MASTER VALVE PRESSURE 3/4 REGULATOR IS TO BE SET TO OUTPUT 125 PSI MAX PRESSURE. MAXIMUM COMBINED FLOW FOR POC 'A' IS 60 GPM. MAXIMUM COMBINED 1 1 13/4• FLOW FOR POC 'B' IS 137 GPM. MAXIMUM COMBINED FLOW FOR POC 'C' IS 44 GPM. STATIC LOW PRESSURE AT POC 'A' IS 92 PSI. STATIC LOW PRESSURE AT POC V IS 90 PSI. STATIC LOW PRESSURE AT POC 'C' IS 90 PSI. REGULATED PUMP OUTPUT PRESSURE AT 21 OCS IS 125 PSI. ALL P 13bl F] I I CONTROLLER NOTE: 65 2' CONTROLLER 'A', V, AND 'C' TO BE 32 STATION MODELS. CONTRACTOR TO PROVIDE 120V POWER TO FINAL CONTROLLERS LOCATION. [e.lj 11/2' 1 I I CONTRACTOR TO MAKE ALL FINAL CONNECTIONS PER LOCAL CODES. MOUNT, WIRE, AND GROUND CONTROLLERS PER MANUFACTURER'S DIRECTIONS. FINAL 3/4 RN AL CONTROLLER LOCATION TO BE DETERMINED IN THE FIELD BY THE OWNER, 46 EACH CONTROLLER IS TO HAVE THE FOLLOWING: 12bl (1) RAINMASTER 32 PC 'PIGTAIL' FOR REMOTE CONTROLL OPERATION. 2it + 39 IF (1) TORO SENSOR INPUT BOARD (SIB) MODEL 995-63 FOR FLOW SENSOR AND RAIN SHUT OFF DEVICE INPUT. r (1) TORO RADIO LINK KIT 89-7611 TO ALLOW COMMUNICATION WITH THE CENTRAL COMMAND CENTER. LJ (1) MASTER VALVE RELAY ALLOWING MULTIPLE CONTROLLERS TO OPERATE ONE MASTER VALVE. II to (1) CALSENSE TP -110 SURGE PROTECTION DEVICE. X (1) GROUNDING ROD. 3/4 4 ALL RADIO EQUIPMENT IS TO BE COMPATIBLE WITH VHF FREQUENCY. REMOTE CONTROL VALVES ARE TO BE RUN SIMULTANEOUSLY TO - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - �4 - - - - - - - - - - - - - - - - - - ACHIEVE A COMBINED FLOW OF APPROXIMATELY 325 GPM IN ORDER TO MAKE AN 8 HOUR WATERING WINDOW 5 DAYS A WEEK. MA TCHLINE, SEE c3HEET Ll - CONTRACTOR TO ORDER CONTROLLER AS SOON AS POSSIBLE TO AVOID DELAYS FROM BACKORDERS. SCH 40 PVC SLEEVING CHART STATION: 5A FLOW: 53 GFKA 1 1/4" SLEEVE 1-4 WIRES 1/2" PIPE P E 1.00 PSI 1 1/2" SLEEVE 5-10 WIRES 3/4" P I P E PIPE 11.00 PSI 2" SLEEVE 11-20 WIRES 1" PT IP PIPE PIPE E 2.51 PSI 2 1/2" SLEEVE 21-30 WIRES 1 1/4" PIPE PIPE 92.00 PSI 3" SLEEVE 31-40 WIRES 1 1/2" PIPE ]PIPE PIPE 4" SLEEVE 41-60 WIRES 2" PIPE 6" SLEEVE 61-99 WIRES 2 1/2"-3" PIPE 8" SLEEVE . 109+ WIRES .4" SLEEVE N/A 6" PIPE STATION # CONTROLLER FLOW VALVE (GPM) SVE PRESSURE LOSS CALCULATIONS STATION: 5A FLOW: 53 GFKA LOSS THRU 2" WATER METER 2.20 PSI LOSS THRU 2" BACKFLOW 11.50 PSI LOSS THRU 2" MASTER VALVE 1.00 PSI LOSS THRU 457' OF 2 1/2" MAIN 4.16 PSI LOSS THRU 1 GATE VALVE 1.00 PSI LOSS THRU 2" RCV VALVE 11.00 PSI LOSS THRU LATERAL LINES 2.74 PSI ELEVATION GAIN / LOSS 1-1.52 PSI MISC. LOSS THRU FITTINGS (10%) 2.51 PSI TOTAL SYSTEM LOSSES 27.63 PSI PRESSURE REQUIRED AT HEAD 30.00 P81 REGULATED STATIC PRESSURE 92.00 PSI PUMP BOOST - - PSI RESIDUAL PRESSURE 34.37 PSI PRESSURE LOSS CALCULATIONS STATION: 10132 FLOW: 130 GPM LOSS THRU (2) 2- WATER METER 1.40 PSI LOSS THRU 4" BACKFLOW 12.75 PSI LOSS THRU 2 1/2- MASTER VALVE 1.00 PSI LOSS THRU 1745' OF 4" MAIN 8.90 PSI LOSS THRU 1 GATE VALVE 1.00 PSI LOSS THRU 2" RCV VALVE 2.50 PSI LOSS THRU LATERAL LINES 4.28 PSI ELEVATION GAIN / LOSS -1.08 PSI MISC. LOSS THRU FITTINGS (10%) 4.55 PSI TOTAL SYSTEM LOSSES 50.06 PSI PRESSURE REQUIRED AT HEAD 50.00 PSI REGULATED STATIC PRESSURE 90.00 PSI PUMP BOOST 125.00 PSI RESIDUAL PRESSURE 24.94 PSI PRESSURE LOSS CALCULATIONS STATION: 10C FLOW: .33 GPM LOSS THRU 1 1/2- WATER METER 2.40 PSI LOSS THRU 2" BACKFLOW 11.75 PSI LOSS THRU 2" MASTER VALVE 1.00 PSI LOSS THRU 477' OF 2 1/2- MAIN 1.86 PSI LOSS THRU 1 GATE VALVE 1.00 PSI LOSS THRU 1 1/2 RCV VALVE 1.00 PSI LOSS THRU LATERAL LINES 0.80 PSI ELEVATION GAIN / LOSS +0.87 PSI MISC. LOSS THRU FITTINGS 10% 1.89 PSI TOTAL SYSTEM LOSSES 20.83 PSI PRESSURE REQUIRED AT HEAD 30.00 PSI REGULATED STATIC PRESSURE 90.00 PSI PUMP BOOST - -PSI RESIDUAL PRESSURE 39.17 PSI 1-9 GPM 3/4" 10-15 GPM 1" 'PIPE PIPE 16-25 GPM 1 1/4" PIPE 26-35 GPM 1 1/2".PIPE 36-50 GPM 2" PIPE 51-75 GPM 2 1/2" PIPE 76-120 GPM 3" PIPE 121-190 GPM 4" PIPE REV. REVISION DESCRIPTION DATE ENGR. CITY DATE CITY OF FONTANA CALIFORNIA 4649 BQ rockton Avenue nn SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT Riverside, CA 92506 COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL IRRIGATION AS BUILT PLAN co 1VVVVV%AAA&AANVVAAA&AA SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER (909) 369-0700 TY Co NOFITH TWO WORKING DIAL DESIGNED BY: CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO BILL MAR Fax (909) 369-4039 BEFORE DAYS BEFORE (P DoLte TY YOU DIG http://www.comworksdg.com YOU DIG BRING THEM INTO CONFORMANCE WITH CONDITIONS AND CHECKED DATE SUBMITTED: 3/22/04 - BY: APPROVED BY: TOLL FREE 1-800-227-2600 TY POO 4houp A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT STANDARDS IN EFFECT. CWDG JOB NUMBER: 020638 &ITY ENGINEER R. C. E m � LI -21 SCALE: 19)-20'0" DATE: 02-07-06 DRAWING NO.: 2 33961