HomeMy WebLinkAbout3389-719
62+00
iFig 23
x
15". 95.4
PROFILE SCALES
HORIZ 1 40
» _
I j 11 I I C VERT 1 =4
63+00 64+00 65+00 66+00 67+00 68+00
V RcccrA DrAWIN - No pcwtw0(0 �IJ 3't3
SHOULD CONSTRUCTION OF THE REQUIRED
IMPROVEMENTS -NOT COMMENCE WITHIN TWO
YEARS OF THE DATE OF APPROVAL SHOWN HEREON
AND CARRIED FORTH IN A DILIGENT MANNER, THE
CITY ENGINEER MAY REQUIRE REVISIONS TO THE
REV. PLANS TO BRING THEM INTO CONFORMANCE WITH
REVISION DESCRIPTION DATE ENGR. CITY DATE STANDARDS IN EFFECT.
69+00
A.P.N. 225- 092- 5, 4 & 3
THE ENDERS FAMILY TRUST, et al
X 1606.5
ad W EC END OF CURVE PBPOLE . PAC BELL TELEPHONE POLE
o DENSE PRC POINT OF REVERSE CURVE
T VERIZON
PCC POINT OF COMPOUND CURVE CL CENTERLINE
X 1601.6 BVC BEGIN VERTICAL CURVE XXX EXISTING SPOT ELEVATION
EVC END OF VERTICAL CURVE
MVC MIDDLE OF VERTICAL CURVE SHEET MATCH LINE
TCE TEMPORARY CONSTRUCTION EASEMENT — TRACT BOUNDARY / PROPERTY LINE
AC PAVEMENT REMOVAL
0
3
rn
N
O
1n
O
d
N
N
40' 0 40 80 --- RECO D DRAW ING
1 to= 40'
o0
scale feet
L
00
U_
FEsraw"n Tr CITY OF FONTANA, CALICO IIIA � o
,??,OFES& amcm H4C
SC""''Fo�F STREET ROV ENT PLAN & PROFLE
z ®Civil Engineering •Planning Surveying •Public Works DRAWN BY: SCALE: � o
"c"
No. 37�s� 9130 Anaheim PL, Ste. 120�Rancho Cucamonga, CA 91730.909-484-9090 MPKNREF SUET AVENUE1"=40' N"
Exp. 06/30/06
* * PREPARED UNDER THE SUPERVISION OF: DESIGNED BY: STA. 6Z+OO.00 O STA. BS+18A0 DATE:
sq CiV►� ���' %�� MPKNREF LYTLE CREEK R 0 700 E/0 LYTLE CREEK RD JULY 2004 .
t=
of eA��F z
7—�y'C2 CHECKED BY. �1 BY DWG. NO.:
7
D. TODD SCHMIEDER R.C.E. 37167 DATE: RLB . CDATE: 2� 339 3 0
10 0
IMPROVEMENT PLAN REFERENCES
FUTURE STREET IMPROVEMENT PLANS PER DWG NO. 3211
PROPOSED SEWER IMPROVEMENT PLANS PER DWG NO. 3390
FUTURE SEWER IMPROVEMENT PLANS PER DWG NO. 3212
PROPOSED STORM DRAIN IMPROVEMENT PLANS PER DWG NO. 3391
FUTURE STORM DRAIN IMPROVEMENT PLANS PER DWG NO. 3213
PROPOSED TRAFFIC SIGNAL AND INTERCONNECT IMPROVEMENT PLANS
PER DWG NO. 3394
CONSTRUCTION NOTES
50
CONST 6" A.C. ON NATIVE COMPACTED TO 95% (MISC. AC PAVING)
9O
RELOCATE EXIST POWERPOLE BY SCE
25
PROTECT EXISTING IN PLACE (POWER POLE)
33
INSTALL BARBED WIRE FENCE PER CALTRANS STD A86 PER DETAIL ON SHEET 17
38
CONST. 0.10' AC OVERLAY
LEGEND
NOTE: No P�uII�G oN T}Fls SIEEEt Q
POINTHP HIGH S SEWER
CaY OTHERS
TC
T10N SD STORM DRAIN
TOP 0 CURB ELEVATION
FS
FINISHED SURFACE ELEVATION G GAS
FL
FLOW UNE ELEVATION W WATER
GB
GRADE BREAK MH MANHOLE
OC
ON CURB TP TOP OF PIPE
BC
BEGIN CURVE PP POWER POLE
ad W EC END OF CURVE PBPOLE . PAC BELL TELEPHONE POLE
o DENSE PRC POINT OF REVERSE CURVE
T VERIZON
PCC POINT OF COMPOUND CURVE CL CENTERLINE
X 1601.6 BVC BEGIN VERTICAL CURVE XXX EXISTING SPOT ELEVATION
EVC END OF VERTICAL CURVE
MVC MIDDLE OF VERTICAL CURVE SHEET MATCH LINE
TCE TEMPORARY CONSTRUCTION EASEMENT — TRACT BOUNDARY / PROPERTY LINE
AC PAVEMENT REMOVAL
0
3
rn
N
O
1n
O
d
N
N
40' 0 40 80 --- RECO D DRAW ING
1 to= 40'
o0
scale feet
L
00
U_
FEsraw"n Tr CITY OF FONTANA, CALICO IIIA � o
,??,OFES& amcm H4C
SC""''Fo�F STREET ROV ENT PLAN & PROFLE
z ®Civil Engineering •Planning Surveying •Public Works DRAWN BY: SCALE: � o
"c"
No. 37�s� 9130 Anaheim PL, Ste. 120�Rancho Cucamonga, CA 91730.909-484-9090 MPKNREF SUET AVENUE1"=40' N"
Exp. 06/30/06
* * PREPARED UNDER THE SUPERVISION OF: DESIGNED BY: STA. 6Z+OO.00 O STA. BS+18A0 DATE:
sq CiV►� ���' %�� MPKNREF LYTLE CREEK R 0 700 E/0 LYTLE CREEK RD JULY 2004 .
t=
of eA��F z
7—�y'C2 CHECKED BY. �1 BY DWG. NO.:
7
D. TODD SCHMIEDER R.C.E. 37167 DATE: RLB . CDATE: 2� 339 3 0
10 0