Loading...
HomeMy WebLinkAbout3367-11 ALL WORK SHALL BE 1N ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA STANDARD PLANS, THE CONTRACT PROVISIONS AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION ("GREEN BOOK"). ALL REFERENCE SPECIFICATIONS AND STANDARDS SHALL BE THE LATEST EDITION UNLESS OTHERWISE NOTED. 2 WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CAN NOT BE RESOLVED BY REFERENCE TO PRECEDENCE PROVISIONS IN THE "GREEN BOOK", THE CONTRACTOR SHALL IMMEDIATELY REPORT SAID CONFLICT TO THE CITY ENGINEER FOR RESOLUTION. 3 ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER. 4 CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVELOPMENT DEPARTMENT, ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK. INSPECTION COORDINATION SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY WORK IN PUBLIC RIGHT-OF-WAY WITHIN THE CITY LIMITS. CALL (909) 350-7610. 5 THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND PROCEDURES DESCRIBED IN THE STATE OF CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST NON -METRIC EDITION UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER. 6 IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS OR OTHER TRAFFIC CONTROL DEVICES AT ALL TIMES. 7 THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK FOR TRENCHES 5 FEET OR GREATER IN DEPTH FROM THE CALIFORNIA STATE DIVISION OF INDUSTRIAL SAFETY. 8 THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE (5) FEET IN DEPTH SHALL BE GUARDED BY SHORING, SLOPING OF THE GROUND OR OTHER APPROVED MEANS PURSUANT TO THE REQUIREMENTS OF THE DIVISION OF INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA. TRENCHES LESS THAN FIVE (5) FEET SHALL ALSO BE GUARDED WHEN THE POTENTIAL EXISTS FOR GROUND MOVEMENT. 9 NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT OF WAY WITHOUT OBTAINING A SEPARATE PERMIT FOR THAT PURPOSE. 10 THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION, HOWEVER, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE, IN THE FIELD, THE TRUE LOCATION AND ELEVATION OF ANY EXISTING UTILITIES, AND TO EXERCISE PROPER PRECAUTION TO AVOID DAMAGE THERETO. THE CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT AT 1-800-227-2600 TWO WORKING DAYS BEFORE EXCAVATION. 11 THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES INCLUDING, BUT NOT LIMITED TO, GAS, TELEPHONE, ELECTRIC, CABLE TELEVISION, LANDSCAPING, LANDSCAPE IRRIGATION, DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND CALTRANS. ALL UTILITY COMPANIES SHALL BE GIVEN TWO WORKING DAYS NOTICE PRIOR TO WORK AROUND THEIR FACILITIES. 12 THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES WITHOUT APPROPRIATE AGENCY AUTHORIZATION. CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE WATER COMPANY FOR VALVE OPERATION AND WATER REQUIREMENTS. 13 STATIONING REFERS TO THE CENTERLINE OF SEWER EXCEPT WHERE OTHERWISE NOTED. 14 ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE CONTRACTOR TO CONSTRUCT THE WORK TO THE PLAN GRADES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL STAKING DURING CONSTRUCTION. 15 THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONUMENT TIES OR BENCH MARKS WITHOUT PRIOR NOTIFICATION TO THE CITY ENGINEER. 16 REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING SURVEY MONUMENTS, MONUMENT TIES AND BENCH MARKS, SHALL BE DONE BY A REGISTERED CIVIL ENGINEER OR LICENSED LAND SURVEYOR. SURVEY MONUMENTS THAT WILL BE DESTROYED AS A RESULT OF THIS CONSTRUCTION SHALL BE REPLACED. THE CONTRACTOR SHALL NOTIFY THE ENGINEER ONE WEEK PRIOR TO CONSTRUCTION SO THAT TIES TO MONUMENTS CAN BE ESTABLISHED FOR LATER REPLACEMENT OF THE MONUMENT. 17 THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES. A MINIMUM 12 FOOT LANE SHALL BE MAINTAINED AT ALL TIMES IN THE CONSTRUCTION AREA FOR RESIDENTS AND EMERGENCY VEHICLES. 18 THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL, INCLUDING ADEQUATE WATERING, AT ALL TIMES. 19 THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR DEBRIS TO BE DEPOSITED ONTO PUBLIC OR PRIVATE PROPERTY ADJACENT TO THE RIGHT OF WAY DURING CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL. 20 NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR. 21 A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION. FAILURE TO OBTAIN THE REQUIRED DENSITY SHALL REQUIRE RE -WORKING OF THAT PORTION OF THE WORK UNTIL THE SPECIFIED DENSITY IS OBTAINED. 22 CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING STREET IMPROVEMENTS. UPON INSPECTION OF THE SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY NON-ERODABLE SWALES ENTERING OR LEAVING IMPROVEMENTS. 23 ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH TO MATCH EXISTING CONCRETE. 24 IF SEWER CONSTRUCTION IS TO BE DONE IN PHASES, THE CONTRACTOR SHALL PROVIDE A TERMINAL CLEANOUT AT THE PHASE BOUNDARY, NOT MORE THAN 150 FEET FROM THE DOWNSTREAM MANHOLE, SEE CITY OF FONTANA STANDARD DETAIL FOR TERMINAL CLEANOUT. Q D 0 o r N DIAL TWO WORKING BEFORE DAYS BEFORE YOU DIG YOU DIG TOLL FREE 1-800-227-2600 o A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT CL 25 SANITARY SEWER LINES SHALL BE CONSTRUCTED OF BELL AND SPIGOT OR BAND SEAL TYPE VITRIFIED CLAY PIPE (V.C.P.) EXTRA STRENGTH CLASS AND SHALL CONFORM TO THE PROVISIONS OF THE ASTM DESIGNATION C700 FOR V.C.P. 26 NO OPEN TRENCH SHALL BE ALLOWED AT THE END OF THE DAY WITHOUT PRIOR APPROVAL OF THE CITY ENGINEER. 27 SHORT VCP STUBS WITH FLEXIBLE COMPRESSION JOINTS SHALL BE USED AT MANHOLE WALLS TO ALLOW FOR MINOR DEFLECTIONS IN ALIGNMENT. 28 PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL EXPOSE EXISTING FACILITIES, AND VERIFY ELEVATION AND LOCATION OF CONNECTIONS. CITY APPROVAL OF CONNECTIONS TO EXISTING FACILITIES DOES NOT IMPLY CORRECTNESS OF ELEVATIONS OR LOCATIONS SHOWN ON THE PLANS. 29 ALL 4" HOUSE LATERALS SHALL BE INSTALLED AT A 2% MINIMUM GRADE UNLESS OTHERWISE APPROVED BY THE CITY ENGINEER. 30 TERMINATE ALL 4" HOUSE SEWER LATERALS 3 FEET INSIDE THE LOT WITH A PLUG 12' BELOW THE GROUND SURFACE. WHEN PUBLIC UTILITY EASEMENTS EXIST NEXT TO THE STREET RIGHT OF WAY, THE LATERAL SHALL TERMINATE 3 FEET INSIDE THE LOT AS MEASURED FROM THE UTILITY EASEMENT. 31 THE SEWER CONTRACTOR SHALL STAMP AN '°S" IN THE FACE OF THE CURB AT THE LOCATION OF THE SEWER LATERAL 32 IF EXISTING UTILITIES OR ANY OTHER FACILITIES CONFLICT WITH THE PROPOSED IMPROVEMENTS, THE CONTRACTOR SHALL NOTIFY THE ENGINEER AND ALL AFFECTED AGENCIES IMMEDIATELY. 33 NO CONCRETE SHALL BE PLACED UNTIL THE FORMS AND REINFORCING STEEL HAVE BEEN PLACED, INSPECTED AND APPROVED. 34 ALL UNDERGROUND UTILITIES SHALL BE INSTALLED, TESTED AND APPROVED PRIOR TO PAVING OF STREETS. 35 APPROVED SOIL STERILANT IS REQUIRED UNDER ALL NEW ASPHALT PAVEMENT PRIOR TO PLACEMENT. 36 ALL MANHOLES, CLEANOUT FRAMES, COVERS AND VALVE BOXES SHALL BE RAISED TO FINISHED GRADE BY THE PAVING CONTRACTOR UPON COMPLETION OF PAVING. 37 UPON COMPLE71ON OF CONSTRUCTION, CONTRACTOR SHALL RESTORE ALL SIGNING, STRIPING, BARRICADES, AND OTHER TRAFFIC CONTROL DEVICES TO THE SATISFACTION OF THE CITY TRAFFIC ENGINEER. 38 AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE CONTRACTOR TO THE ENGINEER OF RECORD, WHO SHALL PROVIDE RECORD DRAWINGS TO THE CITY ENGINEER. CITY OF FO—AWANA, UTILITY NOTMCAT1017 LIST CITY OF FONTANA S.B.C. INC. ATTN: CARLOS NAVARRO ATTN: JANE BLASINGHAM 8353 SIERRA AVENUE 3939 E. CORONADO STREET FONTANA, CA. 92335 ANAHEIM, CA 92807 (909) 350-6632 (714) 666-5500 SO. CALIF. GAS COMPANY UNDERGROUND SERVICE ALERT ATTN: DENNIS FREEMAN (800) 227-2600 1981 W. LUGONIA AVENUE SEWER CLEANOUT REDLANDS, CA. 92374 COMCAST ( CABLE TV ) (909) 335-7547 ATTN: JACK HAYES EMERGENCIES: (800) 427-2200 1205 DUPONT AVE. ONTARIO, CA 91761 SO. CALIF. EDISON COMPANY (909) 390-4738 300 N. PEPPER AVENUE RIALTO, CA. 92376 VERIZON 909) 820-5598 - UNDERGROUND ATTN: STEVE HOCK 909) 875-5100 - TRANSMISSION 1400 E Philips BLVD. 213) 637-1233 - PIPELINES ONTARIO, CA 91766 909) 357-6505 - DISTRIBUTION (800) 422-4133 800) 422-4133 FONTANA WATER COMPANY CRAWFORD CANYON MUTUAL WATER CO. ATTN: MICHAEL J. McGRAW ATTN: BASIL J. FABRIZIO 8440 NUEVO AVENUE (909) 463-9580 FONTANA CA. 92235 (909) 822-2201 FAX: (909) 823-5046 PEVATE EN 'S N077CE TO CO*!TRACTOR: THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES AND/OR STRUCTURES SHOWN ON THESE PLANS WERE OBTAINED BY A SEARCH OF THE AVAILABLE RECORDS. THESE LOCATIONS ARE APPROXIMATE AND SHALL BE CONFIRMED BY THE CONTRACTOR, SO THAT ANY NECESSARY ADJUSTMENT CAN BE MADE IN ALIGNMENT AND/OR GRADE OF THE PROPOSED IMPROVEMENT. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT ANY UTILITY LINES SHOWN AND ANY OTHER LINES NOT ON RECORD OR NOT SHOWN ON THESE PLANS. CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, HE WILL BE REQUIRED TO ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THE PROJECT, INCLUDING THE SAFETY OF ALL PERSONS AND PROPERTY. THIS REQUIREMENT SHALL BE MADE TO APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS. CONSTRUCTION CONTRACTOR FURTHER AGREES TO DEFEND, INDEMNIFY AND HOLD DESIGN PROFESSIONAL HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE DESIGN PROFESSIONAL. UNA-ICHAIRUSES: THE ENGINEER PREPARING THESE PLANS WILL NOT BE RESPONSIBLE FOR OR LIABLE FOR UNAUTHORIZED CHANGES TO OR USES OF THESE PLANS ALL CHANGES TO THE � �fA�C�' 011 ALL UNDERGROUND UTILITIES OR STRUCTURES REPORTED BY THE OWNER OR OTHERS AND THOSE SHOWN ON THE RECORDS EXAMINED ARE INDICATED WITH THEIR APPROXIMATE LOCATION AND EXTENT. THE OWNER, BY ACCEPTING THESE PLANS OR PROCEEDING WITH IMPROVEMENTS PURSUANT THERETO, AGREES TO ASSUME LIABILITY AND TO HOLD UNDERSIGNED HARMLESS FOR ANY DAMAGES RESULTING FROM THE EXISTENCE OF UNDERGROUND UTILITIES OR STRUCTURES NOT REPORTED TO THE UNDERSIGNED AND/OR NOT INDICATED ON THE PUBLIC RECORD EXAMINED, OR LOCATED AT VARIANCE WITH PUBLIC RECORDS EXAMINED. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT' THE UTILITIES AND/OR STRUCTURES SHOWN, AND ANY OTHER UTILITIES AND/OR STRUCTURES FOUND AT THE CONSTRUCTION SITE. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE OWNERS OF THE UTILITIES AND/OR STRUCTURES INVOLVED BEFORE STARTING WORK. INDEX MAP SCALE. 1 "=100' PLANS MUST BE IN WRITING AND MUST BE APPROVED BY THE PREPARER OF THESE PLANS. BASF OF B VGSS: BEARINGS ARE BASED ON THE SOUTH LINE OF THE SOUTHWEST ONE QUARTER OF REV. I REVISION DESCRIPTION ',ECORD D2i1 W///<F DATE I ENGR.I CITY I DATE a5 Z SECTION 36, T. 1 N., R. 6 W., S.B.B. & M. ALSO BEING THE CENTERLINE OF BASELINE AVENUE BEING NORTH 89'5821 " WEST AS SHOWN ON TRACT 16085-1, RECORDED IN MAP BOOK 282, PAGES 16-20, RECORDS OF SAN BERNARDINO COUNTY. SH01'JLD CONSTRUCTION OF P.EQUMM BEIVOWAM E-SWOMMEM NOT 00 CE VnrM PREPARED FOR: TWO YEARS OF THE DATE OF APPROVALYOUP G H0.'"ES CITY OF FONTANA BENCHMARK N0. 361. SHOWN HEREON AND CAIIEMD FORTH 94 A 10370 TRADEMARK STREET RAILROAD SPIKE IN NORTH FACE OF POWER POLE D IGENT THE CITY El's MAY 10370 CUCAMONGA, CA 91730 NO. 1536697E AT THE SOUTHWEST CORNER OF MEM REVISIONS TO THE PLANS TO TEL (909) 477-6715 BASELINE AVENUE AND SULTANA AVENUE. BRING 17M. INTO CONF02HWCE VM FAX (909) 477-6725 CONDIT[0NS MM STANDARDS IN EFFECT ELEVATION: 1365.0' s MIMPUTY MAP N.T.S. CONSTRUCTION NOTES TRUTE OAF QUA ff 1�- REMOVE SEWER TERMINAL CLEANOUT AND JOIN EXISTING 8" VCP SEWER 1 EA. Q__ CONSTRUCT 48" PRECAST CONCRETE MANHOLE PER CITY STD. DWG. NO. 112 12 EA. 3�— CONSTRUCT 4" EXTRA STRENGTH VCP SEWER LATERAL & CLEANOUT PER 2,518 LF CITY STD DWG NO. 125 (SEE GENERAL NOTE NO. 30) 82 EA. 40--- CONSTRUCT 8" EXTRA STRENGTH VCP SEWER MAIN 2,490 LF INSTALL BACKWATER CHECK VALVE 28 EA 3" MAX SIZE NATIVE SOIL, COMPACTED 95% 6" MIN. 6" MIN. 10" MAX. 10 MAX. - -Lill=r i q--77 6" MAX SIZE NAT=- SOIL, COMPACTED 90% - - - --- -- -� 1" MAX. SIZE SELECTED NATIVE BEDDING COMPACTED RECORD DOCUMENT TO 90% S. hq� These Record Documents have been prepared ® F� based on information provided by others. The � OR Design Professional has not verified the accuracyI_ No. 43976= �W EXP.6/3a1a7 and/®r completeness - O p s of this information and shall �- °- not be responsible for any errors or emissions �I ill c►vlL h may be incorporated herein as a result - r�I- . ate, 8" VCP A`' TYPICAL BEDDING FOR r VCP LESS TIM 10'DEEP NTS Prepared By: ALLARD ENGINEERING 0 L�x Civil Engineering - Land Surveying - Land Planning 8253 Sierra Avenue Fontana, California 92335 (909) 356-1815 Fax (909) 356-1795 1-14 -03 David 5. Hammer, H.C.E. 43976 Date (E)Tires 6130/2005) OQR�FESS/O� CITY OF FO TARDA, %0MIFO NI oP��o S. SEVVER IMPROVEMENT PLANS DRAWN BY: w No. 43976 m AE TRACT 0. 16403 SCALE: AS NOTED Exp. 6/30/05 * DESIGNED BY: TI�' � PAGE DA UNE, 2003 CHECKED BO D BY: -7 DRAWING NO.: 1 F0F CAL\F� DSH CITY ENGINEER R.C.E. 51152 6 Filename: M:\DWG\15908\SEWER\16403\16403-S01.DWG LEGEND EXISTING FIRE HYDRANT o - EXISTING STREET LIGHT — - — CENTER LINE —W WATER MAIN SEWER LINE W/LATERALS —Q-- SEWER MANHOLE �- SEWER CLEANOUT R/W RIGHT OF WAY PUE PUBLIC UTILITY EASEMENT 3" MAX SIZE NATIVE SOIL, COMPACTED 95% 6" MIN. 6" MIN. 10" MAX. 10 MAX. - -Lill=r i q--77 6" MAX SIZE NAT=- SOIL, COMPACTED 90% - - - --- -- -� 1" MAX. SIZE SELECTED NATIVE BEDDING COMPACTED RECORD DOCUMENT TO 90% S. hq� These Record Documents have been prepared ® F� based on information provided by others. The � OR Design Professional has not verified the accuracyI_ No. 43976= �W EXP.6/3a1a7 and/®r completeness - O p s of this information and shall �- °- not be responsible for any errors or emissions �I ill c►vlL h may be incorporated herein as a result - r�I- . ate, 8" VCP A`' TYPICAL BEDDING FOR r VCP LESS TIM 10'DEEP NTS Prepared By: ALLARD ENGINEERING 0 L�x Civil Engineering - Land Surveying - Land Planning 8253 Sierra Avenue Fontana, California 92335 (909) 356-1815 Fax (909) 356-1795 1-14 -03 David 5. Hammer, H.C.E. 43976 Date (E)Tires 6130/2005) OQR�FESS/O� CITY OF FO TARDA, %0MIFO NI oP��o S. SEVVER IMPROVEMENT PLANS DRAWN BY: w No. 43976 m AE TRACT 0. 16403 SCALE: AS NOTED Exp. 6/30/05 * DESIGNED BY: TI�' � PAGE DA UNE, 2003 CHECKED BO D BY: -7 DRAWING NO.: 1 F0F CAL\F� DSH CITY ENGINEER R.C.E. 51152 6 Filename: M:\DWG\15908\SEWER\16403\16403-S01.DWG