Loading...
HomeMy WebLinkAbout3348-12TKE JOB #: 101-03 r\\rt\,j 1 V W wo ■ cn 12 3" MAX. 4 \ w 3 12" z 3 1 7 4 12" 7 5 7 1 6 4 3 2 4 5 8 4 6 6 4 3 2 4 5 6 6" 5 1. POP-UP SPRAY HEAD PER LEGEND 1. SHRUB HI -POP SPRAY HEAD PER LEGEND 1. FINISH GRADE 2. PVC SCH 80 NIPPLE - 12" MINIMUM LENGTH 2. PVC SCH 80 NIPPLE - 12" MINIMUM LENGTH 1. FLOOD BUBBLER DRIP EMITTER PER LEGEND 2. CLEAN BACKFILL - 90% COMPACTION REQUIRED - SEE SPECS 3. PVC SCH 40 STREET ELL - TxT 3. PVC SCH 40 STREET ELL - TxT 2. PLANT MATERIAL TYPICAL) 3. NON -PRESSURE LATERAL LINE PER LEGEND 4. MARLEX STREET ELL - TxT 4. MARLEX STREET ELL - TxT 3. FINISH GRADE 4. PRESSURE SUPPLY LINE PER LEGEND 5. PVC SCH 40 LATERAL LINE FITTING 5. PVC SCH 40 LATERAL LINE FITTING 4. 112" SCH 80 NIPPLE (LENGTH AS REQUIRED) 5. CONTROL WIRES - INSTALL BELOW PRESSURE SUPPLY LINE 6. LATERAL LINE PER EQUIPMENT LEGEND 6. LATERAL LINE PER LEGEND 5. 1/2" SCH 40 PVC STREET ELL - TxT (DOUBLE SWING JOINT) 6. PROVIDE 2" OF CLEAN SAND BELOW PRESSURE MAINLINE 7. FINISH GRADE 7. FINISH GRADE 6. PVC LATERAL LINE PER LEGEND 7. 1/2" MARLEX STREET ELL - TxT (DOUBLE SWING JOINT) NOTES: NOTES: NOTES: 8. SCH 40 PVC LATERAL LINE FITTING - SxT BUNDLE AND TAPE WIRES AT 12' O.C. PIGTAIL AND LOOP USE TEFLON TAPE ON ALL MALE PIPE THREADS FOR PVC USE TEFLON TAPE ON ALL MALE PIPE THREADS FOR PVC 9. NATIVE SOIL CONTROL WIRES AT ALL 90 DEGREE CHANGES IN DIRECTION. TO PVC CONNECTIONS. SET PERIMETER HEADS 1"-2" TO PVC CONNECTIONS. SET PERIMETER HEADS 2"-6" FROM SPLICING OF WIRE RUNS IS NOT ALLOWED UNLESS APPROVED BY FROM EDGE OF WALK, WALL, OR CURB, ETC. ALL FITTINGS EDGE OF CURBS AND WALKS, AND 6"-12" FROM FIXED VERTICAL NOTES: THE CITY. 36" MIN. COVER IS REQUIRED FOR RECLAIMED WATER FOR SWING JOINTS MUST BE SAME SIZE AS INLET ON OBJECTS SUCH AS FENCES, WALLS, AND BUILDINGS, ETC, USE TEFLON TAPE ON MALE PIPE THREADS MAINLINE (WHERE APPLICABLE). INSTALL 1'xl'xl' THRUST AT ALL BASE OF HEAD. LATERAL LINE FITTING OUTLET SHALL BE BOTTOM INLET OF HEAD MUST BE USED. OF ALL PVC -TO -PVC THREADED CONNECTIONS. CHANGES IN DIRECTION OF PRESSURE MAINLINE AND AT ALL SAME SIZE AS HEAD INLET. INSTALL HEAD 1/2" ABOVE FINISHED GRADE. TERMINAL POINTS OF MAINLINE. Tui PoF-U ShrubHi-Pop Tree Trc;nc n .. d. ,a a' a _. 2 W 1 Qc Y a 1 V Y cn a 2 I I 6"-12" I 13 tr2 Ai ki I f Y , a 4 (k1@ ► k�A• t' , Z g :h r 2" 4 K..., .. ,. 1 N•............ 4 r r • t ,n. .i ;...._ _ : NOTE: USE TEFLON 4 7 TAPE ON ALL M ALE u,r,f•=,. 2" ,,, .u::. ,.::..v...... ..:. •...:...: ,`.:, _ Y :::• _. - - PIPE THREADS. pop 7 9 12 8 6 7 12'-7/v DI 2" �l VO" �xT'0 O�V0 6 Ic 00 1. HARDSCAPE (TYPICAL) '""� Oo 2. CLEAN BACKFILL - 90% COMPACTION REQUIRED 3. SAND(TYPICAL)1. i 4 10" ROUND PLASTIC VALVE BOX W/LOCKING LID 1 • 10" ROUND PLASTIC VALVE 8. PVC SCH 40 ELL - TxT 4. NON -PRESSURE LATERAL LINE SLEEVE 1. SLIP BASE SOCKET OVER END OF WIRES 2. HEAT BRAND "BV" ON LID IN 2" HIGH CHARACTERS BOX WITH LOCKING LID 9. SCH 40 PVC MAINLINE FITTING 2. HEAT BRAND "QCV" ON LID 10. PVC SCH 40 MAINLINE PIPING 5. CONTROL WIRE SLEEVE ADJACENT TO MAINLINE SLEEVE 2. STRIP WIRES APPROX. 5J8" FROM ENDS -TWIST TOGETHER 3. FINISH GRADE 4. 3/4" CRUSHED ROCK - 4" DEPTH IN 2" HIGH CHARACTERS PER EQUIPMENT LEGEND 6. PRESSURE SUPPLY LINE SLEEVE / 3. APPLY SEALER TO OUTSIDE OF SEALING PLUG AND FILL CAVITY WITH SEALER 5. BALL VALVE PER IRRIGATION PLAN NOTE: 3. FINISH GRADE 11. WALK, CURB, OR WALL, ETC. 4. PUT CRIMP END OVER WERE ENDS - CRIMP SLEEVE AND CUT OFF EXCESS WIRE USE TEFLON TAPE 6. COMMON BRICK - 4 REQUIRED 4. 3 4" CRUSHED ROCK 4" DEEP 12. 4 REBAR, 18" MINIMUM / NOTES: 5. PULL BASE SOCKET OVER END OF WIRES AS FAR AS POSSIBLE ON ALL MALE PIPE 7. SCH 40 PVC MALE ADAPTER - 2 REQUIRED 5. QUICK COUPLER PER LEGEND LENGTH SUPPORT STAKE ALL SLEEVES TO BE SCH 40 PVC. SIZE ALL SLEEVES PER SLEEVING CHART 6. PUSH SEALING PLUG INTO BASE SOCKET THREADS. B. MAINLINE PIPING PER IRRIGATION PLAN 6. PVC SCH 80 NIPPLE 13. STAINLESS STEEL CLAMP - 2 ON PLANS. EXTEND SLEEVES 12" BEYOND EDGE OF HARDSCAPE ON BOTH 7. PUSH WIRES TO END OF BASE SOCKET TO INSURE COMPLETE SEALING OF CONNECTION 'WATERPROOF 9. VALVE BOX EXTENSION(S) AS REQUIRED LENGTH AS REQUIRED * 1/2" IN TURF AREAS ENDS. RECLAIMED WATER SLEEVES TO BE MINIMUM 42"-48" DEEP (OR 8. COMPLETED WIRE CONNECTION * 1/2" IN TURF AREAS AND 2" IN SHRUB AREAS 7. PVC SCH 40 STREET ELL 2" IN SHRUB AREAS. PER WATER DISTRICT STAfJDARDS WHERE APPLICABLE. TxT sleevin,Connector Scall Valve tuck: Cou"'AingValve NOTES: TEE OFF MAINLINE TO BE 1 SAME SIZE AS LATERAL LINE EXITING VALVE. ONLY REDUCE PIPE AT A- �^ V THE VALVE. SIZE BOX 2 10 2 I Y I 3 FOR CONTROL VALVE AND BALL VALVE TO FIT WITH ADEQUATE OPERATION OF BALL VALVE HANDLE. I I 3 THERE IS TO BE ONLY 0 �� 13 4 (1) ONE VALVE PER BOX. * L _ 8 � 6 ---s 6" 12 3 60 " 12" 12 18"-24" 7 * 5 11 1 18"-24" ' '' 9 e •• v '. .. �'• ''.. h ` .• .. •. 4 f1 10 2" ^ O O 00 00 00 00 OO O 00 ._ .. .. ... -_ .. O O O �� Q10 11 6 15 1 13 4 14 7 12 11 7 8 10 5 5 10 9 vfl13 1. ELECTRIC CONTROL VALVE PER LEGEND 8- COMMON BRICK - 4 REQUIRED 1. CONTROLLER ENCLOSURE PER LEGEND AND/OR NOTES 1. ELECTRIC CONTROL VALVE PER LEGEND 2. 'JUMBO' PLASTIC VALVE BOX WITH BOLT 9- PVC LATERAL LINE PER LEGEND 2. AUTOMATIC CONTROLLER PER LEGEND 2. RECTANGULAR VALVE BOX WITH BOLT -DOWN LID DOWN LID - HEAT BRAND STATION NUM- 10. PVC SCH 4' ELL - SxS 3. FINISH GRADE 3. HEAT BRAND "MV" ON LID IN 2" HIGH CHARACTERS BER ON LID IN 2" HIGH CHARACTERS 11.' PVC MAINLINE PER LEGEND - 4. DIRECT BURIAL CONTROL WIRES TO VALVES 4. FINISH GRADE 3. FINISH GRADE 12. SCH 40 PVC MAINLINE FITTING 5. 3" PVC SWEEP ELL - EXTEND BEYOND EDGE OF BASE 5. PVC SCH 40 MALE ADAPTER 3/4" RAV E 4. PVC SCH 40 MALE ADAPTER - SIZE AS 13. 3J4'' GRAVEL - 6" DEEP 6. 6" THICK POURED CONCRETE BASE PER MANUFACTURER 6. WATERPROOF WIRE. CONNECTION W/36" EXPANSION LOOP REQUIRED -TVP. OF 2 14. I.D. TAG EQUAL 7_ SLOPE EDGE OF BASE 1% TO DRAIN AWAY FROM ENCLOSURE 7. #14 OF WIRES TO CONTROLLER MASTER VALVE OUTPUT 5. WATERPROOF WIRE CONNECTOR WITH 36" 15. SCH 80 NIPPLE - LENGTH AS 8. 120V AC POWER IN CONDUIT 8. 3/4" CRUSHED ROCK - DEEP COILED EXPANSION LOOP REQUIRED - SAME SIZE AS VALVES 9. 120V ON-OFF SWITCH WITH CONVENIENCE OUTLET 9. COMMON BRICK - 4 REQUIRED UI 6. WIRES FROM CONTROLLER 16. BALL VALVE PER EQUIPMENT LEGEND 10_ TERMINAL STRIPS FOR CONTROL WIRES 11. 5/8" 5' MIN. LENGTH COPPER GROUNDING ROD 10, PVC MAINLINE PER LEGEND - LENGTH AS REQUIRED 7. COMMON WIRE TO OTHER VALVES ON SAME SIZE AS CONTROL VALVE x 12. 11. PVC SCH 40 ELL - SxS SAME CONTROLLER EXTEND EDGE OF BASE 6" BEYOND EDGE OF ENCLOSURE 12- MAINLINE PIPING FROM POINT OF CONNECTION * 1/2" IN TURF, 2" IN PLANTER 13. GROUND CONTROLLER PER MANUFACTURER 13. MAINLINE PIPING TO CONTROL VALVES * EXTEND 4" ABOVE TOP OF BASE * 1/2" IN TURF AREAS, 2" IN SHRUB AREAS RalwnloteControlVallYre, ControlliulMASTS11 VALV. Underground Service Alert SHOULD CONSTRUCTION of THE CITY OF FONTANA, CALIFORNIA SECTION 4216/4217 OF THE GOVERNMENT g�Fo� ro CODE REQUIRES A DIG ALERT IDENTIFICATION o Go NUMBER BE ISSUED BEFORE A PERMIT TO e t y TKE ENGINEERING, INC. 4446 CENTRAS AVENUE RIVERSIDE, CA 92506 �+ STREET I PROVE ENTS REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON LANDSCAPE AND IRRIGATION PLAN DRAWN BY SCALE. EXCAVATE WILL BE VALID g (909) 680-0440 SLRRA AVENUE AND CARRIED FORTH IN A DILIGENT TMR SIERRA AVENUE AS SHOWN FOR YOUR DIG ALERT I.D. NUMBER CALL No,a4z2s Exp 6-30-05 >, ERING FAX (909) 680-0490 MANNER, THE CITY ENGINEER MAY 1-1 TO VALLEY BOULEVARD DESIGNm BY DATE: UNDERGROUND SERVICE ALERT s '-� CIVIti / O �'! 3 FROM I-10 " TO VALLEY BLV_ REQUIRE REVISIONS TO THE PLANS TO TMR AN P AND IRRIGATION DETAILS MAY 2003 TOLL FREE 1-800-227-2600 � O. CAIL- BRING THEM INTO CONFORMANCE WITH MICHAEL PATRICK THORNTON R.C.E. No. 44226 CHECKED BY: PRO BY: DATE: DRAWING No.: i2 TWO WORKING DAYS BEFORE YOU DIG EXPIRES: 6-30-05 CONDITIONS AND STANDARDS IN EFFECT. MPT REV. REVISION DESCRIPTION DATE ENGR. CITY DATE 3346 12 C EN (NEER R.C.E. No. 51152 TKE JOB #: 101-03