Loading...
HomeMy WebLinkAbout3347-1COAL hVTES 1. DIMENSIONS VARY ACCORDING TO SIZE OF CONDUIT ETC. BUT THE MINIMUM BEND RADIUS OF 3 FEET (914 mm) SHALL BE MAINTAINED ON ALL TRUNK CONDUITS CONTAINING FIBER OPTIC CABLE AND SIX TIMES THE CONDUIT DIAMETER FOR ALL OTHER CONDUITS. 2. ALL BENDS SHALL BE FACTORY BENDS. 3. CONTRACTOR SHALL ADAPT CONDUIT STUBOUTS FOR SPECIFIC PROJECT REQUIREMENTS. 4. ADDITIONAL CONDUIT ENTRANCES AS REQUIRED. 5. THE CONTRACTOR SHALL REPAIR ALL DAMAGED LANDSCAPING AND IRRIGATION TO THE SATISFACTION OF THE ENGINEER. 6. CONDUIT SHALL NOT BE INSTALLED WITHIN ONE FOOT EITHER SIDE OF WHEEL TRACKS (PARALLEL TO WHEEL TRACKS). CROSSINGS ARE ALLOWED. . 7. CONDUIT SHALL NOT BE INSTALLED DIRECTLY OVER ANY UTILITY LINE (PARALLEL WITH THE LINE). UTILITY LINE CROSSINGS ARE ALLOWED. 8. WHERE CONDUIT IS INSTALLED AND DISTURBS EXISTING STRIPING, CONTRACTOR SHALL ARRANGE AND PAY FOR STRIPING. SEE SPECIAL PROVISIONS FOR CONTRACTOR RESPONSIBILITY FOR TEMPORARY PAVEMENT MARKINGS. 9. ALL PCC SIDEWALK, DAMAGED BY THE CONTRACTORS OPERATIONS, SHALL BE SAWCUT, REMOVED AND REPLACED, TO EXISTING EXPANSION/SCRIBE JOINTS. 10. THE CONTRACTOR SHALL HAND DIG AND EXPOSE ALL UTILITY CROSSINGS PRIOR TO ANY OPEN TRENCHING OPERATIONS. THE CONTRACTOR SHALL USE EXTREME CARE WHEN EXPOSING EXISTING UTILITIES. 11. THE CONTRACTOR SHALL LOCATE, PROTECT, SHORE, BRACE, SUPPORT, AND MAINTAIN ALL EXISTING FACILITIES INCLUDING GAS, WATER, IRRIGATION, SEWER, POWER, STREET LIGHTS, TELEPHONE AND OTHER CONSTRUCTION WHICH MAY BE UNCOVERED OR OTHERWISE AFFECTED BY THE WORK. CONTRACTOR SHALL BE RESPONSIBLE FOR THE LOCATION AND PRESERVATION OF ALL SUCH FACILITIES IN THE AREA OF CONSTRUCTION, AND SHALL NOTIFY UTILITIES FORTY—EIGHT (48) HOURS IN ADVANCE OF ANY CONSTRUCTION DIG ALERT (UNDERGROUND SERVICE ALERT) SHALL BE CALLED AT 1-800-227-2600 TWO WORKING DAYS BEFORE PLANTING TREES, TRENCHING, DIGGING POST HOLES, BLASTING, GRADING, EXCAVATING, DRILLING, BORING, ETC. 12. A 12" (305 mm) VERTICAL SEPARATION BETWEEN NEW CONDUITS AND OTHER UTILITIES SHALL BE MAINTAINED AT CROSSINGS. A 3' (914 mm) MIN. HORIZONTAL SEPARATION BETWEEN NEW CONDUITS AND POWER AND WATER UTILITIES THAT RUN PARALLEL SHALL BE MAINTAINED. A 3' (914 mm) (EXCEPT WHERE NOTED) MINIMUM SEPARATION BETWEEN CONDUIT AND SANITARY SEWER AND STORM DRAINS THAT RUN PARALLEL SHALL BE MAINTAINED, UNLESS OTHERWISE APPROVED BY THE CITY. THE CONTRACTOR SHALL MAINTAIN A MINIMUM 3' (914 mm) CLEARANCE FOR ALL OTHER FACILITIES. 13. AT THE END OF EACH WORK DAY, CONDUIT CAPS SHALL BE PLACED ON ALL VACANT DUCTS. 14. THE REMOVAL, STORAGE AND REPLACEMENT OF ALL SHRUBBERY SHALL BE THE REPONSIBILITY OF THE CONTRACTOR. ALL LANDSCAPING SHALL BE RESTORED TO ORIGINAL OR BETTER CONDITION. 15. CAUTION! BURIED TRAFFIC SIGNAL LOOPS, DAMAGED OR CUT, SHALL BE REPLACED BY CONTRACTOR TO CALTRANS SPECIFICATIONS. NOTIFY CITY INSPECTOR IMMEDIATELY AND TRAFFIC DEPARTMENT TWENTY—FOUR (24) PRIOR TO ANY WORK IN THESE AREAS. 16. TRAFFIC SIGNAL CIRCUITS AND INTERCONNECT CONDUITS MAY NOT BE SHOWN. CONTRACTOR SHALL LOCATE ALL TRAFFIC SIGNAL CIRCUITS AND INTERCONNECT CONDUITS PRIOR TO ANY TRENCHING. PROVIDE 3' (914 mm) SEPARATION BETWEEN NEW CONDUITS AND ALL TRAFFIC SIGNAL AND INTERCONNECT CONDUITS AND 3' (914 mm) FROM ALL TRAFFIC SIGNAL CONTROLLERS AND PULL BOXES. ALL TRAFFIC SIGNAL AND INTERCONNECT CONDUITS SHALL BE MAINTAINED AND PROTECTED. 17. ALL NEW CONDUITS SHALL CONTAIN ONE (1) #10 GREEN STRANDED FOR FUTURE USE AS A PULL WIRE. 18. COST TO REMOVE AND REPLACE EXISTING PAVEMENT OVER UTILITY LINE TRENCHES SHALL BE INCLUDED IN THE BID PRICE. TRENCHES SHALL BE BACKFILLED AND PAVEMENT SHALL BE REPLACED PER CITY DETAIL "B" AS SHOWN ON SHEET 5. PAVEMENT SHALL BE REPLACED IN KIND (MINIMUM OF 6.5" AC ON 95% COMPACTED NATIVE) AS DETERMINED IN THE FIELD BY THE ENGINEER. ALL STRIPING AND PAVEMENT MARKINGS SHALL BE RESTORED (IN THERMOPLASTIC). 19. LOCATIONS OF CONDUIT SHOWN ON PLANS ARE SCHEMATIC IN NATURE. FINAL LOCATION OF CONDUITS SHALL BE DETERMINED AS DIRECTED BY THE ENGINEER IN THE FIELD. 20. PULL BOXES SHALL NOT BE LOCATED IN DRIVEWAYS OR OTHER LOCATIONS WHICH MAY INTERFERE WITH THE MOVEMENT OF PEOPLE OR VEHICLES. PULL BOX LOCATIONS SHALL BE ADJUSTED AS NEEDED. 21 PULL BOXES AND SPLICE VAULTS SHALL BE INSTALLED IN ACCORDANCE WITH THE DETAILS ON SHEET 6, AND INSCRIBED. "COMMUNICATIONS". 22. EXISTING UNDERGROUND UTILITIES SHOWN ARE TAKEN FROM RECORD INFORMATION TO AID THE CONTRACTOR. CONTRACTOR SHALL VERIFY LOCATION (BOTH VERTICAL AND HORIZONTAL) OF ALL EXISTING UNDER— GROUND LINES (SHOWN OR NOT) AND NOTIFY ENGINEER OF ANY DISCREPANCIES OR CONFLICTS PRIOR TO DOING STREET WORK. 23. THE CONDUITS SHALL BE COLOR CODED: ORANGE, YELLOW, RED, BLACK, BLUE AND GREEN. 23. THE 6 #19 CONDUCTORS SHALL BE INSTALLED AFTER ALL THE PROPOSED CONTROLLERS ARE IN PLACE AND SHALL BE INSTALLED FROM CONTROLLER TO CONTROLLER BY THE TRAFFIC SIGNAL CONTRACTOR. 0 w z LIJ V) Q Sheet 2 Le 19 a]' 0, :0 1 a x" I Ot 19 [#1#] FROm"McGUIRE AVENUE TO CITRUS AVENUE a �Tj � bVVIII�O/�� w Z VICINITY N.T.S. LU �LU � z z Sheet 3 N Sheet 4 Q Sheet 5 1< Q o� _ ¢ U � 3939 E. CORONADO STREET FONTANA, CA 92335 w Uj co (909) 350-6632 (714) 666-5467 SO. CALIF. GAS COMPANY CITY OF FOWM& UTULUTY NOTUFUCATUON LIST CITY OF FONTANA S.B.C. 8353 SIERRA AVENUE 3939 E. CORONADO STREET FONTANA, CA 92335 ANAHEIM, CA 92807 (909) 350-6632 (714) 666-5467 SO. CALIF. GAS COMPANY COMCAST ( CABLE TV ) 1981 W. LUGONIA AVENUE 1205 DUPONT AVE. REDLANDS, CA 92374 ONTARIO, CA 91761 (909) 390-4738 EMERGENCIES:47 (800) 427-2200 — — CRAWFORD CANYON MUTUAL WATER CO. SO. CALIF EDISON COMPANY ATTN: BASIL J. FABRIZIO 300 N. PEPPER AVENUE (909) 463-9580 RIALTO, CA 92376 909) 820-5598 — UNDERGROUND VERIZON 909) 875-5100 — TRANSMISSION 1400 E. PHILIPS BLVD. 213) 637-1233 — PIPELINES ONTARIO, CA 91766 909) 357-6223 — DISTRIBUTION FONTANA WATER COMPANY 8440 NUEVO AVENUE FONTANA, CA 92235 (909) 822-2201 FAX. (909) 823-5046 PMVATE EKG 'S VOTUCE TO C01WRACTOM THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES AND/OR STRUCTURES SHOWN ON THESE PLANS WERE OBTAINED BY A SEARCH OF THE AVAILABLE RECORDS. THESE LOCATIONS ARE APPROXIMATE AND SHALL BE CONFIRMED BY THE CONTRACTOR, SO THAT ANY NECESSARY ADJUSTMENT CAN BE MADE IN ALIGNMENT AND/OR GRADE OF THE PROPOSED IMPROVEMENT. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT ANY UTILITY LINES SHOWN AND ANY OTHER LINES NOT ON RECORD OR NOT SHOWN ON THESE PLANS. CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, HE WILL BE REQUIRED TO ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THE PROJECT, INCLUDING THE SAFETY OF ALL PERSONS AND PROPERTY. THIS REQUIREMENT SHALL BE MADE TO APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS. CONSTRUCTION CONTRACTOR FURTHER AGREES TO DEFEND, INDEMNIFY AND HOLD DESIGN PROFESSIONAL HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE DESIGN PROFESSIONAL. MAUTHOEUM CIMGES AND USES: THE ENGINEER PREPARING THESE PLANS WILL NOT BE RESPONSIBLE FOR OR LIABLE FOR, UNAUTHORIZED CHANGES TO OR USES OF THESE PLANS. ALL CHANGES TO THE PLANS MUST BE IN WRITING AND MUST BE APPROVED BY THE PREPARER OF THESE PLANS. 8119,mWEX TITLE SHEET SHEET 1 BASELINE AVENUE SHEET 2 BASELINE AVENUE SHEET 3 BASELINE AVENUE SHEET 4 BASELINE AVENUE AND DETATILS SHEET 5 SPLICE VAULT DETAILS SHEET 6 LEGEND 22,000 LUMEN, 200 WATT H.P.S.V. 120 LAMP ON 30' MARBELITE POLE OR APPROVED EQUAL (INSTALLED BY OTHERS) ¢w o' Ldw = c� ►►z¢J� go oW �_ BASELINE AVENUE 11VDEX MAP SCALE. 1`_400' These Record Documents have been prepared based on information provided by others. The Design Professional has not verified the accuracy and/or completeness of this information and shall not be responsible for any errors or omissions which may be incorporated herein as a result CONSTRUCTION NOTES FURNISH AND INSTALL SIX (6) 1 1/2" HIGH DENSITY POLYETHYLENE (HDPE) COMMUNICATION CONDUITS PER DETAIL A OR B��SHOWN ON SHEET 5. FURNISH AND INSTALL ONE (1) 110 GREEN STRANDED IN ALL CONDUITS FOR FUTURE USE. O2 --- FURNISH AND INSTALL SPLICE VAULT (P48) WITH SPLIT LID. SPLICE VAULT COVER TO BE INSCRIBED "COMMUNICATIONS". SEE SPLICE VAULT DETAIL ON SHEET 6. a3 —INSTALL 4" PVC—SCH 40 (GRAY) SLEEVE WITH END CAPS, 30" (MIN.) BELOW FINISH SURFACE. SAWCUT, REMOVE AND REPLACE EXISTING A.C. PAVEMENT PER CITY STANDARD DWG. NO. 131 GRIND EXISTING A. C. PAVEMENT 0.10' MIN. AND OVERLAY PER CITY STANDARD DWG. NO. 131 a6 — FURNISH AND INSTALL ONE(1) 6419 SIC CONDUTOR IN THE ORANGE CONDUIT. (SEE SPECIFICATIONS, SPECIAL PR ISION SECTION E FOR INSTALLATION SPECIFICATIONS). O7 — FURNISH AND INSTALL 2" METAL TRAFFIC SIGNAL CONDUIT FROM SPLICE VAULT TO CONTROLLER. EXISTING STREET LIGHTS SIGNALIZED STREET LIGHT SPLICE VAULT ® CONTROLLER PANEL (PER PLAN) CONDUIT BUNDLE 4" PVC SCH. 40 SLEEVE — — PROPOSED CONDUIT PER TRAFFIC SIGNAL PLAN ¢w o' Ldw = c� ►►z¢J� go oW �_ BASELINE AVENUE 11VDEX MAP SCALE. 1`_400' These Record Documents have been prepared based on information provided by others. The Design Professional has not verified the accuracy and/or completeness of this information and shall not be responsible for any errors or omissions which may be incorporated herein as a result CONSTRUCTION NOTES FURNISH AND INSTALL SIX (6) 1 1/2" HIGH DENSITY POLYETHYLENE (HDPE) COMMUNICATION CONDUITS PER DETAIL A OR B��SHOWN ON SHEET 5. FURNISH AND INSTALL ONE (1) 110 GREEN STRANDED IN ALL CONDUITS FOR FUTURE USE. O2 --- FURNISH AND INSTALL SPLICE VAULT (P48) WITH SPLIT LID. SPLICE VAULT COVER TO BE INSCRIBED "COMMUNICATIONS". SEE SPLICE VAULT DETAIL ON SHEET 6. a3 —INSTALL 4" PVC—SCH 40 (GRAY) SLEEVE WITH END CAPS, 30" (MIN.) BELOW FINISH SURFACE. SAWCUT, REMOVE AND REPLACE EXISTING A.C. PAVEMENT PER CITY STANDARD DWG. NO. 131 GRIND EXISTING A. C. PAVEMENT 0.10' MIN. AND OVERLAY PER CITY STANDARD DWG. NO. 131 a6 — FURNISH AND INSTALL ONE(1) 6419 SIC CONDUTOR IN THE ORANGE CONDUIT. (SEE SPECIFICATIONS, SPECIAL PR ISION SECTION E FOR INSTALLATION SPECIFICATIONS). O7 — FURNISH AND INSTALL 2" METAL TRAFFIC SIGNAL CONDUIT FROM SPLICE VAULT TO CONTROLLER.