HomeMy WebLinkAbout3347-1COAL hVTES
1. DIMENSIONS VARY ACCORDING TO SIZE OF CONDUIT ETC.
BUT THE MINIMUM BEND RADIUS OF 3 FEET (914 mm)
SHALL BE MAINTAINED ON ALL TRUNK CONDUITS CONTAINING
FIBER OPTIC CABLE AND SIX TIMES THE CONDUIT DIAMETER FOR
ALL OTHER CONDUITS.
2. ALL BENDS SHALL BE FACTORY BENDS.
3. CONTRACTOR SHALL ADAPT CONDUIT STUBOUTS FOR SPECIFIC PROJECT
REQUIREMENTS.
4. ADDITIONAL CONDUIT ENTRANCES AS REQUIRED.
5. THE CONTRACTOR SHALL REPAIR ALL DAMAGED LANDSCAPING AND
IRRIGATION TO THE SATISFACTION OF THE ENGINEER.
6. CONDUIT SHALL NOT BE INSTALLED WITHIN ONE FOOT EITHER SIDE OF
WHEEL TRACKS (PARALLEL TO WHEEL TRACKS). CROSSINGS ARE ALLOWED. .
7. CONDUIT SHALL NOT BE INSTALLED DIRECTLY OVER ANY UTILITY LINE
(PARALLEL WITH THE LINE). UTILITY LINE CROSSINGS ARE ALLOWED.
8. WHERE CONDUIT IS INSTALLED AND DISTURBS EXISTING STRIPING,
CONTRACTOR SHALL ARRANGE AND PAY FOR STRIPING. SEE SPECIAL
PROVISIONS FOR CONTRACTOR RESPONSIBILITY FOR TEMPORARY PAVEMENT
MARKINGS.
9. ALL PCC SIDEWALK, DAMAGED BY THE CONTRACTORS OPERATIONS, SHALL BE
SAWCUT, REMOVED AND REPLACED, TO EXISTING EXPANSION/SCRIBE JOINTS.
10. THE CONTRACTOR SHALL HAND DIG AND EXPOSE ALL UTILITY CROSSINGS PRIOR
TO ANY OPEN TRENCHING OPERATIONS. THE CONTRACTOR SHALL USE EXTREME
CARE WHEN EXPOSING EXISTING UTILITIES.
11. THE CONTRACTOR SHALL LOCATE, PROTECT, SHORE, BRACE, SUPPORT, AND
MAINTAIN ALL EXISTING FACILITIES INCLUDING GAS, WATER, IRRIGATION, SEWER,
POWER, STREET LIGHTS, TELEPHONE AND OTHER CONSTRUCTION WHICH MAY BE
UNCOVERED OR OTHERWISE AFFECTED BY THE WORK. CONTRACTOR SHALL BE
RESPONSIBLE FOR THE LOCATION AND PRESERVATION OF ALL SUCH FACILITIES
IN THE AREA OF CONSTRUCTION, AND SHALL NOTIFY UTILITIES FORTY—EIGHT (48)
HOURS IN ADVANCE OF ANY CONSTRUCTION
DIG ALERT (UNDERGROUND SERVICE ALERT) SHALL BE CALLED AT
1-800-227-2600 TWO WORKING DAYS BEFORE PLANTING TREES, TRENCHING,
DIGGING POST HOLES, BLASTING, GRADING, EXCAVATING, DRILLING, BORING, ETC.
12. A 12" (305 mm) VERTICAL SEPARATION BETWEEN NEW CONDUITS AND OTHER
UTILITIES SHALL BE MAINTAINED AT CROSSINGS. A 3' (914 mm) MIN. HORIZONTAL
SEPARATION BETWEEN NEW CONDUITS AND POWER AND WATER UTILITIES THAT RUN
PARALLEL SHALL BE MAINTAINED. A 3' (914 mm) (EXCEPT WHERE NOTED)
MINIMUM SEPARATION BETWEEN CONDUIT AND SANITARY SEWER AND STORM DRAINS
THAT RUN PARALLEL SHALL BE MAINTAINED, UNLESS OTHERWISE APPROVED BY THE
CITY. THE CONTRACTOR SHALL MAINTAIN A MINIMUM 3' (914 mm) CLEARANCE
FOR ALL OTHER FACILITIES.
13. AT THE END OF EACH WORK DAY, CONDUIT CAPS SHALL BE PLACED ON ALL VACANT
DUCTS.
14. THE REMOVAL, STORAGE AND REPLACEMENT OF ALL SHRUBBERY SHALL BE THE
REPONSIBILITY OF THE CONTRACTOR. ALL LANDSCAPING SHALL BE RESTORED
TO ORIGINAL OR BETTER CONDITION.
15. CAUTION! BURIED TRAFFIC SIGNAL LOOPS, DAMAGED OR CUT, SHALL BE REPLACED
BY CONTRACTOR TO CALTRANS SPECIFICATIONS. NOTIFY CITY INSPECTOR IMMEDIATELY
AND TRAFFIC DEPARTMENT TWENTY—FOUR (24) PRIOR TO ANY WORK IN THESE AREAS.
16. TRAFFIC SIGNAL CIRCUITS AND INTERCONNECT CONDUITS MAY NOT BE SHOWN.
CONTRACTOR SHALL LOCATE ALL TRAFFIC SIGNAL CIRCUITS AND INTERCONNECT
CONDUITS PRIOR TO ANY TRENCHING. PROVIDE 3' (914 mm)
SEPARATION BETWEEN NEW CONDUITS AND ALL TRAFFIC SIGNAL AND INTERCONNECT
CONDUITS AND 3' (914 mm) FROM ALL TRAFFIC SIGNAL CONTROLLERS AND PULL
BOXES. ALL TRAFFIC SIGNAL AND INTERCONNECT CONDUITS SHALL BE MAINTAINED
AND PROTECTED.
17. ALL NEW CONDUITS SHALL CONTAIN ONE (1) #10 GREEN STRANDED FOR
FUTURE USE AS A PULL WIRE.
18. COST TO REMOVE AND REPLACE EXISTING PAVEMENT OVER UTILITY LINE
TRENCHES SHALL BE INCLUDED IN THE BID PRICE. TRENCHES SHALL BE
BACKFILLED AND PAVEMENT SHALL BE REPLACED PER CITY DETAIL "B" AS SHOWN
ON SHEET 5. PAVEMENT SHALL BE REPLACED IN KIND (MINIMUM OF 6.5" AC
ON 95% COMPACTED NATIVE) AS DETERMINED IN THE FIELD BY THE ENGINEER.
ALL STRIPING AND PAVEMENT MARKINGS SHALL BE RESTORED (IN THERMOPLASTIC).
19. LOCATIONS OF CONDUIT SHOWN ON PLANS ARE SCHEMATIC IN NATURE.
FINAL LOCATION OF CONDUITS SHALL BE DETERMINED AS DIRECTED BY
THE ENGINEER IN THE FIELD.
20. PULL BOXES SHALL NOT BE LOCATED IN DRIVEWAYS OR OTHER LOCATIONS
WHICH MAY INTERFERE WITH THE MOVEMENT OF PEOPLE OR VEHICLES. PULL
BOX LOCATIONS SHALL BE ADJUSTED AS NEEDED.
21 PULL BOXES AND SPLICE VAULTS SHALL BE INSTALLED IN ACCORDANCE WITH
THE DETAILS ON SHEET 6, AND INSCRIBED. "COMMUNICATIONS".
22. EXISTING UNDERGROUND UTILITIES SHOWN ARE TAKEN FROM RECORD
INFORMATION TO AID THE CONTRACTOR. CONTRACTOR SHALL VERIFY
LOCATION (BOTH VERTICAL AND HORIZONTAL) OF ALL EXISTING UNDER—
GROUND LINES (SHOWN OR NOT) AND NOTIFY ENGINEER OF ANY
DISCREPANCIES OR CONFLICTS PRIOR TO DOING STREET WORK.
23. THE CONDUITS SHALL BE COLOR CODED: ORANGE, YELLOW, RED, BLACK,
BLUE AND GREEN.
23. THE 6 #19 CONDUCTORS SHALL BE INSTALLED AFTER ALL THE PROPOSED
CONTROLLERS ARE IN PLACE AND SHALL BE INSTALLED FROM CONTROLLER
TO CONTROLLER BY THE TRAFFIC SIGNAL CONTRACTOR.
0
w
z
LIJ
V)
Q Sheet 2
Le 19 a]' 0, :0 1 a x" I Ot 19 [#1#]
FROm"McGUIRE AVENUE TO CITRUS AVENUE
a
�Tj � bVVIII�O/��
w
Z
VICINITY
N.T.S.
LU
�LU
� z z
Sheet 3 N Sheet 4 Q Sheet 5 1<
Q
o� _
¢ U
�
3939 E. CORONADO STREET
FONTANA, CA 92335
w
Uj
co
(909) 350-6632
(714) 666-5467
SO. CALIF. GAS COMPANY
CITY OF FOWM& UTULUTY NOTUFUCATUON LIST
CITY OF FONTANA
S.B.C.
8353 SIERRA AVENUE
3939 E. CORONADO STREET
FONTANA, CA 92335
ANAHEIM, CA 92807
(909) 350-6632
(714) 666-5467
SO. CALIF. GAS COMPANY
COMCAST ( CABLE TV )
1981 W. LUGONIA AVENUE
1205 DUPONT AVE.
REDLANDS, CA 92374
ONTARIO, CA 91761
(909) 390-4738
EMERGENCIES:47 (800) 427-2200
— —
CRAWFORD CANYON MUTUAL WATER CO.
SO. CALIF EDISON COMPANY
ATTN: BASIL J. FABRIZIO
300 N. PEPPER AVENUE
(909) 463-9580
RIALTO, CA 92376
909) 820-5598 — UNDERGROUND
VERIZON
909) 875-5100 — TRANSMISSION
1400 E. PHILIPS BLVD.
213) 637-1233 — PIPELINES
ONTARIO, CA 91766
909) 357-6223 — DISTRIBUTION
FONTANA WATER COMPANY
8440 NUEVO AVENUE
FONTANA, CA 92235
(909) 822-2201
FAX. (909) 823-5046
PMVATE EKG 'S VOTUCE TO C01WRACTOM
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES AND/OR STRUCTURES
SHOWN ON THESE PLANS WERE OBTAINED BY A SEARCH OF THE AVAILABLE RECORDS.
THESE LOCATIONS ARE APPROXIMATE AND SHALL BE CONFIRMED BY THE CONTRACTOR,
SO THAT ANY NECESSARY ADJUSTMENT CAN BE MADE IN ALIGNMENT AND/OR GRADE
OF THE PROPOSED IMPROVEMENT. THE CONTRACTOR IS REQUIRED TO TAKE DUE
PRECAUTIONARY MEASURES TO PROTECT ANY UTILITY LINES SHOWN AND ANY OTHER
LINES NOT ON RECORD OR NOT SHOWN ON THESE PLANS.
CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED
CONSTRUCTION PRACTICES, HE WILL BE REQUIRED TO ASSUME
SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE
OF CONSTRUCTION OF THE PROJECT, INCLUDING THE SAFETY OF ALL PERSONS AND
PROPERTY. THIS REQUIREMENT SHALL BE MADE TO APPLY CONTINUOUSLY AND
NOT BE LIMITED TO NORMAL WORKING HOURS. CONSTRUCTION CONTRACTOR FURTHER
AGREES TO DEFEND, INDEMNIFY AND HOLD DESIGN PROFESSIONAL HARMLESS FROM ANY
AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF
WORK ON THIS PROJECT, EXCEPTING LIABILITY ARISING FROM THE SOLE NEGLIGENCE
OF THE DESIGN PROFESSIONAL.
MAUTHOEUM CIMGES AND USES:
THE ENGINEER PREPARING THESE PLANS WILL NOT BE RESPONSIBLE FOR OR LIABLE
FOR, UNAUTHORIZED CHANGES TO OR USES OF THESE PLANS. ALL CHANGES TO THE
PLANS MUST BE IN WRITING AND MUST BE APPROVED BY THE PREPARER OF THESE PLANS.
8119,mWEX
TITLE SHEET SHEET 1
BASELINE AVENUE SHEET 2
BASELINE AVENUE SHEET 3
BASELINE AVENUE SHEET 4
BASELINE AVENUE AND DETATILS SHEET 5
SPLICE VAULT DETAILS SHEET 6
LEGEND
22,000 LUMEN, 200 WATT H.P.S.V. 120 LAMP
ON 30' MARBELITE POLE OR APPROVED EQUAL
(INSTALLED BY OTHERS)
¢w o' Ldw = c�
►►z¢J� go oW �_
BASELINE AVENUE
11VDEX MAP
SCALE. 1`_400'
These Record Documents have been prepared
based on information provided by others. The
Design Professional has not verified the accuracy
and/or completeness of this information and shall
not be responsible for any errors or omissions
which may be incorporated herein as a result
CONSTRUCTION NOTES
FURNISH AND INSTALL SIX (6) 1 1/2" HIGH DENSITY POLYETHYLENE (HDPE) COMMUNICATION
CONDUITS PER DETAIL A OR B��SHOWN ON SHEET 5. FURNISH AND INSTALL ONE (1)
110 GREEN STRANDED IN ALL CONDUITS FOR FUTURE USE.
O2 --- FURNISH AND INSTALL SPLICE VAULT (P48) WITH SPLIT LID. SPLICE VAULT COVER TO BE
INSCRIBED "COMMUNICATIONS". SEE SPLICE VAULT DETAIL ON SHEET 6.
a3 —INSTALL 4" PVC—SCH 40 (GRAY) SLEEVE WITH END CAPS, 30" (MIN.) BELOW FINISH SURFACE.
SAWCUT, REMOVE AND REPLACE EXISTING A.C. PAVEMENT PER CITY STANDARD DWG. NO. 131
GRIND EXISTING A. C. PAVEMENT 0.10' MIN. AND OVERLAY PER CITY STANDARD DWG. NO. 131
a6 — FURNISH AND INSTALL ONE(1) 6419 SIC CONDUTOR IN THE ORANGE CONDUIT.
(SEE SPECIFICATIONS, SPECIAL PR ISION SECTION E FOR INSTALLATION SPECIFICATIONS).
O7 — FURNISH AND INSTALL 2" METAL TRAFFIC SIGNAL CONDUIT
FROM SPLICE VAULT TO CONTROLLER.
EXISTING STREET LIGHTS
SIGNALIZED STREET LIGHT
SPLICE VAULT
®
CONTROLLER PANEL (PER PLAN)
CONDUIT BUNDLE
4" PVC SCH. 40 SLEEVE
— —
PROPOSED CONDUIT PER TRAFFIC SIGNAL PLAN
¢w o' Ldw = c�
►►z¢J� go oW �_
BASELINE AVENUE
11VDEX MAP
SCALE. 1`_400'
These Record Documents have been prepared
based on information provided by others. The
Design Professional has not verified the accuracy
and/or completeness of this information and shall
not be responsible for any errors or omissions
which may be incorporated herein as a result
CONSTRUCTION NOTES
FURNISH AND INSTALL SIX (6) 1 1/2" HIGH DENSITY POLYETHYLENE (HDPE) COMMUNICATION
CONDUITS PER DETAIL A OR B��SHOWN ON SHEET 5. FURNISH AND INSTALL ONE (1)
110 GREEN STRANDED IN ALL CONDUITS FOR FUTURE USE.
O2 --- FURNISH AND INSTALL SPLICE VAULT (P48) WITH SPLIT LID. SPLICE VAULT COVER TO BE
INSCRIBED "COMMUNICATIONS". SEE SPLICE VAULT DETAIL ON SHEET 6.
a3 —INSTALL 4" PVC—SCH 40 (GRAY) SLEEVE WITH END CAPS, 30" (MIN.) BELOW FINISH SURFACE.
SAWCUT, REMOVE AND REPLACE EXISTING A.C. PAVEMENT PER CITY STANDARD DWG. NO. 131
GRIND EXISTING A. C. PAVEMENT 0.10' MIN. AND OVERLAY PER CITY STANDARD DWG. NO. 131
a6 — FURNISH AND INSTALL ONE(1) 6419 SIC CONDUTOR IN THE ORANGE CONDUIT.
(SEE SPECIFICATIONS, SPECIAL PR ISION SECTION E FOR INSTALLATION SPECIFICATIONS).
O7 — FURNISH AND INSTALL 2" METAL TRAFFIC SIGNAL CONDUIT
FROM SPLICE VAULT TO CONTROLLER.