HomeMy WebLinkAbout3201-2w
CARAWAY CT
12
0
I
1
1 2 13 3 .Y
ZI
" 7 - "•
14
13.17 •i <.`.9'1
10+00.00 CARAWAY CT. ST. STA
2 1 S. cRnml 1 S
=12+44.35 VILLAGE DRIVE ST. STA 106.36
CA 9r,65
15 ��, f~l" C.
(714) 9700
's
JV
632 'S
IA
4+50.97 CARAWAY CT
6, 9~CARq- -----------
INA Y COURT � - �x 3
Y. 32
10 s 94 2 p51 29.32' 1.32, 9>
9 7 0 ' } $ 31 j 'rxo 40' 80' 120' 160'
4 4"
1.
2 3"
5 SCALE 1"=40'
'no8
6
UNDERGROUND SERVICE ALERT
O�FORE yoG CALL TOLL FREE
'Ilk0 1-800
227-2600
TWO WORKING DAYS
2+60.44 CARAWAY -9i
1+82.33 VILLAGE DRIVE
(t SMH NO. 2
CARAWAY COURT
n ELMAN
ENG TT-T1P-E1P,S
221 S GLASSELL ST ORANGE, CA 92866
(714) 744-9700 FAX (714) 744-9312
SEW X-ING SD
2+70.44 CARAWAY CT
=12+39.39 VILLAGE DRIVE ST. STA
933.88 BOT. SD
932.26 TOP SEW.
R-LATEf i,
SEWER
1
3+28.51
CARAWAY
COURT
NONE
2
4+27.37
CARAWAY
COURT
NONE
3
4+44.97
CARAWAY
COURT
NONE
4
4+03.68
CARAWAY
COURT
NONE
5
3+77.80
CARAWAY
COURT
NONE
6
3+32.20
CARAWAY
COURT
NONE
7
2+06.73
CARAWAY
COURT
NONE
8
1+73.63
CARAWAY
COURT
NONE
9
1+35.64
CARAWAY
COURT
NONE
10
0+79.42
CARAWAY
COURT
NONE
11
0+44.89
CARAWAY
COURT
NONE
12
0+06.00
CARAWAY
COURT
NONE
13
0+07.00
CARAWAY
COURT
NONE
14
0+45.29
CARAWAY
COURT
NONE
15
1+53.25
CARAWAY
COURT
NONE
PC- Ft
Ell
Ills
64.75'
ELEVATION P10 R TO START
'
Cli SS io PER
4 1 2 3
0+27.42 VILLAGE DRIVE ~
=10+85.75 VILLAGE DRIVE ST. STA.
�0 932.86 BOT. SD J Os
928.59 TOP SEW. J
1 2+60.44 CARAWAY CT Qa
0+00.00 VILLAGE DRIVE =1+82.33 VILLAGE DRIVE
-� EXIST. SMH #I t SMH NO. 2
93.37' I U
I/ILLAGE DRIVE
------------------
_ --- ew-------
_-____
114.20'
DUST. 12° D.I.P.- fps , �ti
SEWER PER CITY `� t
OF FONTANA DWG
NO. 1583, SHEET 3.
10+00.00 CARAWAY CT ST. STA.
=12+44.35 VILLAGE DRIVE ST. STA
VILLAGE DRIVE
CONSTRUCTION NOTES
INSTALL STANDARD MANHOLE PER CITY OF FONTANA STANDARD DETAIL 112.
�2 INSTALL 8" VITRIFIED CLAY PIPE EXTRA STRENGTH
PER CITY OF FONTANA STANDARDS AND SPECIFICATIONS
OINSTALL 4" VITRIFIED CLAY EXTRA STRENGTH SEWER LATERAL
PER CITY OF FONTANA STANDARD DETAIL 125. INSTALL SEWER
CLEANOUT BOX PER CITY OF FONTANA STD DETAIL 125A FOR
CONCRETE AREAS AND 125B FOR LANDSCAPE AREAS.
-1-
BENCHMARK U
BENCHMARK: 918.40 DIAL TW❑ WORKING
BEFORE
Y❑UBEFORE
SPIKE ON POWER POLE #674320E AT INTERSECTION B❑U ❑DIG DAYS
JURUPA AVE AND MULBERRY AVE TOLL FREE 1-800-227-2600
A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT
TI
CURVE TABLE
Q�pvESS/0�4
�o ZHI��
N 'w �� `=
No. 25742 m
Exp. 12-31-05
*'�,9 C/V11. ��Q�
�F Foy
OFF CAt
#
A
R L
T
A
51°11'40'
255.00' 227.85'
122.16'
B
11014'27'
805.00' 157.93'
79,22'
C
8°01'20`
1 995,00' 1 139.32'
1 69,77'
BENCHMARK U
BENCHMARK: 918.40 DIAL TW❑ WORKING
BEFORE
Y❑UBEFORE
SPIKE ON POWER POLE #674320E AT INTERSECTION B❑U ❑DIG DAYS
JURUPA AVE AND MULBERRY AVE TOLL FREE 1-800-227-2600
A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT
TI
REVISION DESCRIPTION DATE ENGR. CITY DATE
SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT
COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL
SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER,
THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO
BRING THEM INTO CONFORMANCE WITH CONDITIONS AND
RE7�Ro DRFtc►�iNb 3: D° STANDARDS IN EFFECT.
Q�pvESS/0�4
�o ZHI��
N 'w �� `=
No. 25742 m
Exp. 12-31-05
*'�,9 C/V11. ��Q�
�F Foy
OFF CAt
Prepared Under The Supervision Of :
DENS THIELMANN
R.C.E. No. 25742
EXP. DATE
12/31/05
- Date : P-1I-eL
U
BENCHMARK U
BENCHMARK: 918.40 DIAL TW❑ WORKING
BEFORE
Y❑UBEFORE
SPIKE ON POWER POLE #674320E AT INTERSECTION B❑U ❑DIG DAYS
JURUPA AVE AND MULBERRY AVE TOLL FREE 1-800-227-2600
A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT
REV.
REVISION DESCRIPTION DATE ENGR. CITY DATE
SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT
COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL
SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER,
THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO
BRING THEM INTO CONFORMANCE WITH CONDITIONS AND
RE7�Ro DRFtc►�iNb 3: D° STANDARDS IN EFFECT.
Q�pvESS/0�4
�o ZHI��
N 'w �� `=
No. 25742 m
Exp. 12-31-05
*'�,9 C/V11. ��Q�
�F Foy
OFF CAt
Prepared Under The Supervision Of :
DENS THIELMANN
R.C.E. No. 25742
EXP. DATE
12/31/05
- Date : P-1I-eL
CITY OF FONTANA, CALIFORNIA
SOUTHRIDGE VILLAGE
DRAWN BY
S.Z.
SEINER IMPROVEMENT PLANS
TRACT 16119DATE-
CARAWAY CT
SCALE:
AS SHOWN
DATE:
7/17/02
DESIGNED BY
J�
CHECKED BY
APPRO BY:
- C �
DRAWING NO.:
3201
2
2
CI Y ENGINEER R.C.E. 51152 DATE:.