Loading...
HomeMy WebLinkAbout3188-1CONDUCTOR TABLE L CIRCUIT OR POLE MAST ARMS LUMINAIRE PED PUSH BT. SIGNAL MOUNTING S.N.S. PLACEMENT REMARKS C TYPE HT. SIG. LUM. H.P.S.V. TYPE PHASE QUAD VEHICLE PED. MESSAGE A B I M �Muo_ E E ENE E E M M 0 E E E MUM MVA 0 E MF__ LU - M - I - NAIRE VIDEO CABLE VIDEO SVC. OPTICOM CABLE CO NDUIT SIZE ' � � "A° ' /v Curb/Berm ~ � �in or edge ofshoulder ^ /�� | | " , '. ' / �-0�-� | ~� � ����N� | I< _' / ' \ ' {' MAST ARM '/^ /»« LINE � BCR Y POLE SCHEDULE L STANDARD MAST ARMS LUMINAIRE PED PUSH BT. SIGNAL MOUNTING S.N.S. PLACEMENT REMARKS C TYPE HT. SIG. LUM. H.P.S.V. TYPE PHASE QUAD VEHICLE PED. MESSAGE A B `-~ELm/ o� �� POLE LOCATION DETAIL VARIES It MODEL 711 OPTICAL DETECTOR it ' ` \D ' ' if | . / / AVENUE CITRUS '~-_-R/»«LINE /E\ INDICATES EXISTING CONDUIT WITH PULL ROPE LOCATE END8D INSTALL PULL BOXES A8 3H{��N ''' 08. � ' ' �-------1 ` z�2�� ." 06 03 5 06 EDGE OF PAVEMENT It 0011 ow 11 0 E 73 ------------------------------------------------------------------------------------------------ 00 --------------------------------- ------------------------------------------------------ 04 04 INTERCONNECT | ^""" `""` |8��' TO MUIRFIELD LANE SEE SHEETS 5 & 6 | -~--RA� LINE NOTE: CITY OF F(JNTANA SHALL FURNISH THE FOLLOWING EQUIPMENT.| / ` ALL TRAFFIC SIGNAL HEADS AND L.E.D. LENS, L.E.D. MODULES | FOR PEDESTRIAN HEADS, ALL POLES AND MAST ARMS, ANCHOR | BOLTS FOR ALL POLES EXCEPT 1-A'5, COMPLETE TRAFFIC SIGNAL CONTROLLER AND CABINET/NO ANCHOR �C)LT31, TYPE III -BF SERVICE | ` ' | CABINET(NO ANCHOR BOLTS), AND ALL IMAGE SENSORS. MOUNTING HARDWARE AND ALL OTHER EQUIPMENT NOT OSTEO SHALL BE FURNISHED BY THE CONTRACTOR. � R CUT - LIP ^^~^ , Now EXISTING CURB �L~ � � ANO/OR ' ~- NBW MIN [URB AND / / + / A.C. GUTTER -' TACK COAT ALL EDGES 10` MIN. --`-EXISTING A.C. SURFACE 6-1.5" SCH 40 HOPE CONDUITS AND 4 -SACK ORANGE PEA GRAVEL BACKFILL NOTE: THE SLURRY BACKFILL IS NOT REQUIRED AT DEPTHS GREATER THAN 0 FEET. DUCT INSTALLATION AND TRENCH REPAIR DETAIL AFA File: 692.003 CI T RUS— SUMMIT —ABC.DWG 11:13 AM 01/17 EXISTING CURB / wxnvc yo/L AT ymn CURB ^mo°""/"" -/ COMPACTION (IF SIDEWALK DOES oosy wnr sx/sx. oomPwCTso TO NATIVE SHALL BE pLos* WITH Sonnnowmwo SURFACE.) -~- 6-1.5^ soH 40 HOPE CONDUITS AND 4 -SACK ORANGE PEA GRAVEL BACKFILL DUCT INSTALLATION AND TRENCH REPAIR DETAIL (INSTALLATION IN PARKWAY) DETAIL "~ TOLL FREE "��1-8OO-227-2ODD A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT REV. REVISION DESCRIPTION 1 INDICATED EXISTING CONDUITS ON PLAN 2 RECORD DRAWING (��_ irt, MM.M0000 I SERVICE FEED POINT (EDISON VAULT V5515849) DATE ENGR. CITY/I DATE SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT 12/23/02 JJA. [. 11F-15 COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO RINGTHEM INTO CONFORMANCE WITH CONDITIONS AND STANDARDS IN EFFECT. / / � ] )U r 1112-) PHASE 1 PHASE 2 PHASE 3 PHASE 4 PHASE DIAGRAM SCALE 1"=20' TRAFFIC SIGNAL CONSTRUCTION NOTES | | | INSTALL CITY FURNISHED TYPE 90 CONTROLLER EQUIPMENT PACKAGE INCLUDING ^-� TYPE °R~ CABINET, AUT0SCOPE OETECT|ON, AND APPURTENANT EQUIPMENT. CONTROLLER CABINET AND FOUNDATION SHALL BE INSTALLED PER CITY STANDARD DRAWING 4004' CONTRACTOR SHALL FURNISH AND INSTALL ANY ADDITIONAL ELECT- RONIC EQUIPMENT REQUIRED TO PROVIDE THE SIGNAL OPERATION AS SHOWN ON THE PLAN. |�| INSTALL TYPE III -BF SERVICE EQUIPMENT ENCLOSURE PER CITY OF F(}NTANA AND �-^ SOUTHERN CALIFORNIA ED|SON COMPANY REQUIREMENTS. F—� ��| INSTALL UN|-D|RECT|ONAL' SINGLE CHANNEL OPT|COK� DETECTOR, (MODEL 711 OR �-� EQUAL), PER DETAIL THIS SHEET AND AS DIRECTED BY THE ENGINEER. �� |4 | INSTALL CITY FURNISHED IMAGE SENSOR UNIT PER CITY STANDARD DRAWING 133 AND �-� AS DIRECTED BY THE ENGINEER. [� ;5] FURNISH AND INSTALL SIGN AND HARDWARE PER CALTRANS DETAIL "U", E3 -13T. F�� �6\ EXISTING 6-1.5" SCHEDULE 40 HOPE CONDUITS PER DETAIL ''(�,, WITH 3 ORANGE�-� CONDUITS AND 3 BLUE CONOU|TS, ALL WITH PULL ROPES. FURNISH AND INSTALL ONE INTERCONNECT CABLE /12PR, #19\ IN ONE OF THE BLUE CONDUITS. | /| CONNECT INTERCONNECT PER TRAFFIC SIGNAL CONTROLLER MANUFACTURER'S �-/ REQUIREMENTS. F8] CONSTRUCT 4^ THICK PCC PAD (}N COMPACTED NATIVE FROM AROUND PROPOSED�—/ SIGNAL AND SERVICE CABINETS. �� ;�| INSTALL SIGN PER DESIGNATION. SEE STATE OF CALIFORNIA, DEPARTMENT OF �-/ TRANSPORTATION, /CALTRANS\ -UNIFORM SIGN CHART." [�] [xJ FURNISH AND INSTALL 2" PVC CONDUIT WITH 2 -INTERCONNECT CABLES /12PR. �1B\ �--� ' h� FURNISH AND INSTALL 3'/78rnm\ PVC CONDUIT WITH 3/8" POLY PULL ROPE PER �-~ SCE REQUIREMENTS. COORDINATE SERVICE WITH SCE /CANERA MILES 908-357-0505\. TRAFFIC SIGNAL GENERAL NOTES 0 1. TRAFFIC SIGNAL AND LIGHTING SHALL CONFORM TO THE STATE OF CALIFORNIA STANDARD SPECIFICATIONS SECTION 86 AND STANDARD PLANS (DATED JULY 1992\ 2. LOCATION Of ALL UNDERGROUND FACILITIES ARE APPROXIMATE. THE CONTRACTOR SHALL POTHOLE TO DETERMINE THE EXACT LOCATIONS AND VERIFY ALL CONDITIONS ON THE JOB SITE. HAND DIG FOUNDATIONS UNTIL CLEAR OF OBSTRUCTIONS. PHONE UNDERGROUND SERVICE ALERT AT TWO /2\ WORKING DAYS BEFORE DIGGING. 3. ALL PULLB{]XES SHALL BE No. 8 AND CONDUIT SHALL BE 2~ RIGID METAL UNLESS UNLESS OTHERWISE SHOWN. ALL INTERCONNECT PULLBOXE3 SHALL BE 48.5" X 50.5" X 30" DEEP, PRE -CAST CONCRETE, HAVE LOCKING LIDS, AND BE LABELED "COMMUNICATIONS". 4. CONTRACTOR SHALL COORDINATE ELECTRIC SERVICE DETAILS AND SCHEDULING WITH THE SOUTHERN CALIFORNIA EDl8ON COMPANY WELL IN ADVANCE OF NEED. 5. CONTRACTOR SHALL OBTAIN APPROVAL FROM THE ENGINEER FOR EXACT EQUIPMENT LOCATIONS PRIOR TO FINAL PLACEMENT' 6. ALL REQUIRED CONSTRUCTION PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA ENGINEERING DIVISION PRIOR TO COMMENCEMENT OF WORK. 7. CONTROLLER CABINET SHALL NOT BE SUBJECTED TO WATER FROM SPRINKLERS. MODIFY SPRINKLER SYSTEMS IF NECESSARY. 8. THE ALIGNMENT OF THE INTERCONNECT DUCTS SHALL BE AS STRAIGHT AS POSSIBLE, HOWEVER, WHEN CHANGES IN ALIGNMENT ARE NE[ES5ARY, SWEEPS SHALL HAVE RADII OF AT LEAST 10'. 9. ALL VEHICLE INDICATIONS SHALL BE 13' AND HAVE L.E.D. SIGNAL MO0ULES, ALL PEDESTRIAN HEADS SHALL HAVE L.E.D. PEDESTRIAN MODULES. ALL EMPTY VEHICLE, PEDESTRIAN HEADS, AND L.E.D. MODULES WILL BE FURNISHED BY THE CITY^ No. 41 STI 20258 E-2 TRAFFIC f'x/G//vff/rI/KG X/vD r/rANSpD/prAr1Ow /'ZAN4'I/rO Exp. 9 30 05 2020 NOR;FH T�UE�TIN AVENUE SANTA ANA, CALIFORNIA 92705-7827L�N C/V��, E����7 -0496 -7952I ____�5FE/0qbST, RCE 20258 EXPIRE 9-30-05 CITY OF FONTANA, CALIFORNIA TRAFFIC SIGNAL PLAN DRAWN BY: \ SCALE: JJACITRUS AVENUE AND 1 11=201 DESIGNED BY: / /V�ENUE DATE: J.J.A. Um" 12/24/02 CHECKED BY- ROVED BY- DRAWING NO.: R..c;. CITY ENGINEUR R.C.E. 51152 DATE 3188