Loading...
HomeMy WebLinkAbout3182-3g~ i 18' 18' 1 5 5 z 5 J TRACT BOUNDARY ZQ ' I R 15 3 14 I 3 �o , RW £, I I �, TYP i I I I oo� I �, MH No. 8 5 / , rn i 18 17 +' 16 O s• 13 I I 4 3 2 1 _ { I I 10+00.00 JULIAN LANE= ( [ N 19 i ' I I l` R/w `�" 5' PUE ,, - MH No. 2 I I i o I l I l i i 2 __-- - 5 PUE Z ` - - 12+65.55 JULIAN LANE 2 I I I Lo ; 10 9 I I 10+00.00 FAITH STREET 6 - _ + Co i ---- --------- -- - ----- - - - --- = 10+0.00 SHARON COURT[ I o �r — I _ _F _ I [ __ _ __ i _ + + [ `" -- I lR/W 5' PUE 57 ---------- --------- ------ -- C14 ,` I ----------------------------- - 0+18.00 8 ER �. — 3 T Ia i r j: ^I \\ i N00'06'51 "E Lo `" °2 265.55' "AS -BUILT" STA. \ 1 - t2 t oS 12 X CN 11+48 l t+ AS --- -- ---- -- I — - — — — �I 10+813 PROPOSED 8" _ X,I 4 R/W i� WATER LINE BY OTHERS X 27 28 to 4'Lo 10 13 12+55 IZt PROPOSED 36" STORM N PROPOSED 30" STORM DRAIN 12+51 PER DWG NO. 3183 PER DWG NO. 3183 I [ I f f 12+31 I L+ 3o 18'� j 18' 16 11+55 25' 25' X 17 50' It+ to JULIAN LANE SHARON COURT 1 O + (o X SEE SHT 2 0 O REV. m o E DIAL TWO -WORKING BEFDAYS BEFORE You DjG YOU DIG TOLL FREE 1-800-227-2600 A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT Z a I_ 8" WATER I I ' '-- I MH No. 3 30 10+00.00 DAVID LANE= 11+52.00 SHARON COURT I I I I I I 31 I I I SEWER LATERALS TRACT 16168 0 LOT NO. DESIGN STA. "AS -BUILT" STA. BACKWATER YES NO 1 12+08 t2 t oS X 2 11+48 l t+ AS X 3 10+91 10+813 X 4 10+71 to4.(Oct X 5 10+23 to 4'Lo X 13 12+55 IZt X 14 12+51 M+5l X 15 1 12+31 I L+ 3o X 16 11+55 11 t 53 X 17 11+11 It+ to X 18 10+48 1 O + (o X DATE I ENGR.I CITY I DATE SHARON COURT SEE SHT 2 DAVID LANE FAITH SET FAITH GREET JULIAN LANE CAROLINE NOTE: DRIVEWAY LOCATIONS SHOWN HEREON ARE APPROXIMATE. FINAL DRIVEWAY LOCATIONS AND DIMENSIONS SHOULD BE TAKEN FROM THE APPROVED PRECISE GRADING PLAN FOR THIS TRACT. BENCHMARK B.M. 1361, SPIKE IN NORTH FACE OF P.P. 11536697E AT SOUTH WEST CORNER OF BASELINE AVENUE AND SULTANA AVENUE. ELEVATION: 1365.01 CONSTRUCTION NOTES - RECORD DOCUMENT Q__ CONSTRUCT 48" PRECAST CONCRETE MANHOLE PER CITY STD. DWG. NO. 112 Z These Record Documents have been prepared based CONSTRUCT 4" VCP SEWER LATERAL & CLEANOUT PER CITY STD DWG NO 125 on information provided by others. The Design (SEE GENERAL NOTE N0. 30) QROFESS�°N professional has not verified the accuracy and/or CONSTRUCT 8" VCP EXTRA STRENGTH SEWER MAIN completeness of this information and shall not be r m responsible for any errors or omissions which may INSTALL BACKWATER CHECK VALVE W No. 43976 m ted herein as a result. �uJ Exp. 6-30-09 ;D\ og sT9 CIVIL �P FCA__� DATE Prepared By: CITY OF FONTANA, CALIFORNIA ALLARD ENGINEERING QR°FESS'° �oP�a S. Hq'���y SEWER IMPROVEMENT PLANS Civil Engineering - Land Surveying - Land Planning O _P 8253 Sierra Avenue m JK BY: TRACT W. 161 SCALE: " , No. 43976 1 =40 Fontana, California 92335 w m 01 Exp. 6/30/05 DESIGNED BY: MUM LAW DATE: (909) 356-1815 Fax (909) 35s -x795 * * JF/DH - DAMj,Aj�E SEPTEMBER, 2002 • -- 9-11- � Z' s9 C AP PR V I � ��P CHECKED PR D B DRAWING NO.: T David S. Hammer, A.C.E. 48976 Date F °F CA L � F O DH . , � �2— 3 (expires 6/30/2005) CITY ENGINEER R. C. E. 51152 3182 4 Filename: M:\DWG\15902\SEWER\FINAL–PHASE\St-3.DWG SHOULD CONSTRUCTION OF REQUMED nrPROVEMENTs NOT CoxM - wn mgr TWO YEARS OF THE DATE OF APPROVAL SHOWN HpN AW CARREOrFOMWIN A DILIGENT IIUNNER, THE CITY ENG11MM MAY REQUIRE REVISIM TO THE PLANS TO - BRM M -IN110CONIV11131AMEMW CONDITIONS AND STANDARDS IN EFFECT PREPARED FOR: YOUNG HOMES 10370 TRADEMARK STREET RANCHO CUCAMONGA, CA. 91730 (909) _ 477-6715 DAVID LANE FAITH SET FAITH GREET JULIAN LANE CAROLINE NOTE: DRIVEWAY LOCATIONS SHOWN HEREON ARE APPROXIMATE. FINAL DRIVEWAY LOCATIONS AND DIMENSIONS SHOULD BE TAKEN FROM THE APPROVED PRECISE GRADING PLAN FOR THIS TRACT. BENCHMARK B.M. 1361, SPIKE IN NORTH FACE OF P.P. 11536697E AT SOUTH WEST CORNER OF BASELINE AVENUE AND SULTANA AVENUE. ELEVATION: 1365.01 CONSTRUCTION NOTES - RECORD DOCUMENT Q__ CONSTRUCT 48" PRECAST CONCRETE MANHOLE PER CITY STD. DWG. NO. 112 Z These Record Documents have been prepared based CONSTRUCT 4" VCP SEWER LATERAL & CLEANOUT PER CITY STD DWG NO 125 on information provided by others. The Design (SEE GENERAL NOTE N0. 30) QROFESS�°N professional has not verified the accuracy and/or CONSTRUCT 8" VCP EXTRA STRENGTH SEWER MAIN completeness of this information and shall not be r m responsible for any errors or omissions which may INSTALL BACKWATER CHECK VALVE W No. 43976 m ted herein as a result. �uJ Exp. 6-30-09 ;D\ og sT9 CIVIL �P FCA__� DATE Prepared By: CITY OF FONTANA, CALIFORNIA ALLARD ENGINEERING QR°FESS'° �oP�a S. Hq'���y SEWER IMPROVEMENT PLANS Civil Engineering - Land Surveying - Land Planning O _P 8253 Sierra Avenue m JK BY: TRACT W. 161 SCALE: " , No. 43976 1 =40 Fontana, California 92335 w m 01 Exp. 6/30/05 DESIGNED BY: MUM LAW DATE: (909) 356-1815 Fax (909) 35s -x795 * * JF/DH - DAMj,Aj�E SEPTEMBER, 2002 • -- 9-11- � Z' s9 C AP PR V I � ��P CHECKED PR D B DRAWING NO.: T David S. Hammer, A.C.E. 48976 Date F °F CA L � F O DH . , � �2— 3 (expires 6/30/2005) CITY ENGINEER R. C. E. 51152 3182 4 Filename: M:\DWG\15902\SEWER\FINAL–PHASE\St-3.DWG