Loading...
HomeMy WebLinkAbout3171-474NEW MAIN 80/277V 30R41WE "MSA" 2 SINGLE LINE DIAGRAM NOTES: INTERIOR OF PLATE ENGRAVED "SYSTEM GROUND". BRACED FOR 65,OOAIC - DRY TYPE TRANSFORMER SWITCHBOARD. FULL WIDTH X 1/2" DEPTH X 2" HIGH , _. — . . — -- • NEMA 3R WITH RODENT � BARE COPPER BUS PLATE ATTACHED • . — • — ___1 � EXISTING SCE UNDERGROUND TO BE ABANDON RESISTANT ENCLOSURE. TO WALL W/ 1 /2" SPACERS. REMOVE �— �– 1200A BUS 1 2 3 4 5 6 7 8 9 10,11,12 I 2 PAINT AT POINT OF ATTACHMENT TO DISCONNECT EXISTING SYSTEM NEUTRAL BOND CONDUCTOR SWITCHBOARD. 16M I REMOVE EXISTING METER AND CT's. PROVIDE COPPER JUMPERS TAG & IDENTIFY AND COVER PLATE. EACH GROUND. COMPRESSION LUGS BOLTED TO PLATE. I - 100 A 100 A 100 A 100 A 200 A 100 A 200 A 50 A 400 A ?? A 0 q EXISTING COILS TO BE CONNECTED TO NEW MUSCO POWER DRILL AND TAP FOR REQUIRED NO. & 1200 AS 3P 3P 3P 3P 3P 3P 3P 3P 3P 3P � 3P � O LINK PANEL SIZE OF LUGS. J I 18 1 O5 1"C. WITH REQUIRED LIGHTING CONTROL CONDUCTORS TO POWER 3 ON ALL SIDES 1200 AF GFI 1 #3j0 BARE COPPER TO THE MAIN 17 1@5 17 2 023 15 9 I LINK PANEL. 4 SWITCHBOARD. a 2"C. WITH REQUIRED LIGHTING CONTROL CONDUCTORS TO POWER FLOOR LEVEL � �+... �C-----►- QC ---•- 21 LINK PANEL. 3 0 CU. TO COLD METALIC WATER SY4 1 STEM 5 # / 5 17 1$ � 1 � 18 ?� EXISTING TIME SWITCH. DISCONNECT EXISTING BASEBALL FIELD I I I I PIPING, 3/4" C. L� 1 r 1 #3/0 CU. TO METALIC GAS I I I 3 " LIGHTING CONTACTOR CONDUCTORS FROM SWITCH. —_ - PIPING - 3/4" C. _ $� 4 C. 4 #600MCM & 1 #3 E/G L — — — -- 1 #6 CU. TO MAIN TELE. FINISHED GRADE I I ( I BACKBOARD - 3f4 RCS. = PANEL CB -19 " PANEL PANEL PANEL PANEL a 1 "C. 3 #8 & 1 #10 E/G I I I I I ,.FAB" "FCD" "SF" „HR„ >,HP" PANEL E — — — — J 1-- — — -- — — — -> 1 #3/0 CU. TO BUILDING REBAR. ��� CP" 10 DRY TYPE TRANSFORMER, RE.KVA AS NOTED, 480V. 3 PHASE TO TWO 20 FOOT LENGTHS OF #3/0 - 120/208V. 3 PHASE 4 WIRE. PROVIDE ELECTROSTATICALLY CONCRETE PAD 200OPSI ® 28 BARE COPPER EMBEDDED IN CONCRETE I I " I SHIELDED AND ISOLATED TRANSFORMER DAYS REINFORCED W/6 X 6", FOUNDATION W/MIN. 2 ALL AROUND— — L. — _. — - — — — -�j 15 17 1 1 � PROVIDE 3/4"C. GROUNDING ELECTRODE CONDUCTOR SIZE AS #10 X #10 WELDED WIRE MES PER ARTICLE 250.81(C) OF 1996 N.E.C. ®— — — — 1 ` (LIFER GROUND). C C CB -17 NOTED TO NEAREST AVAILABLE COLD WATER PIPE AND TO PROVIDE ONE ANCHOR BOLTS I �O ��`� MUSCO SUPPLEMENTAL PER C.E.C. 250-26 AND C.E.C. 250-81 AT EACH CORNER ON INTERIOR SCALE `� J POWER WITH (1) 5/$ DIAMETER SYSTEM "► Y ST E M GROUND DETAIL N.T.S. � 1 17 LINK 12 2"C., 4 #3/0 & 1 #6 E/G. RED HEAD WEDGE ANCHORS V 1 V 4" EMBEDMENT MINIMUMI a • e s • � • � o • � � 13 CABLE LENGTH SHALL NOT EXCEED 10 FEET IN LENGTH. � \ I (IN ELECTRICAL 1 4 1 "C. 3 #6 & 1 #8 E/G PLAN NOTES: (DETAILS 4 & 5) ROOM) SCALE 1 PROVIDE GFI TYPE RECEPTACLE ', \ 75KVA 15 PROVIDE 100A -600V -3P CONTACTOR/277V COIL DETAIL N.T.S. + " ABOVE COUNTER OR SPLASH /� \ (WALL MOUNT) XFMR 6 10 Q'� 1 6 PROVIDE 200A -600V -3P CONTACTOR/277V COIL TRANSFORMER MOUNT 6 BO 3 VERIFY EXACT MOUNTING HEIGHT W/ OWNER PRIOR TO ROUGH -IN #611 �� 17 1 1 f2"C., 4 #3 & 1 #8 E/G 1213 g 2..0 4 #3/0 & 1 #6 E/G A(2 3'i 7 i 19 2"C,O. STUB UP AND CAP OFF +12" A.F.G. 2'_s" � \ \ LOAD SUMMARY WP 3 20 PROVIDE SPACE FOR (3) 400A/3P CIRCUIT BREAKERS, FULLY BUSSED. PANEL FAB –BUS 1 52.0 KVA 5 PANEL FAB - BUS 2 52.0 KVA PANEL I (E) 400A BUS \ \ PANEL FAC -BUS 1 52.0 KVA "LP" M1 21 STUB OUT (3) 4-C.O. INTO TURF AREA, CAP AND MARK. SIGN f PANEL FAC - BUS 2 52.0 KVA .� �- — — — — — / \ PANEL SF 108.0 KVA I + I (E) I 5 5 � PROVIDE SPACE FOR 100A-60OV-3P CONTACTOR/277V COIL. / S PANEL HR 20.0 KVA Z I 400 A PROVIDE SPACE FOR 20OA-60OV-3P CONTACTOR/277V COIL o \ PANEL HP 50.0 KVA 51 QK�A I 3P EXISTING LB SERVICE MS 266.7 KVA ( I I 51.0 KVA4 1 "C.O. TO MUSCO CONTROL LINK. TOTAL LOAD 703.7 KVA19 19 5 I C C 2"C., 4 #1/0 & 1 #6 E/G or 844.4 AMPS I I I , �� 38 AT 480/277V. 30 4W ,– ,> `%' < 177 FUTURE FUTURE I o 7 15'-0" .I 6 0 S i PANEL PANEL I ❑�2 So " PT" " I \ "TP PANEL L . I t "CB" — 1 EXSITING SERVICE "MS" 3 480/277V30 4W 4 2B 1 0 � 3 SCALE 1 CiRCUIT IDENTIFICATION 3 SINGLE LINE DIAGRAM N.T.S. WEST SIGN – CIRCUIT "HP -1'° / V I 3 NORTH SIGN – CIRCUIT "HP -1" 188" NORTH/EAST SIGN – CIRCUIT "HP -8" f/ SCALE 1B 31 3 3 3 .� 42" V 42" 38" V 38" 28" SIGN LIGHTING DETAIL N.T.S. ? 30 1 , T . NO ES.. 3 ` 3 3 1. PROVIDE CONCRETE PAD FOR SWITCHBOARD AS DETAILED WITH MINIMUM 3" AROUND GEAR (SIZE AS REQUIRED) 10 CB -7,9 1 , z J / 2. THE DIMENSIONS USED ARE BASED UPON RSE-SIERRA .MANUFACTURES PRODUCTS. � 120V, 40 IS N • 3 INSURE THAT THE PRODUCT WRODFTTWITHIN RTHEHSPACE PROVIDEDTHE . SHALL 3 TOP VIEW 1 PROVIDE MUSCO TO EXIST. POWER LINK COILS 7 & 8 PANEL AT EXISTING FIELD IBE SEE SINGLE LINE DIAGRAM 1 PANEL "LCP" 30 1 TSA' 8 TO "TB" CB -15,17 A J� TS1 SWBD T 1 3 SEE DETAIL.., #5 THIS !-{a C1 65 1 IN THIS FAREAPOWER !OF MUSCO CONTROL 17 TYP, C1 LINK 13 !(I 1AE 1 J PANEL CB H ;I 3 33 TELEPHONE BACKBOARD 65 1 "TB" 3 TYP. 1 TS2 SWBD C2 B-11,13 j CB -31,33 lOFF H 13\210 T 1 1 H ...�..— TS3 G3 SWBD North ----!'" TOFF PANEL LP O LOCATI❑N, MAIN' ELECTRICAL ROOM 225A/3P 42 OOOAIC BUS RATING 225 AMP VOLTAMPS OA OB 0C BUS RATING 225 AMP 120/208V 30 4W MOUNTINGo SURFACE LOCATION VOLTB I �C �A OB CIR KR A B C KR CIR BTAMPSOC OA I OB LOCATION PANEL CB 11860 N, SNACK RECEPTS 1 150 1 100 2 3500 IFUTURE PANEL 'PT' --- 9950 3 2 4 3500 -® _- 12682 5 3 ` 6 20 14 360 N, SNACK RECEPTS FUTURE PANEL 'TP' 2900 7 50 - 8 110 ' _-- 2900 9 2 10 20 20 1 900 S. SNACK RECEPTS 11 - - 12 - 23 20 13 - - 14 20 26 360 & SNACK RECEPTS BACKSTOP RECEPTACLES 360 15 20 - 16 - 29 ENERAL C T L 900 31 20'1 BACKSTOP RECEPTACLES 360 17 20 - 18 20 32 900 S, SNACK RECEPTS FUTURE HOCKEY ARENA RECEPT, 500 19 20 - 20 N. WATER HEATER 3000 35 40 FUT, HOCKEY ELECTRONIC EQUIF 1000 21 20 - 22 ' FUL HOCKEY ELECTR❑NIC E"�UI 1000 23 20 - 24 L 20 421 1 1 500 15260 14210 14046 OA = 18760 SUB TOTAL OB =17710 16395187621 3500 3500 0 0C z 14046 , et, w f w �rt.K U wfi5 rho -N& wrowr.5 fila*% 200 0LU PANEL PANEL HR HP QC5 PANEL C@C6 SF \ 3" � C3� - _ PANEL PANEL FAB FGD C(�C3 @C1 C@C4 @C2 ELECTRICAL ROOM 150A/3P 42 OOOAIC CIR KR A B C KR 0 BUS RATING 225 AMP VOLTAMPS OA OB 0C TOTAL CONNECT D�V�A~ � 50516 VA PUBLIC TOILET LTG. A STUB OUT C4> 2'C,M & (6) VC.O. +50'-0' TO SOUTH TO TURF AREA, DIST. LCL 2272 VA 2 25% = 568 VA CAP AND MARK 0- KR CIR MAIN 2 900 DIST. DIST. SECT, N, SNACK RECEPTS ELECT RM,/STORAGE ROOMS LTG 835 3 120. 20 4 900 N. SNACK RECEPTS SNACK BAR LTG, 1062 5 120 20 6 900 N. SNACK RECEPTS HAND DRYER CONC, 1200 1 7 20 20 $ 360 N. SNACK RECEPTS �{y �–--p C4`/`1 L—CONCRETE PAD 2000PSI AT 2$ k CORNER OF EACH SECTION ON SCALE DAYS REINFORCED WITH 6"X 6", INTERIORS WITH (1) 5/8"0 PHILLIPS R.N. *OFF , r, 10 X 10 WELDED WIRE MESH. 4" EMBEDMENT MINIMUM H - � CONCESSION BUILDING FLOOR PLAN 4 # # A A TS5 SWBD 3 !- C C5 / 4 \ *OFF �� 4 /r 3 \ \ SCALE He 2 \ MAIN SWITCHGEAR ELEVATION N.T.S. 2 _LTS6 SWBD / CB -214 6 \ C I \, X TOFF t --0611I' 1 2 16 � 10 24 0 C6 � T / , d1 2 \ WH / , ; "�� 3 \ 18 _ I 3"C., Wf ALL REQUIRED CONTROLr �, CONDUCTORS FROM SWITCHBOARD 8 14 < j' g 22 3 PILOT LIGHT CONTACTORS TOPANEL LCP \ TSA -1 TSA- 5 i 1 2 CB -18,20, 2 (BASEBALL FIELD A) (SENIOR BASEBALL FIELD) 3 TSA- 2 TSA- 6 14 (BASEBALL FIELD (HOCKEY ARENA) TSA- 3 TSA- 7 8 TSA- (BAS4EBALL FIELD C) TSA (EXISTING BASEBALL FIELD -NORTH) 12,14,16 26 32 / (BASEBALL FIELD D) (EXISTING BASEBALL FIELD -SOUTH) 8 8,1 / ,10 � / A G t1� �► LIGHTING CONTROL. PANEL 'LCP" IN ELECTRICAL ROOM 28,26.2 41 SCALE 1 #10' 2 & 30 f WIRING DIAGRAM N.T.S. $ 3 PROVIDE NEMA 3R, HINGED, LOCKABLE 3/4"C., 2 #8 & O 1 #1fl E/G DOOR JUNCTION BOX WITH ONE 125V DOUBLE DUPLEX ON INTERIOR CB -I "C., 437 9,41 1 1 "C., 4 #8 #10 E 30 PANEL C LOCATION H 6 t Ted .� w fiWRQ ELECTRICAL ROOM 150A/3P 42 OOOAIC CIR KR A B C KR �- �---- PANEL LP s PANEL HP Q ! or u� �u 4 r/ `-S R BUS RATING 225 AMP VOLTAMPS OA OB 0C TOTAL CONNECT D�V�A~ � 50516 VA PUBLIC TOILET LTG. A STUB OUT C4> 2'C,M & (6) VC.O. +50'-0' TO SOUTH TO TURF AREA, ~ � �L- _._ - . - - _... - ._... - _ _... - - - ._._. � � � - - o _ - - - ®_ PRC)VIDF ANCHOR BOLTS AT EACH LCL 2272 VA 2 25% = 568 VA CAP AND MARK 1084 T❑TAL PANEL L❑AD = 51084 VA KR CIR FEEDER AMPS = AMPS 2 �{y �–--p C4`/`1 L—CONCRETE PAD 2000PSI AT 2$ k CORNER OF EACH SECTION ON SCALE DAYS REINFORCED WITH 6"X 6", INTERIORS WITH (1) 5/8"0 PHILLIPS R.N. *OFF , r, 10 X 10 WELDED WIRE MESH. 4" EMBEDMENT MINIMUM H - � CONCESSION BUILDING FLOOR PLAN 4 # # A A TS5 SWBD 3 !- C C5 / 4 \ *OFF �� 4 /r 3 \ \ SCALE He 2 \ MAIN SWITCHGEAR ELEVATION N.T.S. 2 _LTS6 SWBD / CB -214 6 \ C I \, X TOFF t --0611I' 1 2 16 � 10 24 0 C6 � T / , d1 2 \ WH / , ; "�� 3 \ 18 _ I 3"C., Wf ALL REQUIRED CONTROLr �, CONDUCTORS FROM SWITCHBOARD 8 14 < j' g 22 3 PILOT LIGHT CONTACTORS TOPANEL LCP \ TSA -1 TSA- 5 i 1 2 CB -18,20, 2 (BASEBALL FIELD A) (SENIOR BASEBALL FIELD) 3 TSA- 2 TSA- 6 14 (BASEBALL FIELD (HOCKEY ARENA) TSA- 3 TSA- 7 8 TSA- (BAS4EBALL FIELD C) TSA (EXISTING BASEBALL FIELD -NORTH) 12,14,16 26 32 / (BASEBALL FIELD D) (EXISTING BASEBALL FIELD -SOUTH) 8 8,1 / ,10 � / A G t1� �► LIGHTING CONTROL. PANEL 'LCP" IN ELECTRICAL ROOM 28,26.2 41 SCALE 1 #10' 2 & 30 f WIRING DIAGRAM N.T.S. $ 3 PROVIDE NEMA 3R, HINGED, LOCKABLE 3/4"C., 2 #8 & O 1 #1fl E/G DOOR JUNCTION BOX WITH ONE 125V DOUBLE DUPLEX ON INTERIOR CB -I "C., 437 9,41 1 1 "C., 4 #8 #10 E 30 PANEL C LOCATION LOCATIONi L MAINS VOLTAMPS OA OB OC ELECTRICAL ROOM 150A/3P 42 OOOAIC CIR KR A B C KR CIR BUS RATING 225 AMP VOLTAMPS OA OB 0C 120/208V 30 4W MOUNTING, SURFACE LOCATION PUBLIC TOILET LTG. 780 VOLTAMPS �A s�B �6C 1 120 KR - KR CIR 20 2 900 400 N, SNACK RECEPTS ELECT RM,/STORAGE ROOMS LTG 835 3 120. 20 4 900 N. SNACK RECEPTS SNACK BAR LTG, 1062 5 120 20 6 900 N. SNACK RECEPTS HAND DRYER CONC, 1200 1 7 20 20 $ 360 N. SNACK RECEPTS HAND DRYER COLIC, 1200 9 20 20 10 900 N, SNACK RECEPTS HAND DRYER CONC, 1200 11 20 20 12 900 N. SNACK RECEPTS HAND DRYER CONC, 1200 13 20 20 14 360 N, SNACK RECEPTS MUSCO POWER LINK 1000 15 20 20 16 360 N. SNACK RECEPTS PANEL 'LCP' 500 117 120 20 18 900 S. SNACK RECEPTS TIME SWITCH 500 19 120 20 20 1 900 S. SNACK RECEPTS - 21 20 20 221 900 S. SNACK RECEPTS - 23 20 20 24 360 S. SNACK RECEPTS SPARF_ 25 20 20 26 360 & SNACK RECEPTS - 27 2 2Q 28 900 S, SNACK RECEPTS - 29 ENERAL C T L 900 31 20'1 20 30 360 IS, SNACK RECEPTS 20 32 900 S, SNACK RECEPTS TELEPHONE BACKBOARD 360 33 20 34 - SPACE N. WATER HEATER 3000 35 40 36 - SPACE ___ 3000 37 2 20 38 500 S. WATER HEATER 13000 1 139 40 20 40 500 1 IRRIGATION CONTROLLER 3000 1 41 1 2 20 421 1 1 500 7580 16395187621 _ SUB TOTA 3125 14280 13960 13920 - 14 - OA = 11860 1980 OB = 9950 - OC = 12682 NORTH CENTER WALK LIGHTING PANEL HP L FINISHED GRADE 12" NOTE: BOX SHALL BE LOCATED Af+AlkICT DAf'V CTAD c*NrF LOCATION, MAINS IN MSA M.L.O. 65,OOOAIC CB -30,32t CB -^`�, ''' ' 30 /'s. BUS RATING 225 AMP 480/277V 30 4W MOUNTINGS FLUSH LOCATION VOLTAMPS �A s�B �6C CIR KR A B C KR CIR VOLTAMPS ;pA OB I 0C LOCATION WEST & N,W, SIGN LIGHTING 400 1 20 20 2 2860 EAST PARKING LOT LTG. SPARE 500 3 20 2 4 2860 - WEST PARKING LOT LIGHTING 3510 5 20 20 6 1505 EAST WALK LIGHTING - 3510 7 2 20 8 2405 EAST WALK LTG & NE SIGN SOUTH WALK LIGHTING 2520 9 20 - 10 _ CENTER WALK LIGHTING 1865 11 20 - 12 _ PLAY/RINK WALK LIGHTING 3125 13 20 - 14 - N,E, WALK LIGHTING 1980 15 20 - 16 NORTH CENTER WALK LIGHTING 1800 17 20 - 18 x - - 19 - - 20 - 22 _ 23 - - 24 _ _ - 25 27 29 - - /--.N20 - 26 _ - 28 - 30 780 S.W. PARKING LOT LIGHTING - 31 2 32 780 - faq)b - 33 20 34 - SPARE - 35 3 20 36 2405 SOUTH WALK LIGHTING _ 7 39 _ _ 20 38 2045 S.E. WALKWAY LIGHTING 20 40 1560 S.E, PARKING LOT LIGHTING TIMESWITCH 100 41 20 2 42 1560 --- 7035 5000 7275 SUB T❑TAL 8090 14420 16250 OA = 15125 OB = 9420 OC = 13525 SCALE A L FINISHED GRADE 12" NOTE: BOX SHALL BE LOCATED Af+AlkICT DAf'V CTAD c*NrF /�\ PANEL fj //f CB -30,32t CB -^`�, ''' ' 30 /'s. htio� TOTAL CONNECTED VA LCL, 2272 VA 2 25% TOTAL PANEL LOAD FEEDER AMPS = 34897 VA = 568 VA = 35465 VA = 98,6 AMPS A PROVIDE 7 -DAY, 24 HOUR, ON/OFF ELECTRONIC TIME SWITCH, 120V, TOTAL, CONNECTED VA. LCL, 38070 VA 25'/. TOTAL PANEL LOAD FEEDER AMPS = 38070 VA =_ 9518 VA = 47588 VA = 57.3 AMPS MOUNT IN PANEL ENCLOSURE B CONNECT TO TIME SWITCH, C STUB OUT (6) 11C.O, +50'-0' TO SOUTH TO TURF AREA CAP AND MARK SCALE A PROVIDE 4-OCHANNEL, 24 HOUR ELECTRONIC TIMESWITCH 277V, B PROVIDE (2) 6 -POLE CONTACTORS 480/277V COIL, CONNECT TO CHANNEL 'a' OF TIMESWITCH, C PROVIDE t2> 4 -POLE CONTACTORS 480/277V COIL, CONNECT TO CHANNEL 'b' OF TIMESWITCH, D CONNECT TO CHANNEL 'c' OF TIMESWITCH, SCALE PARTIAL POWER BUILDING FLOOR PLAN RECEPTACLE DETAIL N.T.S. DATE ENGR. CITY DATE CITY OF FON TAN A, CALIFORNIA SCALE: AS NOTED REV ��� DESCR�110N Prepared Under The Supervision Of A [� 5 b'� CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT ELECTRICAL PLAN DATE. 5/15/02 � h .SHOULD CONS Engineering Inc. .� _ -• ,� - ,� � .� � q h! COMMENCE WITHIN T WO YEARS OF THE DATE OF APPROVAL DRAWN B FM3 , ADILIGENT MANNER,Eleetrieai Engineering & consulting �. SHOWN HEREON ANDCARRIED FORTH IN JACK BULIKPARS p E-3 g DESIGNED BY. 7939 Patin Ave ;' - THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO DIAL TWO WORKING ; _._ m yrs-, PHASE Highland. Ca. 6 0 BEFORE DAYS BEFORE _4 BRING THEM INTO CONFORMANCE WITH CONDITIONS AND WC 92346 Date CHECKED BY: APPROVED BY: DRAWING NO.: 7 909 864-0223 � ti YOU DIG YOU DIG }: STANDARDS IN EFFECT. Fax 909 864-0280 c ung JTT/JCC �,, / ��'• GZ caeng @earthlink.net ., a TOLL FREE 1 -800 -2z7 -26Q0 v � P ,, CITY ENGINEER R.C.E. 5115.2 3171 DATE: 73 jeaeng@earthlink.net PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT mm