HomeMy WebLinkAbout3170-1CONDUCTOR SCHEDULE OR CABLE SIZE POLE • � • . 04 NOT 0000000 HP8V LUMINAIRE NON -ILLUMINATED STREET NAME SIG USED DESCRIPTION POLE HEIGHT SIGNAL MAST ARM LUMINAIRE MAST ARM �I "B" MAST ARM VEHICLE POLE VEHICLE POLE PEDESTRIAN 0 ARROW NOT NOT NOT 10' USED USED 1 USED 11 1 11 05 1 08 R07 08 - - - - B 22 35' - 15' 13' 4' - - - 4 -�►— N 250W - C 1-A 10' - - 13' 4' - TV -1-T SP -1 -CS 4 —► N - - D 26A-4-80 TOTAL CABLES 3C/12C 40' 15' 13' 4' 2 -MAS SV -1-T SP -1 -CS 2 ���000eooeo W 250W Heritage Triangle E 19A-3-80 35' 25' 15' VIDEO COAXIAL CABLEVIDEO 00000000 - SV -2-T SP -1 -CS 2 --i•► W 250W POWER CABLE 29A-5-80 35' 50' 15'PLAN SEE ----1 1 5' 3 -MAS SV -2-T - - - - 250W Heritage Triangle CONDUIT SIZE fin.) 00000000 EXIST. 2"C W/0 SIC TO CONTROLLER O HERITAGE CIRCLE & BASELINE AVE. PHASE DIAGRAM 01 02 03 04 NOT PED PUSH BUTTONS HP8V LUMINAIRE NON -ILLUMINATED STREET NAME SIG USED DESCRIPTION POLE HEIGHT SIGNAL MAST ARM LUMINAIRE MAST ARM �I "B" MAST ARM VEHICLE POLE VEHICLE POLE PEDESTRIAN 0 ARROW NOT NOT NOT 10' USED USED 1 USED 11 1 11 05 1 08 R07 08 11 Curb/Berra flow lin or edge o Voulde BCR W U W SIGNAL STANDARD PLACEMENT DIMENSIONS AND EQUIPMENT LOCATIONS POLE AND EQUIPMENT SCHEDULE POLE SIGNAL STANDARD PLACEMENT DIMENSIONS SIGNAL MOUNTING PED PUSH BUTTONS HP8V LUMINAIRE NON -ILLUMINATED STREET NAME SIG NO. DESCRIPTION POLE HEIGHT SIGNAL MAST ARM LUMINAIRE MAST ARM "A" "B" MAST ARM VEHICLE POLE VEHICLE POLE PEDESTRIAN 0 ARROW QUAD A 1-A 10' - - 13' 4' - TV- SP -1 -CS - - - - - B 22 35' - 15' 13' 4' - - - 4 -�►— N 250W - C 1-A 10' - - 13' 4' - TV -1-T SP -1 -CS 4 —► N - - D 26A-4-80 35' 40' 15' 13' 4' 2 -MAS SV -1-T SP -1 -CS 2 --NF— W 250W Heritage Triangle E 19A-3-80 35' 25' 15' SEE PLANF A4.5'. - SV -2-T SP -1 -CS 2 --i•► W 250W Baseline Ave 29A-5-80 35' 50' 15'PLAN SEE ----1 1 5' 3 -MAS SV -2-T - - - - 250W Heritage Triangle INSTALL ADDITIONAL LUMINAIRE ARM CONNECTION ROTATED 90' FROM MAST ARM AS SHOWN BELOW. CAP UNUSED MOUNTING IN A WATERPROOF MANNER. T N EXISTING R/W I I EXISTING R/W . 1 t i :s �smms ------------------------------------ ----- --- - --------- -- - ----- - I� 1 _______ _________ _________ ___ EXISTING C&G IT7 EXISTING C&G 8 �2 02 11 11 1 12.8 RCB -------- --------------------------------- -- --- DETAIL "A" I ii -- -- ----- ----- ----- ----- ----- ----- ii ii 12x8 RCB--- ----- ----- ----- - -= ---------------------------- -- 7 -- -------'�-----,3- ----II II I 1 - - --------- --------------- ----- --------------------- --------- if------------------------------------------------------------- - -- -- ----- ----- ----- II 11 -- -------------- --------------II II 1 TEL----------------------------TEL----------------------------TEL------------------------------------------------------ TEL---------- -- II ---- +-------- 1--------------------------TEL----------------------------TEL----------------------------TEL------------ - II 11-------- I ------------------------------------------------------------- 03--------- -- ---- 8"S----------------------------8"S---------------------8"S---------------------- - 8'S--------------�� JOINT TRENCH --------------------- --- ------------ -- --- 6 66 67 � f ---- � �-------- 1-----68 -------------------- 8's-----------------------<<-�z, 8"s-----69 ----------------- 8"s-------- - LIN NIT E - - I - - - I - I- - - --, I V II Ir IIIsm I Is %R Iwo ii �� 1 ---- i i 11 I 1 -------------- ---------------- ---- ----- 4 W----------------------------4"W-------------------4"W-------------- 4"W-------------4"W-------------------------------4"W-----------------------4"W----------------------------4"W-------------- --- ----------- - - --- ---------------1L------------ 11 1 II II 11 cc 1* II 04 11 II 1 - 2 ----- ----- ----- ----- --------------------------------- ------- ---------------- - ----- ----- - 2 6 3"C &PULL ROPE 1 2-C, 28 �SERVICE) G.F.C.I.) FOR SCE CONDUCTORS -------------------------------------------------�� ii 13 1 2 EXISTING C&G CONSTRUCTION NOTES ❑1 — Furnish and install TYPE 90 Controller equipmentckae including TYPE "R" Cabinet, Autoscope Detection, and appurtenant equipment eS)9'eeSpecial Provisions). Controller cabinet and foundation to be installed per City Standard Drowinq 134. Contractor shall furnish and install any additional electronic equipment required to provide the desired signal operation as shown on the plan. Connect SIC per traffic signal controller manufacturer's requirements. F2 — Furnish and install TYPE III -BF Service Equipment Enclosure per City of Fontana and Southern California Edison Company requirements (See Special Provisions). R3 — Furnish and install AUTOSCOPE camera on shaft with side mount bracket. Furnish and install necessary cables and make necessary connections in the controller cabinet per manufacturer's specifications. Controller cabinet to be modified for video per City of Fontana standards (See Special Provisions). 44 — Furnish and install AUTOSCOPE camera and bracket per city Standard Detail No. 133. Furnish and install necessary cables and make necessary connections in the controller cabinet per manufacturer's specifications. Controller cabinet to be modified for video per City of Fontana standards (See Special Provisions). 0 — Furnish and install unidirectional, single channel OPTICOM Detector (Model 711 or equal), per detail this sheet and as directed by the Engineer. (See Special Provisions). © — Furnish and install R73-2 sign per CALTRANS Standard ES -6T, Detail U. 7l — Furnish and install R34-2 sign per CALTRANS Standard ES -6T, Detail U. ® — Furnish and install R96/96A sign on traffic signal pole. Q — Furnish and install SIC in existing conduit. ®— Furnish and install 2" conduit and SIC. ITOLL FREE 140a-227-2000 A PUBLIC SERVICE BY INiDERORMI D SERVICE ALERT 0 1 I _^$ d � HERITAGE TRIANGLE DRIVEWAY EMERGENCY VEHICLE PREEMPTION DETECTOR 1 1/2- TO REDUCER - — w.-"— +.:wwiii.:vii:: iwr 1 N n S SCALE 1"=20' TOXISTCONTROL ERSIC ® CHERRY AVE. & 10 0 5 10 20 40 BASELINE AVE. J .. ♦y --,� __ �T 111 �-1- ---r-i - II II♦ ------------ --------- --------- ---------II II ------------------------- ---- I '•_-__ II II ------------ I I "_- I I I � ; ii ii I R � II II -----------'--------------------------- -------------------------•7ITI - ------------' ----rITI --- --7 ---- --------- - Hr I ---------------------------------------------------- -- TEL -ii-----H----- I� � II II II II I 1 , 74 --------------- II N j3 - - ....1,----- 11 IIf, H ____i ------------71 I I I I I r�--- ci� II II II � II II II � II ------------ II II I --------- ------------ " ------------ ------------ - ------ --------------- II II ; II II II , II ; II , ii II II i 1 II II 1 II II 1 ------------ II II I.I'' II jj II 11 ;i II II i 11 i i i ♦ .: `.�•.: a':•SSSS:...:::.�................................. ,. ............ i ............... i :r .. r. EXISTING R W - --- 2-C, 2#10 (LIGHTING) ;._,;`�:::��:j:.:•:�;:•. " - '�::�•;:�•::•::;;.::::�'• :r\SSSS. -- _---- -- _ •:..t�: r:::::� :. EX. SCE HANDHOLE _-__ --- _--- (120v/240v SERVICE) :•.:::.::. �.:. __ , I II II 1;+:;.:::::::: %"�♦ I II II I '"�' c.r • I I II I II II I II II I I II II I I II II 1 GENERAL NOTES HERITAGE VILLAGE CENTER ENTRANCE 1. All work and material shown on this plan shall conform to the State of California, Department of Transportation (CALTRANS) Standard Specifications and Standard Plans dated July 1992. NOTE: 2 Tf ALL SECTIONS 12" :0 ASTRO Mini-Broc MOUNT PELCO AB -121 Ul OR APPROVED EQUAL MODELMAST-ARM MOUNTING CLAMP FOR OPTICAL DETECTOR SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMENTS NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPROVAL SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE PLANS TO BRING THEM INTO CONFORMANCE WITH STANDARDS IN EFFECT. REV. RECORD DRAWING — CONTROLLER MOVED RECORD DRAWING — "B" REVISED he city right -o way shall be kept clear of debris, with dust and other nuisances being controlled at all times. The Contractor shall be responsible for any clean up on city right-of-way affected by his construction. The method of street cleanine shall be by dry sweeping of all Paved areas. There shall be no stockpiling of construction materials within the city right-of-way without permission from the Engineer. 3. The Contractor shall determine the exact location of all underground facilities and provide grotection prior to and durin trenching, jacking or boring. Contact UNDERGROUND ERVICE ALERT (USA) at (800) 227-200, and all utility companies involved at least 48 hours before excavating. 4. The Contractor shall obtain all necessary permits. It shall be the Contractor's responsibility to coordinate all phases of construction with the various utility companies involved. 5. Location of all equipment shall be approved by the Engineer prior to final placement. 6. All pull boxes shall be No. 6 unless otherwise noted on the plan. 7. All vehicle heads metallic and louvered. DETAIL shall be cast aluminum with 12" indications. All backplates shall be x "All A 8. Most arm signs shown on the plan shall be furnished by the Contractor. N.T.S. 9. All vehicle and pedestrian signal face sections shall be LED'S, see Special Provisions. REVISION DESCRIPTION I DATE JENGR.' CITY I DATE dFESS/ S. 3 J No. 13493 * Exp. 3-31-05 C/Vi\- `P 9TF OF CA��F SERVICE ADDRESS: 14341 BASELINE AVENUE Prepared Under The Supervision of: CITY OF FONTANA, CALIFORNIA LAWRENCE S. EISENHART CONSULTING ENGINEER TRAFFIC SIGNAL PLAN 2070 Locust Court DesignL.SBE.' BASELINE AVENUE Scale: = 20 San Bernardino, California 92404 ' Tel: (909) 864-5406 Fax: (909) 864-5047 Drawn By: an Date: L.S jjj� ITAG9 RIANGLE Sep 2004 Checked By: LAWRENCE . EIS NHART RCE 13493 D' /4TE " °D r. No.: ° 3170 1 1 File No. 01-30