Loading...
HomeMy WebLinkAbout3163-4A SEE PLANS FOR MEDIAN WIDTH WHERE CURB ELEVATIONS VARY INSTALL TO DRAM TO LOW CURS. SEE`, DETAIL A 1' CONCRETE GAF' 8 T*M SET ROCK TO R" OEM IN CONCRETE BED ROCK AND BACK OF CURB VMH REQ 1/2* EXPOSURE At' W TC•• VA RE BRUSH FINISH JOINTS BETWEEN ROCKS ROCK HEIGHT 6' MIN. PEA {RAVEL CONCRE7f ItIE'D �- 1/2 WH MM TC DETAIL A / NOT TSD SCALE FOR ILLMS' MTM PURPOSE'S ONLY •• *4 1Ia MIN. COMPAC EI) � OR BASE MATERIAL PER PLANS AND Sl 1. ROCK SIZES UNLESS OTHERWISE SPECIFIED SHALL DE: COddLE5tONES: MAX. 12" TO MIN. 6" WITH ONE 510E,FLAT. 2. % INCH MIN, EXP45UXE. OF ROCK ADM TOP OF CURB.. 3. A SAMPLE AREA. MIN, 10 50. FT. SHALL 15E APPROVED 15Y THE CITY INSPECTOR PRIOR TO PROCEEDING WITH THE REMAINING ROCK WORK. 4. FINAL RESTING POSITION OF. ALL ROCKS SHALL SE APPROVED MY THE CITY INSPECTOR. 5. ROCKS SHALL BE SMOOTH. ROUNDED, FREE OF O6JE:CTIONA81„E DI5FIGURA11ON5 AND IRON CONTENT AS A"r.OYEO MY THE CITY INSPECTOR 6. CONCRETE SHALL DE CLA55 520-D-2500 4 INCH SLUMP CONCRETE. 7. MIRE BRUSH ALL JOINTS AFTER THE INSTALLATION OF THE ROCKS 8. AFTER CONCRETE MORTAR HAS SET, HYDRO BLAST A5 DIRECTED dY THE CITY INSPECTOR* 15RU•5H ROCKS TO REMOVE CEMENT COATING. S. WHERE ROCK WKDEKS TURF AREA, PLACE: i" CONCRETE EDGE BETWEEN RACK OF ROCK AND TURF. MEDIAN RIVER ROCK 117 24" GROUTED RIVER ROCK CONCRETE CURB PEA GRAVEL CONCRETE SETTING BED - 4" THICK • • - - =III=III=1 A.0 PVMT. „' I I-III-III=1 I-III=III- FE -TI COMPACT SUBGRADE TO 90% RELATIVE COMPACTION TYPICAL PLANTER EDGE I18 19 VALVE BOX O1 FINISH GRADE/TOP OF MULCH O POP-UP SPRAY SPRINKLER: FINISH GRADE 1 \ GALVANIZED TURNBUCKLE TYP. O PVC SCH 80 NIPPLE 1/2" DIA. GREEN �� 10 GA. GALVANIZED GUY WIRE TYP. 2 (LENGTH AS REQUIRED) gg GARDEN HOSE TYP. \1/2" DIA. WHITE POLY TUBING O MARLEX STREET ELLS BALL VALVE SEE IRRIGATION � \\ FINISH GRADE O5 PVC SCH 40 TEE OR ELL z O PVC LATERAL PIPE 12" MIN. DEPTH m 1 1— 111 11 1 —1 1-1 1 1 n `0 EXTENSION - LENGTH AS REQUIRED �= ROOTBALL 2" X 4" X 18" REDWOOD DEADMAN O EACH GUY -III—III— PLACED AT A 45 DEG. ANGLE 4" BELOW FINISH GRADE NOTE: GUYING OF MULTI -BRANCHED TREES IS LEFT TO THE CONTRACTORS DISCRETION DEPENDING ON BRANCH STRUCTURE AND WIND EXPOSURE. SET TREE 1" ABOVE ADJACENT FINISHED GRADE. PLACE IN EXCAVATED HOLE TWICE THE WIDTH OF THE ROOTBALL. REFER TO TREE STAKING DETAIL FOR PLANTING PR SPECIFICATIONS. TREE GUYING 13 I 3/4" RADIUS 6" LAWN / FIN. GRADE •'..•: ' . •'••, • •� IIIIIIIIIIIIIIIIIIIIIIIIIIIII SF•AQLIB AREA / FIN. GRADE : • ' _ 4 04 BAR CONT. :. ;a NOTE, INSTALL EXPAN61ON JOINTS AT B' O.G. * BETWEEN ALL PLANTER AND TURF CONCRETE MOAN CURB 114 03?' ALL GROUND COVER TO BE PLANTED O EQUAL SPACING (TRIANGULAR) PER ON CENTER SPACINGS ON SHEET L-6 W EQUAL SPACE GROUNDCOVER IN A TRIANGULAR FASHION SPACING AS INDICATED ON LEGEND 1" THICK MULCH PLANTING SOIL do FERTIUZER 6" MIN. COMPACTED SUBGRADE GROUND COVER PLANTING 15 1 OR 5 GAL SHRUB 1* THK. MULCH SEE PLANTING PLAN SHEET L-6 TEMPORARY WATERING BASIN FINISHED GRADE 6" MIN. ---"'r PLANTING SOIL do 6" MAX. --L FERTIUZER PLACE 1 - 2 AGRIFORM �— EXISTING SUBGRADE FERTIUZER TABLETS AT PIT SHALL BE 1-1/2 THE THE BOTTOM OF THE DUE. do TWICE THE DEPTH PLANTING PR. OF THE ROOT BALL TAMPED BACKFILL MIX FIRMLY. COMPACT TO AVOID SETTUNG. NOTE: • UNTANGLE MATTED ROOTS BY LOOSENING ALL ROOTS AT SHRUB PLANTING DETAIL 16 l WALL * ONLY NEXT TO WALLS SPRAY OR BUBBLER PLASTIC SHRUB ADA :�"H GRADE/TOP OF MULCH PVC SCH 80 LE (LENGTH E ED) MAR STREET ELL ICAL '1/2 -INC SCH 80 NIPPLE ® (LENGTH REQUIRED) PVC SCH 40 TEE OR ELL PVC LATERAL PIPE NOTE: ALL HEADS TO BE KEPT O A MINIMUM OF O 2" FROM ANY FENCE OR WALL INSTALL POP-UP HEADS ADJACENT TO ALL WALKING SURFACES SHRUB SPRAY / BUBBLER ON IRtSTR 1 INSTALL EMITTERS AT \"p MEXICAN FAN PALMS SHALL APPROXIMATELY 18" BE SKINNED ONE THIRD OF FROM THE ROOT BALL THE OVERALL TRUNK HEIGHT (FROM THE GROUND UPWARD) BACKFILL TO BE 20X SAND AND SOX ON-SITE NATIVE SOIL / COMPACT TO 85X DO NOT BLEND ORGANIC MIX BACKFILL AFTER SETTLING OCCURS IN PALM TREE BACKFILL PRE -MOISTEN HOLE PRIOR TO SETTING ROOT BALL ROOTBALL WATER BASIN BERM TYPICAL BOTH SIDES BACKFILL FIRM SOIL PRIOR TO SETTING JET SOIL AFTER ROOTBALL TO PREVENT SETTLING BACKFlWNG TO EUMINATE AIR POCKETS SHRUB SPRAY /BUBBLER ON RISER X11 Z co SEE PLAN FOR VALVE SIZE AND SYSTEM REQUIREMENTS A.E. VALVE BOX. SEE PLAN SHEET FOR LOCATION OF PROPOSED EQUIPMENT. VALVE BOX TO BE 12" X 18" I.D. TA N ELECTRIC REMOTE CONTROL VALVE PVC UNION PVC SCH. 80 90• ELL PVC MALE ADAPTER MAINLINE BRICK STABILIZER TYP. 3/4" CRUSHED ROCK BALL VALVE 0 FCONTROL WIRES WITH 24" EXPANSION COIL WIRE CONNECTORS ERS OR FINISH GRADE CONNAPPROVED EQUAL TO SPRINKLERS — ANGLE PIPE TO SPECIFIED DEPTH WITH 45• ELLS -PVC UNION . , PTH OF 3/4 - PVC SCH. 80 PIPE CRUSHED &ALt COMMON AND CONTROL WIRES BUNDEL AND TAPE TO MAINLINE PER TRENCHING DETAIL MAINLINE SIZE AS NOTED ON PLAN ALL IRRIGATION VALVE BOXESLAECONTROL do QUICK COUPLER) REMOTE SHALL BE NUMBERED AND sm * ALL FITTINGS SHALL BE PVC ALLOW 1" TO 2" AIR SPACE BETWEEN BOTTOM OF VALVE do TOP OF 3/4" CRUSHED ROCK E 36" STAE STAII.Lr_-%Q J 1 LLL CPNVUJ ,/�EMOTE CONTROL VALVI LOW VOLTAGE CONTROL WIRES SLEEVE SIZE AS REQUIRED • NOTE: NO OTHER TRADES (ELECT., UGHTING SHALL BE ALLOWED TO USE THE SAME TRENCH AS IRRIGATION PIPE • PROVIDE 24" COVER FOR DIRECT BURIAL CABLE • ALL SLEEVES TO BE PVC SCH 40 PIPE • ALL SLEEVES TO BE SIZED TWICE THE DIA. OF THE PIPE RUN • ALL SLEEVES TO RUN A MIN. OF 12" BEYOND HARDSCAPE EDGES 5 IRRIGATION SLEEVE DETAIL 1 SEE IRRIGATION SPECIFICATIONS FOR BACKFILL AND COMPACTION REWIREMENTS. NON -PRESSURE LATERAL LINE PIPING FINISH GRADE PRE88lIRE :'•:.';;. MAIN LINE PIPING PROVIDE 2" OF CLEAN BACKFILL UNDER ALL PIPING • NOTE: NO OTHER TRADES (ELECT. LIGHTING) CONTROL. WIRES SHALL BE ALLOWED t0 USE THE S,�ME TRENCH TAPE AND 54,01-E AS IRRIGATION PIPE EVERT 10' • PROVIDE 2411 COVER FOR DIRECT BURIAL CABLE • PROVIDE P.V.C. SCH. 40 SLEEVES FOR ALL WIRING AND PIPING UNDER PAVING • NO STAKING (VERTICALLY) OF PIPES IN THE SAME TRENCH 6 1 IRRIGATION TRENCHING DETAIL 12 NOTES: 1. INSTALL PER LOCAL CODE 2. APPROVED PLASTIC TAPE - 3/4* WIDE SHALL BE USED ON ALL THREADED W A a N z 0 N CONNECTIONS. FINISH GRADE 3. ALL PIPE AND FITTINGS SHALL BE AIN, BRASS OR AS NOTED. REDUCED PRESSURE PRINCIPLE U BACKFLOW PREVENTER SHALL BE PLACED IN A VANDAL-RESISTANTni 4=77 d — - LOCKING ENCLOSURE. SIZE AS REQ. z CONFIRM FINAL LOCATION WITH CITY. 00 INUICIK�CUO�UPRIER VALVE BALL VALVES d N VALVE BOX, AMATEK OR EQUAL Un o BRASS NIPPLE ` • WYE STRAINER TO BE 6" MIN. DEPTH CLEAN PEA GRAVEL PLACED ON THE BRASS 90' ELL w .. �- DOWNSTREAM SIDE (TYPICAL) d BRICK STABIUZER TYP. D BRASS UNION BRASS NIPPLE VANDAL- RESISTANT� BRASS NIPPLE � A"' A � " BRASS ELBOW LOCKING LE MEUR W r� BACKFLOW PREVENTION 110 (TYPICAL) p q¢ ENCLOSURE W/ VANDAL a s V o W PROOF LOCK BOX FINISH GRADE Wj a i.;A.•'; ••fit• :a `\ 1 ►. a+.r �; ti. F -I •':� 12"X12"X12" -;•►,� •,:;a TEE OR ELL CONCRETE THRUST TO SPRINKLERS BLOCKS ;r•,; • o ;1~ O PVC MAINLINE ..;, .. ,;•,;,; : ,:.::•�•*•+ x• p cv a U TO POINT OF CONNECTION ADAPT AS REQUIRED INSTALL PER CITY STANDARD n QUICK COUPLER DETAIL 7 R.P. BACKFLOW DEVICE 3 LOCATE CONTROLLER IN A STAINLESS STEEL STRONG BOX ENCLOSURE W/ DETER I MODEL ASB-24SS/ 120y SEE IRRIGATION LEGEND a C FERTIUZER TABLET SCHEDULE PREVAILING WIND �•-+ NO. OF TABLETS * ALL WIRING TO ..� 24" BOX 15 TABLETS STAKE TREE PERPENDICULAR TO BE INSTALLED PER �_ WEATHERPROOF W 36" BOX 19 TABLETS PREVAILING WIND ALL LOCAL CODES. CONTROLLER MODULE Q NOTE: THIS IS ONLY A GUIDE FROM MANUFACTURER'S FINISH GRADE 120 VOLT POWER do Z Z SPECIFICATIONS. O GROUND CONNECTIONS 1 2 POP-UP ROTOR JUNCTION BOX CONTROL WIRE 1/2- I.D. REINFORCED 3 KBI: KC 500 (MXF) THREADED 1/20 CONNECTIONS TEMPORARY WATERING BASIN —\ RUBBER HOSE CINCH TIE MT) IN -UNE CHECK VALVE CONDUIT �2" DIA. LODGEPOLE PINE STAKES. PLACE (10' PO 4 1/2" X 2" SCH. 80 NIPPLE 2" DIA. STEEL PIPE POST H O STAKES AT OUTER EDGE OF ROOTBALL 25 PVC SCH 80 NIPPLE SLEEVE E 1$9 1" THK. MULCH SEE PLANTING PLAN SHEET L-6 (LENGTH AS REQUIRED) MOUNTING FLANGE W/ Z !9? 3 O6 MARLEX STREET ELLS ANCHOR BOLTS O 1'•� aD V OQI N 11-0 VENTILATED TRUNK PROTECTORS IN TURF AREAS 4 O PVC SCH 40 TEE OR ELL1.CONCRETE FLOOR O S U A MIN. FINISH GRADE OPVC LATERAL PIPE 12" MIN. DEPTH • '•;. A Z PLANTING SOIL AND 5 12' MIN. MIN. _ FERTILIZER 6 KBI: KC -500 (MXF) THREADED 1 INTO NATIVE SOIL ` EXISTING SUBGRADE OF DIR IAL WIRE W a z PR SHALL BE TWO TIMES THE O TAMPED BACKFILL MIX FIRMLY. DIAM• AND TWO TIMES THE DEPTH a COMPACT TO AVOID SETTLING. OF THE ROOT BALL CITY OF FONTANA, CALIFORNIA PRE-SOAK HOLE PRIOR "DEEP ROOT" CON ROL BARRIER DRAWN BY DATE TO PLANTING SHALL BE INSTALLED ON ANY TREE DSC ANTED WITHIN 5' OFHARAPE. 2 SCAPC ,,_ BPI< 2/6/02 LINEAR TYPE DRAWN BY: SCALE: �' �.�'( '1 FRF `'yid JOB NO. 24' PASSED ROOT BALL ON EACH SIDE ��: JtO1� • SET TREE CAREFULLY IN GROUND WITH THE 6 5 7 6 8 DESIGNED BY: � ti FINAL TOP GRADE OF THE TREE EXPOSED 1" ABOVE GROUND LEVEL. (ALLOWS FOR SETTLING) • REMOVE BASIN PRIOR TO END OF MAINTENANCE PERIOD. CHECKED BY: PROVED S,!} a e L DWG. N0. 4 * 10/31/02 * SHEET NO. DATE.CITY RORW R.C. , EXP. DATE .0 31 3 6 R""w°' • L-4 TREE PLANTING DETAIL 12 POP UP ROTOR IG ION CONTRO ER � CA�\F `P 4 OF �p SHTS.