GENERAL NOTES:
1. ALL WORK SHALL BE IN ACCORDANCE WITH THESE PLANS, THE CITY OF FONTANA STANDARD PLANS,
THE CONTRACT PROVISIONS AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS
CONSTRUCTION( -GREEN BOOK"). ALL REFERENCE SPECIFICATIONS AND STANDARDS SHALL BE THE
LATEST EDITION UNLESS OTHERWISE NOTED.
2. WHEN A TECHNICAL CONFLICT IS FOUND TO EXIST IN THE CONTRACT DOCUMENTS THAT CAN NOT BE
RESOLVED BY REFERENCE TO PRECEDENCE PROVISIONS IN THE "GREEN BOOK", THE CONTRACTOR
SHALL IMMEDIATELY REPORT SAID CONFLICT TO THE CIN ENGINEER FOR RESOLUTION.
3. ALL MATERIALS AND METHODS ARE SUBJECT TO THE APPROVAL OF THE CITY ENGINEER.
4. CONSTRUCliON PERMITS SHALL BE OBTAINED FROM THE CITY OF FONTANA COMMUNITY DEVELOPMENT
DEP,,RTMENT, ENGINEERING DIVISION PRIOR TO THE START OF ANY WORK. INSPECTION
COORDINATION SHALL BE REQUESTED AT LEAST TWO WORKING DAYS PRIOR TO THE START OF ANY
WORK IN PUBLIC RIGHT-OF-WAY WITHIN THE CITY LIMITS, CALL (909)350-7610.
5. THE CONTRACTOR SHALL CONFORM TO ALL TRAFFIC CONTROL POLICIES, METHODS AND
PROCEDURES DESCRIBED IN THE STATE OF CALIFORNIA MANUAL OF TRAFFIC CONTROLS, LATEST
NON -METRIC EDITION UNLESS OTHERWISE DIRECTED BY THE CITY TRAFFIC ENGINEER.
6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN BARRICADES, DELINEATORS
OR OTHER TRAFFIC CONTROL DEVICES AT ALL TIMES.
7. THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR TRENCH WORK FOR
TRENCHES 5 FEET OR GREATER IN DEPTH FROM THE CALIFORNIA STATE DIVISION OF INDUSTRIAL
SAFETY.
8. THE WALLS AND FACES OF ALL EXCAVATIONS GREATER THAN FIVE(5) FEET IN DEPTH SHALL BE
GUARDED BY SHORING, SLOPING --OF THE GROUND OR OTHER APPROVED MEANS PURSUANT TO THE
REQUIREMENTS OF THE DIVISION OF INDUSTRIAL SAFETY OF THE STATE OF CALIFORNIA. TRENCHES
LESS THAN FIVE(5) FEET SHALL ALSO BE GUARDED WHEN THE POTENTIAL EXISTS FOR GROUND
MOVEMENT.
9. NO MATERIAL OR EQUIPMENT SHALL BE STORED IN THE PUBLIC RIGHT OF WAY WITHOUT
OBTAINING A SEPARATE PERMIT FOR THAT PURPOSE.
10. THE LOCATIONS OF UTILITIES SHOWN HAVE BEEN DETERMINED FROM AVAILABLE INFORMATION,
HOWEVER, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE, IN THE FIELD,
THE TRLE LOCATION AND ELEVATION OF ANY EXISTING UTILITIES, AND TO EXERCISE PROPER
PRECAUTION TO AVOID DAMAGE THERETO. THE CONTRACTOR SHALL CONTACT UNDERGROUND
SERVICE ALERT AT 1-800-227-2600 TWO WORKING DAYS BEFORE EXCAVATIONS,
11. THE CONTRACTOR SHALL COORDINATE CONSTRUCTION WITH ALL UTILITY COMPANIES INCLUDING,
BUT NOT LIMITED TO, GAS, TELEPHONE, ELECTRIC, CABLE TELEVISION, LANDSCAPING, LANDSCAPE
IRRIGATION, DOMESTIC WATER, RECLAIMED WATER, SEWER, STORM DRAIN, FLOOD CONTROL AND
CALTRANS, ALL UTILITY COMPANIES SHALL BE GIVEN TWO WORKING DAYS NOTICE PRIOR TO WORK
ARC'UND THEIR FACILITIES.
12. THE CONTRACTOR SHALL NOT OPERATE ANY FIRE HYDRANT OR WATER MAIN VALVES WITHOUT
APPROPRIATE AGENCY AUTHORIZATION. CONTRACTOR SHALL COORDINATE WITH THE APPROPRIATE
WATER COMPANY FOR VALVE OPERATION AND WATER REQUIREMENTS.
13. STATIONING REFERS TO THE CENTERLINE OF SEWER EXCEPT WHERE OTHERWISE NOTED.
14. ADEQUATE CONSTRUCTION CONTROL STAKES SHALL BE SET BY THE ENGINEER TO ENABLE THE
CONTRACTOR TO CONSTRUCT THE WORK TO THE PLAN GRADES. THE CONTRACTOR SHALL BE
RESPONSIBLE FOR THE PRESERVATION OF BENCHMARKS AND CONSTRUCTION CONTROL STAKING
DURING CONSTRUCTION.
15. THE CONTRACTOR SHALL NOT DISTURB EXISTING SURVEY MONUMENTS, MONU,EMT TIES OR BENCH
MARKS WITHOUT PRIOR NOTIFICATION TO THE CITY ENGINEER,
16. REMOVAL AND REPLACEMENT OF EXISTING SURVEY CONTROL, INCLUDING SURVEY MONUMENTS,
MONUMENT TIES AND BENCH MARKS, SHALL BE DONE BY A REGISTERED CIVIL ENGINEER OR
LICENSED LAND SURVEYOR. SURVEY MONUMENTS THAT WILL BE DESTROYED AS A RESULT OF THIS
CONSTRUCTION SHALL BE REPLACED. THE CONTRACTOR SHALL NOTIFY THE ENGINEER ONE WEEK
PRIOR TO CONSTRUCTION SO THAT TIES TO MONUMENTS CAN BE ESTABLISHED FOR LATER
REPLACEMENT OF THE MONUMENT.
17. THE CONTRACTOR SHALL MAINTAIN ACCESS FOR LOCAL RESIDENTS AND BUSINESSES AT ALL TIMES.
A MINIMUM 12 FOOT LANE SHALL BE MAINTAINED AT ALL TIMES IN THE CONSTRUCTION AREA FOR
RESIDENTS AND EMERGENCY VEHICLES.
18. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN AN EFFECTIVE MEANS OF DUST CONTROL,
INCLUDING ADEQUATE WATERING, AT ALL TIMES.
19. THE CONTRACTOR SHALL NOT CAUSE ANY EXCAVATED MATERIAL, MUD, SILT OR DEBRIS TO BE
DEPOSITED ONTO PUBLIC OR PRIVATE PROPERTY AD,.ACENT TO THE RIGHT OF WAY DURING
CONSTRUCTION WITHOUT PRIOR WRITTEN APPROVAL.
20. NO TRENCH BACKFILL SHALL TAKE PLACE WITHOUT PRIOR APPROVAL OF THE CITY INSPECTOR.
21. A GEOTECHNICAL ENGINEER SHALL CERTIFY ALL BACKFILL COMPACTION. FAILURE TO OBTAIN THE
REQUIRED DENSITY SHALL REQUIRE RE -WORKING OF THAT PORTION OF THE WORK UNTIL THE
SPECIFIED DENSITY IS OBTAINED.
22. CARE SHOULD BE TAKEN TO PREVENT GRADES, DITCHES, AND SWALES FROM UNDERMINING STREET
IMPROVEMENTS. UPON INSPECTION OF THE SITE, THE CITY ENGINEER MAY REQUIRE TEMPORARY
NON-ERODEABLE SWALES ENTERING OR LEAVING IMPROVEMENTS.
23. ALL EXPOSED CONCRETE SURFACES SHALL CONFORM IN GRADE, COLOR AND FINISH TO MATCH
EXISTING CONCRETE.
24. IF SEWER CONSTRUCTION IS TO BE DONE IN PHASES,THE CONTRACTOR SHALL PROVIDE A TERMINAL
CLEANOUT AT THE PHASE BOUNDARY, NOT MORE THAN 150 FEET FROM THE DOWNSTREAM MANHOLE,
SEE CITY OF FONTANA STANDARD DETAIL FOR TERMINAL CLEANOUT.
25. SANITARY SEWER LINES SHALL BE CONSTRUCTED OF BELL AND SPIGOT OR BAND SEAL TYPE
VITRIFIED CLAY PIPE(V.C.P.) EXTRA STRENGTH CLASS AND SHALL CONFORM TO THE PROVISIONS OF
THE ASTM DESIGNATION C700 FOR V.C.P.
26. NO OPEN TRENCH SHALL BE ALLOWED AT THE END OF THE DAY WITHOUT PRIOR APPROVAL OF
THE CITY ENGINEER.
27. SHORT VCP STUBS WITH FLEXIBLE COMPRESSION JOINTS SHALL BE USED AT MANHOLE WALLS TO
ALLOW FC". MINOR DEFLECTIONS IN ALIGNMENT.
28. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL EXPOSE EXISTING FACILITIES, AND VERIFY
ELEVATION AND LOCATION OF CONNECTIONS. CITY APPROVAL OF CONNECTIONS TO EXISTING
FACILITIES DOES NOT IMPLY CORRECTNESS OF ELEVATIONS OR LOCATIONS SHOWN ON THE PLANS.
29. ALL 4" HOUSE LATERALS SHALL BE INSTALLED AT A 2% MINIMUM GRADE UNLESS OTHERWISE
APPROVED BY THE CITY ENGINEER.
UNDERGROUND SERVICE ALERT REV. REVISIONS DESCRIPTION
CALL: TOLL FREE
11-800
227-2600
TWO WORKING DAYS
BEFORE YOU DIG
30. TERMINATE ALL 4" HOUSE SEWER LATERALS 3 FEET
INSIDE THE LOT WITH A PLUG 12" BELOW THE
GROUND SURFACE. WHEN PUBLIC UTILITY EASEMENTS
EXIST NEXT TO THE STREET RIGHT OF WAY, THE
LATERAL SHALL TERMINATE 3 FEET INSIDE THE LOT AS
MEASURED FROM THE UTILITY EASEMENT.
31. THE SEWER CONTRACTOR SHALL STAMP AN "S" IN
THE FACE OF THE CURB AT THE LOCATION OF THE
SEWER LATERAL.
32. IF EXISTING UTILITIES OR ANY OTHER FACILITIES
CONFLICT WITH THE PROPOSED IMPROVEMENTS, THE
CONTRACTOR SHALL NOTIFY THE ENGINEER AND ALL
AFFECTED AGENCIES IMMEDIATELY.
33. NO CONCRETE SHALL BE PLACED UNTIL THE FORMS
AND REINFORCING STEEL HAVE BEEN PLACED,
INSPECTED AND APPROVED.
34. ALL UNDERGROUND UTILITIES SHALL BE INSTALLED,
TESTED AND APPROVED PRIOR TO PAVING OF STREETS.
35. APPROVED SOIL STERILANT IS REQUIRED UNDER ALL
NEW ASPHALT PAVEMENT PRIOR TO PLACEMENT.
36. ALL MANHOLES, CLEANOUT FRAMES, COVERS AND
VALVE BOXES SHALL BE RAISED TO FINISHED GRADE
BY THE PAVING CONTRACTOR UPON COMPLETION OF
PAVING.
37. UPON COMPLETION OF CONSTRUCTION, CONTRACTOR
SHALL RESTORE ALL SIGNING, STRIPING, BARRICADES,
AND OTHER TRAFFIC CONTROL DEVICES TO THE
SATISFACTION OF THE CITY TRAFFIC ENGINEER.
38. AS -BUILT DRAWINGS SHALL BE PROVIDED BY THE
CONTRACTOR TO THE ENGINEER OF RECORD, WHO
SHALL PROVIDE RECORD DRAWINGS TO THE CITY
ENGINEER.
CITY OF FONTANA
SEWER LATERAL PLAN
16444 VALENCIA AVE.
PRIVATE ENGINEER'S NOTICE TO CONTRACTOR:
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND
UTILITY PIPERS AND/OR STRUCTURES SHOWN ON THESE
PLANS WERE OBTAINED BY A SEARCH OF THE AVAILABLE
RECORDS. THESE LOCATIONS ARE APPROXIMATE AND SHALL
BE CONFIRMED BY THE CONTRACTOR, SO THAT ANY
NECESSARY ADJUSTMENT CAN BE MADE IN ALIGNMENT
AND/OR GRADE OF THE PROPOSED IMPROVEMENT. THE
CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY
MEASURES TO PROTECT ANY UTILITY LINES SHOWN AND ANY
OTHER LINES NOT ON RECORD OR NOT SHOWN ON THESE
PLANS.
CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE
WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, HE
WILL BE REQUIRED TO ASSUME
SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE
CONDITIONS DURING THE COURSE OF CONSTRUCTION OF
THE PROJECT, INCLUDING THE SAFETY OF ALL PERSONS
AND PROPERTY. THIS REQUIREMENT SHALL BE MADE TO
APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL
WORKING HOURS, CONSTRUCTION CONTRACTOR FURTHER
AGREES TO DEFEND, INDEMNIFY AND HOLD DESIGN
PROFESSIONAL HARMLESS FROM ANY AND ALL LIABILITY,
REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE
OF WORK ON THIS PROJECT, EXCEPTING LIABILITY ARISING
FROM THE SOIL NEGLIGENCE OF THE DESIGN PROFESSIONAL.
10' 5' 0 5' 10'
1"=10' GRAPHIC SCALE
DATE I ENGR.I CITY I DATE
SHOULD CONSTRUCTION OF REQUIRED
IMPROVEMENTS NOT COMMENCE WITHIN
TWO YEARS OF THE DATE OF APPROVAL
SHOWN HEREON AND CARRIED FORTH IN A
DILIGENT MANNER, THE CFY ENGINEER MAY
REQUIRE REVISIONS TO THE PLANS TO
BRING THEM INTO CONFORMANCE WITH
CONDITIONS AND STANDARDS IN EFFECT
DEED BY ROTIMI LAWANI DATE
STA. 7+32
PER SEWER DWG NO. 75/100
-VALENCIA
COLLECTION SYSTEM, PLAN 8 PROFILE, SHEET 75/100
B4SIS OF BEARINGS.•
BASIS OF BEARINGS WAS DERIVED FROM THE CENTERLINE OF VALENCIA AVENUE AS SHOWN
ON PARCEL MAP N0, 16393, P.M.B. 211/44-46. BEING N.89'44102"E.
PREPARED FOR:
LAWANI ROTIMI 1
1277 W WABASH ST
RIALTO, CA 92376
(909) 225-2335
BENCHMARK.'
CITY OF FONTANA BM 404 BEING A NAIL
IN POWERPOLE / 634946H 0 N.W.
CORNER OF VALENCIA AVE. & CYPRESS
AVE.- ELEV. =1256.32"
EX. MH -3
A. +59
PER SEWER 0 W N0. 75/100
AVP -.-,'NUE
-S - - -- S -
Plan Prepared By:
GUOXIN MAD 06/10/15
Date
Apple Engineering Group
Subdivision, Engineering Design & Survey
9080 TELSTAR AVENUE, SUITF 909
EL MONTE, CA 91751
Tel: (628) 552-9818 RMAIL 1nfoiMppieeagInewin` net
VICINITY MAP
NOT TO SCALE TG.#- 604-H2
CONSTRUCTION NOTES: kTY
O1 CONSTRUCT 4" VCP SEWER LATERAL PER CITY STD 2005 35 LF
O
P)
1 EA
J
CITY STD 2005 AND STD 2006
O
PROVIDE TRENCH AND TRENCH REPAIR PER CITY STD 1008
210 SF
O4
-
-M
95% COMPACTED NATIVE SUBGRADE PER CITY STD 400
G
OS
GRIND AND OVERLAY 0.1' MIN. AC PER DETAIL "A"
76 SF
-4-
INSTALL RESIDENTIAL CURB DRAIN PER CITY STD 3002
1 EA
o
Ln
Ln
ri
Ln
u)
N
N
EX.
MH
-2
STA. 7+32
PER SEWER DWG NO. 75/100
-VALENCIA
COLLECTION SYSTEM, PLAN 8 PROFILE, SHEET 75/100
B4SIS OF BEARINGS.•
BASIS OF BEARINGS WAS DERIVED FROM THE CENTERLINE OF VALENCIA AVENUE AS SHOWN
ON PARCEL MAP N0, 16393, P.M.B. 211/44-46. BEING N.89'44102"E.
PREPARED FOR:
LAWANI ROTIMI 1
1277 W WABASH ST
RIALTO, CA 92376
(909) 225-2335
BENCHMARK.'
CITY OF FONTANA BM 404 BEING A NAIL
IN POWERPOLE / 634946H 0 N.W.
CORNER OF VALENCIA AVE. & CYPRESS
AVE.- ELEV. =1256.32"
EX. MH -3
A. +59
PER SEWER 0 W N0. 75/100
AVP -.-,'NUE
-S - - -- S -
Plan Prepared By:
GUOXIN MAD 06/10/15
Date
Apple Engineering Group
Subdivision, Engineering Design & Survey
9080 TELSTAR AVENUE, SUITF 909
EL MONTE, CA 91751
Tel: (628) 552-9818 RMAIL 1nfoiMppieeagInewin` net
VICINITY MAP
NOT TO SCALE TG.#- 604-H2
CONSTRUCTION NOTES: kTY
O1 CONSTRUCT 4" VCP SEWER LATERAL PER CITY STD 2005 35 LF
O
INSTALL SEWER CLEANOUT AND CLEANOUT BOX PER
1 EA
CITY STD 2005 AND STD 2006
O
PROVIDE TRENCH AND TRENCH REPAIR PER CITY STD 1008
210 SF
O4
CONSTRUCT MIN. 4" A.C. PAVEMENT OVER 12" OF
138 SF
95% COMPACTED NATIVE SUBGRADE PER CITY STD 400
OS
GRIND AND OVERLAY 0.1' MIN. AC PER DETAIL "A"
76 SF
O
INSTALL RESIDENTIAL CURB DRAIN PER CITY STD 3002
1 EA
REMOVE RE
EXIST PAVEMENT AND (MIN.) (NJ}) r/ HEADER WHI
OVERLAY 0.10' MIN. / APPLICABLE
EXISTING PAVEMENT l DETAIL "A"
NOT TO SCALE
1 IT11 IT/ r%f-%K1-rA/%TG%.
THE CONTRACTOR SHALL NOTIFY THE FOLLOWING UTILITIES OR AGENCIES
A MINIMUM OF TWO WORKING DAYS PRIOR TO COMMENCING CONSTRUCTION.
AT&T: (510) 645-2929
CITY OF FONTANA: (909) 350-7610
TIME WARNER CABLE: (909} 975-3398
SOUTHERN CALIFORNIA GAS COMPANY: (909) 335-7583
FONTANA WATER COMPANY: (909) 201-7333
SOUTHERN CALIFORNIA EDISON COMPANY: (909) 928-8270
INLAND EMPIRE UTILITIES AGENCY: (909) 993-1600
ESSIONq CITY OF FONTANA, CALIFORNIA
' N M/�o Fac SEWER LATERAL PLAN
059 GM APN: 0191-191-04-0000 DRAWN BY: SCALE.
16444 VALENCIA AVE.,
2 31 16 D D BY: _FONTANA, CA 92= DATE:
CIVo- -X ' CHECKED BY:
DRAWING NO.: 1
Arl, 5291
/
J51152 1