Loading...
HomeMy WebLinkAbout4317-123TRAFFIC SIGNAL CONSTRUCTION NOTES:. F11PROTECT EX I ST I NG TYPE 90 CONTROLLER EQU I PMENT PACKAGE I NCLUD NG TYPE "R" CABINET, SOLO PRO DETECTION AND APPURTENANT EQUIPMENT (SEE SPECIAL PROVISIONS). CONTRACTOR SHALL FURNISH AND INSTALL ANY ADDITIONAL ELECTROIIC EQUIPMENT REQUIRED TO PROVIDE THE DESIRED SIGNAL OPERATION AS SHOWN 01 THE PLAN, 20 PROTECT EXISTING TYPE III -BF SERVICE EQUIPMENT ENCLOSURE. F31RELOCATE EXISTING UNI -DIRECTIONAL, SINGLE CHANNEL OPTICOM DE'ECTOR, (MODEL 711 OR EQUAL) , AS DIRECTED BY THE ENGINEER (SEE SPEC AL PROVISIONS). R4RELOCATE EXISTING IMAGE SENSOR UNIT PER CITY STANDARD DRAWIIG 4004 AND AS DIRECTED BY THE ENGINEER (SEE SPECIAL PROVISIONS). r_51REMOVE EXISTING POLE AND REMOVED POLE TO BECOME PROPERTY OF ;ONTRACTOR. RELOCATE EQUIPMENT TO NEW POLE LOCATION. REMOVE EXISTING SIGNAL FOUND►TION COMPLETE. r6_1 INSTALL 133-4 SIGN AND HARDWARE PER CALTRANS DETAIL "U", ES -71. r_71CONNECT INTERCONNECT PER TRAFFIC SIGNAL CONTROLLER MANUFACTUIER'S REQUIREMENTS. ® INSTALL 2" CONDUIT WITH ONE -(I) INTERCONNECT CABLE (6 PR. #2!). rg-]FURNISH AND INSTALL ONE (1) 96 STRAND SMFO CABLE IN ORANGE H)PE CONDUIT. WHERE CABLE PASSES THROUGH SPLICE VAULT, COIL 50 FEET OF 96 STRAND SMFO N EACH VAULT, [10 FURNISH AND INSTALL 6-1.5q SCHEDULE 40 HDPE CONDUITS. THE COIDUITS SHALL BE COLORED CODED ORANGE, YELLOW, RED, BLACK, BLUE AND GREEN. FURNISH ANI INSTALL ONE PULL ROPE !N ALL CONDUITS FOR FUTURE CABLE. CONDUIT SWEEPS SIALL BE INSTALLED WITH A MINIMUM 10 -FOOT RADIUS., < LU R/W� a D Z LU POLE SCHEDULE c L C STANDAR) MASTARMS LUMINAIRE SIGNAL MOUNTING PED PUSH( BUTTON R.S.N.S. _ P A N,,T �WE A REMARKS Prepared Under The Supery l s l on Of ' HT. SIG. LU M. H.P.S.V. MAST ARM POLE PED. PHASE LOCATION MESSAGE A B A 29A-5-161 NI 35' N 55' N 15' N 250W N 3 -MAS R V -1-T R SP-1-CS(R) 2 R W Banana Ave R 3' 4' F=23' B 1-A (N) 10' (N) - - - - TV-2-T(R) SP -1 -NR) 4 R N - 3' 4' - C 19A -4-161(N) 35' (N) ® 20'(N)15' N 250W N MAS R SV-1-T(R) SP -1 -NR) 4 R N Jurupa Ave (R) 3' 4' 4317 30 (N) ' 35 (N) 15' N 250W N - TY ENGINEER - 3' 'D 4 - E 61A -5-161(N) 35' (N) 60' N 15' N 250W N 2—MAS �Rj V-1 -T R SP -1 -NR) 6 R E Banana Ave R 21' 4' F=22' F 1-A N 10' N - _ - - TV-2-T(R) SP -1 -NR) 8 R S - 23' 4' G 26A -4-161(N) 35' (N) 35' N 15' N 250W N MAS R V -1-T R SP -1- R 8 R S Juru a Ave R 23' 4' H 30 N 35' (N) I - 15' N 250W N - V -1-T R SP-1-CS(R) 2 R W - 22' 4' - DETAIL A 0 1 = -� HK401 30'- 3�' ,, (-381 GROUP B SEE TRAFFII SIGNAL GENERAL NOTE 13. COAn'RftToR- INSTALL R.SN.S. ON POLE SHAFT USING SPECIAL -FURNISHED MAST ARM. CONTRACTO; TO FURNISH AND INSTALL PEDESTRIAN COUNTDOWN TIMERS PER F=_ 20 40 60 4 (001--- 3 Prepared Under The Supery l s l on Of ' SPECIAL PR)VISIONS. CITY OF F CALIFORNIA 01 SPECIAL MAST ARM (N) - NEW EQUIPMENT (R) - RELOCATED EQUIPMENT 03 04 ;E LEGEND "A MFA"A R/W M Ct>< M =��I���v000000 BCR 1 " ' 05 BCR '!' - UNI -DIRECTIONAL, SINGLE CHANNEL OPTICAL OF FO A T DETECTOR. DESIGNED BY: DATE -�O��I�v000000 n r—, n ►� - IMAGE SENSOR UNIT.A PHASE DIAGRAM CONDUIT SIZE GROUP A GROUP B MIS F=_ 20 40 60 4 (001--- z Qfx Prepared Under The Supery l s l on Of ' b CITY OF F CALIFORNIA 01 02 03 04 TRAFFIC SIGNAL MODIFICATION "A "A MFA"A FA"A M Ct>< M =��I���v000000 �� - SCA1,E: I _2 0 m C 51616 05 06 07 08 I PREPARED BY: PMK ASSOCIATES, INC. 23 BENAVENTE . IRVINE, CA 92606 ._ CONDUIT SIZE N TO MULBERRY AVE. 9 (±27500) 1101 R/W --JURUPA AVENUE - 6E A 0 48 - 0�_ 02PL - J - f i EXIST. 2"C, 2 6 I 0 P48 3 ��=J 9 TO ALMOND AVE. BCR S I A I (±1400 ) 3 2> O 19A-4-80 6 �j� �02 _ 5 EX I ST I SERV I CEGPOa T I ON I LJ --- '; 20' 20' L7 --- --- Spvevice 688ress* iyo$9 Surupo, Ave. �, S, 117 1 O rev ��oN oes�wnorr 7 MM'M,N,MNNNVN«W OVVVVVV~ DLL FREE 1-800-227-2600 A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT \\ora—filsrv01 \ustnpro j\200093\003\pro ject_drawings\traffic_signals\200093spO5.d9n 12/4/2007 11:31:43 AM DFLTUSER R/W 1 ..00001 DATE I ENGR. I CITY I DATE "- R/W Ilk SHOULD CONSTRUCTION OF THE REQUIRED IMPROVEMEN'S NOT COMMENCE WITHIN TWO YEARS OF THE DATE OF APPFOVAL SHOWN HEREON AND CARRIED FORTH IN A DILIGENT MANNER, THE CITY ENGINEER MAY REQUIRE REVISIONS TO THE FLANS TO BRING THEM INTO CONFORMANCE WITH CONDITIOIS AND STANDARDS IN EFFECT. CONDUCTOR TABLE CONDUIT SIZE MIS F=_ 20 40 60 (N) —NEW =- Prepared Under The Supery l s l on Of ' CITY OF F CALIFORNIA QRoFESS/0 _____§A"A TRAFFIC SIGNAL MODIFICATION "A "A MFA"A FA"A M M =��I���v000000 �� - SCA1,E: I _2 0 m C 51616 6-30-08 T DESIGNED BY: DATE -�O��I�v000000 A,.AAc, EN U E 12/5/2007 (NECKEDBY 0 B • � DRAWING NO.: 12 �o0a��v000000 .'+► 4317 47 • TY ENGINEER R.C.E. 51152 DATE: �000� X000000 �v000�v00�000 �v00000�0�I00 �v00000�0���01 E'er „ ► : �: �•1�.�����000���+��+��+��•� SCALE IN FEET CONDUIT SIZE MIS F=_ 20 40 60 (N) —NEW =- Prepared Under The Supery l s l on Of ' CITY OF F CALIFORNIA QRoFESS/0 TRAFFIC SIGNAL MODIFICATION PLAN SCALE IN FEET CONDUIT SIZE 0 F=_ 20 40 60 (N) —NEW =- Prepared Under The Supery l s l on Of ' CITY OF F CALIFORNIA QRoFESS/0 TRAFFIC SIGNAL MODIFICATION PLAN DRAWN BY: �h� J U R U PA AVENUE �� - SCA1,E: I _2 0 m C 51616 6-30-08 T DESIGNED BY: DATE A,.AAc, EN U E 12/5/2007 (NECKEDBY 0 B • � DRAWING NO.: 12 o F c Oki-* Dote: 12/5/07 .'+► 4317 47 TY ENGINEER R.C.E. 51152 DATE: